| 1 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, in hard/dense soil, complete all as specified and directed. |
| 2 | Removing excavated material and deposited out of MD Land upto 15 km, complete all as specified and directed by Engr in Charge. |
| 3 | Material and labour for cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) in foundation filling and mass concrete, complete all as specified and directed. |
| 4 | S&F Mild steel work medium weight of any dia of pipe including fabrication and errection complete in tublar trusses/purline and rafter including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161-2007 grade St-240 complete including fixing to wooden rafter, complete all as specified and directed. |
| 5 | M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified and directed. |
| 6 | Material and labour for two coats of synthetic enamel paint over a coat of red oxide primer incl preparation of new steel surface over 10 cm width or girth, complete all as specified and directed. |
| 7 | S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws, complete all as specified and directed by Engr-in-charge. |
| 8 | S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-charge. |
| 9 | M & L for Aluminium composite panel sheet 3mm thick PVCF Glossy or matt finished of approved make fixed with necessary aluminium tube of size 25mm x 38mm x 1.2 to 1.5 mm thick with required cilicon & screw as in ceiling/coloumns and in vertical/horizontal surface, complete all as specified and directed. |
| 10 | S&F for PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 75 mm bore, complete all as specified and directed. |
| 11 | S&F for PVC (SWR) bends any radius, 75 mm bore, complete all as specified and directed. |
| 12 | Material and Labour for Granite stone best quality (of any type) tiles 18 to 20 mm thick machine cut, beded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed. |
| 13 | Dismantling, floor hearth or wall tiling inclduing cement mortar bedding and removing rubbish, complete all as specified and directed. |
| 14 | Material and Labour for first and premium quality of vetrified coloured digital tiles 1200 mm x 600 mm x 8 to 10 mm thick, in skirting, dados, risers to steps, etc se and jointed in neat cement slurry, and pointed in coloured cement to match tiles over and including 10mm thick rendering or backing layer in cement mortar 1:4, complete all as specified and directed. |
| 15 | Material and Labour for first and premium quality of vetrified coloured digital tiles size 600 x 1200 x 8 to 10 mm thick polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shed of tiles over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed. |
| 16 | M&L for cement concrete 1:4:8 type D-2, 75mm thick as in sub base, complete all as specified and directed. |
| 17 | Supply and fixing 10 to 12 mm thick toughned glass as in door shutters, plateform partition including necessary cutting to shape, drilling holes as reqd, jointing cleats, glazing clips, ruber neoprene packing, Stainless steel fittings such as handle 2 nos, 100mm hinge 3 nos, lock including keys 1 set, Stainless steel snap beading & screws, complete all as specified and directed. |
| 18 | M&L for Brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 19 | Material and labour for 15-20 mm thick ready mix plaster in multy layer with liquid water proofing compound on fair faces of brick wall or concrete surfaces, finished even and fair, including use of scaffolding, complete all as specified and directed by Engr-in-Charge. |
| 20 | Material and Labour for preparation of old/ newly plastered surface of wall and applying two coats of oil emulsion distemper over a coat alkali resistant primer coat through authorised applicators of paint manufacturers only of approved shade, complete all as specified and directed. Make: \\"Tractor Uno\\" of Asian Paints / \\"Jadoo\\"of Berger Paints / Nerolac Beauty of Nerolac paints as approved by GE. |
| 21 | Material and Labour for preparing old /newly plastered surfaces of walls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife and top coat of Apex Ultima protek, Make : Asian Paints) over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings, complete all as specified and directed. |
| 22 | M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in PVC casing & caping heavy duty surface wiring, MS sheet metal switch/Terminal box 1.2 mm thick and modular white cover with frame and modular metel box flush box, brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface, complete all as specified and directed. |
| 23 | All as per item No. 22 above but for Same board 5 Amps switch socket out let using 1.5 Sqmm wire with 1.5 Sqmm wire for earth continuity conductor and modular white cover with frame and modular metel box flush box, complete all as specified and directed. |
| 24 | All as per item No. 22 above but for independent 5 Amps switch socket out let using 1.5 Sqmm wire with 1.5 Sqmm wire for earth continuity conductor with modular white cover with frame and modular metel box flush box, complete all as specified and directed. |
| 25 | All as per item No. 22 above but for 5/15 Amps switch point socket out let using 4 Sqmm wire with 4 Sqmm wire for earth continuity conductor on independent board with modular white cover with frame and modular metel box flush box, complete all as specified and directed. |
| 26 | Supply and fixing including connection of Modular switch 1 way 6A, 1 module one way, complete all as specified and directed. |
| 27 | Supply and fixing including connection of Modular Socket outlet 3 pin, 6A, flush type, complete all as specified and directed. |
| 28 | Supply and fixing including connection of Modular Switch socket outlet 3 pin 6 amp flush type, complete all as specified and directed. |
| 29 | Supply and fixing including connection of Switch socket outlet multipurpose 3 pin, 16 amp and one pin, 6 amp controlled by one switch, complete all as specified and directed. |
| 30 | Supply and fixing of ceilings rose of PVC polycarbonate isolated body three terminals, complete all as specified and directed. |
| 31 | Supply and fixing of Fan step regulator, 120W - 2 module, modular type, complete all as specified and directed. |
| 32 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 2 x 2.5 Sqmm and earth continuity conductor of size 1 x2.5 Sqmm to be drawn in PVC casing caping, complete all as specified and directed. |
| 33 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 2 x 4 Sqmm and earth continuity conductor of size 1 x4 Sqmm to be drawnin PVC casing caping, complete all as specified and directed. |
| 34 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 4 x 6 Sqmm and earth continuity conductor of size 1 x6 Sqmm to be drawn in PVC casing caping, complete all as specified and directed. |
| 35 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 4 x10 sqmm earth wire and earth continuity conductor of size 1 x 10 Sqmm to be drawn in PVC casing caping, complete all as specified and directed. |
| 36 | Supply and fix wall fan, heavy duty 400 mm sweep, 1400 RPM and connecting up including provision of copper and flexible 3 core of size 0.6 sqmm and PVC connector block, necessary messonery work required for hole of suitable size, complete all as specified and directed. |
| 37 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC), complete all as specified and directed. |
| 38 | Supply and fixing LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 39 | Supply & fix LED down lighter 2'x2', 35 W, complete all as specified and directed. |
| 40 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers and connecting up including provision of copper and flexible 3 core of size 0.5 sqmm and PVC connector block, necessary messonery work required for hole of suitable size, complete all as specified and directed. |
| 41 | Supply and fixing single pole and neutral sheet metal enclosure box including metallic two pin Plug and socket with 20 Amps MCB (SPN) 'C' series including connection with two runs of 4.0 sqmm.copper cable with one run 4.0 sqmm copper cable for earth continuity, complete all as specified and directed. |
| 42 | Supply and fixing of MCB DB double door, made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and din rail TPN 4 way with 200 Amps rated bus bar 240 Volts, complete all as specified and directed. |
| 43 | Supply and fixing of MCB DB double door, made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and din rail SPN 8 way with 200 Amps rated bus bar 240 Volts, complete all as specified and directed. |
| 44 | S & F miniature circuit breaker (MCB) SPN of 40 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 45 | S & F miniature circuit breaker (MCB) SP of 40 to 63 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 46 | S & F miniature circuit breaker (MCB) SP of 10 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 47 | M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25m below normal ground level) connected to galvanized earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C-1, 50 mm thick precast RCC (1:2:4) type B-1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including galvanised strip of size 25 mm x 3 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a disance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 of SSR Pt-I, complete all as specified and directed. |
| 48 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drwan in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire mm dia galvanised iron strip, complete all as specified and directed. |
| 49 | Supply and fix MCCB FP, 415 Volts, 100 Amps, 25 kA rupturing capacity 415 Volts, complete all as specified and directed. |
| 50 | S & F for Off load change over switch 100 amps, 4 pole, 415 Volts, 50 HZ with enclosure and connecting cable with suitable lugs/thimbles, fixed on wall with suitable nut, bolt etc, complete all as specified and directed. |
| 51 | Material & Labour for Sub main wiring with two run of 6 sqmm stranded copper conductor PVC unseathed FRLSH wire along with 6 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduite of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB, complete all as specified and directed.Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduite shall be measured as one length. |
| 52 | Supply, lay in trenches, floors, fix on wall/pole, passing through pipes etc., LT UG cable, 1100 volts grade, PVC/ XLPE insulated, with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs etc, of size 70 Sqmm 3.5core, confirming to IS specifications, complete all as specified and directed. |
| 53 | Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line and getting out, complete all as specified and directed. |
| 54 | Returning & filling including spreading, leveling watering and well ramming in layers n.exc 25 cm thick in any type of soil, complete all as specified and directed. |
| 55 | Removal of excavated soil to a distance n. exc 50 m above the starting point, complete all as specified and directed. |
| 56 | M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable, complete all as specified and directed. |
| 57 | M&L for local sand coushioning with dry and clean over and under the cable for protection of cable, 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building, complete all as specified and directed. |
| 58 | Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall, floor or roof etc, complete all as specified and directed. |
| 59 | Supply and fixing recess mounted low glare luminaire 36 watt 2 x 2 complete with all accessories with slim panel with super bright LED's & highly efficient light-smoothing optics to deliver superior illumination and energy savings, complete all as specified and directed. |
| 60 | Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.50 m below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab 30 cm x 30 cm x 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. Please Enable Macros to View BoQ information |