Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of Concrete any description and any position and pavings n.exc 15cm thickness (below or above ground level) all as specified and as directed. |
| 2 | Demolition of stone slabs and tiles of any description or thickness in floor aprons etc laid bedded and pointed in any mortor complete all as specified. |
| 3 | M&L for 75mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection and path finishing the surface even and smooth without using extra cement all as specified and as directed. |
| 4 | M&L for 50mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection and path finishing the surface even and smooth without using extra cement all as specified and as directed. |
| 5 | M&L for water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:- (i) Application of two components acrylic modified cementious coating;- (aa)The Surface to be applied shall be completely dry and free from containments such as dirt, dust, oil surface treatments and old coatings. Concrete substances must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coating and achieve a gripping profile that is clean, dry and free from laitance and dry other form of surface contamination. The installation instructions in manufacturer's published literature should be strictly complied with including but not limited to the following:-(bb) Chipping out any visible cracks in V-groove pattern as applicable. Special attention on the part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr. Fixit 302 SBR latex/perma lates SBR/FOSROC Nitbond SBR latex/Asian paint latex SBR as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacume pressure if required. (cc) Dampen all surfaces immediately ahed of application of Acrylic modified cementitious coating of SIKA top seal-107/Brush bond FOSROC/Dr Fixit/STP/CICO. (dd) Whilst the surface is still damp from saturation apply one coat of Acrylic modified cementitious coating of SIKA top seal-107/Brush bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturers instructions. |
| 6 | (ee) Apply glass abric sheet of SIKA Fab-1/FOSROC/Dr Fixit/STP whilst first coat is wet. (ff) Once touch dry, apply second coat of SIKA Top seal-107/Brush bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instruction on the entire area. (gg) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat. (hh) The water proofing coating shoyuld be taken to a height minimum 300mm above the finished floor level on the vertical surface three sides including dismantling of existing tiles. (jj)It is essential to cure Acrylic modified cementitious coting immediatly afer application for a minimum of 3 to 5 days to ensure full ceent hydration and to minimize cracking. (kk) A protection plaster 12-15mm thick in CM 1:3 admised with appropriate integral water proofing compound has to be applied on the wall. Admixture: SIKA Plastocrete plus/FOSROC/Dr. Fixit/STP/CICO confirming to IS 2645. (ll) Providing and applying a protection screed of 50mm thick 1:4 cement sand mortor admixed with SIKA plastocrete over the applied waterproofing coating on horizontal surface. (mm) All the corners and joints should be pretreated with an elastic waterproofing sealing tape with a woven bonding mess on each surface and an elastic expansions zone in he centrwe of make SIKA seal tape/FOSROC/Dr. Fixit/STP. |
| 7 | (nn) The membrane has to be protected in accordance with the manufacturer's instructions until placement of concrete. The memberane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturers recommendations. (oo) Waterproofing treatment has to be carried out through applicasors authorised by the respective manufacturers and approved by GE. (iii) All the joints of pipes and traps within the sunken portion shall be seaed properly by epoxy sealent. (iv) All CI traps in sunken slab to be enclosed with PCC 1:1.5:3 (Min 15 cm) all around. (v) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40mm graded stone agg) complete all as specified. (Paid separately). (vi) Providing drainage spout pipe GI pipe 40mm dia bore light grade upto outside of outer wall (Appx 450/600mm)including cutting to existing wall and making good the disturbed surface complete all as specified. (vii) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate) as in flooring for laying floor finish all as specified. (Note:- Item No (v) and (vi) shall be measured and paid separately.) (Only floor area to be measured for payment). |
| 8 | M&L for PCC lean concrete 1:5:10 type E2 (using 40mm graded stone aggregate) laid in layers of not more than 10cm thick tamping etc complete all as specified and as directed. by Engr-in-Charge |
| 9 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 20 mm thick screed bed in CM 1:6 complete all as specified and as directed..Make:- Kajaria/Somany/Johnson |
| 10 | All as per Srl item No 9 here-in-before but on vertical surface such as riser, skirting, dado over and incl 10mm thick cement mortar 1:4 rough finish surface to receive tiles |
| 11 | M&L for 18 to 20 mm thick Granite (of any type) work in single piece (table rubbed and polished) in steps, floors, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade over and including 20mm thick CM (1:6) bedding layer complete all as specified and as directed. |
| 12 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including Rounding to edges of stone slabs one edge, such as in steps risers and treads and mirror polished all as specified and as directed. |
| 13 | All as per item No 12 here-in-before but on vertical surface such as riser, skirting, dado over and incl 10mm thick cement mortar 1:4 rough finish surface to receive tiles |
| 14 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 150 mm thick screed bed in CM 1:6 complete all as specified and as directed..Make:- Kajaria/Somany/Johnson |
| 15 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 15mm screed bed in CM 1:6, all as specified and as directed. by Engineer - in - Charge. |
| 16 | M&L for Glazed ceramic tiles of any colour in vertical surfaces 300 x 600x 8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat cement plaster in CM 1:4 including refixing electric points and switch boards where as specified and as directed.. Make:- Kajaria/Somany/Johnson |
| 17 | Demolition and dismantling of Reinforced cement concrete any description and any position and pavings n.exc 15 cm thickness (below or above ground level) all as specified and as directed. |
| 18 | S&F MS TMT bars 10 mm dia & over, cut to length, bent to shape required including cranking and bending and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. by Engr-in-Charge |
| 19 | All as per Srl Item No. 18 here-in-before but 8 mm dia as in stirrups, spacers and binders complete all as specified |
| 20 | S&F Mild steel bars TMT 6 to 8 mm dia and over cut to length bent to shape required including bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 21 | M&L for PCC 1:2:4,type B-0 (using 12.50mm graded aggregate.) as in slab supported on wall, beams and columns in floors, roofs, landing, balconies deck slab and in shelves and like all as specified and as directed.. |
| 22 | M&L for RCC M-25 (20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork complete all as specified and as directed. |
| 23 | M&L for RCC (nominal mix) 1:2:4 type B-1 (using 20mm graded aggregate) in Foundations, Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified |
| 24 | M&L for RCC (nominal mix) 1:2:4 type B-1 (using 20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 25 | M&L for RCC (nominal mix) 1:2:4 type B-1 (using 20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified |
| 26 | M&L for RCC (nominal mix) 1:2:4 type B-1 (using 20mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified |
| 27 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified |
| 28 | M&L for Rendering 15 mm thick CM 1:6 on fair faces of brick work or concrete surfaces and to be finished even and smooth(without using extra lime or cement) complete all as specified |
| 29 | All as per Srl item No. 28 here-in-before but in cm 1:4 on external surfaces |
| 30 | M&L for 15mm thick cement plaster in cement mortar 1:4 on brick or concrete surface with water proofing compound finished even and smooth without using extra cement complete all as specified |
| 31 | M&L for 5mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 32 | Supply only water proofing compound all as specified |
| 33 | S&F in repairs two piece EWC 680x360x765mm white, with seat cover and Twin flushing cistern complete all as specified and as directed. by Engr-in-Charge as per CERA -CAT No. S1021103 S Trap 230mm, CAT No S1060101 Cistern, CAT No B1510101 seat cover, CAT No B1810101 Twin Flush fittings all as specified |
| 34 | S&F Chromium plated brass JET including PVC pipe connection fixed to EWC all as specified and as directed. |
| 35 | Dismantling of cast iron/PVC or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches if required 100/75 mm internal dia pipe complete all as specified |
| 36 | S&F PVC (SWR) pipes of dia 110mm bore single socketed in any length with rubber ring joints fixed to walls/in trenches complete all as specified |
| 37 | S&F PVC (SWR) pipe of 75mm bore in single socketed in any length with rubber ring joints fixed to walls complete all as specified |
| 38 | S&F PVC (SWR) bends of 110 mm dia bore with access door complete all as specified and as directed. |
| 39 | S&F PVC (SWR) bends of 75 mm dia bore with access door complete all as specified and as directed. |
| 40 | S&F PVC (SWR) vent cowl of 110mm dia bore complete all as specified and as directed. |
| 41 | S&F for 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.. |
| 42 | S&F 150mm Cast Iron gully trap setting and jointing with lead joint all as specified and as directed. |
| 43 | S&F for CP grating 125 mm dia with centre hole all as specified and as directed. by Engr in Charge. |
| 44 | M&L for PVC Nahani trap 75mm size with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 45 | Taking up or down steel tubing of bore 15 mm and connection, including cleaning for refixing or removal complete all as specified. |
| 46 | Taking up or down steel tubing 20 mm and connection, including cleaning for refixing or removal to store complete all as specified. |
| 47 | S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6 kgf/sqcm conforming to IS-15778 with all fittings such as Tee, Bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls/ floors (Concealed where required) with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure complete all as specified |
| 48 | S&F CPVC pipes, SDR 11, 25 mm outer dia of pressure rating 6 kgf/sqcm conforming to IS-15778 with all fittings such as Tee, Bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls/ floors (Concealed where required) with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure complete all as specified |
| 49 | S&F in repairs Wash basin wall hung with half pedestal 550x400 mm as per CERA -CAT No. S2040105 wash basin and Cat No S2090102 Half pedestal including waste pipe connections and pillar tap complete all as specified |
| 50 | S&F 600X450mm approved quality ready made cabinet mirror of selected quality glass, fixed in PVC frame around and 02 No's hanging clips and fixed to wooden plugs with CP brass screws and cup washers complete all as specified and as directed. |
| 51 | S&F in repair Bib taps 15 mm dia, fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm dia pipe complete all as specified |
| 52 | S&F Bib tap cast copper alloy, chromium plated suitable for 15mm bore iron pipe with long body fancy type complete all as specified and as directed. |
| 53 | S&F Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed in 15mm bore dia of pipe all as specified and as directed. |
| 54 | S&F Stop valves/Angle valve 15 mm dia, fancy type chromium plated, screwed down, high pressure, screwed both ends for 15mm dia pipe or for unions fixed in repairs all as specified and as directed. |
| 55 | S&F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified. |
| 56 | S&F PVC connection fiber, reinforced 45cm long 15mm in size with brass check nut and PVC washers at both ends complete all as specified |
| 57 | S&F Brass chromium plated overhead shower rose 120 mm dia with 3 flow with swivel joint, including shower arm, fixing to steel pipe or union including taking down old shower rose complete all as directed and specified by Engr- in- Charge. Make Cera shower rose F7020305 shower arm F7040104 or equivalent in Hindware/ Parryware |
| 58 | S&F Stainless steel sink, 1.00mm thick for kitchen with drainage board with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 59 | S&F Stainless steel kitchen plate rack of size 90x120 cmx1mm th (18 Gauge) not less than 8 kg in repair complete all as specified and as directed. |
| 60 | S&F Acrylic corner set of 3 piece as per sample approved by Engr-in-Charge all as specified and as directed. |
| 61 | S&F Powder coated aluminium alloy curtain rod of any size including fancy type brackets all as directed by Engg-in-charge |
| 62 | Taking down chowkats or frames n.exc 1.5 Sqm with shutter (without taking of shutter from the frame complete all as specified |
| 63 | Taking down chowkats or frames exc 1.5 Sqm and n.exc 4.00 sqm with shutter (without taking of shutter from the frame complete all as specified |
| 64 | M&L for MS work as in hold fast and similar small articles complete all as specified and as directed. |
| 65 | S&F Pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified |
| 66 | S&F Pressed steel frames 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified |
| 67 | S&F Structural steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 68 | S&F Flush shutters, 40mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.. |
| 69 | S&F 2nd class Hardwood 35mm thick glazed and skeleton shutters, openrebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified |
| 70 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing |
| 71 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing |
| 72 | S&F 100mm thick Butt hinges, medium weight, cold rolled mild steel, for PVC door shutter and fixed complete all as specified |
| 73 | S&F Aluminium bow handles, cast type, anodised 150mm long complete all as specified |
| 74 | S&F aluminium anodised, barrel tower bolt of extruded section and fixed to 150mm each complete all as specified and as directed. |
| 75 | S&F 200mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified |
| 76 | S&F 150mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified |
| 77 | S&F Mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified |
| 78 | S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified |
| 79 | S&F Aluminium floor door stopper 63mm with two rubber legged all as specified and as directed.. |
| 80 | S&F Magic eye brass best quality fixed in main door shutter approved by Engr-in-Charge complete all as specified and as directed. |
| 81 | S&F Mild Steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified |
| 82 | S&F HDF (HMR grade) board, 18/19mm th exterior grade, prelaminated both side decorative face lamination fixed with screws, brackets to timber frame work with and including 2nd class hard wood, 6mm thick all around edging, complete all as specified and as directed. |
| 83 | S&F 125mm Aluminium haps and staples safety type with mild steel hinge pin including bolt to hinge plate and fixed with screw complete all as specified and as directed.. |
| 84 | S&F Mild steel bright finish continuous (piano) hinges width of flaps (when open) in 30mm complete all as specified and as directed. |
| 85 | S&F 75 mm length extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 86 | S&F Aluminium Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified |
| 87 | S&F Harrison rails, aluminium anodised, chromium plated with fixing brackets, stops, rollers etc. complete all as specified |
| 88 | S&F aluminium powder coated ventilator partly fixed and partly louvered type without sash of bars, section as per designation 63400 of IS 737, frame and intermediate made out of aluminium section of size 50.80 x 25.40 x 0.95 mm (Catalogue No 14027 of M/s Jindal) including necessary heavy duty louvers (adjustable with locking arrangements), jointing clips, rubber packing, anodised snap beading, screws alongwith 4.00mm thick pin headed glass for louvers and glazing etc complete all as specified and as directed.. Note:- (i) The thickness of the powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE. (ii) Sealing the gap of frame with Jamb and Cill (alround) using silicon gel at the rate of 0.05 lit/m for both faces of window. |
| 89 | S&F Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165 all as specified |
| 90 | S&F Galvanised steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.18 mm and fixed to wooden skeleton shutter/Aluminium windows complete all as specified and as directed. |
| 91 | S&F in repairs galvanised steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.18 mm and fixed to wooden skeleton shutter/ Aluminium windows complete all as specified and as directed. |
| 92 | M&L for hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. |
| 93 | S&F 4mm Sheet glass, ordinary quality and glazing as in Aluminium windows, Doors, Ventilators etc in square/ rectangular shape n.exc 0.5 sqm in each pane including taking out and removal of old glass complete all as specified and as directed.. |
| 94 | S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sqm in each pane complete all as specified and as directed. |
| 95 | S&F Rotational moulded polyethylene water storage tanks of capacity 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and including dismantling of existing tank of any description complete all as specified and as directed.. |
| 96 | S&F rotational moulded synthetic (HDPE), UV Coating, water storage tank 1000 litre capacity (cylindrical vertical with closed top,) hoisted & fixed in position all as specified in SSR Part-I, including dismantling of existing water tank, complete all as specified & directed |
| 97 | S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/20mm-210gms./25mm-455gms/ 40mm- 690 gms) complete all as specified |
| 98 | S&F 20mm ball valve brass high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 99 | S&F 20mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified |
| 100 | S&F Stainless steel soap dish, white of size 160X160X90 mm as approved fixed with brass screws or embedded in wall complete all as specified . Make : Cera Cat No. F5003106 or equivalent in other makes as specified |
| 101 | S&F for Soap dish stainless steel chromium plated fixed with brass screws and rawl plug complete all as specified |
| 102 | Towel rail brass chromium plated fancy type 60cm long including bracket fixed between flanges complete all as specified Make: Cera Cat No. F5007103 or equivalent in Hindware/ Parryware |
| 103 | M&L for repairing RCC chajjas, projections, roof facia etc i.e scrapping, cutting , chisling derusting and cleaning eposed reinforcement, surface of damaged loose RCC surface and applying one coat of cement slurry and filling the surface with cement concrete (1:1.5:3) using 12.5mm graded stone agg and reinforced with welded mess of weight exc 2 Kg/Sqm but n.exc 3.0 Kg/Sqm with or without facia and finished with 15 mm thick in cm 1:4 using Ready mix plaster on external surface of brick walls surfaces mixed with water and all as per manufacturer instructions etc, finishing the surface even and smooth without using extra cement and including taking down cement plaster on brick/concrete surfaces and racking out joints, hacking for key scrubbing down with water and necessary scaffoldings etc, complete all as specified and as directed. . Make:- Ultra Tech / Silico / Renaplast/Kaneria Note-: Pricing are inclusive all scafoldings used for up to the height of 5 Mtr |
| 104 | Demolition of Brick tiles or terracing tiles, single layer on roofs covering complete all as specified and as directed.. |
| 105 | Demolition of Mud in roofs, any thickness, including plastering and leeping(whether full thickness removed or only a part thereof) all as specified and as directed. |
| 106 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone agg) in roof kerbs or mud stops, roof padding coping etc rounded or chamfered on edges all as specified and as directed. |
| 107 | M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in roof kerbs or mud stops, benching, edges of interlocking/ chequered tiles and the like including weathering, slightly rounded or chamfered angles throating, complete including necessary form work complete all as specified and as directed. |
| 108 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:3 mixed with waterproofing compound in the portion recommended by manufacturer on concrete roof surfaces finished even and smooth including cleaning the roof top by scraping down with water etc all as specified and as directed. |
| 109 | M&L for 12mm thick cement plaster in cement mortar (1:3) on concrete roof surfaces finished even and fair, including cleaning the roof top by water etc. with WPC complete all as specified and as directed. |
| 110 | Cleaning the surface and made free of foreign particle laitance followed by grinding all protrusion to make surface modulated. Therefore, inspection for cracks on the surface caused by thermal expansion/construction. Cutting the groves with suitable cutter machine in V-grooves filled with repairs mortar/micro concrete/general purpose grout as recommended proportionally as per recommendation of manufacture. And making the Gollas/Corners with polymer modified mortar (1:4) with 3% acrylic of cement weight complete all as specified and as directed. |
| 111 | Supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold applied of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm. Application should be done with Graco sprayer by a company authorised applicator ” of given. Make: STP/Asian Paints/Sikka Note:- Contractor will provide certificate from authorised applicator |
| 112 | M&L for coloured chequered cement concrete tiles 30cm X 30cm X 25mm thick set jointed & pointed in neat cement slurry with grey cement and pigments over 20 mm thick screed bed in CM (1:6) complete all as specified |
| 113 | M&L for Preparing newly plastered surface and priming with alkali resistant priming paint and applying 2 coats of oil bound distemper on walls over 3mm thick wall care putty complete all as specified and as directed. |
| 114 | M&L for preparation of old surfaces of wall and applying two coats of oil bound distemper over 2mm thick wall care putty complete all as specified and as directed. |
| 115 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces including removal of old paint and preparation of surface all as specified and as directed. |
| 116 | M&L for preparation of old surfaces of wall and applying two coats of white wash complete all as specified and as directed.. |
| 117 | M&L for preparation of new wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applied two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 118 | M&L for preparation of old wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applied one coat of synthetic enamel paint complete all as specified and as directed. |
| 119 | M&L for preparation of new steel or steel based surfaces of any description, not otherwise described, over 10cm width or girth and applied two coats of synthetic enamel paint over one coat of red oxide chrome primer complete all as specified and as directed. |
| 120 | M&L for preparation of old steel or steel based surfaces of any description, not otherwise described, over 10cm width or girth and applied one coat of synthetic enamel paint complete all as specified and as directed. |
| 121 | Demolition of Brickwork or stone/boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 122 | M&L for Brickwork with Modular bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 in narrow widths including Cutting out bricks/stone, forming toothing for, and bonding new into old brickwork /stone masonry complete all as specified |
| 123 | All as per Srl item No 122 here-in-before but except bricks |
| 124 | M&L for Brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radious built in CM 1:4 complete all as specified |
| 125 | M&L for Brick Work with Sub Class 'B' Brick straight or curved on plan to any radius in half brick thick walls built in CM 1:6 complete all as specified |
| 126 | M&L for 75mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base concrete complete all as specified and as directed. |
| 127 | M&L for 100mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base of flooring complete all as specified and as directed. |
| 128 | S&F Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and as directed. |
| 129 | M&L for 25 mm sand cushion, filling 30mm under floors or in foundations including watering and consolidation complete all as specified and as directed.. |
| 130 | M&L for concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete1:4:8 type D-2 (using 40mm graded aggregate) complete all as specified |
| 131 | M&L for Plain Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass-concrete complete all as specified and as directed. |
| 132 | M&L for Reinforced concrete pipes of 200 mm bore, class NP2, laid and jointed complete with collars complete all as specified and as directed. |
| 133 | M&L for cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in surface channels and drains complete all as specified and as directed. |
| 134 | M&L for providing, cement concrete, 1:2:4 Type B-1 (using 20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 135 | M&L for providing precast reinforced cement concrete 1:2:4 Type B-1 using 20 mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified |
| 136 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified |
| 137 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), for flat & rough finished surface of concrete complete all as specified. |
| 138 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.Form to floor and roof beams, lintels complete all as specified |
| 139 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified |
| 140 | M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide complete all as specified |
| 141 | M&L for three coats of white wash on newly plastered surfaces of wall including preparation of wall surfaces complete all as specified and as directed. by Engr-in-Charge. |
| 142 | M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of wall surfaces complete all as specified and as directed. by Engr-in-Charge. |
| 143 | M&L for preparing new plastered or unplastered wall surfaces and applied two coat of cement base paint over one priming coat complete all as specified and as directed. by Engr-in-Charge. |
| 144 | M&L for approved earth filling including spread and levelled in layers not exc 25 mm thick watering and rammed to a true surface complete all as specified. |
| 145 | M&L for hardcore of gauge n.exc 63mm deposited spread and levelled in layers n. exc 15cm thick watered and rammed to a true surface complete all as specified |
| 146 | M&L for 25 mm thick cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in to receive the top layer of tiles complete all as specified and as directed. |
| 147 | M&L for coloured glazed ceramic tiles of size 350x250x7mm/450x350x7mm mm thick set and jointed in neat cement slurry in vertical surface to wall pointing in white/coloured cement to match over and including 15mm thick rendering in CM 1:4 complete all as specified and as directed. |
| 148 | S&F medium grade steel water tubing, 15 mm bore galvanised with all fittings and fixed complete to walls or layed in floors all as specified and as directed. |
| 149 | S&F medium grade steel water tubing, 20 mm bore galvanised with all fittings and fixed complete to walls or layed in floors all as specified and as directed. |
| 150 | S&F for Vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern) incl seat cover and flushing pipe for pedestal pipe etc. complete all as specified and as directed. |
| 151 | S&F in repair health faucet 1.00mtr long flexible tube & wall hook of Make Prayag Cat No BEA-41 or Jaquar/Kohler/Cera suitable for 15mm dia for iron pipe or for brass ferrule all as specified & directed |
| 152 | S&F in repair Jet spray with holder for EWC 1.00 mtr long of Make Prayag Cat No BEA-17 or equivalent makes of Group I of Appx “B” suitable for 15mm dia for iron pipe or for brass ferrule all as specified & directed |
| 153 | S&F in repair, Sheet Glass Shelf Assembly, consisting of 5.5mm thick Sheet Glass Shelf 12 Cm Wide with Chromium plated Bracket Guard and Railing 60 Cm long, complete all as specified and as directed.. |
| 154 | S&F in repair, Sheet Glass Corner Shelves Assembly (Transparent), consisting of 5.5mm thick Sheet Glass Shelf with Chromium plated Bracket Guard and Railing, Make Jaquar CAT No CAN-1173 or kohler or Cera complete all as specified and as directed.. |
| 155 | S&F in repair, Coloured PVC bath Cabinet of size 450x450x90mm with Looking Mirror (as approved) fixing with Chromium plated Brass Screws and Wooden/Plastic Cleats, complete as all specified and as directed.. |
| 156 | S&F in repair new flexible PVC waste pipe of approved quality 32 mm bore, 75 cm long with one end socketed fixed to waste coupling including one PVC reducer 32mm complete all as specified and as directed. |
| 157 | S&F Stainless Steel Towel Reck 600 mm long all as specified and as directed. by Engr-in-Charge |
| 158 | S&F in repair, toilet paper holder of MAKE: Jaquar CAT No. CAN-1153S or Kohler or Cera and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed.. |
| 159 | S&F for PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle 10 Ltr capacity including brackets complete all as specified and as directed.. |
| 160 | S&F Vitreous china wash hand basin, white, flat back 550x400mm including one number brass CP waste coupling ,32mm dia, 32 mm PVC waste pipe with connector , brackets 2 Nos including cutting for and pinning in ends of brackets complete all as specified |
| 161 | S&F vitreous china urinal full stall type flat back complete incl providing and fixing plugs bedding urinal against wall in CM(1:2) securing urinal to plugs with and incl 60cm long bras scruees, pointing around urinal back in cement incl and fixing and urinal spreader, flush pipe, grating with coupling and union for discharge complete all as specified |
| 162 | S&F in repair fancy CP centre hole basin mixer (Swan Neck) of Make Jaquar Cat No FLR-5167NB or Kohler or Cera suitable for fixing to 15mm bore (dia) GI Pipe, complete as all specified and as directed. |
| 163 | S&F steel ventilator 1.25 mm thick Box type (primer coated) ERW hollow 'P' section of size 60 mm x 25 mm single rebated comprises of glazed sutter EWR sec 50 mm x 20 mm and 1 mm thick and two openable leaf consisting two Nos sash bar of 'T' section 20 mm x 3 mm complete welded to frame with one vertical mullion of EWR bot 'T' section of size 60 mm x 25 mm and 1.25 mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1, four Nos for each window including following fittings welded to failed shutter:-(a) Holdfasts 150 mm long 12mm x 3 mm made to shape- 4 Nos per window(b) Handle of Z sec 20 mm x 25 mm, 100 mm long - 1 nos per leaf.(c) MS tower bolt 150 mm long - 2 Nos per leaf.(d) 'Z' sec 20 mm x 25 mm , 100 long stopper-01 Nos per leaf,(e) Cleat 55mm long of hollow square 15 mm x 20 mm x 63 mm welded to hinges - 1 Nos per leaf(f) MS pintal hinges of size 75 mm x 12 mm - 2 Nos per leaf.(g) fabrication and fixing arrangement complete.Note:- Grill / guard bar , glass pane shall be measured and Paid separately |
| 164 | All as per Srl item No. 163 here-in-before but in gauged shutters without sash bars all as specified and as directed. |
| 165 | Taking down carefully existing point wiring of any type/ any size (i.e. on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light and for taking credit of unserviceable light as per Sch of credit and making good disturbed surface of walls, roof, floors etc. with any type of civil work involved complete all as specified and as directed. |
| 166 | M&L for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes (min 50 mm deep and 1.6 mm thick sheet) duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed. by Engineer-in-Charge.Note : No more than 06 point on one circuit and separate conduit will be used for power circuit and light point circuit as per NBC code 2016 |
| 167 | All as per srl item No. 166 here-in-before but for one Fan point controlled by one switch complete all as specified |
| 168 | All as per srl item No. 166 here-in-before but for one bell point controlled by one bell push complete all as specified. |
| 169 | All as per srl item No. 166 here-in-before but for one light point controlled by two way switches complete all as specified. |
| 170 | All as per srl item No. 166 here-in-before but for one socket outlet 5 Amps on independent board complete all as specified. |
| 171 | All as per srl item No. 166 here-in-before but for one socket outlet 5 Amps on the same board controlled complete all as specified. |
| 172 | All as per srl item No. 166 here-in-before but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and as directed. by Engineer-in-Charge. |
| 173 | S&F in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified. |
| 174 | S&F switch piano flush type, 6 Amps, 240 Volt AC single pole, one way complete all as specified. |
| 175 | S&F in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, two way complete all as specified. |
| 176 | S&F in replacement switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified. |
| 177 | S&F in replacement socket out let 5 Amp, 5 pin flush type complete all as specified. |
| 178 | S&F socket out let 6 Amp, 5 pin flush type complete all as specified. |
| 179 | M&L in replacement Socket outlet multi purpose 2 in 1, 5/6 pin, 5 & 15 Amps, flush type complete all as specified. |
| 180 | M&L in replacement Bell push switch, flush type 5 Amps, SP, 240 volts complete all as specified. |
| 181 | M&L in replacement Bell electric AC (Ding Dong) 240 volt SP complete all as specified. |
| 182 | S&F in repair lamp holder insulated body with matching colour back plate all as specified and as directed. |
| 183 | S&F lamp holder insulated body with matching colour back plate all as specified and as directed. |
| 184 | S&F five step fan regulator, electronic type, single phase, including connection complete all as specified. |
| 185 | S&F in repair ceiling rose surface type bakelite 65 x 50mm, three terminal complete all as specified. |
| 186 | S&F ceiling rose surface type bakelite 65 x 50mm, three terminal complete all as specified. |
| 187 | S&F in repair wall mounted decorative light suitable for B-22 LED lamp and Including LED lamp warm white 9 W ISI marked sample approved by GE complete all as specified and as directed. |
| 188 | S&F in replacement LED retrofit lamp 9 W, 6500K, 220-240V with base cap B-22 complete all as specified and as directed. |
| 189 | M&L in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm (as specified) complete with any type of civil work involved to make good disturbed surfaces all as specified.Note : Two run of 6 sqmm wire and one run of 6 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit |
| 190 | M&L in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm complete with any type of civil work involved to make good disturbed surfaces all as specified.Note : Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit |
| 191 | M&L in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 2.5 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 2.5 Sqmm complete with any type of civil work involved to make good disturbed surfaces complete all as specified.Note : Two run of 2.5 sqmm wire and one run of 2.5 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit |
| 192 | S&F in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessity complete all as specified and as directed. by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ |
| 193 | M&L for sheet metal DB for MCBs, SPN, 8 ways, double door, single phase, with bus bar, neutral bar/ connectors suitable copper thimbles, lugs etc complete all as specified.Make: EKINOX3 series of Legrand/Acti 9 metalic series of Schneider/Optipro of Indoasian/Osafe of HPL/Metallica of Havells or equivalent in Hager/ Siemens/ Bch |
| 194 | S&F in repair MCB SP 6 to 32 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed. by Engr-in-charge |
| 195 | S&F MCB SP 6 to 32 Amps, 10 KA, B curve as per Osafe series of HPL/ Acti 9 series of Schneider or equivalent in Optipro of Indoasian/ Havells/ Siemens/ Bch. complete all as specified and as directed. by Engr-in-charge |
| 196 | S&F MCB SPN 32 Amps, 10 KA, B curve as per Osafe series of HPL/ Acti 9 series of Schneider or equivalent in Optipro of Indoasian/ Havells/ Siemens/ Bch. complete all as specified and as directed. by Engr-in-charge |
| 197 | S&F in repair MCB SPN 40 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed. by Engr-in-charge |
| 198 | S&F exhaust fan, steel body AC single Phase. 230V of size 225/230 mm sweep with, blades, and frame and louvers (louvers made of powder coated frame having aluminium/ GI sheet flappers) complete including making/ cutting of hole in wall of any thickness and making good to disturbed surface complete incl plastering all as specified and as directed. |
| 199 | S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers (louvers made of powder coated frame having aluminium/ GI sheet flappers) complete including making/ cutting of hole in wall of any thickness and making good to disturbed surface complete incl plastering all as specified and as directed. |
| 200 | S&F energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and as directed. by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 201 | S&F energy efficient LED Bldg security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and as directed. by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)(q)LED source : Hi power LED 3 to 5W High power type |
| 202 | S&F 10 watt LED bulkhead having LED strip & inbuilt driver, aluminium housing with opal/ polycarbonate diffuser including taking out old fitting all as specified and as directed.. |
| 203 | S&F in replacement Deco Ultra Slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 20W LED 6000K complete all as specified and as directed.. |
| 204 | S&F in replacement LED tube light fitting polycarbonate housing 1 x 10 Watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and as directed. by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 205 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amp 240 V 10 KA complete all as specified and as directed. |
| 206 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 16 amp 240 V 10 KA complete all as specified and as directed. |
| 207 | S&F ceiling Fan BLDC motor (Brushless Direct Current Motor) complete with blades, down rod, & accessories. The fan shall be regulator operated. Voltage shall be 230V & rated frequency shall be 50 Hertz. Rated power input shall be 25 to 30 W and RPM shall be 350 +/- 10%. Rated Air delivery shall be min. 225 cubic meter per min. Service value CMM/W shall be graded to 7.00. It shall be copper binded with aluminium blades. Fan shall be BEE 5 star rated |
| 208 | Fixing only serviceable tube light fittings any type and any description retrieved under item Srl No. 165, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as specified and as directed. |
| 209 | M&L in replacement XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete laid in trenches passing through pipes/culverts/ under roads/ along wall all as specified and as directed. by Engineer-in-charge |
| 210 | M&L for XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete laid in trenches passing through pipes/culverts all as specified and as directed. by Engineer-in-charge |
| 211 | M&L for Surface dressing n.exc 15 cm deep in soft/ loose soil including removing bushes/ small trees etc complete all as specified |
| 212 | Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in soft soil, complete all as specified and as directed.. |
| 213 | M&L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed..(Surplus soil if any shall not be removed but left over the trench) |
| 214 | M&L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed.. |
| 215 | Removing excavated material to a distance exceeding 1.5 km but not exceeding 5.0 km and depositing out of defence land complete all as specified |
| 216 | M&L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified.Note : For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR part-I. |
| 217 | Supply and laying old size sub class 'B' bricks laid flat in trenchs over the cable with the length of brick perpendicular to the direction of cable length, compressive strength of brick shall not be less than 75 kg/cm² adjacent/abutting each other complete all as specified and as directed. by Engineer-in-Charge |
| 218 | S&F powder coated sheet metal enclosure indoor type ( size suitable for having 8 Nos meter compartments, bus bar chamber, cable connection chamber) made out of 2mm thick CRCA sheet having independent compartments 08 Nos of size width1500 mm x height1200 mm x depth 200 mm for single phase energy meters and MCB’s provided with front hinged shutters with locking arrangements and clear glass to visualize the meter reading without opening the compartment with sufficient working space in compartment; duly prewired with single core PVC insulated and sheathed FRLS stranded copper conductor wire of suitable size from bus bar to meter compartment 08 Nos duly crimped with copper thimbles, duly powder coated having one number cable gland for suitable size of LT XLPE/ PVC cable entry at bottom complete all as specified and as directed. and consisting with the following:- (a) Bus bar for 3 phase 4 wire system of 4 x 100 Amps rated insulated copper strip mounted on resin cast insulators in independent compartment having front open able shutter - One Set.(b) MCB, four pole, 415 volts, 100 Amps- 01 No, 16 KA with, ICS=ICU=100% including spreader links on both sides-One No.(c) MCB SPN, 63 Amps, 10 KA C-curve-08 Nos.Note:- Existing meters shall be dismantled & re-fixed in panel by contractor and make cable connection properly through LT cable joint with lugs of suitable size rates are deemed to include for the same. |
| 219 | M&L for Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2020 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved.all as specified and as directed. and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner. |
| 220 | S&F electric water heater, storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV etc. complete all as specified and as directed. |
| 221 | S&F LED lights fitting 1x 20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 222 | S&F GI pipe light grade ISI Marked of size 25 mm dia bore for cable protection under road/floor/wall along the pole including fittings complete all as specified and as directed. by Engr-in-Charge.Make : TATA/Jindal/Ravindra |
| 223 | Supply and lay pipe galvanized 20 mm bore, “Medium grade”, including reqd fittings like socket, union, elbow, bend, tees etc. jointed and laid and fixed in wall complete all as specified and as directed. by Engr-in-charge |
| 224 | M&L for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm bore all as specified and as directed.. |
| 225 | M&L for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm bore complete all as specified and as directed. by Engineer-in -Charge |
| 226 | Cutting existing GI tubing of size 25 to 32 mm dia in position at two sections for taking new connection including making thread on pipe in position, inserting new Tee provision and fixing of union complete jointing the cut pipe complete all as specified and as directed. by Engineer-in -Charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy