| 1 | Dismantling of plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed. |
| 2 | S&F Plain galvanised mild steel sheeting of 0.63 mm thick in ridges ,hips ,valley gutter drip and straight flashing (length and girth as fixed ) with grade of zinc coating 275 complete all as specified and directed. |
| 3 | Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 4 | S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with J hooks two framed work with PVC and steel washers as in roof & wall with grade of zinc coating 275 complete all as specified and directed. |
| 5 | Dismantiling Wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 6 | S & F Roof trusses Fe 410W (grade-E-250)quality A (framed )trussed ,purlins crane gantries rails etc(beam tee angle channel or flat sections) complete all as specified and directed. |
| 7 | Dismantling timber framed in fillets,rails, posts rafters,purlines, etc under 40 sq cm in section complete all as specified and directed. |
| 8 | Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation board/slabs/ blanket any thickness including cover filllets complete all as specified and directed. |
| 9 | M&L plain fillet second class Hardwood plain filllets, rectangular in section, clean swan, secured with nails exc 13 and n.exc 25 Sqcm complete all as specified and directed. |
| 10 | M&L 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in ceiling complete all as specified and directed. |
| 11 | M&L 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in wall paneling complete all as specified and directed. |
| 12 | M & L for 12 mm width teak wood lipping 6 mm thick for Patical board/block board complete fix with nail complete all as specified and directed. |
| 13 | M&L Preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 14 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above ground level) complete all as specified and directed. |
| 15 | M&L for 100 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) complete all as specified and directed. |
| 16 | M&L for providing cement concrete type C-1, 1:3:6 (using 20mm graded stone aggregate),75 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement complete all as specified and directed. |
| 17 | M&L for Self Levelling Epoxy Flooring 5mm System:-(a) Cleaning, grinding, washing and priming with applying epoxy primer one coat.(b) 3mm thick screed, epoxy resin,hardener,epoxy primer self levelling.(c) 2mm thick top epoxy coat with epoxy gel & pigment self levelling with universal colour shade complete all as specified and directed. |
| 18 | Taking down carefully damaged copper/aluminum point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, cassing & capping, pendants, sockets, light fitting etc and making good disturbed surfaces of wall/roof complete all as specified and directed. |
| 19 | Taking down of MCB DB/TPN of any size including MCB SP and SPN and making good of wall complete all as specified and directed. |
| 20 | Material and labour for point wiring for one light point controlled by one 10 A switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core,FRLSH PVC insulated & unsheathed cable, 1100 volts grade drawn in PVC casing and caping and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly incl factory made GI/PVC sheet sunken box with PVC modular cover plate ,chrome collar , base frame and making good disturbed surface of walls, roof etc. complete all as specified and directed. |
| 21 | All as per Serial item No 20 above but point wiring for 3/ 5 pin switch socket outlet on same board. |
| 22 | Material and labour for point wiring for one light point controlled by one 15 Amps switch with using 2.5 Sqmm (nominal area) stranded copper conductor, single core,FRLSH PVC insulated & unsheathed cable, 1100 volts grade drawn through rawn in PVC casing and caping and using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly with incl factory GI/PVC sheet sunken box with PVC modular cover plate ,chrome collar , base frame and making good disturbed surface of walls, roof etc. complete all as specified and directed. |
| 23 | All as per Serial item No 22 above but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 4 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous 4 sq.mm earth wire on independent board for one socket outlet 3 pin 15 amps complete all as specified and directed. |
| 24 | S&F Modular Switch 1 way 10A, 1 module, 240 Volts complete all as specified and directed. |
| 25 | S&F Modular Socket, 10Amp - 2/3 pin combined 2 module with shutter complete all as specified and directed. |
| 26 | S&F Socket outlet 10A/16A - 3 pin combined 2 module complete all as specified and directed. |
| 27 | S&F Modular switch 1 way 16A,, 240 Volts complete all as specified and directed. |
| 28 | S&F Ceiling rose surface backelite ISI marked with 3 terminal including connecting and testing complete all as specified and directed. |
| 29 | M & L in replacement of sub main wiring using two single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size 4 Sq.mm of 1100 Volts voltage rating drawn through and including PVC casing caping of size not less than 25mm with standard accessories, along-with one run of FRLSH PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sq.mm as earth continuity conductor complete all as specified and directed.Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit. |
| 30 | M & L in replacement of sub main wiring using two single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sq.mm of 1100 Volts voltage rating drawn through and including PVC casing caping of size not less than 25mm with standard accessories, along-with one run of FRLSH PVC (green colour) insulated, unsheathed, stranded copper conductor of size 2.5 Sq.mm as earth continuity conductor complete all as specified and directed.Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit. |
| 31 | Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 8 way with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one ccomplete all as specified and directed. |
| 32 | S&F MCB DB sheet enclosure,Double door type, Triple pole and neutral 4 way 240V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. |
| 33 | S&F 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP and current carrying capacity 40 to 50 AMP iin the DB complete all as specified and directed. |
| 34 | S&F in repair rating 240V, SPN 32 Amps 10KA 'C' curve miniature circuit breaker (MCB) of poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 35 | S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 20 AMP SP , in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 36 | Aviation obstruction light 230V AC, Red, LED based, Day/Night Photocell Sensor, Flashing 20-60 FPM.Input Voltage: 48V DC/24V DC/230v AC ,IP Rating: IP 65 As per Standard IS/IEC 60529: 2001 Photocell auto On/Off (Internal fitted),Polycarbonate glass for 360 Degree Illumination complete all as specified and directed. |
| 37 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed. |
| 38 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including suitable size street light bracket, making necessary connection complete all as specified and directed. |
| 39 | S&F LED flood light 210 watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 40 | S&F flame proof, LED High Bay light fitting 1x120 Watt CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 41 | S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 42 | S&F in replacement 1100 volts grade heavy duty armoured cable XLPE insulated aluminium conductor 16 sq. mm, 4 core overall PVC sheathed cable complete all as specified and directed. |
| 43 | S&F single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and directed. |
| 44 | S&F Aluminium Strip 25mm x 3.15 mm complete with Porcelain shadles and fixing screw for fitting of strip for roof conductors and down conductors above ground complete all as specified and directed. |
| 45 | S&F Material and labour for fixing of test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed. |
| 46 | S&F lay of GI pipe light grade for fixing of air terminal rod over the top edge of GI pipe of size 20 mm dia fixed on the top of roof complete all as specified and directed. |
| 47 | M&L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with using 32 x 6 mm Copper strip and copper earth plate of size 900 x 600 x 5 mm ,as earth electrode Earthing all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion complete all as specified and directed. |
| 48 | M&L for making foundation for fixing of air terminal light grade pipe with cement concrete in foundation and mass filling of size 20cmx20cmx15cm on the top of roof complete type B0 (1:2:4) with 12.5 mm graded stone complete all as specified and directed. |
| 49 | Deduct Schedule of Credit of as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item Please Enable Macros to View BoQ information |