| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: HQ CWE (AF) NAGPUR Name of Work: PROVISION OF POWER SUPPLY FOR CHARGING STATION OF ELECTRICAL VEHICLES AT VSN NAGPUR Contract No: CWE (AF) /OJH / OF 2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE inclusive of all taxes in Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Quoted Amount in Words Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Supply and fix cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE insulated armoured aluminium conductor cable of size 95sqmm complete all as specified and as directed. |
| 3 | Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE insulated armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. |
| 4 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm. complete all as specified and as directed. |
| 5 | Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 Volts grade, 3.5 core 300 sqmm complete all as specified and as directed. |
| 6 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed |
| 7 | Returning Filling in including spreading, leveling, watering and well ramming in layers n. exc 25 Cm, complete all as specified and directed |
| 8 | Removing excavated/Surplus soil n exc 50 M and depositing where directed at a level n. exc 1.5 Mtr above the starting point, complete all as specified and directed |
| 9 | Material and labour for laying of fine, clean sand (river sand) free from sharp materials in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning for cable in trenches/cable ducts , complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning complete all as specified and directed |
| 10 | Supplying and laying reinforced precast concrete cable cover, class HV, type 1 with peak, size 300 mm x 180 mm x 40mm , complete all as specified and directed |
| 11 | Supply and installation of copper wound transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire Oil Immersed Outdoor Type level 2 Distribution Transformer with +5% to -10 % in steps of 2.5% by off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity upto 315 KVA with Specifications below:-(a) Number of winding - 2 Nos(b) Installation type - Outdoor(c) Cooling type - ONAN(d) Termina Arrangement - Bare Bushing fo HV & Cable Box for LV Side(e) Vector Group - Dyn 11(f) Ambient Temperature - 50°C(g) Temperature Rise of Oil - 40°C(h) Temperature Rise of Winding - 45°C(j) Impendance - 4.50% (Subject to +/- 10% Tolerance)(k) Transformer Oil - 'A Grade' tested & certified as per IS 335 Standard(l) Total Losses at 50% load - 955 Watts(m) Total Losses at 100% load - 2750 Watt(n) Copper - Pure Electrolytic Grade(o) Tapping Mode - +5% to -10% in steps of 2.5% by Off Circuit Tap(p) Basic Insulation Level for HV - 75 KV peak / 28 KV ms(q) Basic Insulation Level for LV - -/3 KV ms |
| 12 | M & L for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground ( earth pit not less than 2.25 meters deep below ground level) with to edge of the plate not less than 1.5 Mtrs below normal ground level connected to GI earth strip of 25 x 4mm by means of bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of SSR Part I - 1991 complete as specified including excavation and earth work in any type soil, PCC pit (1:3:6) type C-I in cement concrete 40mm thick precast RCC cover in (1:2:4) type B-1 reinforced with 8 mm dia MS round bar @ 75 c/c both ways with 01 No lifting handle of 12mm dia MS plain bar, GI pipe 32mm dia light grade for earth strip protection up to 7.5 mtr and GI tubing 20mm for watering including GI funnel with wire mesh etc complete all as specified and directed. Note:- GI strip of size 32 x 6 mm beyond 7.5 meters shall be measured and paid seperately. |
| 13 | M&L for earthing lead by using galvanised iron 32x6 mm strip all as specified and directed. |
| 14 | Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size1000 mm x 1000 mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories and also including removing old exisisting one complete all as specified and as directed. . NOTE:- Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 15 | INCOMMING :- (a) Copper strip busbar of 800 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos (b) MCCB,4 Pole 630 Amp, 50 KA - 01 No. (c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) Make :- Legrand/L&T/Schneider (d) Digital Ammeter of range (0- 800) Amps, flush mounting type with CT’s of ratio 400/5 and selector switch – 01 set. (e) Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. OUTGOING :- (a) MCCB,4 Pole 630 Amp, 50 KA - 01 No. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150 mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 16 | Supply and installation of ACDB Box of 630 A,FP,36 KA,MCCB complete AL Bus bar with internal wiring of all fixture as CT,LED Lamp and the ACDB Panel box shall be covered with canopy of suitable size all as specified and as directed.The rates of canopy should be deemed included in the qouted rate .Description of ACDB as follow :- 4P MCCB 36KA TM BASED HAVING O/L,S/C RELEASE 630A - 01 ROTARY OPERATING MECHANISM FOR ABOVE - 01 96SQ.MM DIGITAL MFM WITH RS-485 PORT, CL-0.2 5A - 01 TAPE WOUND CURRENT TRANSFORMER, CL-0.2, VA-15 600/5A - 03 CT SHORTING TERMINALS - 04 LED PHASE INDICATION LAMP - (RED) 240V AC - 02 LED PHASE INDICATION LAMP - (YELLOW) 240V AC - 02 LED PHASE INDICATION LAMP - (BLUE) 240V AC - 02 SP MINIATURE CIRCUIT BREAKER, 10KA, 'C' SERIES 6A - 06 NEUTRAL LINK - 02 PANEL ILLUMINATION LAMP, 5WATT, 240V AC - 01 6\\" EXHAUST FAN WITH LOUVERS 240V AC - 01 LIMIT SWITCH FOR ABOVE FAN AND PANEL LAMP - 01 5A PLUG AND SOCKET WITH SWITCH 240V AC - 01 Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |