| 1 | =B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) R&D RCI HYDERABAD Name of Work: REPAIR TO ROOF TREATMENT, JOINERY, TILING OF CERTAIN BLDG IN TECHNICAL AREA OF ZONE-I AND CERTAIN BLDG TAKEN OVER FROM CCE AT RCI, HYDERABAD UNDER GE (I) R&D RCI HYDERABAD Contract No: GE(I) RCI/HYD/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic Rate In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount With Taxes Total Amount In Words |
| 2 | Taking down existing roof treatment including scrapping old bitumen layer complete of any description and removing of cement plaster including cleaning and disposal of debris off the premises at low laying area asdirected by Engineer in charge complet. |
| 3 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing debris at low laying area all as directed by Engineer in charge. |
| 4 | M&L, PCC 1:2:4, type B-0 using 12.5mm graded stone aggregate as in padding concrete/levelling course, to maintain slopes on roof and finishing the surfaces fair and even including necessary formwork and other similar work complete all as specified and directed. |
| 5 | M & L, PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate)as in roof kerbs or covering rounded or chamfered on edges all as specified. |
| 6 | M& L 15 mm thick Cement plster in CM 1:4 on fair faces of brick work or Concrete surfaces, Mixing with water proofing chemical (WPC will be measured and paid separetely) over neat cement slurry @250ML/ bag cement on old concrete Surfaces. |
| 7 | M & L for preparation of concrete surfaces by brushing, cleaning and washing all the undulations, cracks, pores ,cleaned and sealed with PU sealant or Make grue and applied Repair polymer (SBR Technology) alongwith ready mix plaster filled crack and seal properly thereafter apply 1st coat of Damp Proof Ultra @ 700gram/Sqm (laying 30-40 GSM Geotextile with 50mm side and end over laps on the layers wherever required and will be measured and paid seperately) and apply 2nd coat of Damp proof Ultra over all surfase @500 grams/Sqm all as specified and as per manufacurers instructions and as directed Brand: Asian/Foxroc/Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge |
| 8 | Supply only Geotextile 30-40 GSM Complete all as per manufacturers instructions |
| 9 | M&L, cutting open to 'V' grove with the help of machine on all visible cracks of external wall/roof over 0.5mm size, cleaning thoroughly and filling with smartcare Hybrid PU sealant complete as per manufacturer instructions and as directed.Make : Asian Paints/FOSROC/ Pidilite Note . The work shall be got executed directly by manufacturer or their authorized applicator after obtaining prior approval from GE. |
| 10 | M&L for water proofing treatment on existing cleaned RCC roof comprising with the following operation as specified here-in-below:-a) Applying evenly one coat of cold bituminous primer conforming to IS-3384-1986, @ 0.30 litre per square metre on the Cleaned Plastered Surfaces.b) Applying evenly one Coat of blown Hot Bitumen of Grade 85/25 @ 1.20 kilogram per square metre on primed surfaces.c) S&F standard APP modified membrane prefabricated 5 layer 3mm thick with non woven polyster matt centeral core of 160 gsm (mini) impregrnated and coated on both sides with layers of APP modified bitumen and finised with micro perforated heat fusiable polythene film on both surfaces .the weight of membrane shall not be less than 3.5kg/sqm and laid over primed surface by LPG/ butane torch, all as per manufacturers instructions.(d) Applying evenly one Coat of blown Hot Bitumen of Grade 85/25 @ 1.20 kilogram per square metre over membrane surfaces. |
| 11 | M & L Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizantal faces of grooves with cement mortar in CM 1:3 and making good in CM 1:3 after inserting membrance in to the groove. |
| 12 | M & L for Preparation of old plastered surfaces of External walls in different locations and at any height, contaminations, fungus and other micro organism growth shall be removed by mechanical means. Supply and applying two coat of self prime Smartcare Damp proof Ultra in wall/Ceilling in two coats, Ist coat with using water @33% by weight and 2nd coat without dilution therafter apply two coat of apex ultima over damp proof surface complete as per manufacturer specifications and instructions. Brand: Asian/Foxroc/Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge |
| 13 | M & L for Preparation of old plastered surfaces of internal wall, in different locations and at any height, contaminations, fungus and other micro organism growth shall be removed by mechanical means. Supply and applying Damp block-2K two coats @ 1.50Kg/Sqm in two coats. Once the coating is cured, apply a single coat of epoxy triblock 1Kg/2 Sqm therafter apply two coat of Oil bound distemper over damp proof surface. complete as per manufacturer specifications.Brand: Asian/ Foxroc/ Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge |
| 14 | M & L for all the visible cracks of external wall/roof over 0.5mm size has to be cleaned properly & the same has to be cut open to 'V' grove with the help of machine and the same has to be filled with smartcare Hybrid PU sealant complete as per manufacturer recommendations. Brand: Asian/Foxroc/Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge |
| 15 | Taking down cement plaster of any description on brick or stone walls from any height including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed. |
| 16 | Supply only Liquid water proofing chemical of pedelite/Doctor fixit or equallent (ISI Marked) complete |
| 17 | Demolition of brickwork or stone/boulder masonary built in cement mortar including all quoins,arches,pillars,etc, but excluding ashlar facing, dressed stonework and precast concrete articles. |
| 18 | M&L, brickwork with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 19 | M&L rendering 15mm thick in CM 1:4 over brick work or concrete surface and finished the rendering surfaces even and smooth without using extra cement. |
| 20 | M&L Preparing new plastered surfaces of wall and and applying Two Coats of Distemper Oil Emulsion over a coat of alkali resistant primer and applied over 2mm thick BIRLA/JK water proof wall care putty complete all as specified and as directed. |
| 21 | M&L for preparation of new/old plastered surfaces of walls and applying two coat of exterior weather proof paint (Apex Ultima of M/s Asian Paints / weather coat smooth of M/s Berger paint / weahter max exterior acrylic of M/s ICI Dulux) over a coat of primer over one coat of putty and as per manufacturer's instructions, complete all as specified and directed. |
| 22 | Taking down rainwater pipes (any size or pattern) fixed to walls, including all fittings, heads, shoes, bends, swan necks, etc., (measured overall as fixed along the centre line over fittings and accessories), complete all as directed. |
| 23 | S&F, 160mm dia PVC(SWR) pipes, ISI marked, single socketed in any length with rubber ring joints fixed to walls with PVC clamps as rain water pipe complete including removing all loose packed plaster/cement mortar around the pvc pipe, making good and water tightened around the pipe and making proper slope to troughed portion using cement mortar 1:2(using water proofing liquid) to flow water into the PVC rainwater pipe properly from roofall as specified and as directed. |
| 24 | S&F, 110mm dia PVC(SWR) pipes, ISI marked, single socketed in any length with rubber ring joints fixed to walls with PVC clamps as rain water pipe complete including removing all loose packed plaster/cement mortar around the pvc pipe, making good and water tightened around the pipe and making proper slope to troughed portion using cement mortar 1:2(using water proofing liquid) to flow water into the PVC rainwater pipe properly from roofall as specified and as directed. |
| 25 | S&F, 75mm dia PVC(SWR) pipes, ISI marked, single socketed in any length with rubber ring joints fixed to walls with PVC clamps as rain water pipe complete including removing all loose packed plaster/cement mortar around the pvc pipe, making good and water tightened around the pipe and making proper slope to troughed portion using cement mortar 1:2(using water proofing liquid) to flow water into the PVC rainwater pipe properly from roofall as specified and as directed. |
| 26 | S&F, 160mm bore PVC(SWR) bends any radius with access door complete all as specified and as directed. |
| 27 | S&F, 110mm bore PVC(SWR) bends any radius with access door complete all as specified and as directed. |
| 28 | S&F, 75mm bore PVC(SWR) bends any radius with access door complete all as specified and as directed. |
| 29 | Disconnecting existing tanks of capacity exceeding 500 litres and not exceeding 1000 litres setting aside (or lowering if required) for repairs,to make convinient for roo ftreatment cleaning and removing all scale and dirt etc., from tanks and from mouths of circulating pipes and hoisting as required, reconnecting and refixing in position complete all as directed. |
| 30 | Disconnecting existing tanks of capacity exceeding 250 litres and not exceeding 500 litres setting aside (or lowering if required) for repairs, to make convinient for roof treatment cleaning and removing all scale and dirt etc., from tanks and from mouths of circulating pipes and hoisting as required, reconnecting and refixing in position complete all as directed. |
| 31 | S&F in repairs, 500 litres capacity triple layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including connecting up of existing inlet and outlet pipes and ball valve complete all as specified and as directed. |
| 32 | S&F in repairs, 1000 litres capacity triple layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including connecting up of existing inlet and outlet pipes and ball valve complete all as specified and as directed. |
| 33 | S&F, 20mm bore premium PTMT Ball valves, high pressure, with epoxy coated aluminium rod and high density plastic ball and fly nut complete, screwed for iron/GI pipe or brass ferrule complete all as specified and directed.Make:Prayag CAT No152 or equivalent as approved by GE |
| 34 | S&F 25mm bore premium PTMT Ball valves, high pressure, with epoxy coated aluminium rod and high density plastic ball and fly nut complete, screwed for iron/GI pipe or brass ferrule complete all as specified and directed.Make:Prayag CAT No153 or equivalent as approved by GE |
| 35 | Taking down chowkhat or frames (without taking off shutters from the frames) not exceeding 1.5Sqm complete all as directed. |
| 36 | Taking down chowkhat or frames (without taking off shutters from the frames) exceeding 1.50 Sqm but n. exc 4.00 Sqm each complete all as directed. |
| 37 | Taking down shutters of any description from the frames exceeding 1Sqm but not exceeding 2Sqm complete all as directed. |
| 38 | S&F unplasticised Poly Vinyl Chloride (UPVC) 3-Track Panel Sliding Window Fusion welded joints (2 Glass Shutters, 1 SS Mesh Shutter) of 88mm x 52mm x 2.20mm with reinforcement of 1.2 mm thickness, Super sash with overall size 42mm x 60 mm x 2.20mm with reinforcement of 1.5 mm thickness for sliding window shutter frames capable of mounting glazing bead of appropriate dimension including 4-5 mm thick tinted glass and stainless steel wire cloth, 0.36 mm nominal dia and average width of aperture 1.40 mm including locks and handles ( up to 3 story building including all necessary scaffolding if required complete ),. after fixing frame the gap between frame and the ajjacent wall shall be filled with weather proof silicon sealant complete all as specified and directed ( fixed part of window shall be measured and paid seperatly in respective item.. |
| 39 | Ditto but fixed type with 4.80mm thick tinted glass, gasket etc complete all as directed. |
| 40 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed. |
| 41 | S&F in repairs Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing conforming to Fe 290 Gde-E-165 complete all as specified and as directed. |
| 42 | M & L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by EIC. |
| 43 | All as per Item No 41 above but MS Plate (Plain or Chequred). |
| 44 | Dismantling plain or corrugated steel sheeting, any gauge or thickness incl Nainital or similar pattern roof coverings all as specified and directed. |
| 45 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, fixed with self tapping screws as specified. |
| 46 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, valley gutter, ridge and fixed with crumple joint etc fixed with self tapping screws all as specified and directed. |
| 47 | M&L for Fibre glass reinforced translucent corrugated sheeting 2 mm thick with two corrugations side lap fixed with coach screw/self taping screw and washer in roof, wall and crumple joits etc. |
| 48 | S&F of fixed louvered ventilator made out of multi chambered uPVC sections fusion welded joints with glazing bead with EPDM black gasket having isolated drainage and reinforced with galvanized iron profiles throughout the window. The outer frame having an overall size of (60mm x 36mm x 2.2mm)/(60mm x 58mm x 2.2mm) with reinforcement of 1.2mm thickness including 5mm thick frosted glass and stainless steel wire cloth, 0.36 mm nominal dia and average width of aperture 1.40 mm fixed complete all as specified and directed. |
| 49 | Supply & Fix in repair aluminium Powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators , sliding shutters, partition etc. with one or more rebates including joining cleat for fixing , sliding roller , locking arrangement etc fixed in any height complete all as specified and directed. Note :- Glass , wire mesh, and EPDM gasket shall be measured and paid under respective item. |
| 50 | S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, fixed complete all as specified and directed. |
| 51 | S&F EPDM washers for fixing glass complete all as specified and directed. |
| 52 | M&L for Sheet glass 4.5 mm thick, ordinary quality tinted glass exc 0.5 sq. m in each pane all as specified and direcfted. |
| 53 | M&L figured glass 4.5 mm thick pin head type and glazing with glazing clips n. exc 0.5 sqm in each pan complete all as specified and directed. |
| 54 | M&L for 12 mm Pre laminated particle board interior grade both sides laminated fixed to frame complete all as specified and directed. |
| 55 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises all as specified and directed. |
| 56 | M&L, 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring, finishing the surface even and smooth using extra cement including necessary formwork complete all as specified and directed. |
| 57 | M&L, light coloured vitrified tiles ( double charged ) in floors of size 600 x 600 x 8 to 9 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including screed bed or bedding layer 15mm thick in CM 1:4 complete all as specified and as directed complete all as specified and as directed. |
| 58 | M&L, 9 to 10mm thick light coloured vitrified tiles in skirting of size 600 x 100mm, set and jointed in neat cement slurry and pointed in coloured cement to match shade of tile over and including 10mm thick backing coat in CM 1:3 complete all as specified and as directed. |
| 59 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, aluminium fram or stone, concrete or brick surrounds, glazed with putty or fixed with beads. |
| 60 | M & L for Solar control film 25 micron reflective type (gareware sun control or equivalet) including removing old film preparing surface to receive new fim complete all as specified and directed. |
| 61 | S & F in repairs for Door closer hydraulically regulated cast iron body,designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed |
| 62 | S & F in repairs of Roller/ Venetian Blinds vertical/Horizontal type made out of standard cloth of approved texture with necessary accessories etc. complete all as specified and directed by Engineer in charge. |
| 63 | M & L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed after takingdown and refix of door. (Note :- Rate of taking down and refix of door is includes of quoted rates.) |
| 64 | M & L for mortise lock with a latch, vertical type size 100 mm, 4 levers.All as specified and directed . |
| 65 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, ACP etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets , wooden scanteling . |
| 66 | S&F in repairs, mild steel framed work such as grills, gratings etc., frame work to receive clading ,guard bars and similar works using any sectioc hollwo or solid conforming to Fe 290 Gde-E-165 complete all as specified and as directed. |
| 67 | S&F mineral fibre acoustical suspended ceiling system with Mina Tuff (Micro look) edge tiles with silhouette exposed grid. The tiles hold have humidity resistance (RH) of 99%, NRC upto 0.6, light reflectance 88%, Thermal conductivity K=0.052-0.057 w/m K, colour white, fire performance Class-I (BS476 Part 6 & 7) in module size of 600 x 600 x 16mm with bio black coating on the face of the tile, impact resistant and suitable for green building application, with recycled content of 63%, Tile shall be laid on Silhouette profile grid system with 15mm white/black colour and with a web height of 38mm and having load carrying capacity of minimum 11.68 Kgs/Sqm, Silhouette, Main runner and Cross tees to have mitred ends and Birds mouth notches to provided mitred cruciform junction complete all as specified and directed. Make: Armstrong, Saint Gobain, Diomond |
| 68 | M&L 11-12mm thick gypsum board in false ceiling fixed with screws as per manufactures specifications including applying one coat of putty, rubbing/grinding with sand paper and making smooth and even surface and applying one coats of distemper oil emulsion over a coat primer complete all as directed.Make: Saint Gobain or equivalent as approved by GE. |
| 69 | S&F, Fine Fissured RH99 Armstrong ceiling tile of size 600 x 600 x 12/16mm thick as per approved pattern complete all as directed. |
| 70 | S&F in repair 3 mm thick Aluminium Composite panel cladding plain metallic of approved colour / shade to beam/column/slab in circular/rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour complete all as specified and as directed. |
| 71 | M&L for cleaning old bituminous surface of Cemet Concrete/Cement tiles on roof / chjjas and applying two coats of cold bitumen in patches upto 5sqm at different locations complete all as specified and directed . |
| 72 | Cutting/derooting of small plants/shrubs (girth exceeding 5cm and not exceeding 15cm) applying concentrated acid to stop plant growth and cleaning of surface free from dirt/ dust/ dry leaves/ mud etc., making good disturbed wall/flooring surface with PCC 1:2:4 type B0, using 12.5mm graded stone aggregate or in cement mortar 1:3 as per site requirement including disposable of unserviceable material to a distance not exceeding 50m all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |