| 1 | CIVIL WORKS |
| 2 | COMPUTETR TABLE Providing making & supplying a computer table made out of 19mm commercial ply for the table top, mounted on the vertical side of 19mm commercial ply and cabinet made out of 19mm commercial ply for sides, shelves & shutters making concealed monitor arrangement by providing 8mm thick clear glass on table top of required size with edge polish as shown in drawing drawer and ready made key board drawer with heavy sliding channels with powder coated handle for shutter, cable manager drawers all edges shall be lipped with 6mm thick T.W. lipping patti. All exposed faces should be a 1.5mm thick laminate of approved colour, and non-laminated areas should be French polished, including cost of other materials, labor, etc., as per drawing and as specified and directed by Engineer-In-Charge. Computer Table with all inner surfaces with 1mm thick approved laminate. |
| 3 | OPEN SHELF Providing and fixing in position shelf of required size made of 19mm thick ply of approved make with T.W. lipping patti of 6mm thick of required size to all exposed surface with 1.5mm approved laminated on top of the shelf mounting over the bracket made out of 40mm x 40mm T.W section bracket with French polish to all required places and all laminated surface with bracket etc. complete all specified and directed by Engineer-in-Charge. Shelf made out of 19mm plywood with brackets at 1.00 m center to center. |
| 4 | WOODEN CABINET DRAWER UNIT Providing & fixing a cabinet drawer unit (movable with wheels) made up of 19 mm commercial ply of approved make for the top, bottom, sides & shelves, & 8mm commercial ply approved make for the backside. The door shutter made up of 19mm thick commercial ply and the outer surfaces and top of shelves for open-type cabinets should be laminated with 1.5mm thick approved plastic laminate sheet of the required color including all brass fittings such as hinges, tower bolts, ball catches, stopper, handle, knobs as per shown in the drawing or approved by Engineer-In-Charge, etc. and all exposed edges lipping with 6mm Thick T.W. lipping patti. locking arrangement with Godrej multipurpose lock etc. all complete as specified & directed by the Engineer-In-Charge. with inner side 0.8mm thick Laminate with shutter. |
| 5 | WOODEN VERTICLE STORAGE UNIT Providing & making of a fully drawer storage unit made up of 19mm thick. Commercial plywood with heavy-duty sliding channel & with 6mm thick commercial plywood for the back. 19mm plywood for the top, bottom, and front of shelves. Side of the drawer to be 12mm thick & bottom to be as per the requirement. 1mm thick approved laminate to be fixed on the exposed surfaces of the unit. All faces are to be laminated. Including items such as lock, hinges, tower bolt, and handle to be of heavy-duty & approved make only, all complete as specified & directed by the Engineer-In-Charge. |
| 6 | PVC WORK Providing & fixing Fiber Reinforced Cement Panels with tongue & groove joints of 50mm thick fixed in between vertical 25x50mm wide GI channels and 50x50mm GI channels at floor & ceiling level with screws, filling the joints with birla wall care putty finished smooth complete all inclusive of wastage, making provision for opening and providing additional GI channels around openings etc. as directed & instructed by EIC. |
| 7 | Providing and applying white cement-based waterproof putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 8 | WATER PROOF PLASTER: Providing and laying water proof cement plaster 20mm in two coat backing coat of 12mm thick in CM 1:3 and second coat 8mm thick in CM 1:3 finish including supplying and adding water proofing compound weight of cement at all floor levels for repair to chambers, manholes, water retaining structures, depressions in bath/WCS etc. in quantities as required at site including scaffolding, curing layer will be allowed to air cure for 4hours followed with water curing for 48 hours, hacking of concrete surface etc. complete all as directed by engineer-in-charge (to maintain bone dry condition underneath for 10 yrs) The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipe sand masonry with polymer mixed slurry. (Rates also includes disposing/taking away the debris outside the premises of ACTREC and disposing as per the statutory guidelines) |
| 9 | Providing & Applying one / two coats of primer & thereafter two coats of paint as mentioned below of approved make first quality Asian Paints (Apcolite) / Goodlass Nerolac/ ICI to the required colour scheme and as per manufacturers instructions/specifications to the walls, beams, columns, ceilings, partitions doors etc. including thoroughly scrapping the existing surface with sand papers, removing old paint, filling up crevices and Applying and Levelling the existing surface with Birla White Cement based / Coloured waterproof Putti/POP Coat of average thickness of 1 mm or 2 mm as per requirements of approved brands necessary to obtain smooth surface, filling of cracks, removal of stains, painting spots on floors, aluminium window frame & glass etc. including scaffolding etc. as to the entire satisfaction of engineer in charge.: Using Luster Paint. |
| 10 | PLYWOOD Providing & fixing approved quality machine pressed phenol formaldehyde bonded commercial/marine plywood of approved size and fixing the same with necessary nails/screws/adhesive in partition cupboard shelves/kitchen cabinets/flush doors etc. at all floors and locations in quantities as required at the site in following thickness including 6 mm thick T.W. lipping patti at all exposed edges with nails/screws/hardware/adhesive wastage in cutting, transportation, etc. complete all as directed by the Engineer-In-Charge.: 19mm thick ply |
| 11 | LAMINATE Providing & fixing 1.5 mm thick approved laminate of required colour over existing surfaces along with the adhesive, all as required specification design, etc., complete as specified and directed by Engineer-In-Charge.: 1.5 mm thick. |
| 12 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.: For thickness of tiles 10 mm to 25 mm. |
| 13 | CONCRECTE BREAKING: Breaking of the existing concrete by chiselling at all level including scaffolding and staging and the work shall be carried out so as to cause minimum inconvenience to hospital activity including cost of all material, labour, tools etc. carting away the debris out of hospital premises all complete as specified and directed.: R.C.C. work (lintel, beams etc.) manually/mechanically |
| 14 | Providing and fixing Aluminium Composite Panel (ACP) curtain wall system of 4mm thick matching existing ACP Panel or approved colour and make fixing over aluminium frame of 50mm x 25mm thick in grid form including cutting bending, ACP to required size and shape, fixing on Aluminium frame with weather Silicon sealant and finishing the groove with black colour sealant as per manufacturer’s specification complete all inclusive of wastage, labour, shifting, transportation etc. as directed and instructed by Engineer incharge. |
| 15 | Providing & Fixing Baffle-type false Ceiling with Metalworks Blade/ Linear Panels. Durable metal vertical panels in multiple sizes with swivel attachments. Pre-coated wood-look finishes. Standard sizes shall be 4\\" depth with 1\\" width with end caps, both field cut and factory applied as applicable. Design pattern to be submitted for approval. Suspension system to be provided with non-corrosive metal or galvanised metal with additional supports. |
| 16 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.|. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high, having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering up to 150 mm on both sides of the joint and two coats of primer suitable for board, all as per the manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with a frame of perimeter channels suitably fixed, All complete as per drawings, specification, and direction of the Engineer-in-Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant plain board conforming to IS: 2095- (Part I):2011 (Board with BIS certification marks) |
| 17 | Removing the existing false ceiling & existing AC duct of any material and any size with all necessary allied works, including removing and refixing existing smoke detectors 10 nos., ceiling speakers 01 nos., and wall speakers 04 nos., along with disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by the Engineer-in-charge. |
| 18 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.: GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electrostatically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 19 | Providing & fixing acoustic foam polester fibre panels, wall cladding of thickness 09mm or 12mm mounted on 12 mm plywood with NRC value from 0.6 to 0.9, Density 2000 GSM acoustical paneling with approved color and pattern, with factory-made CNC cut geometric design or printed on as per design instructions or selection as specified by EIC. Panelling shall be fixed with specific glues or specified material as per OEM. Complete & finished in all respects, including all accessories and hardware required for the same. The rates are inclusive of plywood. Plywood is also to be erected and mounted to make the surface preparations. |
| 20 | Disposal of building rubbish / malba / similar unserviceable, dismantled, or waste materials by mechanical means, including loading, transporting, and unloading to an approved municipal dumping ground or as approved by the In-charge, out of ACTREC campus premises for all leads, including all lifts involved. |
| 21 | ELECTRICAL WORKS |
| 22 | Primary Light Points: SITC of Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing thepoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 23 | Secondary Light Points: SITC of Secondary light point from first light point to second light point connected in the same switch ie looping point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required. |
| 24 | 1.5 sq. mm ISI marked single core, PVC insulated, FRLS, flexible copper conductor wires, for interconnections. |
| 25 | 25mm PVC FLEXIBLE CONDUIT Supply & laying/replacement of PVC flexible conduit conforming to ISI standards & approved make with required number of coupling, PVC bushes, check nuts etc complete all as per instruction of EIC. In case of replacement, removed parts, items etc. shall be returned to ACTREC as it is. |
| 26 | Supply, installation of 22W,4' long surface-type LED lighting fixture |
| 27 | Supplying, installation, Testing & Commissioning of 5watt to 8watt LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement |
| 28 | Supplying, installation, Testing & Commissioning of LED strip with 240 LEDs per mtr with profile |
| 29 | Supplying, installation, Testing & Commissioning of LED strip LED driver 5/15A |
| 30 | Supplying and fixing the 8 Modules, PVC box, modular base & cover plate for modular switches in surface / concealed, etc. as required. |
| 31 | Supplying and fixing the 6A/16A modular switch on the existing modular plate & switch box including connections etc. as required. |
| 32 | Supply & Fixing of 25 mm size PVC rigid conduit with spacers & saddles screws, rawal plug etc. along with all accessories complete in all respect on any hard surface/wall/trench/ceiling etc. Compete as per instruction of EIC. |
| 33 | Supply & Fixing of casing capping of 1.25Inch size with screws, rawal plug etc. along with all accessories complete in all respect on any hard surface/wall/trench/ceiling etc. Complete as per instructions of EIC. |
| 34 | Dismantling / removing the existing light, fan, bell, independent plug point, wiring of all types with accessories, Switch boards etc to the satisfaction of In-charge. All dismantled/removed/scrap material to be handed over to Engg. Dept as it is. Please Enable Macros to View BoQ information |