| 1 | Lump sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 2 | Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY \\" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 3 | Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 4 | Lump sum price worked out by the contractor for \\"ROAD, PATH AND CULVERT\\" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 5 | Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL\\" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 6 | Lump sum price worked out by the contractor for \\"AREA DRAINAGE \\" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 7 | Lump sum price worked out by the contractor for \\"FENCING AND GATE\\" as listed in Schedule ‘A’ Part-VII\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 8 | Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 9 | Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 10 | Lump sum price worked out by the contractor for \\"LIGHTENING PROTECTION\\" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 11 | Lump sum price worked out by the contractor for \\" SUMMER APPLIANCES \\" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 12 | Lump sum price worked out by the contractor for \\"HOT WATER SUPPLY\\" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 13 | Lump sum price worked out by the contractor for \\"FLAME PROOF LIGHTING\\" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 14 | Lump sum price worked out by the contractor for \\"FOOTBALL/BASKETBALL/VOLLYBALL/PARADE GROUND\\" as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 15 | Lump sum price worked out by the contractor for \\"APRON AND ASSEMBLY AREA FOR 6 BLOCKS OF \\"B\\" VEHICLE GARAGES as listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 16 | Lump sum price worked out by the contractor for \\"SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK\\" as listed in Schedule ‘A’ Part-XVI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 17 | Lump sum price worked out by the contractor for \\"DEMOLITION WORK\\" as listed in Schedule ‘A’ Part-XVII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 18 | Sch 'A' Part-XVII MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XV (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule). |
| 19 | INTERNAL WATER SUPPLYS&F 15 mm CP 2-in-1 stop cock/bib tap fancy type for fixing of health faucet or jet spray for the WC and complete all specified and as directed. |
| 20 | S&F Brass SS Jet Spray with 1 m pvc tube and complete all as specified and as directed. |
| 21 | INTERNAL ELECTRIFICATIONS&L Finolex's RG6 cable for TV point complete all as specified and directed |
| 22 | S&F of TV socket 1 module 230 volts AC complete all as specified and directed. |
| 23 | Supply and install, testing wall termination Telephone socket RJ-11all as specified and directed by Engr in Charge. |
| 24 | S&F blanking plates complete all as specified and directed. |
| 25 | S&F of lamp holder, including 9 watt LED Bulb insulated body with back plate suitable for batten fittings and complete all as specified and directed. |
| 26 | S&F for highbay light 70/80 watts complete all as specified and directed. |
| 27 | S & F LED bed side reading light fitting white/black powder coated housing with movable string, metalic base,complete with driver to operate on 240V AC 50 Hz, suitable for indoor application and complete all as specified and directed. |
| 28 | S&F Sheet metal enclosure distribution board VTPN,6 way, 415 volt, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with pcc works complete all as specified and directed. |
| 29 | S&F Sheet metal enclosure distribution board VTPN,4 way, 415 volt, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with pcc works complete all as specified and directed. |
| 30 | M&L for concealed flame proof point wiring (using red, black and green colour wires as colour coding for single phase circuit) for one light point complete with 1.50 Sqmm (nominal cross sectional area) FRLSH PVC insulated unsheathed and multistranded copper conductor cable 1100 V (ISI Marked) for main point and for continues as earth wire connected to earth dolly etc (Phase, neutral and earth wire) drawn through and including ERW steel rigid heavy duty stove enamelled conduit with all flame proof fittings and all accessories e.g pipe bend, union socket, elbow, connector, reducer, pipe hook etc for light/fan points including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using CM(1:3) complete all as specified and as directed by Engr-In-Charge. Note: (i) Two nos of light point circuits shall be controlled by one rotaty switch/MCB fixed in existing DB. (ii) Rotary Switches, junction box, MCB shall be measured and paid separately under appropriate item of this Sch. |
| 31 | Supply and fixing (Concealed in wall) factory made flameproof DB Duly painted, 4 way dust and vermin proof including operatin Knob, cable glands, earth bar, bus bar with all accessoreis and comprising of the followingincluding taking out old Unserviceable existing DB any type complete all as specified and as directed by Engr-In-Charge. (i) MCB B Curve, SPN 32 Amps, 10 KA-01 Nos (Incoming) (ii) MCB B Curve, SP 6 Amps, 10 KA-02 Nos (Outgoing). |
| 32 | ROAD PATH AND CULVERTS&F ABS Speed Breaker/Rumbler of height 50mm and width 380mm in two colour of length 500mm each fixed alternately with reflectors on either side complete fixed with epoxy and bolts by drilling 6mmx75mm dia fastener as per manufacture instruction complete all as specified and directed. |
| 33 | S&F convex mirror having 130 degree of viewing angle made of one piece polycarbonate lens size of 0.80 mtr dia protect with any type of light ray not produce toxic fumes if burnt complete all as specified and directed. |
| 34 | SEWAGE DISPOSAL S&F factory made (SFRC) precasted reinforced cement concrete manhole cover as required thickness not less than 60mm of size 1420mm x 710mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and directed. |
| 35 | S&F factory made (SFRC) precasted reinforced cement concrete manhole cover as required thickness not less than 60mm of size 1200mm x 600mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and directed. |
| 36 | EXTERNAL WATER SUPPLY Supply , laying and testing Ductile Iron pressure pipe of 200 mm bore with spigot and socketed ends centrifugally cast, Class K-7, conforming to IS: 8329/2000 - blast furnace slag cement with portland cement properties suitable for push-on-jointing (Rubber tyton joints) with inside cement mortar lining with internal metallic zinc coating and external Black Bitumen coating complete all as specified and as directed by Engr-in-charge.Note:- Cost of joints including jointing material shall be deemed included in unit rate quoted by the tenderer. Earth work & DI specials/ fittings shall be measured & paid separately. |
| 37 | Supply , laying and testing Ductile Iron pressure pipe of 150 mm bore with spigot and socketed ends centrifugally cast, Class K-7, conforming to IS: 8329/2000 - blast furnace slag cement with portland cement properties suitable for push-on-jointing (Rubber tyton joints) with inside cement mortar lining with internal metallic zinc coating and external Black Bitumen coating complete all as specified and as directed by Engr-in-charge.Note:- Cost of joints including jointing material shall be deemed included in unit rate quoted by the tenderer. Earth work & DI specials/ fittings shall be measured & paid separately. |
| 38 | Supply , laying and testing Ductile Iron pressure pipe of 100 mm bore with spigot and socketed ends centrifugally cast, Class K-7, conforming to IS: 8329/2000 - blast furnace slag cement with portland cement properties suitable for push-on-jointing (Rubber tyton joints) with inside cement mortar lining with internal metallic zinc coating and external Black Bitumen coating complete all as specified and as directed by Engr-in-charge.Note:- Cost of joints including jointing material shall be deemed included in unit rate quoted by the tenderer. Earth work & DI specials/ fittings shall be measured & paid separately. |
| 39 | Supply and fixings Cast iron Air valves with two air outlets 150 mm dia bore conforming to IS 14845:2000 and PN-1.6, ISI Marked including , Gasket complete with nuts ,bolts and washers complete all as specified. |
| 40 | Brick masonry valve pit of size 120X120X120 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces complete all as specified. |
| 41 | Brick masonry valve pit of size 90x90X90 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces complete all as specified. |
| 42 | Brick masonry valve pit of size 75X75X75 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces complete all as specified. |
| 43 | Supply, install, test and commisioning of water circulation pump, Horizontal split casing end suction pump 415 V, 50 Hz, 1450 RPM suitable for discharge capacity not less than16LPS @ 30 Mtr head having pump efficiency 65-75%, and suitable for smooth pumping with prime mover motor IE2 TEFC Two Poles, Continuous Opeartion F class insulation, protection IP-55, Operating voltage 380V-440 / 3 phase, 50HZ . Pump with pre filter in Cast iron with matching connection size Impeller & Motor shaft in Stainless steel AISI 304 with Mechanical seal in Graphite/Ceramic,The pump shall be of cast iron body, bronze impellar, with mechanical seals, TEFC squirrel cage IE-2 induction motor, M.S. Fabricated base plate, mounting channel frame, accessories and fitting i.e. pressure gauges, Air release valve, drains, coupling, coupling guard, PCC foundation, vibration isolation arrangement complete all as specified in the particular specification. |
| 44 | Supply, install commissioning and testing LT panel board (indoor type) cubical type of size 0.90X0.90X0.45 meter made out of CRCA sheet 3.15 mm thick dust and vermin proof and angle iron of size 50 x 50 x5 mm, pedestal frame grouted in PCC (1:2:4) type B-1, 20mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should be covered from all sides with front and back lockable door and hinges complete with aluminium busbar coloured insulated with heat shrinkable sleeves of capacity 150 Amps , TPN, three phase, 04 wire (In separate chamber) including painting with two coats synthetic enamelled paint over a coat of red oxide primer and consisting of the following :-( LT panel for P/H bldg ) INCOMING: (a) MCCB 4 Pole 63 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) - 01 No OUTGOING: (b) MCCB 4 Pole 40 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) - 02 Nos (c) Single phase preventor -02 Nos (d) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No (e) MCB SPN 10 Amp C curve, 10 KA capacity - 01 No (f) Star-delta starter 15 HP - 02 Nos (g) Indicator lamp (R,Y,B) (h) Digital Ammeter 0-100A with suitable ratio of CTs – 01 No. (i) Digital Volt meter 0-500 Volts – 01 No. |
| 45 | Material and labour for Construction of valve pit of brick masonary from the top of surface including cover of MS sheet 3.15mm thick and angle iron 30mmx30mmx4mm with hinges and locking arrangement including painting with two coats of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4, plastering in cement morter 1:4, foundation concrete 1:3:6 including necessary earthwork complete all as specified and directed. of size 2500 x 2500 x 5000 mm. (internal dimension) |
| 46 | Supply, installation, commissioning and testing of diesel engine driven, water cooled,electrical start silent Generating Set 40 KVA capacity, liquid cooled, turbo charged with after cooler, developing 56 bhp approx @ 1500 RPM, 4 valve per cylinder, electric start, compressor ignition, 4 stroke engine designed to run continuously at 1500 RPM confirming to time rating ISO-3046/BS5514 standard with an overload capacity of 10% for one hour in every 12 hrs of operation, diesel forms to present CPCB norms complete including common base plate, floor mounted , factory assembled complete fitted in and including acoustic enclosure (sound proof canopy of suitable capacity or size) alongwith standard manual panel approved by National Physical laboratory with inbuilt standard panel, in built fuel tank suitable capacity for 12 hrs running at full load continues running, includind PCC foundation / platform for generating set as per manufacturer's instructions / conforming with drawing complete as specified and comprising with and including the following :- |
| 47 | a) Flywheel with starter ring for generating set.b) Air filter.c) Lub oil cooler assembly with accessories.d) Exhaust air manifold.e) Expansion bellow.f) Fuel filter.g) Lube oil filter.h) Exhaust gas turbo charger with after cooler.i) Radiator with pusher type fan, with fanguard, coolant pump. j) 12 V electrical starting system with starter motor and battery charging alternator.k) In-line monoblock fuel injection pump with electronic governing & Iscchoronuscapability.l) Bore x stroke - Suitable Size. Engine cubic capacity - Suitable capacity.n) Engine mounting supports.o) Engine control panel - microprocessor based controller model.p) Engine safeties, alarms and trips.q) K cool super plus corrosion inhibitor coolant for cooling.r) Engine operator/ maintenance & spare parts CD.s) Engine warranty certificate and test cerificate. |
| 48 | (A) AlternatorAlternator rated at 40 KVA, 415 volts, 3 phase, 4 wire, 0.8 p.f. (lag), 50 Hz, 1500 RPM, in accordance with IS 4722 as per following specifcations : i) Type : Salient poles, single bearing, Brushless type, suitable for direct coupling engine. ii) Rating : Guaranteed to deliver reqiured output at the ambient temperature conditions of Hisar. Suitable for an over load of 10 % for 1 hour in every 12 hour of operation. iii) Voltage regulation : Provided with fast response thyristor type electronic automatic voltage regulator, which holds output voltage within desired limits.(+/-1%). iv) Excitation : Self excited self regulated. v) Alternator loading : Suitable for taking rated load immediately after machine reaches rated voltage and speed. vi) Equipped with AREP ( Auxilary regulation Exiting Principle) winding to give performance equivalent to PMG as standard scope of supply. vii) Vibration: Suitable for direct coupling with Engine and mounted on common fabricated sheet metal base frame.viii) Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. ix) Cooling: Air Cooled type with radial fan mounted on Rotor for water cooled Radiator. x) Winding and Insulation: Insulation class H as defined in IS – 4722. |
| 49 | (B) Diesel Engine Adequate capacity of diesel Engine of suitable BHP to give out put of 40 KVA by alternator , liquid cooled to drive independently above alternator and after considering duration as per site conditions generating and reducing power consumed by accessories. Directly coupled through flexible coupling multi-cylinder , multi stroke direct injection , cold starting 1500 RPM as per with an overload capacity of 10% for one hour inany 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation.Note : Paid voucher for the complete DG set shall be from the same OEM only. |
| 50 | (C) ESSENTIAL ACCESSORIESFollowing set of essential accessories are supplied with each DG set:-i) One No. MS Base Frame suitable for mounting of the offered engine and alternator.ii) One No. fuel tank of standard capacity sufficient for 12 Hrs running complete fuel gauge, inlet/outlet connections, drains plug,etc.iii) 12, 88 Ah Volts DC Battery of suitable capacity with leads.iv) 1 Set of AVM Pads fitted in Base Frame.v) All above accessories are housed in acoustic enclosure |
| 51 | (D) CONTROL PANEL The Control Panel body shall be fabricated out of 16 SWG MS sheet. Panel shall be suitable for inside Canopy mounting, indoor installation, Copper Control cable of suitable size and required length shall be used. Cables are ferruled for proper maintenance/checking/wiring of panel. Detachable cable gland plates are provided. The panel shall be integrable with AMF,synchronization and communication configurations. Control panel must have following monitoring features:phase voltage,phase currents,KVA,KW,KWH,KVar,Power Factor,Lube Oil Pressure,Engine temp, RPM, Run Hrs, No of Starts , Fuel Level,auto/manual stop, Battery charge condition,common alarm, hooter output, AMF Features with ATS Please Enable Macros to View BoQ information |
| 52 | (D) CONTROL PANEL The Control Panel body shall be fabricated out of 16 SWG MS sheet. Panel shall be suitable for inside Canopy mounting, indoor installation, Copper Control cable of suitable size and required length shall be used. Cables are ferruled for proper maintenance/checking/wiring of panel. Detachable cable gland plates are provided. The panel shall be integrable with AMF,synchronization and communication configurations. Control panel must have following monitoring features:phase voltage,phase currents,KVA,KW,KWH,KVar,Power Factor,Lube Oil Pressure,Engine temp, RPM, Run Hrs, No of Starts , Fuel Level,auto/manual stop, Battery charge condition,common alarm, hooter output, AMF Features with ATS Please Enable Macros to View BoQ information |