| 1 | Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed. |
| 2 | S&F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 4 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed |
| 5 | Dismantling timber in scantling 40 sqcm and over in section, framed work complete all as specified and directed. |
| 6 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified. |
| 7 | Dismantling framed trusses , span not exc 10m trusses, include unbolting, dismantling framed work into two or more portable parts and marking members for re-erection, complete all as specified. |
| 8 | Demolition of brick work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 9 | Taking down and removing chowkats with shutters (without taking off shutters from chowkat) not exceeding 1.50 Sqm each complete all as specified and directed. |
| 10 | Taking down and removing chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed. |
| 11 | Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed |
| 12 | M&L RCC Type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 13 | Use & waste of formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide for fair finished surfaces of flat concrete, complete all as specified & directed. |
| 14 | Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 15 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 16 | M&L Brickwork with modular fly ash bricks, straight or curved on plan exc 6m mean radius, built in built in cement mortar 1:6 all as specified & directed |
| 17 | M&L Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-B, complete all as specified and as directed. |
| 18 | M&L Preparation of new steel surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 19 | M&L 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. . |
| 20 | M&L 25mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in floor finish, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L Vitrified ceramic tiles (Dark shade) 10mm thick (square/rectangular) polished, area of each tile exceeding 0.42Sqm but not exceeding 1 sqm as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.Note : Grouting of joints shall be done using 3mm thick spacer and epoxy grout mix of 0.70 Kg of organic coated filler of desired shade (1.10 Kg of hardner and 0.20 Kg of resin per kg) including filling/grouting and finishing. |
| 22 | M&L Vitrified ceramic tiles (Dark shade) 10mm thick (square/rectangular) polished, aarea of each tile exceeding 0.42Sqm but not exceeding 1 sqm , as in ski+C27rting/vertical surfaces etc , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick screed bed or bedding layer in cement mortar 1:3 complete all as specified and directed. Note : Grouting of joints shall be done using 3mm thick spacer and epoxy grout mix of 0.70 Kg of organic coated filler of desired shade (1.10 Kg of hardner and 0.20 Kg of resin per kg) including filling/grouting and finishing. |
| 23 | Hi Steel Clip in false Ceiling System with Steel Tile 595 mm X 595 mm manufactured out of 0.50 mm thick polyester coil-coated Galvanized Steel having 180 gms zinc coating Coil-coated Steel tile shall have a 20-micron polyester-coated finish on front side and a backcoat of 5-micron alkyd primer. Two sides of each tile shall have raised, piped and stopped to ensure positive engagemant into the spring clip in profile allowing for demlition of individual tiles The rgid susoension system consists two rows of 0.5mm galvanised steel clip in profile od size 38mm installed at 600mm centre to centre spacing to support the tiles Wall suspesion Wall Suspension angles /Hangersof size 24 mm X 24 mm X 0.4 mm thick are fixed to the roof by expansion fasteners. Wall suspension angles to be made out coil coated Steel matching the color of the tile. They will be jointed to the clip-in-profilr system by hold on clamps. The Tiles/Planks shall be held in place by pressure clips as per manufacturer's instructions for spacing in the flexible system the hanger and butterfly clip shall replace the suspension angle, complete all as specified. |
| 24 | Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC M-15, type B-0 (04 No's for each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces) and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf. (iii) MS tower bolt 150mm long - 2 No per leaf (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) 10mm square bar grill as per drawing (ix) Fabrication & fixing arrangement as per drg No. CEPZ/ TD-26/13 (Sh 1/5 to 5/5 ). Make : As per Appendix 'C'. Note:-(i) Above referred drawing has not been made part of tender. The same can be seen in the office of AGE (I) during working hours on any working day. |
| 25 | S&F Stainless steel wire cloth, 0.40 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified. |
| 26 | S&F Sheet glass, 3mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed. |
| 27 | S&F Pressed steel frame using 1.25 mm thick PBI sheet (size of frame 125 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock/ strike plate etc and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkats complete all as specified. |
| 28 | S&F 35mm thick 2nd class hardwood Plain framed, panelled shutter (Factory Made) (two panel) with lock rail and panel of 9 mm B.W.P. commercial plywood . The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated and fitted to chowkats complete all as specified and directed. |
| 29 | S&F 35 mm thick 2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (divided into squares) and fitted to chowkats, edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members of door shutters as specified in SSR- 2009 Part-I Section 8.24(a) supplied and fitted to chowkats with edges of sash bars and framing moulded complete all as specified and directed. |
| 30 | M&L Preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 31 | S&F Aluminium anodized barrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed. |
| 32 | S&F Aluminium handles, cast type, anodised of size 150 mm complete all as specified and directed. |
| 33 | S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 34 | S&F 300mm, Mild Steel, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 35 | M&L 20mm thick, Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 36 | M&L Cutting, rubbing/grinding & mirror finish ,rounding of edges of marble/ kota stone/ granite stone complete all as specified and directed. |
| 37 | M&L Mild steel sheet eaves gutters 1 mm thick, 150mm dia , galvanised class 3, half round with rounded edges, fixed in repair, complete all as specified and as directed. |
| 38 | M&L Angles (internal or external) or nozzle pieces (Out lets),1 mm thick, 150mm dia , for eaves gutter, complete all as specified and as directed |
| 39 | M & L for 150 mm dia 1 mm thick Mild steel sheet eaves gutter drop ends (for spigot or socket ends) or nozzles |
| 40 | M& L 150 mm dia Cast iron rainwater socketed pipes with cement joints, without ears |
| 41 | M&L Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 42 | M&L Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 43 | Supply only intergal water proofing compound, complte all as specified. |
| 44 | M&L Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting 2 mm thick wall putty complete all as specified. |
| 45 | M&L Preperation of new plastered surfaces of walls and applying applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties Exterior over one coat of water proof primer on walls and chajjas with 10% dilution of water including smoothing the surface with wall putty @ 2kg/ Sqm of average thickness 2mm with silicon additives and sanding these surface for removal of loose particles , complete all as specified. |
| 46 | Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required. |
| 47 | M&L Point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable 1100 volts including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into concealed rigid non-metallic PVC conduit Med Grade ISI marked not less than 20mm wide of 1.8mm wall thickness ISI marked including modular GI sunken flush box (Pressed steel powder coated Modular GI sunken flush boxes and cover plates of any way i.e. 1 to 8 way as per site requirement suitable for modular switch/socket) for mounting switches, sockets, fan regulators etc & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and as directed for the following:- (a) Wiring shall be done by using proper colour coding(b) Earth wire shall be of green colour(c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed. |
| 48 | All as per serial item No '47' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed. |
| 49 | All as per serial item No '47' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed. |
| 50 | All as per item No 47 above but for power point 3 pin switch socket 16 Amp with PVC insulated copper conductor cable multistrand unsheathed 4 Sqmm (two run with colour code RYB) on independent board including one run of 4 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in concealed PVC conduit of appropriate size and best quality ISI marked, including all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-ll under heading \\"Point wiring\\" fixed on wall including sunk cast iron or PVC terminal boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed |
| 51 | S&F Modular switch 1 way 6A, 1 module, all as specified. |
| 52 | S&F Modular Socket, 6A - 2/3 pin combined 2 module, all as specified and directed. |
| 53 | S&F Modular switch 1 way 16A, 1 module, all as specified. |
| 54 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, all as specified. |
| 55 | S&F Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified. |
| 56 | S & F in replacement of surface/wall mounted batten LED luminair 20 watt 6000 K Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate having efficiency 120 lumens power factor more than 0.90,IP 20 including making connections with flxible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 57 | S&F Sheet metal enclousers, TPN Distribution board 4 way 415 V, double door complete with copper bus bar and neutral link earthing fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 58 | S&F MCB Triple pole and nuetral 63Amps, 240 volts, 50 Hz complete all as specified and directed. |
| 59 | S&F Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified. |
| 60 | MCB single pole and nuetral 6 to 40 Amps, 240 volts complete all as specified and directed. |
| 61 | MCB single pole 6 to 32 Amps, 240 volts complete all as specified and directed. |
| 62 | M&L sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS-H, cable of 2 run 6 Sq mm for phase and neutral and one run of 6 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS-H, cable drawn through non metallic rigid PVC conduit not less than 20mm dia ISI marked including all conduit and fixing accessories complete. Two runs of cable for phase/neutral, one run of cable for earth and one run PVC conduit will be measured and paid as one unit length complete all as specified and directed. |
| 63 | S&F 35Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable size to fitting including bracket made up of 32mm dia GI pipe light grade 1.5 metre long and bent to shape required, complete all as specifiedMake: Havells cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Appx |
| 64 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
| 65 | Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 23 of tender doucments. Please Enable Macros to View BoQ information |