| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group B |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 4 | 2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire |
| 5 | 2 x 4 sqmm + 1 x 4 sqmm earth wire |
| 6 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 7 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 10 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 11 | supplying and fixing following way double door single pole and natural MCB distribution board 240 volt on surface/recess complete with tinned copper busbarm neutral busbar, earth bar, din bar, detachable gland plate, interconnections , phosphatized and powder painted including earthing etc as required (But without MCB/RCCB/Isolator) |
| 12 | 8 way, Double door |
| 13 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of connections, testing and commissioning etc. as required. |
| 14 | Single Pole |
| 15 | Double pole |
| 16 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 17 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation andre-filling as required |
| 18 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 19 | Supplying and laying of 32 mm dia, PVC pipe for protection of UG cable etc as required. |
| 20 | Supplying & fixing of 20/22 watt 4 feet energy effiecient LED tube light(batten) directly on ceiling suitable for single phase AC 230 V complete with accessories connection etc as required. |
| 21 | Supplying, Installation, testing and commissioning of ceiling fan 1200mm sweep ISI mark single phase 230v 50HZ and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 22 | Supplying and Laying of one number XLPE insulated PVC sheathed power cable of 1.1 KV grade of 2 x 10 sqmm size Aluminum armoured cable direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 23 | Supplying and laying of one number XLPE power cable of 1.1 KV grade of 2 x 10 Sqmm size in the existing PVC/ METAL pipe/open as required. |
| 24 | Add Cost index @ 17% on total DSR item Please Enable Macros to View BoQ information |