Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge |
| 2 | All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 9 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 12 | Foundations, footings, bases of columns, etc. for mass concrete |
| 13 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 15 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in |
| 17 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 18 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1 :4 (1 cement: 4 coarse sand ).The rate includes providing and placing in position 2 Nos 6 mm dia M.S.bars at every third course of masonry work |
| 19 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 20 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 21 | Granite stone slab of colour black, Cherry/Ruby red |
| 22 | Area of slab over 0.50 sqm |
| 23 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 24 | Granite work |
| 25 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 26 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick |
| 27 | Float glass panes |
| 28 | 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 29 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading |
| 30 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 31 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): |
| 32 | Rectangular or square |
| 33 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 34 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete |
| 35 | 2nd class teak wood |
| 36 | 50x20 mm |
| 37 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : |
| 38 | 100x60x2.50 mm |
| 39 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality |
| 40 | 1.5 mm thick |
| 41 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). |
| 42 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). |
| 43 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. |
| 44 | Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. |
| 45 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge, Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge |
| 46 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 47 | Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 48 | Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi point locking system. (Height above 1.8m) |
| 49 | Fixed window/ventilator with mullion/transom |
| 50 | Using R1 series with frame (33mm & above) x (35 mm & above) & both glazed and fly screen sash (33 mm & above) x (50mm & above) (Height upto 0.90 metre). |
| 51 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 52 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer in-charge: |
| 53 | Profile C |
| 54 | Fixing with adjustable lugs with split end tail to each jamb |
| 55 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 56 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 57 | Hot finished welded type tubes |
| 58 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 59 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 60 | Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 61 | 10 x 60 mm |
| 62 | 10 x 80 mm |
| 63 | 10 x 120 mm |
| 64 | 10 x 140 mm |
| 65 | 10 x 160 mm |
| 66 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 67 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors complete. |
| 68 | Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. |
| 69 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 70 | Double charge vitrified tile polished finish of size |
| 71 | Size of Tile 600 x 600 mm |
| 72 | Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. |
| 73 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 mm thickness. |
| 74 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 75 | Size of Tile 600x600 mm |
| 76 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge |
| 77 | Size of Tile 600x600 mm |
| 78 | Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. |
| 79 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 80 | 110 mm diameter |
| 81 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion |
| 82 | Coupler |
| 83 | 110 mm |
| 84 | Single tee with door |
| 85 | 110 x 110 x 100 mm |
| 86 | Bend 87.5° |
| 87 | 110 mm Bend |
| 88 | Shoe (Plain) |
| 89 | 110 mm Shoe |
| 90 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete |
| 91 | 110 mm |
| 92 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 0x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws@ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 93 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 94 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 95 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete |
| 96 | Flashings/ Aprons.( Upto 600 mm) |
| 97 | Gutter (600 mm over all girth) |
| 98 | Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per directions of Engineerin- Charge. |
| 99 | 12 mm cement plaster of mix : |
| 100 | 1:4 (1 cement: 4 coarse sand) |
| 101 | 15 mm cement plaster on rough side of single or half brick wall of mix |
| 102 | 1:4 (1 cement: 4 coarse sand) |
| 103 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 104 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 105 | New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. Over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 106 | Applying priming coat: |
| 107 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 108 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 109 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacturer. |
