| 1 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 2 | Cement Concrete 1:5:10 with stone ballast using mechanical mixer volumetric type. |
| 3 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 4 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 5 | Shelves |
| 6 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 7 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 8 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 9 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 10 | 20 mm thick cement plaster in damp proof course 1:3 with two coats of bitumen 1.65 Kg. per Sqm. hot laid and sanded. Vertical |
| 11 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
| 12 | Ground Floor |
| 13 | First Floor |
| 14 | Extra rate for First Floor |
| 15 | First class burnt brick work laid in cement sand mortor 1:4 in first storey upto 4 metres above plinth level. |
| 16 | Extra for burnt brick work in square or rectangular pillars in building. |
| 17 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. |
| 18 | Dressed or moulded one brick cornice laid in cement sand mortar 1:4 including 12mm thick cement plaster 1:4 or pointing as required. |
| 19 | Extra rate for Smooth Surface of Ceiling. |
| 20 | 12.5mm thick cement plaster 1:5. Inner Plaster |
| 21 | 20 mm thick cement plaster 1:5 in two coats work. Inner Plaster |
| 22 | 12.5 mm thick cement plaster 1:4. |
| 23 | 20mm thick cement plaster 1:4 in two coat work.Outer Plaster |
| 24 | Forming groove of uniform size from 12xl2mm and upto 25xl5mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. |
| 25 | Bearing plaster of 10 mm thick cement plaster 1:3 cement sand finished with a floating coat of neat cement and thick coat of lime wash/POP on top of walls when dry for bearing of RCC slabs and beams. |
| 26 | Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (ring fitted type-A) as per IS:13592 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) |
| 27 | Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 28 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 29 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 30 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
| 31 | Providing and fixing in position gratings 150mm x 150mm on top Khura PVC grating |
| 32 | Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement |
| 33 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 34 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead . |
| 35 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres. |
| 36 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling |
| 37 | Kota stone tile flooring 20mm to 30 mm thick over 12.5mm thick base of cement mortar 1:3 (1 cement, 3 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing. |
| 38 | Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing |
| 39 | Extra labour for projected nosing of stair case of any shape and design over item Nos. 14.24 and 14.40 if 33 % white cement in 6mm thick top layer is used. |
| 40 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. |
| 41 | Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-incharge. |
| 42 | Precast chequered tiles of 20mm thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps on landings. |
| 43 | Conglomerate floor 50mm thick cement concrete topping 1:2:4. |
| 44 | Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete.Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg/rmt |
| 45 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, Cillral mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items) |
| 46 | Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect |
| 47 | Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects. |
| 48 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 49 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick above 0.40 sqm area. |
| 50 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 51 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm Thick |
| 52 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 53 | Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 10mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for stiles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the stiles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of Engineer-in-charge. |
| 54 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm |
| 55 | Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 56 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete.I.S.I Designation No. II (size of door 701mm to 850mm) |
| 57 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) |
| 58 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 59 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 5 mm thickness. |
| 60 | Extra for providing Polyster Powder Coating to aluminium extruded sections (minimum thickness of Powder coating 50 micron). |
| 61 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish |
| 62 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 63 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two coats) |
| 64 | Applying priming coat with metal primer on new steel or iron work including preparation of surface.With ordinary quality Paint |
| 65 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 66 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 67 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 68 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 69 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm |
| 70 | Construction of Plinth protection complete as per drawing.Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 71 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer volumetric type. |
| 72 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 73 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads. |
| 74 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling |
| 75 | Conglomerate floor 40mm thick cement concrete topping 1:2:4. |
| 76 | 12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. |
| 77 | outer infrastructure such as Construction of Parking & Approach RoadConstruction of Embankment with Good Quality Earth obtained from Borrowpits Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications |
| 78 | Compaction of earth work & Preparation o sub-grade including loosening, leveling of earth 225mm thick top layer,rough dressingof soil,final dressing of earth to give level,camber,watering, rolling with road roller,compacting the bed to achieve minimum dry density as given in Table 300-2 as per technical clause 305 of MORT&H specifications.(In case of link roads earth work to be done by villagers.) |
| 79 | Cement Concrete 1:4:8 with stone ballast of size unsing machanical mixer |
| 80 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 81 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete |
| 82 | Internal Furnishing Provision for Elevation Treatment with ACP Sheet ,Providing Logo Seva Kendra & other Signages |
| 83 | P/F Service Counter including side storage 4 nos with sal wood frame as per as per architectural drawings and entire satisfaction of Engineer-in- charge. |
| 84 | P/F Help Desk 6.25 wide as per architectural drawings and entire satisfaction of Engineer-in- charge. |
| 85 | P/F Storage cabinet 16 feet long above 6.75 . as per architectural drawings and entire satisfaction of Engineer-in- charge. |
| 86 | P/F Partition panel( 6'-0\\" x 7'-0\\") as per architectural drawings and entire satisfaction of Engineer-in- charge. |
| 87 | P/F Display Board as per architectural drawings and entire satisfaction of Engineer-in- charge. |
| 88 | P/F Form Filling Counter 01 nos. as per architectural drawings and entire satisfaction of Engineer-in- charge. |
| 89 | P/F Sun Control Film Garware on all windows and front glass door with necessary solution complete as per architectural drawings and entire satisfaction of Engineer-in- charge. |
| 90 | Three Seater Waiting Benches made of Stainless Steel (4 Nos) |
| 91 | Computer Operator Revolving Chairs with Rexion covering (5 Nos) |
| 92 | Public Health WorksCement concrete 1:4:8 with stone ballast 20mm gauge with stone ballast 20mm gauge |
| 93 | Cement concrete 1:2:4 With stone ballast or shinglemixing by manual means |
| 94 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping using mechanical mixer for mixing of material. |
| 95 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 96 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 97 | Providing, laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.), painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. 15 mm i/d |
| 98 | 20 mm i/d |
| 99 | Providing, fixing and jointing G.I Union Couplings (of approved make with the approval of EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.15 mm i/d G.I. Union |
| 100 | 20 mm i/d G.I. Union |
| 101 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.20mm i/d Gun Metal peet valve |
| 102 | Cutting holes up to 23 cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required.Through wall 22.86 cm thick |
| 103 | Providing and installing in position premium range water pressure boosting pump (To the approval of Engineer-in-charge) including all pump accessaries but excluding cost of G.I pipe & specials complete in all respects. Pressure pump of 0.7 HP with 4700 LPH, 20.3meter head with SS pump & 24 litre capacity TankModel : CM 5- |
| 104 | Excavation of trenches in a Streets, Lanes or in Open Area for Storm Sewers and Manholes to Full Depths as Shown in Drawings,excluding Shoring, Timbering of Poling Board Frame System Type, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines.night signals, profiles, Pegs, Sight rails, boning rods, crossing over trenches for access to the houses, watching, fencing etc., fixing and maintenance of caution boards, refilling trenches, watering of refill in 15 cm layers, ramming and restoration of surface to original conditions and removal of Surplus Spoil from the Site of Works, for all Works other than connections to Ventilating Shafts upto a Lead of 15 mtrFor depth not exceeding 2 m. below Ground level |
| 105 | Providing, lowering, cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS: 651-2007 class Sp-1 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc., cutting of concrete beds and joints holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching, haunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun Jute yarn as per IS:1887, finishing and trowelling of each joint at an angle of 45 degree with the longitudinal axes of pipe, watering, keeping the joint covered and wetted till the same are cured, testing the sewerage line for leakage and making all leakages and defects good as laid in the contract specification, chipping and finishing the cut surface to uniform finish to the entire satisfaction of engineer-in-charge Including all cartage etc complete in all respects. 200mm i/d pipe |
| 106 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming toI.S.I complete as per standard design. 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 107 | Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda Sewer connections upto 300 mm id |
| 108 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 109 | Extra for providing and fixing C.P. Brass short flush bend 32mm instead of PVC short bend. |
| 110 | Extra for providing and fixing 10 litres capacity Chinaware low level flushing cistern with PVC internal fitting, instead of 10 litres capacity PVC flushing cistern. |
| 111 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. With C.P. Brass nut |
| 112 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 113 | Providing and fixing Stainless steel health faucet complete in all respect. |
| 114 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 550 mm x 400 mm x 815 mm |
| 115 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 116 | Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge) |
| 117 | Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge) |
| 118 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.Vitreous chinaware standard white pedestal for wash hand basin. |
| 119 | Providing and fixing in position C.P. brass soap dish of approved make fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 120 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 1500mmx600mm or any other size |
| 121 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect. |
| 122 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 123 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete inall respect. |
| 124 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.CP Brass Bib Cock |
| 125 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect.C.P.brass 15mm Angle valve without flange |
| 126 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x 450 mm with Brass nut |
| 127 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B110mm o/d SWR UPVC pipe lines laid complete |
| 128 | 90mm o/d SWR UPVC pipe lines laid complete |
| 129 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge )110mm o/d |
| 130 | 90mm i/d |
| 131 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm o/d pipesDoor Cap |
| 132 | Door Elbow 90 Degree (All side socketed) |
| 133 | Elbow 90 Degree (All side socketed) |
| 134 | Coupler |
| 135 | P Trap/Floor Trap 110mm x 75mm |
| 136 | For 90mm o/d pipesDoor Elbow 90 Degree (All side socketed) |
| 137 | Elbow 90 Degree (All side socketed) |
| 138 | Coupler |
| 139 | Providing & fixing in position C.P. copper tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. copper tube connection of size 15 mm x 600 mm with C.P. Brass nut |
| 140 | Brass Ball Cock with rod and PlasticBall Providing and fixing in position automatic brass Ball Cock in tanks20mm i/d |
| 141 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks |
| 142 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.G.I. tank nipple 25mm i/d |
| 143 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 144 | Providing and fixing in position water meter including labour and material complete in all respects |
| 145 | Water Connection charges complete in all respects |
| 146 | Construction of Platform for placing PVC Water Storage Tank with brick work and plaster etc. complete in all respects. |
| 147 | Air ConditionersSupply and Installation of Toshiba/Carrier/Daikin make 2-Star rating with EER>3.5 Fixed Speed Model (Cooling only without installation kit i.e. Copper Pipe) or any other equivalent make Split Type Air Conditioner of 1.5 Ton capacity suitable for 230 Volts single phase supply with nature friendly refrigerant R32 or equivelant capable of performing the following functions :- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering including cost of installation complete in all respects. |
| 148 | Providing and installing Automatic Voltage Stabilizer copper winding and having suitable range for input and output of 4 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect make V-Guard, Liv Guard, Luminous and any other equivalent make. |
| 149 | Providing and fixing refrigerant copper pipe (Type B) for Split type Air Conditioner including insulation complete in all respects of approved make. |
| 150 | Providing and fixing 20 mm i/d PVC drain pipe with insulation to prevent seepage in walls with specials for Split type Air Conditioner complete in all respects of approved make. |
| 151 | Providing and fixing PVC 70/76, 3 Core Electrical Wire for Split type Air Conditioner complete in all respects |
| 152 | Providing and fixing angle iron stands for placing outdoor units. |
| 153 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Full Steel Body 150/150 ltr without Stablizer |
| 154 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 155 | Providing and Fixing plug top of 15 Amp. complete in all respects |
| 156 | Cutting holes up to 23 cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required.Through wall 22.86 cm thick |
| 157 | Electrical WorksRECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring fan point (With fan box) |
| 158 | Wiring light point |
| 159 | Wiring 6Amp. wall socket point |
| 160 | Wiring 6Amp. Plug control comprising wall socket point |
| 161 | Wiring 16/20Amp. power plug control point |
| 162 | PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (Un-sheathed) |
| 163 | Overall size 2.5sq.mm (Un-sheathed) |
| 164 | Overall size 4sq.mm (Un-sheathed) |
| 165 | Overall size 6sq.mm (Un-sheathed) |
| 166 | Overall size 10sq.mm (Un-sheathed) |
| 167 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 168 | MCB Double Pole 50, 63amp. (10kA, Curve-C) |
| 169 | COPPER EARTHING:8 SWG COPPER EARTHING :Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 170 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 171 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 172 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 173 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 16sq.mm (2Core) Un-armoured (Loose) |
| 174 | MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 175 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 176 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-Bakelite Batten Holder (Large size) |
| 177 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 178 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-Modular RJ-45 Modem Jack for Computer (One Module) |
| 179 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES:Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:-ICDP Changeover Switch 63amp., 415volts |
| 180 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-CAT 6 LAN cable |
| 181 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Horizontal Double Door Distribution Board 4 way each |
| 182 | Supply and Erection of 3 Star Rating Ceiling fan Suitable size 48\\" (1200mm) Full Aluminium Body, 3 Nos. of Blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delevery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minute and 5 Nos, of speed. The approximate weight of the product should be 4kg and 180gms (without packing) or higher. The product should have a manufacturer's guarantee/ warranty of minimum 2 years. The product should be complete in all respects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fans having connection with PVC insulated PVC sheathed tow single core copper conductor (FR) cable 0.75 SQ MM. Complete in all respects as desired by the Engineer in charge of work at site. The Product should be BEE & BIS Certified. |
| 183 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Beside this the lighting manufacturer should have inhouse NABL accurdited Lab. |
| 184 | Supply & erection of Exhaust fan of suitable size 12'' 300MM Sweep of including connection & testing complete in all respect as desired by the Engineer in-charge of work at site. |
| 185 | SITC of CAT 6, 24 Port Fully loaded Patch Panel, Rack Mountable for cable termination |
| 186 | SITC of CAT 6 ONE Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps. |
| 187 | SITC of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps |
| 188 | SUPPLY & ERECTION of 2000GB Audio Video HDD 3.5 Inches Connector SATA, Interface SATA, Operating Temperature 0°C to 65°C, Transfer Rate minimum 160MB/s, Recording Technology – CMR, Certifications BSMI, ICES-003/NMB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL for NVR recording and playback complete in all respect as desired by the engineer in charge at site |
| 189 | Supply & erection of 03 meter long superior quality 4K HDMI Cable having speed upto 10gbps support all types of HDMI Devices complete in all respect as desired by the engineer in charge at site. |
| 190 | Supply & erection of RJ45 Male Connector complete in all respect |
| 191 | Supply & erection of 9Watt LED Bulb complete in all respect & as desired by engineer in charge of work at site |
| 192 | Supply & erection of 6KVA Online UPS with 18 No. Batteries 12V/26Ah Pure Sine wave with following features OVCD Wide input range Programmable output range 220V/230V/240V 12V x 26Ah x 18 No. SMF batteries with rack in-built Output Power Factor 0.9 0ms Transfer time from Inverter Mode to Battery Mode Charger Current 3.5 Amp Cooling Fan True Online Inbuilt Over-voltage Cut-off Device Inbuilt Over Temperature Protection Surge Protection Better Overload Protection upto 102% Constant Higher Efficiency up-to 90% in ECO Mode 1 year onsite warranty on UPS30+ minutes Back up time on load complete in all respect & as desired by engineer in charge of work at site. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail