| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description thickness including raking out joints hacking for key scrubbing down with water, complete all as directed. |
| 2 | M&L Rendering 15mm thick in Cement Mortar 1:6 on fair faces of Brick Walls or on Concrete Surfaces, finished fair and even , complete all as specified and as directed. |
| 3 | Ditto all as per Srl item No 2 above but 15 mm thick in CM(1:4) with water proofing compound as per manufacturing struction, complete all as specified and as directed . |
| 4 | M&L plastering 5mm thick in cement mortar (1:3) furnished even & smooth without using extra cement as on ceiling, complete all as specified and as directed. |
| 5 | Dismantiling of concrete by chiselling from RCC members like col, beam parapet, facia, chajja, ceiling etc exposing the reinforcement without disturbing the reinforcement and primed with using Araldite epoxy resins manufactured by M/s ciba Geigy Ltd/ FAIR BOND EP/Sika or other approved manufacture and providing doubing coat of 20mm thick in CM 1:3 including necessary form work and reinforced with chicken wire mesh where reqd and rendering 15mm thick in cement mortar 1:3 at any height, complete all as specified and as directed. |
| 6 | M&L for preparing newly plastered surface of wall and applying two coats of Distemper Oil emulsion over a coat of 2mm thick wall care putty on plastered surface, complete all as specified and as directed. |
| 7 | Complete Removal of existing treatment and preparation of old plastered surfaces of walls and applying two coat of distember oil emulsion over a coat of 2mm thick wall care putty, complete all as specified and as directed. |
| 8 | M & L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and as directed. |
| 9 | M & L for preparation of old decorated plastered or unplastered surfaces and apply one coat of white wash on walls including cornices etc all as specified and as directed |
| 10 | M&L for preprationof newly surfaces of wall and applying three coats of white wash on ceiling, complete all as specified and as directed. |
| 11 | M&L for prepration of old plastered/treated surface of ceiling and applying one coat on white wash on ceiling, complete all as specified and as directed. |
| 12 | M&L for prepration of newly surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed. |
| 13 | M&L for complete removal of existing treatment of old plastered surface of wall and applying two coat of cement base paint, complete all as specified and as directed. |
| 14 | Demolition of cement concrete in ground floor and paving not exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 15 | M & L PCC 25mm thick 1:2:4 type B-0, (using12.5mm graded crushed stone aggregate) and finishing the surface rough and even to receive top layer as under tiles ,stone etc, complete all as specified and as directed. |
| 16 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc .and brushing neat cement slurry with 3 kg of cement per sqm, complete all as specified and as directed. |
| 17 | M & L for machine cut kota stone slab 20 to 25 mm thick as in flooring / stair case landing, laid over & incl. 15mm thick cement screed base in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, complete all as specified and as directed. |
| 18 | M&L for coloured ceramic glazed tiles (premium quality) of size 300x450x7mm thick fixed with neat cement slurry in vertical surface to wall pointing in coloured cement to match over and including 10mm thick plastering in CM 1:4, complete all as specified and as directed. Make:- Somany/ Kajaria/ Johnson. |
| 19 | M & L coloured non skid ceramic tiles (premium quality) 7 to 8 mm (squar/rectagular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white as coloured cement to match 15 mm thick screed bed or bedding layer of cement mortar 1 : 6 for laying of floor finishes, complete all as specified and as directed. Make:- Somany/ Kajaria/ Johnson. |
| 20 | Ditto all as perserial item No 19 above, but in skirting on wall in CM 1:4, complete all as specified. |
| 21 | M&L for water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:-(i) The top surface of the sunken RCC slab shall be laid with cross slope as indicated in drgs towards the spouts. The min thickness of the RCC slab shall be as specified in drg.(ii) PCC 1:1.5:3 fillets at corners with 12.5mm graded aggregate shall be provided.(iii) Plastering in CM (1:3) 15mm thick with WPC on walls as well as on sunken floor finished even and smooth using extra cement.(iv) GI Pipe 40mm dia medium grade be inserted at the end of lateral slope projecting at least 15cm beyond the outer most projected part of the building below the drain pipe upto two storey construction and 25cm beyond two storey construction.(v) After doing the plaster, testing be carried out by ponding (for 72 hrs) the sunken portion before further treatment to the sunken slabs. Any leakage/seepage observed shall be rectified before carrying out water proofing treatment.(vi) Two component Acrylic modified Cementitious coating:- |
| 22 | (aa) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coating and achieve a gripping profile that is clean, dry and free from laitance and dry other form of surface contamination. The installation instructions in manufacture's published literature should be strictly complied with, including but not limited to the following:-(bb) Chipping out any visible cracks in \\"V-Groove\\" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr Fixit 302 SBR latex/ Perma latex SBR/FOSROC Nitabond SBR latex/Asian paint latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required.(cc) Dampen all surfaces immediately ahed of application of Acrylic modified Cementitious coating of sika Top Seal-107/Brush Bond FOSROC/Dr Fixit/STP/CICO.(dd) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified cementitious coating of SIKA Top Seal-107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions. |
| 23 | (ee) Apply glass fabric sheet of SIKA Fab 1/FOSROC/Dr Fixit/STP whilst the first coat is wet.(ff) Once touch dry, apply second coat of Acrylic modified cementitious coating of SIKA Top Seal -107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions on the entire area.(gg) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat.(hh) The waterproofing coating should be taken to a height minimum 300mm above the finished floor level on the vertical surfaces.(jj) It is essential to cure Acrylic modified cementitious coating immediately after application (minimum 6-8hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking.(kk) A protection plaster 12-15mm thick) in CM 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645. Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with SIKA Plastocrete over the applied water proofing coating on horizontal surfaces. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645. |
| 24 | (ll) All the corners and joints should be pretreated with an elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of Make SIKA Seal Tape/FOSROC/Dr Fixit/STP.(mm) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations.(nn) Waterproofing treatment has to be carried out through applicators authorised by the respective manufacturer's and approved by GE.(vii) All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealent.(viii) All CI traps in sunken slab to be enclosed with PCC 1:1.5:3 (Min 15cm) all around. Note: Payment for the treatment shall be made by measuring the floor area only |
| 25 | M&L for PCC 1:7:12 type F-2 (40mm graded brick aggregate) as in filling in sunken floor, complete all as specified and as directed. |
| 26 | Demolition of brick work as in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces, complete all as directed. |
| 27 | M & L for brickwork with fly ash bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge |
| 28 | Ditto all as per serial item No 24 above, but except bricks complete all as specified and as directed. |
| 29 | Demolition of re-inforcment cement concrete in ground floor and paving not exc 15 cm thickness (below or above ground level), complete all as directed. |
| 30 | M&L for repairing of R.C.C projections, chajjias, roofs, facia etc by necessary preparation. Scarpping, cutting, chiseling derusting and cleaning exposed reinforcement, surfaces of damaged, loose R.C.C surfaces with cement concreat (1:1.5:3) using 12.5mm graded crushed stone aggrigates and reinforcement with welded mesh of weight exc 2 kg per sqm but n.exc 3kg/sqm (if reqd) with or without facia and finished with cement and sand motar (1:3) using coarse sand and work in patches area n.exc 5 sqm each and thickness of R.C.C member n.exc 70mm incl necessary form work and applying two coats of finishes to match with the existing surfaces in at any height complete all as specified and as directed by Engr-in-charge. |
| 31 | M&L for pre-cast RCC slab in 1:2:4 type B-1 using 20mm graded stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, complete all as specefied and as directed. |
| 32 | M&L for mild steel bars 6 to 8 mm dia deformed bars cut to length, bent to shape required including cranking, bending and binding with and including MS wire (annealed) not less than 0.9mm dia confirming to Fe-410-0, complete all as specified and as directed. |
| 33 | M&L form work to chajjas and similar items including edges, complete all as specified and as directed. |
| 34 | Dismantling of brick tiles single layer as in roof covering complete all as specified and as directed. |
| 35 | Demolition of mud in roofs any thickness incl plastering& leeping and as directed.. |
| 36 | M&L for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate in roof padding, complete all as specified and as directed. |
| 37 | M&L 15mm thick cement plaster in cement mortar (1:3) on concrete roof surfaces finished even and fair, including cleaning the roof top by water etc all as specified and as directed by Engr in charge with WPC. |
| 38 | Cleaning the surface and made free of dirt, foreign particle, laitance followed by grinding all protrusion to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expiation contraction. Cutting the grooves with suitable cutter machine in V groove filled with repairs mortar/ microconcrate / general purpose grout as recommended proportionally as per recommendation of manufacture. Making of Gollas at all the corners with polymer modified mortar (1:4) cement sand with 3.5% acylic of cement weight. |
| 39 | Supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold appliId of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm. Application should be done with Graco sprayer by a company authorised applicator ” |
| 40 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each all as directed. |
| 41 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area exc 1.5 Sqm but n-exc 4 sqm each complete all as direcrted. |
| 42 | S&F framed work as in doors/window grill or gates of approved pattern & design of angle or other section conforming Fe 290 (Gde-E- 165) quality 'B' with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering of doors, etc. to be prepared for hanging or sliding with and including either hooking and hinges or steel hanging door fittings, cooler stand etc (excluding of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, complete all as specefied and and as directed. |
| 43 | S&F factory made flush shutters, 35mm thick, solid core construction with block board core & ply wood face panels, commercial type on both side incl 40X 6mm thick 2nd class HW lipping on edge, complete all as spd & directed. |
| 44 | S&F 35 mm thick IInd class hard wood glazed or skelton shutter factory made open rebated prepared to receive glass, gauge etc.without sash bars edges of framing plain fitted with cut & mitred beads for securing glass etc size of member all as per clause 8.23 (a) of SSR part-I |
| 45 | S&F steel window/ventilator (combination) with glazed shutter as well as gauged shutter with side hung/ top hung shutters including box type hinges, steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame including guard bars, hold fast, tower bolts and handles & flat iron etc and necessary cooler arrangement in window and fixed with PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate), complete as per Drg No. CEJZ/WD-1655/22 & CEJZ/TD-1019/08 sheet 1/3 to 3/3.Note : The above rate for glazed and gauged shutter window/ventilator and measured one time clear opening for payment of window |
| 46 | S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 47 | S&F 5mm thick sheet glass, ordinary quality and glazing with oil putty in each panes complete all as specified |
| 48 | S&F 5mm thick Figured glass,pin headed type and glazing with oil putty in squares not exc 0.50 sqm in each pane |
| 49 | S & F in repair factory made built-in steel cup board with pressed steel frame and pressed steel shutter 1.00mm thick fixed to masonry wall by hold fasts, made out of 25x3mm flat iron including MS hanging rod of 20mm dia with brackets fixed on inner side of cupboard, provn of MS peg set 3 pegs fixed on inner side of shutter and 1.00mm thick black sheet 3 Nos shelves as shown in Drg including spray painting with two coats of synthetic enamel paint over one coat of red oxide primer all around on steel surfaces of frame and shutter and fixing in PCC (1:2:4) all as directed and shown on Drg No CEJZ / TD-1104/08 Sheet 1/2 to 2/2, complete all as specified and as directed. |
| 50 | Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour sheet reinforced with MS squre tube supplied and fixing as per specification and drawing . |
| 51 | S&F 30 mm factory made solid panel PVC door shutter consisting of frame made out of MS tube for top and bottom rail,MS frame shall be covered with heat moulded plain colour PVC “C” channel having stip of 20 mm width stuck inside with solvent cement rail on either side and as gap inset for top rail and bottom rail, welded/sealed to the stiles and railes with suitable PVC sheet beading and joined together with solvent cement S&F in the frame and site as specification all as specified. |
| 52 | S&F of extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 , complete all as specified and as directed. |
| 53 | S&F aluminium anodised barrel tower bolts of extruded section 200mm long, complete all as specified and as directed. |
| 54 | S&F Extruded aluminium alloy handles, fabricated type,anodised 125 mm in size, complete all as specified and as directed. |
| 55 | S&F 300mm long mild steel sliding door bolts stove enameled black,with bright bolt not less than 12 mm dia with and including minimum of 6 bolts and nuts,four on bolt plate and two on staple plate complete all as specified and as directed. |
| 56 | S&F 125 mm size butt hinges medium weight cold rolled mild steel, complete all as specified and as directed. |
| 57 | S&F 200 mm long mild steel tower bolt stove enameled black with bright bolt, complete all as specified and as directed. |
| 58 | S&F 125 mm mild steel pressed handles oval type ,stove enameled black, complete all as specified and as directed. |
| 59 | S&F mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate welded to steel frame/ screwed to wooden frame complete all as specified and as directed. |
| 60 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor overall length of cover plate 75mm complete all as specified and as directed. |
| 61 | S&F in repairs 20mm dia curtain rails mild steel chromium plated with fixing brackets fixed, complete all as specified and as directed. |
| 62 | M&L for preparation of new wood surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed. |
| 63 | M&L for preparation of new steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome, complete all as specified and as directed. |
| 64 | M&L for preparation of old painted surfaces of steel of any description not other wise described over 10cm width or girth and applying one coats of synthetic enamel paint all as specified |
| 65 | Taking down old steel tubing & connection including cleaning for refixing for 15mm bore pipe complete all as specified and as directed. |
| 66 | Ditto as per Srl item No 62 above but 20 mm bore complete. |
| 67 | S&F 15mm bore dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings with all fittings and fixed complete to walls, ceiling or laid in floor complete all as specifiedgalvanized iron tube s medium grade with all fitting and fixed complete to walls, ceiling or laid in floor complete all as specified |
| 68 | Ditto as per srl item No 64 above but for 20mm bore tube |
| 69 | S & F in repairs 15 mm bore Fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule including taking down the existing fitting. |
| 70 | S&F in repair single lever basin mixer with popup waste, suitable for fixing to 15mm bore (dia) GI Pipe, complete as all specified and as directed. |
| 71 | S&F in repairs angle stop valves 15mm , cast copper alloy , fancy type chromium palted screwed down , high pressure , with crutch or butterfly handle , screwed both ends for iron pipe or for unions and fixed. |
| 72 | S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed. |
| 73 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white including plastic water closet sheet cover white, closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device and including mild steel chromium plated jet fixed to water closet with 15mm dia and 1.2m to 1.5m long flexible pipe complete complete all as specified and as directed. |
| 74 | S&F in repair Vitreous China ware wash basin, white, flat back, size 630x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets and cutting for and pinning in ends of brackets or erecting stand with full pedestal, complete all as specified and as directed. |
| 75 | S&F in repair PVC connection 450 mm long, 15mm size with PTMT nuts complete all as specified and as directed. |
| 76 | S & F in repair flxible PVC waste pipe of approved quality 32mm bore, 75 cm long with one end socketed fixed to waste coupling, complete all as specified and as directed |
| 77 | S&F in repairs 10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe complete all as spfd and as directed. |
| 78 | S&F in repair CP grating 125mm dia fixed in repair all as specified and as directed. |
| 79 | S&F in repair 600mm x 450mm looking mirror of selected quality 4 mm thick glass mounted on 6 mm thick commercial plywood & PVC frame moulding all around and fixed to wooden plug with chormimum plated brass screws and cup washers including fixing arrangement as per approved by Engineer -in- Charge. |
| 80 | S&F in repair, CP soap dish holder and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 81 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed. |
| 82 | S&F in repair, corner shelf 300mm (with brass brackets) and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 83 | M&L for chromium plated peg set of 5 (PTMT), fixed with screws and plugging to rear side of door shutter in bath, complete all as specified and as directed. |
| 84 | S & F in repairs Towel rail 600 mm long and 20 mm dia brass chromium plated D type fixed with screws and wooden or plastic cleats complete all as specified and as directed. |
| 85 | S&F 500 ltr rotational moulded HDPE water storage tank white triple layer antimicrobial(cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing tank of any description complete all as specified. |
| 86 | S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20 mm - 210 gms./ 25mm-455gms/ 40mm - 690 gms) complete all as specified. |
| 87 | S& F in repairs chromium plated shower rose 125 mm size and 15mm dia with or without swivel joints including fixing to pipe and union complete all as specified and as directed |
| 88 | Taking down eaves gutters and rainwater pipes/sewage pipe (any size or pattern), including all fittings,heads,shoes,bends,swan necks etc.including cleaning or refixing or removal to store. |
| 89 | S&F 110 mm bore PVC pipes single socketed in any length with rubber ring joints fixed to walls or laid in floor, complete all as specified and as directed. |
| 90 | S&F 75 mm bore PVC pipes single socketed in any length with rubber ring joints ixed to walls or laid in floor, complete all as specified and as directed. |
| 91 | S&F 110 mm dia PVC (SWR ) bends any radius complete all as specified and as directed. |
| 92 | S&F 75 mm dia PVC (SWR ) bends any radius complete all as specified and as directed. |
| 93 | S&F 110 mm dia PVC (SWR ) junction single, (Single T) equal or unequal with rubber rings ljoits fixed to walls complete all as specified and as directed. |
| 94 | S&F 75mm dia PVC (SWR ) junction single, (Single T) equal or unequal with rubber rings ljoits fixed to walls complete all as specified and as directed. |
| 95 | S&F 75mm dia PVC (SWR ) vent cowl complete all as specified and as directed. |
| 96 | S&F cast iron floor trap with grating including jointing to waste pipe in run lead joint fixed in cement concrete type (1:2:4) type B-1 diameter of outlet 75mm, complete all as specified and as directed. |
| 97 | M&L 75mm thick PCC 1:3:6 Type C-1( using 40mm graded crushed stone aggregate) as in plinth protection/path complete all as specified and as directed. |
| 98 | M&L 75mm thick PCC 1:4:8 Type D-2 (using 40mm graded crushed stone aggregate) as in sub base path etc, complete all as specified and as directed. |
| 99 | M & L for 60 mm thick M-35 grademachine pressed precast concrete interlocking paver block and shape and size conforming to IS -15658-2006 with grey cement and no pigment including dismantling of old paver block complete all as specified and as directed. NOTE: The sample shall be got approved from the GE before build procurement and lots shall be got tested independtly by the GE. |
| 100 | M&L for 25mm sand filling under floors or in foundations including watering and consolidation as specifed and as directed. |
| 101 | M&L for coloured ceramic chequred tiles of size 20cm x 20cm x 25 mm thick with grey cement and pigment, set and jointed in neat cement slurry and pointed in coloured cement to match as in floors incl screed bed 1:6 CM 15mm thick complete all as specified and as directed. |
| 102 | M&L foer PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, edging and other similar work including necessary form work complete all as specifed. |
| 103 | M&L cutting into existing manholes for connecting 100mm bore new drains by cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 and making good pipe and reforming benching as required finishing even and smooth complete all as specified and as directed. |
| 104 | M&L for salt glazed stonewere gully traps, square or round mouthed 150 x 150 mm size type 'P' including cast iron cover grating and setting and jointing to drain pipe in Cement Mortar 1:1 complete all as specified and as directed. |
| 105 | Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light and for taking credit of unserviceable light as per Sch of credit and making good disturbed surface of walls,roof, floors etc. with any type of civil wk involved complete all as specified and as directed. |
| 106 | M&L for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes(min 50 mm deep and 1.6 mm thick sheet) duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engineer-in-Charge.Note :No more than 06 point on one circuit and separate conduit will be used for power circuit and light point circuit as per NBC code 2016. In addition Electric wiring tests to be carried out in accordance with regulation 1103 & 1104 of regulation for the Electrical equipment of buildings (I E E regulations ,Eleventh edition and as per IE rules 2003 in given format in Annexure I. If resistance of wiring will not meet critaria of IEE regulation contractor will be responsible for that and change in wiring will be executed without extra cost. |
| 107 | Ditto all as per srl item No. 103.00 above, but for one Fan point controlled by one switch complete all as specified |
| 108 | Ditto all as per srl item No. 103.00 above, but for one bell point controlled by one bell push complete all as specified. |
| 109 | Ditto all as per srl item No. 103.00 above, but for one light point controlled by two way switches complete all as specified. |
| 110 | Ditto all as per srl item No. 103.00 above, but for one socket outlet 5 Amps on independent board complete all as specified. |
| 111 | Ditto all as per srl item No. 103.00 above, but for one socket outlet 5 Amps on the same board controlled complete all as specified. |
| 112 | Ditto all as per srl item No. 103.00 above, but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and as directed by Engineer-in-Charge. |
| 113 | S&F for in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified. |
| 114 | S&F for in replacement switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified. |
| 115 | S&F for in replacement socket out let 5 Amp, 5 pin flush type complete all as specified. |
| 116 | M&L in replacement Socket outlet multi purpose 2 in 1, 5/6 pin, 5 & 15 Amps, flush type complete all as specified. |
| 117 | S&F for in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, two way complete all as specified. |
| 118 | M&L in replacement Bell push switch, flush type 5 Amps, SP, 240 volts complete all as specified. |
| 119 | M&L in replacement Bell electric AC (Ding Dong) 240 volt SP complete all as specified. |
| 120 | S&F for in repair for batten holder insulated body with matching colour back plate all as specified and as directed |
| 121 | S&F five step fan regulator, electronic type, single phase, including connection complete all as specified. |
| 122 | S&F for in repair for ceiling rose surface type bakelite 65 x 50mm, three terminal complete all as specified. |
| 123 | Supply and fix exhaust fan, steel body AC single Phase. 230 V of size 225/230 mm sweep with, blades, and frame and louvers complete including making good to disturbed surface complete all as specified and as directed. |
| 124 | Cutting holes for exhaust fan of size 225/230 mm dia sweep in brick walls built in cement mortar or cement lime mortar and stone walls built inline mortar for inserting holdfasts and making good dismantled portion in cement mortar 1.3 or cement concrete 1:2:4 Type B-1 as required. |
| 125 | S&F in repair Decorative wall mounting light fitting suitable for 09 watt LED lamp complete with glass shade/ polycarbonate cover including 1 x 09 watt LED lamp complete all as specified and as directed by Engr-in-Charge. |
| 126 | S&F for LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and as directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : greater than 90 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 127 | Fixing only serviceable tube light fittings any type and any description retrieved under item Srl No. 01, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as directed. |
| 128 | S & F LED light fitting 1 x 9/10 W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 129 | S&F for energy efficient LED security light fitting of 35 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and as directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 130 | M&L in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm complete with any type of civil work involved to make good disturbed surfaces all as specified.Note : Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit |
| 131 | S&F for (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and as directed by Engineer-in-charge.Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ. |
| 132 | S&F for (concealed flush to wall) factory made VTPN (Vertical type), 4 Way 415V, as per IEC 61439-3, DB (made out of CRCA sheet not less than 1.2mm thick, with copper bus bar rating of suitable capacity, with two neutral bar, 2 earth bar and cable tie for cable management, suitable for MCCB 4 pole upto 125Amp, as incomer and suitable for mounting MCBs as outgoing, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and as directed by Engineer-in-charge.Note :- MCBs for outgoing shall be measured and paid separately under appropriate item of BOQ.directed. |
| 133 | S&F for in repair MCCBs 125 Amp 4 pole 415 V , adjustable thermal and fixed magnetic settings (0.8 to 1.0) to Ics=100% Icu short circuit setting fixed breaking capacity 25 KA with phase barriers/ separator/spacer/copper spreader link and required nut bolts complete all as specified and as directed. Note- Make of VTPN DB and MCCB should be same. |
| 134 | Supply & Fix MCB SP 6 to 32 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed by Engr-in-charge. |
| 135 | Supply & Fix MCB SPN 40 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed by Engr-in-charge. |
| 136 | M& L for XLPE insulated,in replacement PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4.0core complete laid in trenches passing through pipes/culverts/ under roades/ alon wall all as specified and as directed by Engineer-in-charge. |
| 137 | Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in soft soil, complete all as specified and as directed. |
| 138 | M & L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (Surplus soil if any shall not be removed but left over the trench) |
| 139 | M & L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed. |
| 140 | M & L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified.Note : For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR part-I. |
| 141 | M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and as directed at site. |
| 142 | M&L for boring hole under the road/pavement/hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting 50mm GI pipe suitable working pressure not less than one meter below ground level complete all as specified and as directed by Engineer-in-charge. |
| 143 | Taking down carefully ceiling fan of any sweep, any size/make having any winding from existing position of any height by disconnecting elect connections and transporting/ shifting to GE(E) JRC Elect for inspection in presence of JE incharge in workshop and transporting/ shifting back to qtr/ building/ accn after repair from where dismantled etc complete all as specified and as directed. Note: The parts replaced under repair shall be measured under relevant item of schedule |
| 144 | Hanging only/ fixing only ceiling fan 1200mm/1400mm sweep after repair & maintenance upto any height upto 5 Mtr complete incl making electric connections, testing for full speed complete all as specified and as directed |
| 145 | Taking down and refixing of existing water heater any type capacity all as specified and as directed by Engineer-in-charge |
| 146 | M&L for Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2020 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved.all as specified and as directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.Note:Earth plate weight will be approved by Engr in charge before execution of earth work. |
| 147 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge in all kind of soil. |
| 148 | Ditto all as per item No 144 above, but exc 1.50 m and n exc 3 m. |
| 149 | Ditto all as per item No 144 above, but exc 3 m and n exc 4.50 m. |
| 150 | M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation,mass concrete complete all as specified. |
| 151 | M&L RCC M-25(20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. |
| 152 | M&L RCC M-25(20mm graded aggregate) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses |
| 153 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished smooth. |
| 154 | Formwork to faces of walls,bretaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter finished smooth. |
| 155 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 156 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 157 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 158 | M&L for trail bore in normal available strata (size 300mm and above) upto 50.00m depth complete all as directed by Engr-in-Charge. |
| 159 | Ditto all as per item No 155, above,but depth exc 50.00m and not exc 75.00m depth complete all as directed by Engr-in-Charge. |
| 160 | S&F for PVC pipe 150mm dia first quality including all necessary fittings complete all as directed by Engr-in-Charge. |
| 161 | S&F for perforated/slotted PVC pipe 150mm dia first quality including all necessary fittings complete all as specified. |
| 162 | Material & labour for gravel packing 3mm to 5mm size aggregate including jute as filter media around MS pipe complete all as specified. |
| 163 | M&L for filling of gravel in trenches of size 12.5mm coarse aggregate upto height of 0.50m complete all as specified. |
| 164 | M&L for filling of gravel in trenches of size 3mm to 5mm upto height of 0.50m complete all as specified. |
| 165 | M&L for filling of coarse sand in trenches upto height of 0.50m complete all as specified. |
| 166 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil. |
| 167 | Removing excavated material (soil) exc. 250 m but n exc. 500 m and depositing where directed. |
| 168 | M&L for plug cap 160mm dia and housing clamp with nuts and bolts complete all as specified. |
| 169 | M&L for applying two coats of synthetic enamel paint over zinc primer including preparation of steel surfaces |
| 170 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, drain, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 171 | M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in surface channels and drains. |
| 172 | M&L for Cement concrete type C1 1:3:6 using 20 mm graded stone aggregate in surface channels and drains |
| 173 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement. |
| 174 | M&L for rendering 10 mm thick in CM 1:4 on brick or concrete surface and rendering is to be finished even and smooth (without using extra cement). |
| 175 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in copings, bed plates, watertroughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 176 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 177 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail