| 1 | M&L for preparation of old decorated or previously treated wall surfaces, brooming down or steel wire brushing; scrapping down smoke soot moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of white/ Colour wash on walls complete all as specified and directed by Engineer-in-charge. |
| 2 | M&L for complete removal of existing treatment of old decorated or previously treated wall surfaces by scraping brooming down and applying two coat of white/Colour wash on walls complete all as specified and directed by Engineer-in-charge. |
| 3 | M&L for prepration of old decorated wall surfaces including cornices brooming down or steel wire brushing; scrapping down smoke soot moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coats of cement base paint of approved shade complete all as specified and directed. |
| 4 | M&L for complete removal of existing treatment of wall including cornices brooming down or steel wire brushing; scrapping down smoke soot moulds, moss and efflorescent salts and trading oil and greasy spots etc. by washing, rubbing down and stopping holes, and applying two coats of cement base paint of approved shade complete all as specified and directed. |
| 5 | M&L for preparation of old decorated plastered or unplastered surfaces of wall and applying one coats of oil bound distemper including preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds, moss,efflorancr salt , trading oil and greasy spot complete all as specified and directed. |
| 6 | M&L for preparation of old decorated plastered or unplastered surfaces of wall and applying two coats of oil bound distemper including preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds,filling gaps wth wall care putty, complete all as specified and directed. |
| 7 | M&L for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm height on existing surface |
| 8 | Cutting shrubs, wild growth/trees n exc 30cm girth and removing complete vegetation growth from walls incl taking out roots from roofs/brick work and making good the disturbed surface with PCC 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate including treating affected area with acid wash to check further growth of vegetation and disposing off the rubbish from site (MoD Land) from the above mentioned area complete all as specified and as directed. |
| 9 | S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls etc with MS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified. |
| 10 | S&F PVC (SWR) bends suitable for 75 mm external dia with or without access door complete all as specified |
| 11 | S&F PVC (SWR) junction single, (single T&Y) equal or unequal with or without access door confirming to IS: 14735, suitable for PVC soil waste discharge pipe of 75 mm dia Complete all as specified and as directed. |
| 12 | S&F PVC (SWR) pipes, 110 mm external dia, type-B, ISI marked (IS:13592) double socketed in any length with rubber ring joints, fixed to walls etc with ms clampsMS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified. |
| 13 | S&F PVC (SWR) bends suitable for 110 mm external dia with or without access door complete all as specified |
| 14 | S&F PVC (SWR) junction single, (single T&Y) equal or unequal with or without access door confirming to IS: 14735, suitable for PVC soil waste discharge pipe of 110 mm dia Complete all as specified and as directed. |
| 15 | Dismantling of old stone broken/cracked stone slabs in laid bedded and pointed in any morter complete all as specified and directed. |
| 16 | M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars,window-cills, cooking platform and like in cement morter (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete including 15 mm thick bedding layer in cement mortar 1:6 as in cooking platform complete all as specified and directed. |
| 17 | Taking down cement or cement plaster on brick walls/ceiling etc including raking out joints, hacking for key, scrubing down with water etc complete all as specified and directed. |
| 18 | M&L 15 mm thick Rendering in cement mortar 1:4 on faces of brick work or concrete external surfaces of wall finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge. |
| 19 | M&L for rendering 15mm thick Plaster on fair face of brick surface in cement mortar 1:4 mixed with PD proof 101 LW(+) of Dr fixit or equvalant integral WP admixer @200 ml/bag of Ready mix over two coats of super latex 302 of Dr fixit or equ. in the ratio 1:4: 7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 Kg of homogenious mixture per Sqm in two coats on brick work or concrete surfaces finished even and fair without using extra cement including taking down of cement plaster complete all as specified and directed. |
| 20 | M&L for preparation of new plastered surfaces of wall and applying two coat of cement based paint over a coat of cement primer all as specified. |
| 21 | M&L for preparation of old decorated or previously treated wall surfaces, brooming down or steel wire brushing; scrapping down smoke soot moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489;2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/10 sm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new/ old previously treated wall surfaces. |
| 22 | M&L for providing precast reinforced cement concrete jallies 45 mm thick including all mouldings type B-0 1:2:4 (12.5mm graded stone aggreagte) set in cement mortar 1:4 including taking down Old RCC Jallies complete all as specified. |
| 23 | M&L Welding in repairs n. exc 6mm thick metal and n. exc 2.5 cm in length all as specified and directed.. |
| 24 | Complete removal of old roof treatment incuding cement mortar ( except mudfushka , brick tile ) and removal of grass, small trees by picking sweeping , cleaning and washing down with water to remove dust etc incuding removing debries out side MOD land , complete all as specified and directed. |
| 25 | M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water brushing neat cement slurry with 3.0 kg/sqm and M&L for 15 mm thick cement plaster over the concrete / brick roof surfaces in cement mortar 1:4 mixed with liquid water proofing compound @ 200ml per bag WPC (liquid type) , surface finished even and smooth without using extra cement all as specified and directed.Note :- Water proofing additive shall be measured and paid separately. |
| 26 | M&L for applying a priming coat of @ 0.30 Kg / Sqm with Bituminous primer including prepration of surface , complete all as specified and directed . |
| 27 | M&L for applying evenly a tack coat of industrial hot blown grade bituminen 85/25 @ 1.2 Kg/Sqm including cleaning surfaces ,complete all as specified and directed. |
| 28 | M&L for water proofing treatment of roof with APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) shall be laid with 100mm side lap/end lap on primed surfaces as per manufacturers instruction , complete all as specified and directed. |
| 29 | M&L for applying a coat of heat resisting paint ( aluminium bitumen paint) over APP surface, complete all as specified and directed . |
| 30 | M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings including taking down of old plastered surface complete all as specified (Payment for providing grooves shall be made separately). |
| 31 | M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |