| 1 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge. |
| 2 | Rough excavation not exceeding 1.5m deep and getting out in soft / loose soil complete all as specified and as directed. |
| 3 | Material and labour for Rolling and consolidating formation surfaces in cutting by using power road roller of 8 to 12 ton capacity complete all as specified and as directed. |
| 4 | Material and labour for 150 mm thick Soling or sub base with broken boulders or quarried stones, interstics filled surfaces formed and rolled with power road roller of 8 to 12 ton capacity and consolidated to gradient and camber required complete all as specified and as directed. |
| 5 | Material and labour for laying and compacting 150mm thick (compacted thickness), Wet Mix Macadam(WMM), laid in two layers of 75mm each grading as per table 400-13 of MoRTH specifications for Road and Bridge works 2013, manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor pavor and rolling with vibratory roller of capacity 80KN-100KN static weight and consolidating to required gradient and camber complete all as specified and as directed.Note- The finished surface tolerances to be as per Table 900-1 of MoRTH specifications for Road and Bridge Works 2013. |
| 6 | Material and labour for Preparing unsurfaced WMM by brushing with wire brushes for removing caked mud etc. sweeping with brooms and cleaning the complete surfaces by using mechanical blower upto entire satisfaction of Engineer-In-Charge complete all as specified and as directed. |
| 7 | Material and labour for applying evenly a priming/ tack coat with bituminous primer @ 10 Kg per 10Sqm using paving bitumen grade VG-10 complete all as specified and as directed. |
| 8 | Material & Labour for laying Bituminous Premixed Semi Dense Asphaltic Concrete, 40 mm consolidated thickness, using paving bitumen of Grade VG – 30, with 5.5% of binder content by weight of total mix using Hot Mix Plant and Mechanical Paver finisher, rolled and compacted with power road roller of 8 to 12 ton capacity to required camber and gradient complete all as specified.Note: Minimum Bitumen content shall be 5.5% as specified here in above. Please note that if the actual quantity of bitumen to be incorporated on approval of Mix–Design is found more than the minimum bitumen content specified above, No price adjustment shall be made for actual bitumen content of Mix–Design. Bitumen shall be Paving Bitumen of Grade VG–30 and shall be procured by the contractor. Mix Design shall be approved by GE. |
| 9 | Material & Labour for Road Marking Strips, Lines, Dashes, Arrows, Letters etc of 2.5 mm thick [Reflective Type] of approved colour conforming to BS 3262-1989 on roads, pavements and the like not exceeding 10cm wide with Hot Thermo Plast material by fully automatic thermoplastic paint applicator machine, fitted with profile shoe, glass beads dispenser, propane tank heaters and profile shoe heater, driven by skilled operator on road surface complete as per MoRT & H specifications including cleaning the road surface of all dirt, scales, oil grease and foreign materials etc complete all as specified and as directed. |
| 10 | Supply and fixing of cat eye reflective type of metal body alloy of size 110mm x 120mm x 20mm with PAMA striplens reflector fixed with and including aluminium studs of suitable size as per manufactures instructions complete all as specified and directed. |
| 11 | Material and labour broken stone or boulders hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 12 | Material and labour for 75mm thick cement concrete 1:3:6 type C2 (40mm graded aggreded) as in sub base, finish the surface even and rough to receive topping layer complete all as specified and as directed. |
| 13 | Material and labour Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.(Note: Punned thickness shall be measured for payment purpose) |
| 14 | Material and labour for contineuos edging with 7.5cm thick PCC soild blocks (1:3:6) type C1 (Block size 300x200x75mm) laid on end vertically with width equal to the depth of blocks including embedding the blocks in ground and tamping the ground around the blocks and removal of surplus soil if any complete all as specified and as directed. |
| 15 | Material and labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 grade with grey cement and pigment complete all as specified and as directed |
| 16 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil etc complete all as specified and as directed. |
| 17 | Excavating over areas, exc 1.5 m but not exc 3.00m deep and getting out in soft/loose soil etc complete all as specified and as directed. |
| 18 | Excavating over areas, exc 3.0 m deep but not exceeding 4.5m deep and getting out in soft/loose soil etc complete all as specified and as directed. |
| 19 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed. |
| 20 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and exceeding 1.5m deep but not exceeding 3.0m deep in Soft / Loose soil complete all as specified and as directed. |
| 21 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and exceeding 3.0m deep but not exceeding 4.50m deep in Soft / Loose soil complete all as specified and as directed. |
| 22 | Returning, filling in including spreading and levelling watering and well remming in layeres n.exc. 25cm thick complete all as specified and directed. |
| 23 | Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 24 | Material and labour for Hand packing with Broken stone Broken or boulders of size 50mm to 20mm in 300mm thick at back of walls over arches etc. and raising (or lowering) to the required level as shown on drawing complete all as specified and directed. |
| 25 | Supply and laying 110mm bore PVC [SWR] pipes in single piece without joint as in retaining wall complete all as specified and as directed. |
| 26 | Material and labour for cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 27 | Material and labour for cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 28 | Material and labour for reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) for foundation and plinth beams etc complete all as specified and as directed.Note :- Note :-(i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE. |
| 29 | Material and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilasters and buttresses complete all as specified and as directed.Note :-(i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE. |
| 30 | Material and labour for reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) for beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.Note :- (i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE. |
| 31 | Material and labour for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, flat complete all as specified and as directed. |
| 32 | M & L for use and waste of formwork to faces of walls,retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter with rough finished surfaces of concrete flat complete all as specified and as directed. |
| 33 | Material and labour for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc with rough finished surfaces of concrete flat complete all as specified and as directed. |
| 34 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 35 | Material & Labour for rendering 15mm thick in cement mortar 1:4 including mixing with water proofing compound @ 2% weight of cement on brick masonry surface, finished even and smooth without using extra cement complete all as specified and as directed.Note: Water proofing compound will be measured and paid separately. |
| 36 | Material and labour for rendering 10 mm thick in CM 1:6 on fair faces of Brick masonry/Concrete surface finished even and smooth without using extra cement all as specified and directed. |
| 37 | Supply only integral water proofing compound (WPC) of best quality (ISI marked on packet) complete all as specified and as directed. |
| 38 | Material and labour for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 39 | Supply & Fixing Reinforcement using TMT steel bars 500D, 10mm dia and over, cut to length,bent to shape required,including cranking bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips qualsecuring with clips all as specified and directed. |
| 40 | Supply & Fixing Reinforcement using TMT Bars 500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 41 | Supply and fixing 5.5 mm thick sheet glass of ordinary quality of size not exceeding 0.50 Sq.m each pane for aluminium door/ window complete all as specified and as directed. |
| 42 | S&F powder coated Anodised aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, partitions and ventilators with or without rebates including joining cleats for fixing etc. complete all as specified and as directed. |
| 43 | S & F Anodised aluminium door 100mmx40mmx3.15mm side and top rail 150mmx40mm x3.15mm middle and bottom rails of side hung type without sash bars, aluminium sections including necessary jointing claets, glazing clips, rubber packing anodized aluminium snap beading, handles 2 Nos of 200mm in each door, hinges100mm long 03nos, aluminium door stopper, anodised aluminum snap beading screws etc. complete all as specified and as diretced. |
| 44 | Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified |
| 45 | S & F 100 mm, Brass Mortice Lock with 2 Levers, vertical type complete all as specified and as directed. |
| 46 | S & F Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed. |
| 47 | Supply and fixing steel work in tubular trusses i.e truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 etc complete all as specified and as directed . |
| 48 | Supply and fixing 12mm thick, Prelaminated Particle Board, Decorative Choice Lamination on Both Sides, Medium Density, Interior Grade with screw to steel /timber/PVC frame complete all as specified and as directed. |
| 49 | Material and labour for preparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 50 | Material and labour for preparation of new steel surfaces to receive painting over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 51 | Material & Labour for joint free non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding .11 sqm but not exc 0.18sqm in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 52 | Supply and fixing 300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts,of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 53 | Supply and fixing 25 mm dia Harrison Rails [Curtain Rails], mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 54 | Supply and fixing 6 mm thick,Plywood, grade BWR, type BB, fixed with screw to timber/steel/PVC frame work complete all as specified and as directed. |
| 55 | Supply and fixing of MCB DB TPN 4 ways, powder coated, double door, 415 Volts, including bus bar neutral link, earth bar and din rail, for fixing MCB of various rating complete all as specified and as directed. |
| 56 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 3.50 core laid in trenches/fixed to wall/under road/pipe as per IS 7098 (Part I) etc including cable glands, aluminium lugs complete all as specified and as directed.Note:-Excavation and earth work, brick protection, sand cushioning etc will be measured and paid separately |
| 57 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. |
| 58 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose) |
| 59 | Supply and laying 40 mm bore galvanised GI tubing, light grade with all fittings for passing of UG cables including complete all as specified and as directed. |
| 60 | Supply & fixing RCBOs for Earth leakage, overload & short circuit protection , four pole, 415 volts, 40/63 amps and sensitivity of 30mA, complete all as specified and as directed. |
| 61 | S & F of 9 Ltr capacity Water type fire extinguishe, conforming to IS 15683: 2006 with initial filling in brand new cylinder with powder coated finish, fitted in gun metal union, discharge hose, wall mounting bracket/floor trolley mounted assessories alongwith suitable signage, 2A-4A rating, 13-42 second discharge time and 6mtr jet range, operating at 15 bar pressure etc. complete all as specified and directed by the Engineer-in-charge.Notes: [i]Operating temperature: +5°C to +55°C[ii] Locking pin and wire seal should be provided to indicate that the extinguisher has not been use.[iii] Every Extinguisher should be supplied with an operating manual |
| 62 | Supply, installation, testing and commissioning of FM approved and UL listed microprocessor- based, true peer-to-peer networkable, Single loop Addressable Fire Alarm Control Panel (FCAP) with its own microcontroller memory, communication module, fire device loop interface cards for intelligent initiating and indicating devices and peer-to-peer networkable with other addressable fire alarm panels conforming to UL 2572 mass notification systems & NFPA 72, with required accessories complete all as specified and directed by the Engineer-in-Charge.The FACP shall meet the following specifications/functional requirements:-[i] The FACP shall have one isolated intelligent Signalling Line Circuits (SLCs) capable of connecting up to 99 detectors and 99 modules per SLC upto 200 detector and modules.[ii] The FACP shall have a degrade mode and the loops shall work in degrade mode in case of the CPU failure. |
| 63 | [iii] The FACP shall have 640 character LCD backlit display/ Touch Screen display, full QWETRY program keypad, LED indicators viz power, fire alarm. supervisory; system trouble; other event signals silenced point disabled, CPU failure, controls active; etc. membrane switch controls viz. acknowledge, signal silence, drill; system reset, lamp test, etc[iv] The FACP shall have four access levels, flash EPROM. 240 VAC power supply, automatic battery charger 24 V sealed lead acid batteries, sufficient for 24 hrs normal working and 30 min in alarm condition.[v] The FACP shall have manual sensitivity adjustment up to nine levels, built-in alarm, trouble, security and supervisory relays, history file with 4000-event capacity in non-volatile memory plus separate 1000-event alarm-only file, keypad operation. LCD unit to indicate fire / fault signal of individual unit in built printer to log all incoming data etc. Note: [i] The FACP shall be servicable by any system integrator & shall not have dependency on specific system integrator.[ii] The FACP shall have feature to \\"ADD\\", \\"EDIT\\" & \\"DELETE\\" field devices like detectors & modules without dependency on PC / Software / Special tool / dongle. |
| 64 | Supply, installation, testing and commissioning of Smoke Detectors Complying with and type certified to shall be conform to IS11360-1985 or BS 5446 Part- 1 1977 & Part-VII-1985 NFPA72 (UL/ULC/FM approved). Addressable type multisensor Smoke detector with base with self built intelligence as per IS complete with all accessories viz. base, base box, etc. to be installed below /above false ceiling, roof and concealed space, etc. complete all as specified and directed by the Engineer-in-charge. |
| 65 | Supply, installation, testing and commissioning of Detectors Complying with and type certified to (Heat Detectors shall be conform to IS-2175 or BS-5445(EN-54) part 5-1977 or NFPA72 (UL/ULC/FM approved). Addressable type multisensor Heat detector with base with self built intelligence as per IS complete with all accessories viz. base, base box, etc. to be installed below / above false ceiling. roof and concealed space, etc. complete all as specified and directed by the Engineer-in-charge. |
| 66 | Supply, installation, testing and commissioning of Aspirating Smoke Detectors Complying with and type certified to shall be conform to IS. Addressable type duct detector housing with sampling tube with base with self built intelligence as per IS complete with all accessories viz. base, base box, etc. to be installed at ceiling etc. complete all as specified and directed by the Engineer-in-charge. |
| 67 | Supply, installation, testing and commissioning of FM approved and UL listed surface/semi- flush mounted Dual Action Manual Pull Station \\"Push In & Pull Down\\" including an addressable interface for the intelligent FACP having built-in bicolour LED which is visible, flashing in normal operation and latching steady red in alarm condition, captive screw terminals wire-ready for easy connection to SLC loop complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply, installation, testing and commissioning of UL listed of Horn Strobe, wired as a primary notification appliance, flashing 75 cd at 1 Hz over the strobe's entire operating voltage range, xenon flash tube and associated lens / reflector system, built-in synchronization feature keeping strobes in sync for up to 30 minutes, horn producing audible annunciation of 75 dBA at 3 m distance complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply,installation, testing and commissioning of FM approved and UL listed addressable control module to provide FACP a circuit for notification appliances (e.g. Horns, Strobes, Horn Strobes, etc.) having built-in type identification, integral LED indicators, high noise immunity, SMES screws with clamping plates for wiring ease, direct-dial entry of address, etc. complete all as specified and directed by Engineer-in-Charge |
| 70 | Supply, installation, testing and commissioning of FM approved & UL listed remote power supply conforming to UL 864 & 1481 and NFPA 72 with integral battery charger capable of charging up to 18 Ah batteries to provide regulated and filtered 24 VDC power to notification appliance circuits, having power-supervision relay. fully regulated and filtered power output, AC trouble report selectable for immediate 2-hour delay, selectable earth fault detection, etc. complete all as specified and directed by the Engineer-in-Charge. |
| 71 | M & L for low smoke zero halogen (LSZH) flame retardant fire alarm cable of size 1.5 Sqmm of 2 core, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through in steel conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 °C to +70 °C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by the Engineer-in-Charge. |
| 72 | M & L for low smoke zero halogen (LSZH) flame retardant fire alarm cable of size 2.5 Sqmm of 2 core, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through in steel conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 °C to +70 °C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by the Engineer-in-Charge. |
| 73 | M & L for 45mm x 45mm PVC cable tray , inclusive of all connecting items, on wallboxes (junction / terminal), all tees, bends, elbows, fixing accessories such as, lock nuts, saddles, clamps, nuts, bolts etc, on wall / ceiling / truss for fire alarm / control cabling complete all as specified and directed by the Engineer-in-Charge. |
| 74 | M & L for 20 mm medium grade stove enamelled steel conduit pipe, conforming to IS, inclusive of boxes (junction / terminal), all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, clamps, nuts, bolts etc, on wall / ceiling / truss for fire alarm / control cabling complete all as specified and directed by the Engineer-in-Charge. |
| 75 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced to earthing lead of 32mm x 6mm galvanised mild steel strip by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion complete all as specified and as directed. Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
| 76 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on earthing set all as specified and as directed.Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. o the department. Please Enable Macros to View BoQ information |