| 1 | Dismantling asbestos cement sheet (corrugated or semi corrugated etc) including ridges in large patches as in roof covering complete all as specified and as directed.Note:- Dismantling existing wind tie and refixing the same where required for taking down of sheets shall deemed to be included in the unit rate quoted . |
| 2 | S&F prepainted galvalume aluminium zinc coated galvanised iron based corrugated steel sheets 0.5 mm thick of any colour having tensile strength 550 MPA as in roof covering or ridges with side lap and end laps, hips and straight flashing fixed with self taping screws (length & girth as fixed) complete all as specified and as directed. Note:- Colour & Pattern to be approved by Engineer-in-Charge. |
| 3 | S&F pre-painted galvalume aluminium zinc coated galvanised Iron based Plain steel sheets, 0.5mm thick of any colour with side lap and end lap having tensile strength 550 MPA as in ridges, hips, valley gutters, drip and straight flashing fixed with self taping screws (length & girth as fixed) complete all as specified and as directed. |
| 4 | S&F 6mm thick, Asbestos cement corrugated or semi corrugated sheets in roofs, walls etc, fixed with L or J type or cranked hook bolts complete all as specified and as directed. |
| 5 | S&F 6mm thick Asbestos cement two piece serrated ridge for corrugated or semi corrugated sheets, fixed with L or J type or cranked hook bolts complete all as specified and as directed |
| 6 | S&F laminated Gypsum tile board 8mm thick with textured white colour PVC film on the face side and metalized polyster (MPL) film on rear side in ceiling as per manufacturers instructions of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm |
| 7 | and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, including dismantling existing false ceiling work of any description all as specified and as directed. |
| 8 | Dismantling of mangalore pattern or similar tiles in roofing including ridge tiles complete all as specified and as directed. |
| 9 | Dismantling battens for tiles, shingles etc, of any size including tilting fillets, spaced exc 15 cm complete all as specified and as directed. |
| 10 | M&L for second class hardwood clean sawn batten, sectional area exc 5 sqcm & n.exc 15 Sqcm fixed at spacing of 30cm centres complete all as specified and as directed |
| 11 | Fixing only old clean sawn batten at spacing 30cm centre of second class, hardwood complete all as specified and as directed.Note : Old serviceable battens obtained from dismantling shall be reused. |
| 12 | M&L for roof tiles mangalore pattern Grade AA, interlocking at side joint laid dry complete all as specified and as directed. |
| 13 | Fixing only old roof tiles mangalore pattern, interlocking at side joint laid dry complete all as specified and as directed.Note : Old roof tiles mangalore pattern obtained from dismantling shall be reused. |
| 14 | M&L ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed. |
| 15 | Fixing only ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.Note : Old ridge tiles obtained from dismantling shall be reused. |
| 16 | M&L for preparation of new wood and wood based surfaces of tiles battens any size and spacing, prepared and treated all over with two coats of creosote oil (measured overall on one side only, spaces not deducted) complete all as specified and as directed. |
| 17 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 18 | S&F galvanised corrugated mild steel sheeting, 0.63 mm thick, with two corrugations side lap, fixed with coach screws and washers, in roofs, wall etc. with grade of zinc coating 275, complete all as specified and as directed. |
| 19 | All as per serial item No. 17.00 here-in-before but except sheets |
| 20 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 21 | M&L for second class hard wood boarding planed one side with edges tongued and grooved or rebated, 15 mm thick as in eaves board/ barge board etc. complete all as specified and as directed. |
| 22 | M&L for preparation of new wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 23 | Dismantling timber scantlings 40 sqcm and over in section, in any position, framed work, complete all as specified and as directed. |
| 24 | M&L for second class hard wood scantling, wrought, fixed in position complete all as specified and as directed. |
| 25 | M&L for preparation of new wood and old wood based surfaces, of any description and girth not otherwise described and treated with two coats of creosote oil complete all as specified and as directed. |
| 26 | M&L in repairs, for water proofing treatment to RCC roof slab, including parapet, comprising with the following treatment/specification from bottom to top:-(a) Taking down existing roof treatment of any type and any thickness including mud in roofs, plastering, leaping plaster of any thickness cutting & uprooting trees /roots / vegetation growth & removing the debris from the site premises outside MoD land.(b) Cleaning existing surface properly including roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc(c) Screed bed or bedding layer of 10 mm thick cement mortar 1:4 with mixing of WPC @ 3% by weight of cement or as per manufacturers instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. |
| 27 | (d) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986.(e) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(f) Applying two coats of bituminous aluminium paint over APP membrane @ 0.11kg/sqm.Note: Water proofing compound shall be measured & paid separately. |
| 28 | Supply only liquid water proofing compound complete, ISI mark all as specified and as directed. |
| 29 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed. |
| 30 | S&F Steel work in Rolled sections section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 31 | S&F mild steel framed work such as grill, gratings, guard bars etc with end of bars shouldered and/or riveted or forged into spikes, ladders, iron doors, balusters, railings and similar works conforming to Fe.290, Gde-E-165 complete all as specified and as directed. |
| 32 | S&F Mild steel work as in wind ties for roof including securing bolts complete including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 33 | Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 34 | M&L for providing cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) in foundations, mass concrete and filling along edges of paver blocks complete all as specified and as directed . |
| 35 | S&F in repair, 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints and fixed to walls complete all as specified and directed. |
| 36 | S&F in repair, 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints and fixed to walls complete all as specified and directed. |
| 37 | S&F in repair, 110 mm bore PVC (SWR) bends any radius complete as directed. |
| 38 | S&F in repair, 75 mm bore PVC (SWR) bends any radius complete as directed. |
| 39 | S&F steel rolling shutter, without ball bearing, as specified including top cover and choring rod, hasp and staple and one shop coat of primer, erected in position as indicated, push pull or manual type, thickness of laths 1.25 mm, including taking down old shutters, complete all as specified and as directed. Note : BOO shall be ordered to ascertain the weight of old shutters to be given on credit. |
| 40 | S&F steel rolling shutter, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer,erected in position as indicated, complete gear operated type with bevel gear box and crank handle, thickness of laths 1.25 mm, including taking down old shutters, complete all as specified and as directed.Note : BOO shall be ordered to ascertain the weight of old shutters to be given on credit. |
| 41 | Repairs to mild steel rolling shutters, area not exc 20 Sqm each including greasing, oiling, etc., and making smooth functioning including taking down if required and fixed in position complete all as specified and as directed. |
| 42 | Repairs to mild steel sliding doors of size 2.3m x 3.8 m (Approx weight 205 Kg per shutter) including greasing, oiling, etc of rollers, replacement of angle iron supports including taking down, refixing in the old position and making the doors in smooth operating condition including all necessary scaffolding, crane supports etc complete all as specified and as directed .(Note: New angle iron supports, rollers etc fixed in replacement shall be measured and paid seperately) |
| 43 | S&F mild steel work as in bands, straps, support for rain water pipes etc conforming to Fe 290 Gde-E-165 complete all as specified and as directed. |
| 44 | S&F in repairs, rotational moulded polyethylene water storage tanks Triple layer (cylindrical vertical with closed top) of 500 litres capacity hoisted and fixed in position, including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting all as specified and as directed. |
| 45 | S&F in repairs, rotational moulded polyethylene water storage tanks Triple layer (cylindrical vertical with closed top) of 1000 litres capacity hoisted and fixed in position, including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting all as specified and as directed. |
| 46 | S&F in repair float valve PTMT high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe, 20 mm bore compete (Minimum weight 210 gm) complete all as specified & as directed. |
| 47 | Taking up or down 15 mm bore dia GI steel tubing and connections complete all as specified and as directed. |
| 48 | S&F 15mm bore UPVC pipes Sch 40 including fittings, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 49 | Fixing only 15 mm bore GI tubing medium grade with all fitting and fixed complete on walls complete all as specified and as directed. |
| 50 | S&F 20mm bore CPVC pipes SDR 11 & Brass CPVC SDR 11 fittings in trenches, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 51 | Taking up or down 20 mm bore dia GI steel tubing and connections complete all as specified and as directed. |
| 52 | Fixing only 20 mm bore GI tubing medium grade with all fitting and fixed complete on walls complete all as specified and as directed. |
| 53 | S&F 20mm bore UPVC pipes Sch 40 including fittings, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 54 | S&F in repairs 20mm dia gun metal globe or gate valve, wheel head cast copper alloy screwed down light pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, ISI marked complete all as specified & as directed |
| 55 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 56 | M&L for preparation of new steel and iron surfaces of any description not otherwise described not exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 57 | M&L for cleaning of service tank upto 500 ltrs by removing all scale, dirt, silt, mud etc, from tanks and from mouths of circulating pipes including washing of tank internally with bleaching powder after removing scale dirt mud ec from tank and removing algae outside from tank from below bottom of tank and disinfecting tank by spraying sodium hypo chlorite solution in tank writing down date of cleaning on tank by synthetic enamel paint size of alphabet/numerical shall be minimum 7 cm using stencils complete all as specified and as directed. |
| 58 | M&L for cleaning of service tank exc 500 ltrs but n. exc 1000 litres capacity by removing all scale, dirt, silt, mud etc, from tanks and from mouths of circulating pipes including washing of tank internally with bleaching powder after removing scale dirt mud ec from tank and removing algae outside from tank from below bottom of tank and disinfecting tank by spraying sodium hypo chlorite solution in tank writing down date of cleaning on tank by synthetic enamel paint size of alphabet/numerical shall be minimum 7 cm using stencils complete all as specified and as directed. |
| 59 | Disconnecting existing water tanks of 500 litres capacity, setting aside (or lowering if required) for roof repair works, for cleaning of tanks, etc and hoisting, reconnecting and re-fixing in position complete all as specified and as directed. |
| 60 | Disconnecting existing water tanks of 1000 litres capacity, setting aside (or lowering if required) for roof repair works, for cleaning of tanks, etc and hoisting, reconnecting and re-fixing in position complete all as specified and as directed. Please Enable Macros to View BoQ information |