| 110 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 111 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour |
| 112 | Two coats |
| 113 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 114 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 115 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 116 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 117 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 118 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 119 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead. |
| 120 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 121 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 122 | Semi rigid pipe |
| 123 | 40 mm dia |
| 124 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 125 | Providing and fixing floor mounted, white vitreous china single piece,double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings andfixtures with seat cover, cistern fittings, nuts, bolts and gasket etcincluding making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 126 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls |
| 127 | 20 mm nominal dia Pipes |
| 128 | 32 mm nominal dia Pipes |
| 129 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc..Internal work- Exposed on wall |
| 130 | 25 mm dia nominal bore |
| 131 | Providing and fixing G.I. pipes complete with G.I. Fittings including trenching and refilling etc. External work |
| 132 | 25 mm dia nominal bore |
| 133 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 134 | 25 mm dia nominal bore |
| 135 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 136 | 45 cm length |
| 137 | 15 mm nominal bore |
| 138 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 139 | 25 mm diameter pipe |
| 140 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. Complete (New work) : |
| 141 | 25 mm dia nominal bore |
| 142 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 143 | 15mm nominal bore |
| 144 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 145 | Upto 5 mm depth and 5 mm width |
| 146 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 147 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black), comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 148 | With 15 mm thick integral density micro edge light weight calcium silicate false ceiling tiles. |
| 149 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 150 | With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
| 151 | With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 152 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 153 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 154 | Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800-1984 and IS:8011975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ ArchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/ slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. |
| 155 | Providing and fixing of external wall system on Light gauge steel frame work with outer face cement boards as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make. A groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. Internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with selfdrilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately) |
| 156 | Outer face: Outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, Type A, as per IS:14862:2000 (high pressure steam cured) Inner Face :- 12.5 mm thick gypsum plaster board conforming to IS 2095:2011 fixed on 8 mm thick fibre cement board confirming to IS:14862:2000 of type B (High pressure steam cured) |
| 157 | Providing and fixing internal wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on cement board as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately |
| 158 | Cement Fiber Board 8 mm thick as per IS 14862:2000 of type B (High pressure Steam Cured) |
| 159 | Providing and fixing in all exterior face panels breathable vapour barrier underneath the cement fiber board as per National Building Code 2009 complete as per direction of Engineer-in-charge |
| 160 | Supplying and installation of moisture resistant/fire resistant cement board as per standard sizes fixed with self-drilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm |
| 161 | Cement Fiber Board 6 mm thick as per IS 14862:2000 of type B (High pressure Steam Cured) |
| 162 | Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100grams/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building / scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) |
| 163 | S/F of 100 mm wide vertical blinds NEHA/VISTA/CLASSIC or any other equivalent approved brand with prior approval of EIC, complete in all respect. |
| 164 | Providing & Fixing of rolling blinds NEHA/VESTA/CLASSIC or any other equivalent approved brand with prior approval of EIC, complete in all respect. |
| 165 | Providing laying and jointing 75 mm dia SWR pipe single socket type B of Ist quality prince make or equivalent approved make complete in all respects as per directions of EIC |
| 166 | Providing laying and jointing 90mm dia SWR pipe single socket type B of 1st quality prince make or equivalent approved make complete in all respect as per direction of EIC. |
| 167 | Providing laying and jointing 110mm dia SWR pipe single socket type B of 1st quality prince make or equivalent approved make complete in all respect as per direction of EIC. |
| 168 | Providing and fixing CP brass Basin inlet connection angle valve ESSCO make model no. SQT-526NKM or equivalent approved make etc complete as per direction of EIC. |
| 169 | Providing and fixing shower Jaquar make model no. OHS-1605 (150x150mm) or equivalent approved make as per direction of EIC. |
| 170 | Providing and fixing shower arm 400x25x25 mm square shape for wall mounted showers with flange Jaquar make model no. SHA 455L 400 or equivalent approved make as per direction of EIC. |
| 171 | Providing and fixing health faucet with 8mm dia. 1 meter long flexible tube & wall hook. Jaquar make model no. ALD-573 or equivalent approved make as per the direction of EIC |
| 172 | Providing and fixing Bowl with Cistern for Extended wall hung WC with PP soft close seat cover, Hinges, Dual Flush cistern fitting. Accessories set, size 380x630x770 mm jaquar make model no. CNS-WHT-353SPPZ or equivalent approved make as per directions of EIC |
| 173 | Providing and fixing under counter wash basin with fitting accessories size 485x370x205 mm shape rectangular Jaquar make model no. CNS-WHT-701 or equivalent approved make as per direction of EIC |
| 174 | Providing and fixing wall hung full padestal wash Basin with fixing Accessories size 560x415x200 mm pedestal jaquar make model no. CNS-WHT 801 & CNW WHT 301 or equivalent approved make as per directions of EIC. |
| 175 | Providing and fixing CP brass angular stop cock with valve flange Jaquar Make Model No. CON-059KN or equivalent approved make as per directions of EIC |
| 176 | Providing and fixing CP brass pillar cock Auto closing system jaquar Make Model No. PRS-031 or equivalent approved make as per directions of EIC |
| 177 | Providing and fixing CP Brass Toilet paper holder of Jaguar make (Model ACN-1153N) or equivalent approved make with CP Brass Screws etc all complete as per the direction of Engineer- in-charge. |
| 178 | Providing and fixing bottle trap of Jaquar make 32 mm size with 250mm x190mm long wall connectionn pipe & wall flange model no. ALD-PHR 769L 250x190 or equivalent approved make as per the direction of Engineer-in-charge |
| 179 | Providing and fixing Towel ringround with round flange of Jaquar make (Model no. CAN-1121BN) or equivalent approved make approved make fixed with CP brass screws etc. complete as per directions of the Engineer in charge. |
| 180 | P/F CP brass bib cock jaquar make CON-047KN with wall flange or equivalent of approved make as per directions of Engineer in Charge. |
| 181 | Providing and fixing 15mm long body bib cock of Jaguar make Model no. CON-107KN or equivalent approved make as per direction of Engineer In-charge. |
| 182 | Providing and fixing 75 mm dia upvc nahani trap with material and labour etc complete as per directions of EIC |
| 183 | Providing and fixing 100 mm dia CP floor jali (Heavy Duty) as per direction of EIC |
| 184 | Brick work with old bricks (supplied free of cost at our stores) in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 185 | Half brick masonry with old bricks (supplied free of cost at our central stores) in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand) masaonry with old bricks (1:4 cm) etc. complete in all respects as per directions of EIC |
| 186 | Brick work with old bricks (supplied free of cost at our stores) in foundation and plinth in: Cement mortar 1:4 (1 cement:4 coarse sand) |
| 187 | Providing and fixing 35 mm thick ISI mark ply flush door shutters non-decorative type of century ply make or equivalent approved make complete in all respects as per directions of EIC |
| 188 | Providing and fixing 32 mm thick ISI mark flush door shutters non-decorative type of centuryply make or equivalent approved make complete in all respects as per directions of EIC |
| 189 | Providing and fixing SS Sliding door bolts of 200 x 16 mm with nuts and screws etc. complete as per direction of Engineer-In-charge |
| 190 | Providing and fixing mortice handle lock with of doorset make model no. Cetto |
| 191 | Providing and fixing hydraulic door closer Godrej make or equivalent approved make with necessary accessories and screws etc. complete in all respects as per directions of EIC |
| 192 | Providing and fixing of white glazed earthenwave half stall (Flat Back Large) urinal 1st quality HINDWARE, CERA, PARRYWARE make of required specials fitting and 32mm dia G.I. waste pipe etc complete in all respects as per directions of E.I.C. |
| 193 | Providing and fixing urinal valve auto closing system with built in control cock & wall flange jaquar make Model no PRS- 077 or equivalent of approved make as per directions of the engineer in charge. |
| 194 | Providing, mixing and applying 12 mm thick ready mix cement plaster of approved make as per specifications and directions of Engineer-in-charge. |
| 195 | Providing, mixing and applying 15 mm thick ready mix cement plaster of approved make as per specifications and directions of Engineer-in-charge. |
| 196 | Providing and fixing 32 mm dia UPVC ISI (Class-4) - 8 kg/cm² working pressure pipe swith necessary cutting to be done to the required length including short pieces, jointing with solvent, assorted fittings such as elbow etc. complete as per direction of engineer in charge. |
| 197 | Providing and fixing rubber back door silencer/ stopper 50 mm with necessary screws etc. complete as per direction of Engineer-In-charge |
| 198 | Providing and fixing regular body of concealed stop cock suitable for 15mm pipe line with plastic protection cap of Jaquar make ALD-083FT or equivalent approved make along with compatible exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange of Jaquar make CON-083FTK or equivalent approved make complete as per direction of EIC. |
| 199 | Providing and fixing curved shaped urinal partition with frosted glass of size 900mm x 450 mm x 10 mm (Chrome finished) thick Jaquar make of model no. JSE-CHR-110UC450X or of equivalent approved make as per direction of EIC. |
| 200 | Providing and fixing curved shaped urinal partition with frosted glass of size 900 x 450 x 8 mm (Chrome finished) thick Jaquar make of model no. JSE-CHR-810UC450X or of equivalent approved make as per direction of EIC. |
| 201 | Providing and laying heavy duty tiles in size of Tile 600x600 mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including joints grouting of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 202 | Providing and laying heavy duty tiles in size of Tile 600x600 mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness including joints grouting of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer in Charge. |
| 203 | Providing and fixing 250x16 mm size Stainless Steel Aldrop of Dorset make model no. ALDSM (250x16) or equivalent approved make with nuts and SS screws etc. complete. |
| 204 | Providing and fixing Door mounted hanging type Door Stopper of Dorset make model no. DS HT (Z) or equivalent approved make with SS screws etc. complete. |
| 205 | Providing and fixing 10 inch length and 10mm dia square shape Stainless Steel tower bolts of Dorset make model no. TS-1010-10\\" or equivalent approved make with SS screws etc. complete. |
| 206 | Providing and fixing 12 inch length and 10mm dia square shape Stainless Steel tower bolts of Dorset make model no. TS-1210-12\\" or equivalent approved make with SS screws etc. complete. |
| 207 | Providing and fixing 2 x 150 mm size bright /matt finished Stainless Steel cabinet handles of kich make model no. PRCH426C or equivalent approved make with SS screws etc all complete |
| 208 | Providing and fixing 2 x 125 mm size bright /matt finished Stainless Steel Cabinet handles of kich make model no. PRCH425C or equivalent approved make with SS screws etc all complete |
| 209 | Providing and fixing prefabricated sandwiched Polyurethane Foam Panel (PUF panel) on Roof having overall thickness of minimum 80 mm and base thickness without corrugation of minimum 50 mm, having density of PU foam 40± 2 kg/cum, the top covering on the roof panel of Tapezoideal Precoated Galvanized iron sheet of total coated thickness 0.5mm (pitch of corrugation as approved by Engineer-in-charge) and bottom covering of micro ribbed precoated galvanized iron sheet of total coated thickness 0.5mm, for both sheets base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm with zinc coating 120 grams per sqm as per IS: 277, in 240 MPa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The PUF panel shall be fixed using self drilling / self tapping screws of required size with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surface, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 210 | Fixing glazed/ceramic/Vitrified floor tiles with cement based high polymer modified quick set tile adhesive (Water based) conforming to IS 15477, in average 6mm thickness (600 x 600mm) |
| 211 | Providing & Fixing upvc louers strips in UPVC window with male and female brakets approved as per direction of Engineer In-charge |
| 212 | Providing and fixing beveled edge mirror of superior glass (of approved quality and required size) complete with 6 mm thick cement bonded particle board ground fixed to spacers with C.P. brass/SS screws and washers etc all complete as per direction of the Engineer in charge. |
| 213 | Providing and fixing SS Hanger with Four nos cloth pegs to be fixed with C.P. brass screws complete as per directions of the engineer-in-charge. |
| 214 | Providing and fixing 1.00 mm thick deck sheeting (including shear connectors/stud of 19mm dia. & 110mm height) for RCC slabs as per specifications including fixing the same. The contractor shall take all precautions to prevent any bending in sheeting. (RCC & R/F shall be paid seperately). Plan area shall be measured for payment. The vendor must be able to supply 2hr fire rating for deck sheet with concrete. The deck sheet must have minimum zinc coating of 275 g/m2 (Plan Area shall be measured for Payment) |
| 215 | P/F Door set floor spring Model No. CS100 GM |
| 216 | Providing and fixing 5mm thick toughened glass etc. complete as per direction of engineer in charge |
| 217 | For Calculation purpose only |
| 218 | Sub Total (A) |
| 219 | Supplying and Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge with modular type switch, modular plate,suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc as required. |
| 220 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. |
| 221 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc. as required.. |
| 222 | Supplying and Wiring for circuit/ submain line with 2x2.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge along with 1 no 2.5 mm² FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 223 | .....do..... but 2x4 mm² + 1x4 mm² earth wire |
| 224 | .....do.....but 2x6 mm² + 1x6 mm² earth wire |
| 225 | .....do..... but 2x10 mm² + 1x6 mm² earth wire |
| 226 | .....do..... but 2x16 mm² + 1x6 mm² earth wire |
| 227 | .....do..... but 4 X 4 mm² + 2 X 4 mm² earth wire |
| 228 | .....do..... but 4 X 6 mm² + 2 X 6 mm² earth wire |
| 229 | .....do..... but 4 X 10 mm² + 2 X 6 mm² earth wire |
| 230 | .....do..... but 4 X 16 mm² + 2 X 6 mm² earth wire |
| 231 | Supplying and drawing of 2x2.5 sq mm FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired. |
| 232 | 3x2.5 sq mm |
| 233 | 5x2.5 sq mm |
| 234 | 6x2.5 sq mm |
| 235 | 2x4 sq mm |
| 236 | 3x4 sq mm |
| 237 | 5x4 sq mm |
| 238 | 6x4 sq mm |
| 239 | Supplying and fixing stepped type electronic fan regulator on existing modular type plate & switch box including connections but excluding modular plate etc. as required. |
| 240 | .....do..... but modular blanking plate. |
| 241 | S/F of 2.8 to 3 mm thick phenolic laminated bakelite sheet including cutting as required with brass machine screw and cup washer complete. |
| 242 | Providing and fixing 125 amp, 16 KA, rating and breaking capacity TP MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. |
| 243 | .....do..... but 250 amp 35 KA MCCB |
| 244 | .....do..... but 630 amp 50 KA MCCB |
| 245 | Supplying and fixing of 8 way (4+24) double door horizontal type three pole and neutral sheet steal MCB distribution board, 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. |
| 246 | Supplying, installation, testing and commissioning of surface/ recess mounting, vertical type, 415 volts, prewired, TPN MCB distribution board of sheet steel, dust protected, duly phosphatized and powder painted, inclusive of 200 amps tinned copper busbar, common neutral link, earth bar, din bar for mounting MCB's , detachable gland / knock out plate and superior make terminal connectors for all incommining and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link and ready for installation of 8 ways (4+24) double door (but with out MCB's and incommer MCCB) as required. |
| 247 | ..do..but12 way (4 + 36), double door VTPN DB |
| 248 | Supplying and fixing Cable End Box (Loose Wire Box) suitable fortriple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 249 | Supplying and fixing 5 amps to 32 amps rating single pole, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 250 | .....do..... but 5 to 32 amp DP MCB |
| 251 | .....do..... but 40 to 63 amp TP MCB |
| 252 | .....do..... but 5 to 32 amp 4P MCB |
| 253 | .....do..... but 40 to 63 amp 4P MCB |
| 254 | .....do.....but 40 A amps DP RCCB |
| 255 | .....do.....but 63 amps 4P RCCB |
| 256 | Supplying and fixing 2P/4P MCCB sheet steel enclosure on surface/ recess for 415 volts with suitable bus bar for neutral including connections, testing and commissioning etc. as required. |
| 257 | SITC of 240 V, 250 MM sweep PVC body exhaust fan in existing opening and making good finish with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 258 | Supply, Installation, Testing and Commissioning of 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum), ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply earthing etc. complete as req |
| 259 | Supplying, Installation,Testing & commissioning of 36 watt panel light 2*2 fr of following body material and construction as per IS: 10322 with driver as per the requirement with driver efficiency >85 . |
| 260 | SITC of LED light fitting 600mm length minimum 1000Lumen with mounting rail box / aluminium extruded Batten suitable for surface, wall and conduit mounting with acessories and prewired with both side end cap equivalent to Wipro Cat no. LL20-111-XXX-65NE3. Minimum five years warranty should be provided. |
| 261 | SITC of Sensor LED tube fitting equivalent to WIPRO Cat No. LL28-221-5N-65-XX* with built in motion sensor and necessary arrangement to reduce to 30% in case of no occupancy or motion but instantly go to full light i.e. 18-20 watt as soon as some motion observed, complete with connection as required. Minimum five years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 262 | Supply and laying of copper conductor, XLPE insulated, armuored, PVC sheathed cable, 1100V grade, 4 core 35 mm² at a depth of 750mm below ground level including excavation and refling the trench over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly. |
| 263 | Do -- But 4 core 50 sqmm Aluminium armuored cable. |
| 264 | Do -- But 4 core 95 sqmm Aluminium armuored cable. |
| 265 | Do -- But 4 core 120 sqmm Aluminium armuored cable. |
| 266 | Supply and laying of copper conductor, XLPE insulated, armuored, PVC sheathed cable, 1100V grade, 4 core 300 mm² at a depth of 750mm below ground level including excavation and refling the trench over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly. |
| 267 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) |
| 268 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 269 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 270 | LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt ). 12-15 watt Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 271 | Supplying, Installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 272 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor mounted 800A cap 440 V, 50 HZ,3 phase and neutral electric feeder pillar single/ double door 400 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. ampere meter, volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB's/MCCB's, C/o switch with extentionable/rotary handle etc.). The feeder pillar/ panel shall have 800 Amp, 415V TPN electrolyte aluminium bus bar as per IS 8623 insulated with heat shrink sleeve and mounted on nonhygroscopic supports with detachable side with hinge and locking. The switches shall be completed with lug and cable gland of suitable size of cables with connection as required. The feeder pillar should be made with 2 mm CRCA sheet. The feeder pillar should be fixed on M.S. channel 75mm X 40mm X 6mm size and mounted on M.S. angle iron 50mm X 50mm X 5mm size frame 450mm height with cross support completed as per direction of site in charge. The panel shall be comprised of indicator and feeder nomenclature as per direction of site-in-charge. |
| 273 | Supplying and installaton following size 100 mm width X 50 mm depth X 1.6 mm thickness of perforatedpainted with powder coating M.S. cable trays withperforation not more than 17.5%, in convenientsections, joined with connectors, suspended from theceiling with two numbers MS/GI Suspenders i/c baseof suitable size MS/GI angle, bolts & nuts, paintingsuspenders, fastener etc as required. |
| 274 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 275 | 200 mm width X 50 mm depth X 1.6 mm thickness |
| 276 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 277 | PART A (Supply Installation Testing and Commissioning) |
| 278 | Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity > 40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC Building) |
| 279 | For Cooling and Heating Both |
| 280 | 14 HP |
| 281 | 16 HP |
| 282 | Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) |
| 283 | 2.6 TR |
| 284 | Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted mid high static ductable type Indoor unit equipped with washable synthetic media pre- filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same asof Outdoor) |
| 285 | High Static ductable units (minimum 49 to 77 Pascal external static pressure) |
| 286 | 3.2 TR |
| 287 | 4.0 TR |
| 288 | Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) |
| 289 | 2.0 TR |
| 290 | Ceiling Suspended/Floor Standing outdoor type DX AHU (TFA) |
| 291 | AHU Construction: - Supply, installation, testing and commissioning of factory built Ceiling Suspended double skin type DX Air Handling Units made of 48+/-2 mm thick panels (Density:40+/-2 KG/Cu.m.) consisting of G.I. Casing of thickness 0.8 mm pre-coated outside layer and 0.8 mm thick plain GI sheet inside layer with polyurethene foam (PUF) insulation factory injected between them by injection moulding machine, complete with plug fan suitable for static pressure as detailed below, cooling coil section with machanically bonded aluminium finned copper tubes (tube thickness not less than 0.3 mm) cooling coil, filter section with filter having filteration efficiency and particle size matching to MERV-8 Pre filters and Carbon filter, TEFC drive motor suitable for 415+10% volts, 50 + 3% Hz, 3 phase, A.C. supply, minimum IP 55, drain connections, with stainless steel drain pan made out of SS grade 304 sheet. duly insulated , and necessary vibration isolation arrangement etc. complete as per specifications of following capacities. |
| 292 | The unit shall be supplied with electronic expansion valve/s (Dx), thermostat/s, corded remote, control wiring, all accessories as required for completing the installation. The price shall be inclusive of these items. AHUs shall be of following design parameters: |
| 293 | Pre filter section: Pre filter section shall be with Non-woven synthatic media down to 10 micron particles size of 90% (MERV-8) |
| 294 | Post filter section:Filter section with Carbon filter |
| 295 | Cooling Coil :Copper tubes and Al fins 11-13 Fin/inch and copper header, coil size shall be selected for air velocity of 500 feet/minutes and velocity across filter at 500 feet per minutes. Water side pressure drops should not exceed 10 PSIG. |
| 296 | Fan and Motors: - AHU must have Airfoil design Plug type centrifugal Fan with IE3 energy efficiency motor. Fan motors shall be energy efficient with IE-3 grade with IP-55 protection. Motors shall be especially designed for quiet operation. Drive to fan |
| 297 | Plug type SISW Centrifugal direct driven plug fan with IE-3 energy efficiency motor and shall be 415+- 10% volts, 50 cycles 3 phase totally enclosed fan-cooled class-F with IP-55 protection. Drive to fan shall be provided through direct drive arrangement.Frequency converter (VFD for energy saving and smooth regulation of air flow shall be supplied by the AHU manufacturer for AHU's with direct drived plug fan. Fan impeller shall be selected for mimimum efficiency of 62.0% plug fan in fan array shalll have individual VFD's for everymotor fan set. |
| 298 | Accessories: |
| 299 | LED light with cable view port and cable gland should provide in fan sections by manufacturer. AHU sound pressure level should not be more than 65 db(A) at a distance of 1M from the unit. |
| 300 | UV lamps shall be installed in each AHU and density of UV light should be as required to kill medium of COVID-U19 virus. |
| 301 | Total static pressure of AHU & row deep of cooling coil shall be checked by Vendor as mentioned below: |
| 302 | Dehumidifier Air CFM 650, cooling coil row deep 8, Static pressure 75 MMWC, Motor KW 1.1 KW. |
| 303 | Supply, installation, testing and commissioning of Controller/Manager with touch screen display accessible through remote views to include the indoor plan layout view, icon view and list view and menus for system configurations. This will allow the users to put limitations on the maximum and minimum temperatures and ensures an appropriate room temperature. This system shall be compatible with connecting Minimum 256 nos. indoor units and remote access to a PC/ BMS through LAN/Wi-fi network. The controller enables monitoring of the VRF system's operation, including temperature, fan speed, and other parameters. |
| 304 | Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs |
| 305 | Indoor Units |
| 306 | Outdoor Multi Joints |
| 307 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 308 | 2.0 TR with 5 Star BEE Rating Inverter Type - Cooling only |
| 309 | 1.5 TR with 3 Star BEE Rating Inverter Type - Hot & Cold |
| 310 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : |
| 311 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 312 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 313 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 314 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 315 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 316 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 317 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 318 | 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 319 | 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 320 | Supply and applying of fibre glass cloth equal to Parafab-GFC (7mil) used protection of exposed pipe insulation with two coat of starbond 30-36 thermal insulation coating. |
| 321 | Supply, Installation, testing and commissioning of 10 KG Presure PVC pipe 25 mm dia size with 6 MM Nitrile insulation, complete with fittings, supports accessories in surface/recess as per specifications & site requirments |
| 322 | Supply, Installation, testing and commissioning of 10 KG Presure PVC pipe 32 mm dia size with 6 MM Nitrile insulation, complete with fittings, supports accessories in surface/recess as per specifications & site requirments |
| 323 | Supply, Installation, testing and commissioning of 10 KG Presure PVC pipe 40 mm dia size with 6 MM Nitrile insulation, complete with fittings, supports accessories in surface/recess as per specifications & site requirments |
| 324 | Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc. as required complete and all respect in confimtion with IS: 655 and approved drawings and specifications of following sheet thickness complete as required. |
| 325 | Thickness 0.63 mm sheet |
| 326 | Thickness 0.80 mm sheet |
| 327 | Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc. as required complete and all respect in confimtion with IS: 655 and approved drawings and specifications of following sheet thickness complete as required. |
| 328 | Thickness 0.63 mm sheet |
| 329 | Thickness 0.80 mm sheet |
| 330 | Supplying and fixing of 19 MM thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 331 | Supplying and fixing of following thickness duly closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 332 | 13 MM Thick |
| 333 | 9 MM Thick |
| 334 | Supply, Installation, Testing and Commissioning of 15mm thick ecosound (FR-Open Cell Cross Linked Polyethylene) for supply & return air ducts Acoustic lining inside ducts using Non Fibrous fire retardant crosslinked polyethylene foam of 30-60 +/- 3 Kg/m3 density & thickness of 15mm having porous surface on one side & a flat surface on other side using Synthetic rubber based Adhesive preferably Low VOC & high strength characteristic(Initial portion of ducting and main plenum) as per specifications |
| 335 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specififications complete etc. as required |
| 336 | Supplying & fixing of powder coated extruded aluminium supply Air Grills with aluminium volume control dampers complete in confirmation to SMACNA/IS and as per specififications complete etc. as required |
| 337 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core complete in confirmation to SMACNA/IS and as per specififications complete etc. as required |
| 338 | Supplying, fixing testing commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring and removable core complete in confirmation to SMACNA/IS and as per specififications complete etc. as required |
| 339 | Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, in confirmation to SMACNA/IS and as per specififications complete etc. as required |
| 340 | Supply and fixing of double layer Canvas connection for ductable uniit. |
| 341 | Sitc of 3 phase DOL (Direct online) motor starter 1 to 4 HP, relay range 1.5 to 6.5 Amp, along with all acessories complete with all connection as required . |
| 342 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor/wall mounted/ recessed/ surface feeder pillar / Panel double/ Single door , 150-200 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. Ampere meter, Volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB's/MCCB's, C/o switch with extentionable/rotary handle etc.) as required. The feeder pillar/ panel shall have nonhygroscopic supports with detachable side with hinge and locking. The panel/ feeder pillar should be made with 1.6 CRCA sheet. The panel shall be comprised of indicator and feeder nomenclature (if required) as per direction of site-in-charge. |
| 343 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor/wall mounted/ recessed/ surface feeder pillar / Panel double/ Single door , 200-250 mm depth duly powder coated spray painted with suitable Busbar up to 250 Amp capacity as required and separate chamber for instruments (e.g. Ampere meter, Volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB's/MCCB's, C/o switch with extentionable/rotary handle etc.) as required. The feeder pillar/ panel shall have nonhygroscopic supports with detachable side with hinge and locking. The panel/ feeder pillar should be made with 1.6 CRCA sheet. The panel shall be comprised of indicator and feeder nomenclature (if required) as per direction of site-in-charge. |
| 344 | Supplying and fixing 6 way (4 + 18), Double doorway, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 345 | Providing and fixing 250 amp, 35 KA, rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 346 | Supply and laying of following sizes Copper conductor, XLPE insulated, armoured, PVC sheathed cable, 1100V grade on existing cable tray with M.S. clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc. |
| 347 | 4 core 16 Sq mm |
| 348 | 4 core 10 Sq mm |
| 349 | 4 core 6 Sq mm |
| 350 | 4 core 4 Sq mm |
| 351 | 2C x 1.5 Sq mm. |
| 352 | 3 core 1.5 Sq mm. |
| 353 | Supply and laying of Copper conductor, XLPE insulated, Un-armoured, PVC sheathed cable, 1100V grade, 2 core 1.5 mm2 on existing RCC / HUME / METAL Pipe. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc. |
| 354 | Supply and laying of aluminium conductor, XLPE insulated, armuored, PVC sheathed cable, 1100V grade, 4 core 120 mm² at a depth of 750mm below ground level including excavation and refling the trench over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly. |
| 355 | Supply and laying of aluminium conductor, XLPE insulated, armoured, PVC sheathed cable, 1100V grade, 4 core 120 mm² on existing RCC / HUME / METAL Pipe of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc. |
| 356 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5/4.0 c x 120 sq.mm (45 mm) PVC cable insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 357 | Supplying and fixing of 25 MM medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 358 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 359 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 360 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 361 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 362 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 363 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 364 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 365 | Supplying and fixing 40 to 63 amp 4 Pole MCB rating , 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 366 | Supplying and fixing 40 amp , four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. |
| 367 | Supplying and fixing 63 amp , four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. |
| 368 | Supplying and fixing single pole 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 369 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete. |
| 370 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the TWO LOOP modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories.The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications with Auto dialer to notify/send SMS to designated Mobile no. the event of fire etc. on pre-programmed contact no. |
| 371 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 372 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 373 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 374 | Supplying Installation, testing & commissioning of Intelligent addressable thermal / smoke detector with rate of rise cum fixed temperature thermistor complete with base as required (Make :approved by EIC). |
| 375 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 376 | Supplying, Installation, testing & commissioning of addressable manual call point complete as required. (Make: approved by EIC) |
| 377 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 378 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 379 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 380 | Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required. |
| 381 | Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required. |
| 382 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 383 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit including connections and interconnections etc. as required. |
| 384 | speaker cable Two pair, 2-core, 1.5 sqmm |
| 385 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 386 | Providing and fixing of self illuminated / auto glow \\"EXIT\\" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 250 x 125 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. |
| 387 | S/F of fire extinguishers ABC type 6 kg capacity (ISI maked IS:2878 & TAC approved) complete with initial charge & wall bracket along with supply of all material and labour for proper completion of work. |
| 388 | S/F of fire extinguishers CO2 type 4.50 kg capacity (ISI maked IS:2878 & TAC approved) complete with initial charge & wall bracket along with supply of all material and labour for proper completion of work. |
| 389 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 390 | 20mm dia |
| 391 | 25mm dia Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail