| 1 | Labour for Quarterly Maintenance contract for Daikin Chiller Model No- PFS2451DBRY of 3 x 220 TR capacity by OEM with following conditions. 1. 01 no of quarterly maintenance services & All breakdown calls. 2. inspecting entire system for any unusual condition such as noise, vibration etc. 3. check operating presssure and temperatures to ensure proper operating conditions, Evapouaror and condenser, chilled water flow, pressure drop 3. checking the entire system. 4. The Items if required will be measured & paid separately under different Items . The contractor should produce MOU with Daikin Company. |
| 2 | NOTES:(i) The contractor should produce MOU with Dakin Company. It is mandatory to upload the scanned copy of MOU (between OEM i,e M/S Daikin and contractor) along with all essential documents during quoting of bid and eligible for qualifying criteria(ii) During break down of plant, Technician from OEM have to attend the plant within 24 hrs, failing which penalty of Rs 200/- per hour per day be imposed on contractor. |
| 3 | Supply only in replacement of Old lube oil of Screw compressor, flushing and replacement with New Lube oil all as per specification of OEM standard (RL- 68H) including testing complete to the entire satisfaction all as specified and directed. |
| 4 | Supply only in replacement of unserviceable Drier Core as per existing site complete all as specified and directed. |
| 5 | Supply only in replacement of unserviceable Filter Drier all as per existing site complete all as specified and directed. |
| 6 | Supply only in replacement of old temperature sensors in the incoming/outgoing water pipeline of the chiller unit all as per existing site complete to the entire satisfaction all as specified and directed. |
| 7 | Supply only in replacement of old pressure transducers on the chiller unit all as per existing site and specifications complete to the entire satisfaction all as specified and directed. |
| 8 | Supply only in replacement of old driver for Expansion valve all as per existing site and specifications complete to the entire satisfaction all as specified and directed. |
| 9 | Supply only in replacement of old unserviseable Expansion valve all as per existing site and specifications complete to the entire satisfaction all as specified and directed. |
| 10 | Supply only in replacement of old unserviseable oil level switch on the chiller unit all as per existing site and specifications complete to the entire satisfaction all as specified and directed.(Labour shall be included in item No 1) |
| 11 | Supply and charging of Gas Vacuum the system and after maintaining vacuum for 24 hours supply and charge refrigerant gas R-134A complete all as specified.(3x220TR AC plant) and directed. |
| 12 | Labour for Quarterly Maintenance contract for BlueStar's Chiller Model No- XWCS4052AR2 of 3 x 50 TR capacity by OEM with following conditions. 1. 01 no of quarterly maintenance services & All breakdown calls. 2. inspecting entire system for any unusual condition such as noise, vibration etc. 3. check operating presssure and temperatures to ensure proper operating conditions, Evapouaror and condenser, chilled water flow, pressure drop 3. checking the entire system. 4. The Items if required will be measured & paid separately under different Items . The contractor should produce MOU with Daikin Company. |
| 13 | NOTES:(i) The contractor should produce MOU with Blue Star's company. It is mandatory to upload the scanned copy of MOU (between OEM i,e M/S Blue Star's and contractor) along with all essential documents during quoting of bid and eligible for qualifying criteria(ii) During break down of plant, Technician from OEM have to attend the plant within 24 hrs, failing which penalty of Rs 200/- per hour per day be imposed on contractor. |
| 14 | Supply only in replacement of unserviceable Drier Core as per existing site complete all as specified and directed. |
| 15 | Supply only in replacement of unserviceable Filter Drier all as per existing site complete all as specified and directed. |
| 16 | Supply only in replacement of old temperature sensors in the incoming/outgoing water pipeline of the chiller unit all as per existing site complete to the entire satisfaction all as specified and directed. |
| 17 | Supply only in replacement of old pressure transducers on the chiller unit all as per existing site and specifications complete to the entire satisfaction all as specified and directed. |
| 18 | Supply only in replacement of old driver for Expansion valve all as per existing site and specifications complete to the entire satisfaction all as specified and directed. |
| 19 | Supply only in replacement of old unserviseable Expansion valve all as per existing site and specifications complete to the entire satisfaction all as specified and directed. |
| 20 | Supply and fix in repair scroll type sealed compressor of capacity 12.5/13TR with all accessories base ,mounting accessories liquid line and discharge line valves, safety valve including refrigerant charging and oil charging all as per OEM's specifications, including testing for satisfactory cooling effect and commissioning, complete all as specified and directed . Note:- Old unserviceable compressor shall be diposited to AGE E/M store yard and receipt voucher obtained. |
| 21 | Supply and charging of Gas Vacuum the system and after maintaining vacuum for 24 hours supply and charge refrigerant gas 407 C complete all as specified.(3x50TR AC plant) complete all as specified and directed. |
| 22 | M&L for descealing of condeser alongwith connected pipe line system of capacity 3x220 TR as per existing make and model including opening of condenser cover of both sides including disconnecting of water pipe line for inlet and outlet of the condenser of each plant. Removing scale/sludge precipitated in the copper tube by push and pull method with iron rod connected with steel wire brush of suitable size as per condenser copper tube size at the entire length of condenser that scraping down the sludge precipitated in side the tube. Closing both side of condenser and circulating the descaling soulation in all tube of plant through the circulating pump and allows holding it for 30 minutes for chemical reaction. Opening the condenser both sides and clean with iron road connected with nylon brush of suitable size as per condenser copper tube size at the entire length of condenser ensure that descaling process has been complete then closing the condenser at both end and circulating clean water in all the tube of condenser and drain out the process will be continue till the satisfaction then fixing new gasket for both ends compressor tighten with new nut end bolt complete all as specified and directed |
| 23 | Ditto as in Item No 6 above but for condeser of capacity each 12.5 TR and as directed by by Engineer in charge.(Fixed 4 Nos of 12.5 capacity in 50TR plant) Each condensor of 12.5 capacity considered as one Job.. |
| 24 | M&L for complete servicing of condenser/chiller centrifugal pumpset of 50LPS and 30HP motor by engaging sufficient man power and suiatble T&P to ensure safety of pump-motor as well as working persons including disconnection suction and discharge water lines and removing of electric connection, dismantling the pumpset from MS Foundation including Greasing, Bearing replacement, Alignment of pump and refit the same complete all as specified and directed for (3x220TR AC plant) the following capacities:- |
| 25 | NOTES:(i) The rate considered is inclusive of tools and plants required for carrying out the repairs.(ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. |
| 26 | Supply only spares for Centrifugal Pumpset 50 LPS, Capacity 30 HP to the following items:- |
| 27 | Bearing Cast Iron Drive end / Non Drive end |
| 28 | Bearing Housing |
| 29 | Shaft sleeve Cast Iron drive end |
| 30 | Round lock nut |
| 31 | Seal Set |
| 32 | Set of keys |
| 33 | Pump Coupling set suitable for 30 HP condenser/chiller pump (cast iron made min 150mm dia with 04 Nos of nut, bolts and washer) complete all as specified and directed. |
| 34 | NBR solid spider type jaw coupling as per existing site complete all as specified and directed. |
| 35 | M&L for complete servicing of condenser/chiller centrifugal pumpset of 20LPS and 7.5HP motor by engaging sufficient man power and suiatble T&P to ensure safety of pump-motor as well as working persons including disconnection suction and discharge water lines and removing of electric connection, dismantling the pumpset from MS Foundation including Greasing, Bearing replacement, Alignment of pump and refit the same complete all as specified and directed. |
| 36 | NOTES:(i) The rate considered is inclusive of tools and plants required for carrying out the repairs.(ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. |
| 37 | Supply only spares for Centrifugal Pumpset 20 LPS, Capacity 7.5 HP complete all as specified and directed |
| 38 | Bearing Cast Iron Drive end / Non Drive end |
| 39 | Bearing Housing |
| 40 | Shaft sleeve Cast Iron drive end |
| 41 | Round lock nut |
| 42 | Seal Set (Make : Leak-Proof) |
| 43 | Set of keys |
| 44 | Pump Coupling set suitable for 7.5 HP condenser/chiller pump (cast iron made min 150mm dia with 04 Nos of nut, bolts and washer) complete all as specified and directed. |
| 45 | NBR solid spider type jaw coupling as per existing site complete all as specified and directed. |
| 46 | M&L for rewinding of Unserviceable chiller/condeser motor of Cap-30 HP, type and make as per site including disconnecting unserviceable burn out winding completely, insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, testing and commissioning complete to the entire satisfaction complete all as specified and directed. |
| 47 | All as per Sr item No 12 here-in-above but for the motor of Capacity 25 HP |
| 48 | All as per Sr item No 12 here-in-above but for the motor of Capacity 7.5 HP |
| 49 | M&L for complete servicing to FRP based Cooling Tower of Capacity 220 TR by dismanteling PVC Honeycomb Fills, Coupling cooling Fan, sprinkellers, draining out of water, removing Algae, silt, cleaning complete cooling tower body by removing scale, dust, dirt, cleaning existing external surface and servicing of mechanical componenets and welding to cross members and frame bracing components incl repair of Bottom Tray (FRP Plate) of cooling tower with suitable water chemical (FRP resin), including replacement of gear box bearings, greasing and overhauling of the complete transmission system of cooling tower and re-assembling all the dismantled componenets to its original position, testing complete to the entire satisfaction complete all as specified and directed.Note:- Spare parts shall be measured and paid for separately under respective item. |
| 50 | All as per Sr item No 15 here-in-above but for the Cooling Tower of Capacity 50 TR |
| 51 | S&F in repair/replacement of PVC Honeycomb fills for 220TR cooling tower incl dismantling/removing of old PVC fills as per site requirement (600mmx300mmx150mm) complete all as specified and directed |
| 52 | S&F in repair/replacement of PVC Honeycomb fills for 50TR cooling tower incl dismantling/removing of old PVC fills as per site requirement (600mmx300mmx150mm) complete all as specified and directed |
| 53 | S&F in repair/replacement of Cooling Tower sprinkler system alongwith PVC connection pipes 50mm for cooling tower of capacity 220 TR, complete all as specified and as per directions complete all as specified and directed |
| 54 | S&F in repair/replacement of Cooling Tower sprinkler system alongwith PVC connection pipes 40mm for cooling tower of capacity 50 TR, complete all as specified and as per directions complete all as specified and directed. |
| 55 | M&L for rewinding of Unserviceable cooling tower motor of Cap-7.5 HP, type and make as per site including disconnecting unserviceable burn out winding completely, insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, testing and commissioning complete to the entire satisfaction complete all as specified and directed. |
| 56 | M&L for complete servicing to AHUs of Capacity 5100 CFM to 9000 CFM complete with various accessories i.e. blower with casing, Chiller water coil, Hot water coil, pre filter & fine filter frame, drive motor, humidification kit, motorised control valves, control panel including descaling of chilled/hot water coils, Greasing, Lubricating of moving parts and Repair/Replacement of bush, thrust plate, gland packing, driver pully, driver shaft and re-assembling all the dismantled componenets to its original position, testing complete to the entire satisfaction complete all as specified and directed. Note :- (i) AHU chilled water coils using chemical with brass brush in-order to remove all type of sledge/dust precipitatated on the coil without any damage to the copper coil then wash the cooling with fresh water and air blower upto the satisfactory of Engr-in-Charge. (ii) Iron body of the AHU inside and outside shall be scrap down and rub out with sand paper then apply one coat primer over a coat of synthetic enameld paint including part of duct portion in the AHU shall be completed upto the satisfactory complete all as specified and directed. |
| 57 | Material and labour in replacement High flow HEPA filter (high flow) with aluminium frame, box type a with flange of size 610x610x305mm, complete all as specified and directed. |
| 58 | Material and labour in replacement High flow HEPA (low flow ) filter with aluminium frame, box type a with flange of size 610x610x305mm, complete all as specified and directed. |
| 59 | Material and labour in replacement High flow HEPA filter (high flow) with aluminium frame, box type a with flange of size 610x305x305mm, complete all as specified and directed. |
| 60 | Material and labour in replacement High flow HEPA filter (low flow ) with aluminium frame, box type a with flange of size 610x305x305mm,complete all as specified and directed. |
| 61 | Material and labour in replacement PRE filter 10 micron A layer of now woven media is stitched along with layer of GI wire mesh on the downstream side to obtain required filtration and efficiency. The pleats are separated by spacers for maximum air flow of size 610x610x50mm complete all as specified and directed. |
| 62 | Material and labour in replacement PRE filter 10 micron A layer of now woven media is stitched along with layer of GI wire mesh on the downstream side to obtain required filtration and efficiency. The pleats are separated by spacers for maximum air flow of size 610x305x50mm complete all as specified and directed. |
| 63 | Material and labour in replacement PRE filter 10 micron A layer of now woven media to obtain required filtration and efficiency. The pleats are separated by spacers for maximum air flow of size 500x500x50mm complete all as specified and directed. |
| 64 | Material and labour in replacement PRE filter 10 micron A layer of now woven media to obtain required filtration and efficiency. The pleats are separated by spacers for maximum air flow of size 500x300x50mm complete all as specified and directed. |
| 65 | Material and labour in replacement PRE filter 10 micron A layer of now woven media to obtain required filtration and efficiency. The pleats are separated by spacers for maximum air flow of size 300x300x50mm complete all as specified and directed. |
| 66 | Supply & fixing in replacement strip heater 3.0 kw complete all as specified and directed. |
| 67 | Supply & fixing in replacement strip heater 2.0 kw complete all as specified and directed. |
| 68 | Supply & fixing in replacement strip heater 1.5 kw complete all as specified and directed. |
| 69 | S&F in repair of AHU motor suitable for AC plants/Dehumidifier unit/Air washer of motor capacity 3HP by dismantling it from weather making unit of AHU, replacement of Bushes, bearings by opening nuts bolts and removing electrical connections of the motor, replacement of stator and rotor assembly, winding of motor with Copper enameled wire of required thickness as existing, replacement and alignment of shaft, complete all as specified and as directed. |
| 70 | Ditto as in Item No 35 above but for motor of capacity 5HP. |
| 71 | Ditto as in Item No 35 above but for motor of capacity 10HP. |
| 72 | Ditto as in Item No 35 above but for motor of capacity 15HP. |
| 73 | Ditto as in Item No 35 above but for motor of capacity 25HP |
| 74 | Ditto as in Item No 35 above but for motor of capacity 30HP |
| 75 | Supply & fixing in replacement of V belt B Series as per site requirement complete all as specified and directed. |
| 76 | Supply & fixing in replacement of V belt A Series as per site requirement complete all as specified and directed. |
| 77 | Supply and fix of CI Butterfly Valve of 65mm dia, ISI Marked PN-1.6, having Nitrile/EPDM rubber lining, SS stem, CS/SS Disc, Lever operated, including all jointing material i.e. Nut, Bolt, washer, Packing material etc duly insualted with checking, Testing and commissioning to the entire satisfaction complete all as specified and directed. |
| 78 | Supply and fix of CI Butterfly Valve of 80mm dia, ISI Marked PN-1.6, having Nitrile/EPDM rubber lining, SS stem, CS/SS Disc, Lever operated, including all jointing material i.e. Nut, Bolt, washer, Packing material etc duly insualted with checking, Testing and commissioning to the entire satisfaction complete all as specified and directed. |
| 79 | Supply and fix of CI Butterfly Valve of 150mm dia, ISI Marked PN-1.6, having Nitrile/EPDM rubber lining, SS stem, CS/SS Disc, Lever operated, including all jointing material i.e. Nut, Bolt, washer, Packing material etc duly insualted with checking, Testing and commissioning to the entire satisfaction complete all as specified and directed. |
| 80 | Supply and fix of CI Butterfly Valve of 200mm dia, ISI Marked PN-1.6, having Nitrile/EPDM rubber lining, SS stem, CS/SS Disc, Lever operated, including all jointing material i.e. Nut, Bolt, washer, Packing material etc duly insualted with checking, Testing and commissioning to the entire satisfaction complete all as specified and directed. |
| 81 | Supply and fix of CI Balancing valve of 65mm dia, ISI Marked PN-1.6, having Nitrile/EPDM rubber lining, SS stem, CS/SS Disc, Lever operated, including all jointing material i.e. Nut, Bolt, washer, Packing material etc duly insualted with checking, Testing and commissioning to the entire satisfaction complete all as specified and directed. |
| 82 | M&L for replacement of power contactor 3 pole, type MNX-A1 with 2 NO + 2 NC Aux contracts, all as per existing site and specifications complete to the entire satisfaction all as specified and directed. |
| 83 | Supply and fixing in repacement of display unit of microcomputer of 220 TR water cooled screw chiller AC plant control panel with control card and motherboard as per OEM including preprogrammed software to control all parameter of Compressure and chiller unit complete all as specified and directed. |
| 84 | Supply and fixing in repacement of display unit of microcomputer of 50 TR water cooled screw chiller AC plant control panel with control card and motherboard as per OEM including preprogrammed software to control all parameter of Compressure and chiller unit complete all as specified and directed. |
| 85 | S & F LT cable of control cable of 1100 v,1.5 sqmm, 6 core copper condutor PVC insulated PVC Sheathed , round wire strip armoured for AHU's LT panel complete all as specified and directed. |
| 86 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- |
| 87 | (a) 120 Sqmm 3.5 core |
| 88 | (b) 70 Sqmm 3.5 core |
| 89 | (c) 50 Sqmm 3.5 core |
| 90 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft / loose soil getting out and levelling of bottom surface to required level complete all as specified and directed. |
| 91 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and directed. |
| 92 | Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and directed. |
| 93 | Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches complete all as specified and as directed. (Note :- Punning thickness shall be measured.) |
| 94 | M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as specified and directed. |
| 95 | S & F for laying galvanized steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 50mm bore complete all as specified and as directed. |
| 96 | Boring of holes under road, pavement, hard standing by trenchless technology using suitable tools and machinery for laying of pipe upto 150mm bore complete all as specified and as directed .Note :- GI pipe shall be measured and paid in concern Item |
| 97 | M&L for Cleaning of 5000 ltr Tank all as specified and as directed. |
| 98 | S&F in replacement of M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 65 mm as per sample existing icluding bending and welding work and testing complete this job complete all as specified and directed. |
| 99 | Supply and fixing in replacement of dgital Hygrometer complete all as specified and as directed. |
| 100 | S&F in repair/replacement of MCB TPN 32 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified and as directed. |
| 101 | S&F in repair/replacement of MCB TPN 63 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified and as directed. |
| 102 | S&F in repair on existing location including taking out of existing MCCBs thermal magnetic ,adjustable type of following capacity :- |
| 103 | (a) MCCB 415 volts 630 Amps 04 pole 50KA |
| 104 | (b) MCCB 415 volts 400 Amps 04 pole 36KA |
| 105 | (c) MCCB 415 volts 350 Amps 04 pole 36KA |
| 106 | (d) MCCB 415 volts 250 Amps 04 pole 36 KA |
| 107 | (e) MCCB 415 volts 200 Amps 04 pole 36 KA |
| 108 | (f) MCCB 415 volts 160 Amps 04 pole 36 KA |
| 109 | (g) MCCB 415 volts 100 Amps 03 pole 16 KA |
| 110 | (h) MCCB 415 volts 63 Amps 03 pole 16 KA |
| 111 | S&F in repair/replacement of volt meter (0-500A) digital squire flush type of size 96x96 mm, three phase, with inbuilt selector including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable one complete all as specified and as directed. |
| 112 | S&F in repair/replacement of Ammeter (0 - 200 A) digital squire flush type of size 96x96 mm, three phase CT operated CIR 5 amp, with inbuilt selector including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable one complete all as specified and as directed. |
| 113 | Taking out of defective /unserviceable /obsolete model indicator lamp from LT panel AC plant, supply and fix indicator lamp LED type of different colour of existing, 60 mm dia 30 volts complete all as specified and as directed. |
| 114 | M&L for single phase preventer model VSP 2, suitable to be fixed with FASD starter of any capacity for operation of the submerSI-ble pump motor, including taking out old U/S one complete all as specified and as directed. |
| 115 | S&F in repair/replacement of relay ML 1.5 415 volt VAC, 50 Hz, current rating:-10-16 Amp to be fixed with FASD starter for operation of the submerSI-ble pump motor, including taking out old U/S one complete all as specified and directed. |
| 116 | S&F in repair/replacement of Ammeter Selector Switch with OFF for CT, 10 A including taking out old U/S one, complete all as specified and as directed. |
| 117 | S&F in repair/replacement of Voltmeter Selector Switch with OFF for 10 A -01 No including taking out old U/S one, complete all as specified and as directed. |
| 118 | M&L for cutting and dismantling the existing winding of exhaust fan 450mm sweep with super enamelled copper winding wire of suitable gauge including varnishing lubricating, greasing oiling testing complete all as specified and directed. |
| 119 | S&F in repair/replacement of water Pressure indicating Gauge fitted in water circulation circuit Range-0 to 100/150 lbs/Sq in and 0 to 7/10.6 Kg/Sq Cm complete all as specified and as directed. |
| 120 | M&L for painting of AC plant as per existing colour including compressor, condenser, motor, chiller pump, AHU, cooling tower including base and all pipeline & connected valve Of AC plant of capacity 3X220TR plant complete all as specified and as directed. |
| 121 | M&L for painting of AC plant as per existing colour including compressor, condenser, motor, chiller pump, AHU, cooling tower including base and all pipeline & connected valve Of AC plant of capacity 3X50TR plant complete all as specified and as directed. |
| 122 | Detecting the fault of 3 x 220TR and 3 x 50TR capacity of AC Plants and any location by providing skilled Refrigerent Mechanic/Skelled Elect & helper with necessary safety and working equipment such as ,multimeter ,speedometer and other reqd tools and plants and rectified the defects on top priority basis/as and when reqd including testing, complete all as specified and directed. |
| 123 | M&L for replacement of damaged insulation of chilled/hot water pipeline upto 150 mm having thickness of thermo cole insulation 50 mm of density 16 Kg/Cum and 26 gauge Aluminium cladding complete suitable for above ground with all mounting arrangements like clamps with nut bolt etc, complete all as specified and as directed . |
| 124 | M & L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised strip 32X6mm by means of bolts, nuts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 15 mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of funnel pipe of 20 mm GI light grade pipe and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate. |
| 125 | S&F GI Strip 32x6mm fixed on wall or buried in ground or any other indicated situation complete all as specified and as directed. |
| 126 | NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |