| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Certain repair/replacement of unserviceable electrical fixtures, wiring and connected accessories of OTM and MD accn and Repair/maint of summer/winter appliances of CHNC under GE (Utilities) Udhampur Contract No: GE/U-24/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Taking down carefully alu./copper point wiring ,light fan socket, or power complete with fittings such as switches ceiling rose;holders; regulators, socket etc removing material to store for keeping in safe custody for reuse or disposal by credit and marking good to disturbed surfaces of walls floors etc, complete all as specified and directed by Engr-in-Charge. |
| 3 | M & L for concealed point wiring with FRLS grade PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC concealed conduit for fixing of switches, sockets,light, fan regulators etc, complete all as specified and directed by Engr-in-Charge. |
| 4 | One light/fan/bell point or one fan point controlled by one switch |
| 5 | One 3/5 pin socket outlet, 5 Amp independent |
| 6 | One socket outlet 5 Pin, 5 Amps, SP on same board. |
| 7 | One socket outlet 6 pin 6/16 Amps, indipendent with cables 2.5 sqmm size . |
| 8 | One light point point controlled by 2-way switches with cables 1.5 sqmm size. |
| 9 | M & L for wiring with FRLS grade PVC insulated unsheathed multistranded copper conductor cables in PVC casing caping of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm for fixing of switches, sockets,light, fan regulators etc for the following, complete all as specified and directed by Engr-in-Charge. |
| 10 | One light/fan/ /bell point or one fan point controlled by one switch |
| 11 | One 3/5 pin socket outlet, 5 Amp independent |
| 12 | One socket outlet 5 Pin, 5 Amps, SP on same board. |
| 13 | One socket outlet 6 pin 6/16 Amps, indipendent with cables 2.5 sqmm size . |
| 14 | S&F Piano type switch one way 6 Amps , 240 Volt, ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 15 | S&F Bell push,flush type, one way 6 Amps , 240 Volt ,ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F Switch Piano type single pole 15Amps one way 240 Volt, ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 17 | S&F Switch 6 amp, 2 way, 240 Volt ,ISI marked , complete all as specified and directed by Engr-in-Charge. |
| 18 | S&F socket outlet 2 in 1,3/5 pin piano type 5 Amp flush type ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 19 | S&F socket out let 6 /16 Amps 6 pin flush type , complete all as specified and directed by Engr-in-Charge. |
| 20 | S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F Lamp holde PVC type with back plate suitable for batten fittings, complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F of electronic step type regulator of capacity 240 volts flush type ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 23 | S& F Bell, AC, 230 volts, single pole, complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F in replacement LED lights fitting 1x 20W, 4 feet, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings, complete all as specified and directed by Engr-in-Charge. |
| 25 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings, complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F in replacement LED light fitting 1 x 9 W/ 1 x 10 W Bulk head luminaires complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings, complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F in replacement of sub main wiring with copper conductor cable (2 runs of cable) multistaranded 4.0Sqmm PVC ISI marked with all insulated unsheathed in and including PVC concealed conduit 25mm dia medium grade fittings including 4.0 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth dolly , complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F in replacement of sub main wiring with copper conductor cable (2 runs of cable) multistaranded 6.0 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC concealed conduit 25mm dia medium grade fittings including 6.0 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth dolly, complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L for earthing in repair complete with galvanized steel earth electrode 60cmX60cmx6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5m below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal, common salt, GI 4.0mm dia lead wire 20mm GI medium grade watering pipe 15mm bore light grade protection pipe 5 Mtr length with wire mesh and funnel PCC pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, angle iron frame and RCC cover and earth work complete all as shown in electrical plate No.3 of SSR -2009(Part-1). |
| 30 | S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces , complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F Sheet metal enclosure factory made for DBs single pole and neutral single door 240 volts 12 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing, and commissioning and making good of wall, surfaces , complete all as specified and directed by Engr-in-Charge. |
| 32 | S&F Sheet metal enclosure factory made for DBs single pole and neutral single door 240 volts 2 way , complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F RCBO double pole, 240 Volts , 50 Hz 10 Ka, 40 Amps, 30mA, complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F MCB single pole and neutral, 240 Volts , 50 Hz 10 Ka, 40 to Amps, 30mA , complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F MCB single pole 240 Volts , 6 to 20 Amps, complete all as specified and directed by Engr-in-Charge. |
| 36 | Taking down ceiling fan sealing cable end etc and shifting to store complete and rehanging the same after overhauling and with white synthetic enamel paint(two coat) with the help of spray gun and connecting with three core flexible copper conductor cable 0.75 sq mm, complete all as specified and directed by Engr-in-Charge. |
| 37 | Description all as per ser item No 26.00 here- in-before but for exhaust/cabin fans of any size/make |
| 38 | S& F in repair PVC connection 15 mm size with PTMT nuts of length 300 mm, complete all as specified and directed by Engr-in-Charge. |
| 39 | S& F in repair PVC Rectangular block for switches,socket, fan regulator 3 mm thick plastic laminated sheet cover of size 100mm x 100 mm and 50 mm deep, complete all as specified and directed by Engr-in-Charge. |
| 40 | Checking,servicing, oiling and greasing of fan of any size/type by using appropriate grade of oil /grease and replacing defective parts such as bush, bearing, split pin, rubber bush, hanging clamp and capacitor etc including cleaning complete all as specified and as directed by Engineer- in -Charge (Note|-Parts/components will be measured and paid seperately under their respective items) |
| 41 | Rewinding of celling fan 1200/1400mm sweep, AC, 230 volts single phase with super enamelled copper winding wire of appropriate size including packing, insulating material, soldering, varnishing, reassembling and testing as required, making functional, complete all as specified and directed by Engr-in-Charge. |
| 42 | Nuts, bolts and washers of appropriate size for hanging of celling fan, complete all as specified and directed by Engr-in-Charge. |
| 43 | Top / botton canopy of required size with tightening screws, complete all as specified and directed by Engr-in-Charge. |
| 44 | Bearing of celling fans for 1200/1400mm sweep suitable for different makes /type of fans, complete all as specified and directed by Engr-in-Charge. |
| 45 | Ball bearing suitable for exhaust fan 300mmsweep of different make, complete all as specified and directed by Engr-in-Charge. |
| 46 | Split pins of galvanished iron 1/8\\" dia, 2\\" length , complete all as specified and directed by Engr-in-Charge. |
| 47 | Rewinding of exhaust fan 300mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , reassembling , testing and making functional, complete all as specified and directed by Engr-in-Charge. |
| 48 | Condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD, complete all as specified and as directed by Engineer-in-Charge. |
| 49 | Description all as per ser item No 38.00 here-in-before but for 3.15 MFD. |
| 50 | Description all as per ser item No 38.00 here-in-before but 4 MFD for Exhaust Fan |
| 51 | Dismantling of geyser from its location, 25/35/50Ltrs capacity for checking, test and making leak proof by means of welding of tanks, replacement of parts, under item here in after and to make serviceable and re-assembling, including packing of glass wool properly, replacement of worn out nut, bolts, washers, screws as reqd, applying one coat of synthetic enamel paint including testing and re installation/ refixing, complete all as specified and as directed by Engineer-in-Charge. Note : New items provided shall be meaured and paid under relevent item of Sch. |
| 52 | Apparatus plate heavy duty, rubber gasket suitable for 25/35/50 Ltr of geyser, complete all as specified and as directed by Engineer-in-Charge. |
| 53 | Geyser element 1.5 KW, ISI Marked, complete all as specified. |
| 54 | Geyser element 2 KW, ISI Marked, complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Geyser thermostate switch ISI Marked, complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Geyser indicator lamp red colour for heating and green colour for cut off , complete all as specified and as directed by Engineer-in-Charge. |
| 57 | Geyser Non return valve 15mm dia pipe CP brass, ISI marked, complete all as specified and as directed by Engineer-in-Charge. |
| 58 | Geyser Pressure release valve ISI marked, complete all as specified and as directed by Engineer-in-Charge. |
| 59 | Descaling of gyser tanks of capacity 25/35/50 Ltrs by using suitable powder/ chemical, up to the satisfication of engineer in charge, complete all as specified and as directed by Engineer-in-Charge. |
| 60 | Suppy and fixing ceiling fans complete with blades, down rods,elecctonic regulators and accessories, 230 V, 1200 mm sweepvalue 6.00mm BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and as directed by Engineer-in-Charge.Note : Old unserviceable Ceiling fan deposited to E/M store. |
| 61 | S&F LED Lamp 9 Watt suitable for lamp holder , complete all as specified and as directed by Engineer-in-Charge. |
| 62 | Supply and fix in replacemet exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as directed.Make:- Havells SKU Code-FHEHDSPDB129 or Usha/BajajNote : Old unserviceable Exhaust fan deposited to E/M store. |
| 63 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. complete all as directed.Make:- Havells SKU Code-GHWAMGSWH025 or Usha/Bajaj Note : Old unserviceable Gyeser deposited to E/M store. |
| 64 | M&L in replacement of PVC insulation tape roll 25 mm X 25 Mtr (LT) including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 65 | S&F in replacement LED lights fitting 1x 40W, 4 feet, 220V,AC decorative box type with driver, holder including LED tube light Warm white type connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings, complete all as specified and as directed by Engineer-in-Charge. |
| 66 | M&L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manufacturer with high pressure pump of 1.0/1.5/2.0 ton capacity,complete all as specified and directed by Engr-in-Charge. |
| 67 | M & L for cutting of suction line and discharge line tubing of AC, de-scaling of front scaled unit flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.0/1.5/2.0 ton Split/W/T type AC complete all as specified and directed by Engr-in-Charge. |
| 68 | M&L for detection/rectification of leakage of gas by vacume the system, charging with Nitrogen gas and vacume the system after detaction of lekage and gas charging in the system with appropriate quantity of gas as per OEM Recomentation including testing for smooth functioning of Split type/ Window type AC of capacity 1.0/1.5/2.0 Ton complete all as specified and directed by Engr-in-Charge. |
| 69 | Supply and topping up of refrigerant gas R-22 in Split/Window air conditioner,of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge. |
| 70 | Supply and topping up of refrigerant gas R-32 in Split/Window air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge. |
| 71 | Supply and topping up of refrigerant gas R-410A in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge. |
| 72 | Supply and topping up of refrigerant gas R-600a in refrigerantor complete all as specified and directed by Engr-in-Charge. |
| 73 | Supply only Butane Gas suitable for torch complete all as specified and directed by Engr-in-Charge. |
| 74 | S&F in replacement of new indoor unit of split AC of capacity 1.5 ton with compitable for existing out door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge. |
| 75 | S&F in replacement of new indoor unit of split AC of capacity 2.0 ton with compitable for existing out door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge. |
| 76 | S&F in outer unit frame/stand sutable for 2.0 TR split ac outdoor unit including grouting nut complete all as specified and directed by Engr-in-Charge. |
| 77 | S&F in replacement of new universal PCB with remote and display complete all as specified and directed by Engr-in-Charge. |
| 78 | Repair/replacement PCB for any make and model window/Split type AC 1.5 ton / 2Ton capacity complete all as directed by Engr-in- charge . |
| 79 | Repair/replacement inverter technology PCB complete with indoor /outdoor unit and sensor for any make and model split type AC 1.5ton/2Ton cap complete all as directed by Engr-in- charge . |
| 80 | Supply and fix in replacement coil senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr –in – charge. |
| 81 | Supply and fix in replacement heating senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr –in – charge. |
| 82 | Supply & fixing in replacement of thimble brass suitable for all type of AC,Water cooler, Referigerator,Deep freezer in pkt complete all as specified and directed by Engr-in- charge. |
| 83 | S&F in replacement blower motor of Split type AC 1.5/2.0 Ton of existing make & model complete all as specified and directed by Engr-in-Charge. |
| 84 | Supply and fix in replacement blower(plastic body) of 1.5/2.0 Ton Split/Window type AC complete all as specified and directed by Engr-in- charge. |
| 85 | Supply and fix in replacement cooling coil of existing shape and size suitable for 1.5/2 Ton Split/Window type AC all as specified and directed by Engr –in – charge. |
| 86 | Supply and fix in replacement condenser coil of existing shape and size suitable for 1.5/2Ton Split/Window type AC all as specified and directed by Engr –in – charge. |
| 87 | Supply and fix in replacement & testing of Fan Motor of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motor of capacity 1/8 HP double shaft for 1.5 /2.0 Ton window type AC including base, frame, side clamps, complete all as specified and as directed by Engineer-in-Charge. |
| 88 | Description same as Srl item No 77.00 Fan motor 1/7 HP of split type AC any make & model complete with base, frame, clamps, side holders, rubber bushes with main lead suitable for Voltas/ LG Make. Make: Air master/Crompton. |
| 89 | Supply and fix in replacement front show grill for LG/Voltas /Sidwal/Godrej window type AC 1.5 Ton complete all as specified and directed by Engr-in-charge. |
| 90 | Supply and fix in replacement of unsv Reverse cycle valve for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr –in –charge. |
| 91 | Supply & fixing flexible drain pipe for Window type/Split Type AC with clamp of any capacity complete all as specified and directed by Engr-in- charge. |
| 92 | Supply and fix in replacement swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton. Make:- LG/Voltas/Hitachi/Godrej. |
| 93 | S&F in replacement of new outdoor unit inverter model with all accessories, without Compressor for split AC of capacity 1.5 ton from authorized dealers of company complete all as specified and directed by Engr-in-Charge. |
| 94 | S&F in replacement of new outdoor unit with inverter model all accessories, without Compressor for split AC of capacity 2.0 ton from authorized dealers of company complete all as specified and directed by Engr-in-Charge. |
| 95 | Supply and fix in replacement Fan Blade of 1.5/2 ton window type AC of any capacity complete all as specified and directed by Engr –in- charge. |
| 96 | Supply and fix in replacement Fan Blade of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge. |
| 97 | Supply and fix in replacement discharge valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge. |
| 98 | Supply and fix in replacement suction valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge. |
| 99 | Supply and fix in replacement bush of 1.5/2 ton split type AC .of any capacity makle LG/ Voltas complete all as specified and directed by Engr –in- charge. |
| 100 | Supply and fix in replacement capillary of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge. |
| 101 | Supply and fix in replacement dead nut of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge. |
| 102 | Supply and fix in replacement NRV of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge. |
| 103 | Supply and fix in replacement of unserviceable remote control unit Suitable for 1.5 / 2.0 Ton split/window type AC complete all as specified and directed by Engr-in- charge. |
| 104 | Supply & fix in replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-Charge. |
| 105 | Taking out old existing unserviceable foam insulation and supply and fix new foam insulation with white taping fixing with clamp of 1.5 / 2 ton split type /window type AC of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE) |
| 106 | S&F in replacement new rotary type AC compressor of existing split type/window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge. |
| 107 | All as per serial item No.41.00 here-in-before but of size 2.0 ton capacity complete all as specified and directed by Engr-in-Charge. |
| 108 | S&F in replacement new Reciprocating type AC compressor of existing split type /window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge. |
| 109 | Description all as per serial item No. 98.00 here-in-before but of size 2.0 ton capacity complete all as specified and directed by Engr-in-Charge. |
| 110 | Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract. |
| 111 | Supply and fix in replacement metal plug and socket board complete enclosure with single pole & neutral and earth plug with MCB SP 32/40 Amps, 220 Volts complete all as specified and directed by Engr-in- charge. |
| 112 | S&F in replacement Wiring for connection between outer and inner unit of split AC with four single core PVC insulated FRLS unsheathed copper conductor multistranded cable 1100 volts grade 2.5sqmm size in PVC conduit heavy duty ISI marked with 2.5 sqmm PVC insulated FRLS copper conductor multistranded cable as earth lead/single to connecting to earth dolly complete all as specified and directed by Engr-in-Charge. |
| 113 | Supply and fixing in replacement water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in - Charge. |
| 114 | Supply and Fix in replacement Fan motor1/20 HP single shaft for water cooler as per the original make of complete fan motorcomplete all as specified and directed by Engr-in-Charge. |
| 115 | Supply and Fix in replacement Fan motor1/35 HP single shaft for water cooler as per the original make of complete fan motorcomplete all as specified and directed by Engr-in-Charge. |
| 116 | Supply and Fix in replacement Fan motor1/70 HP single shaft for water cooler as per the original make of complete fan motorcomplete all as specified and directed by Engr-in-Charge. |
| 117 | S&F compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and directed by Engr-in-Charge. |
| 118 | S&F compressor reciprocating type (hermetically) sealed for capacity 60/120 litre water cooler complete all as specified and directed by Engr-in-Charge. |
| 119 | S&F compressor reciprocating type (hermetically) sealed for capacity 150 litre water cooler complete all as specified and directed by Engr-in-Charge. |
| 120 | Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance all as directed by Engineer - in - charge |
| 121 | Replacement of 'T' junction for desert cooler for watering the three side of the desert cooler with nozzels, complete all as specified and as directed by Engineer-in-Charge. |
| 122 | Replacement of Khas khas set for the doors of desert coolers for different size and make, complete all as specified and as directed by Engineer-in-Charge. |
| 123 | Supply & fix in replacement overload/PTC relay for water cooler ,Deep freezer and referigerator supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigerator satisfactory performance commissioning all as directed. |
| 124 | Supply & fixing flexible drain pipe for Water Cooler of any capacity any size complete all as specified and directed by Engr-in- charge. |
| 125 | Taking out old existing unserviceable spare parts from air curtain such as Air Curtain motor, Air curtain door sensor, Air curtain blower, blower wheels replacement with new and fix of any capacity or size complete all as specified and directed by Engr -in- Charge (as per sample approved by GE). |
| 126 | M&L for repair /repalcement of broken /water leakage from connection of water cooler of capacity 40/80ltr to 150/150ltrs capcity by dismatiling the front sheet of the water cooler tank, removing the thermocol sheet and doing necessary cutting /welding /brazing work to stop the leakage and make good the damaged portion and fixing of tap connection and reassembling the front sheet including provinding the thermocol as a thermal insulation to the water coolers and testing the coolers for no leakage as complete all as specified and directed by Engr- in- Charge. |
| 127 | Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity ,5KVA,2KVA,1KVA,0.5KVA thoroughly checking,cleaning all parts by brushing and assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair / replacement of components as below:- |
| 128 | M&L rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 5KVA. |
| 129 | M&L in replacement of relay for 7.5KVA & 5KVA,30amp 24volts DC. |
| 130 | M&L in replacement of Step down transformer 24 volts 2Amp for 7.5 KVA & 5KVA. |
| 131 | M&L in replacement of plug top 15 Amp. |
| 132 | M&L for Refrigerator/deep freezerof any make and capacity finding the leakage /damage portion. Rectify the leakage and damaged parts and vaccume leakage the whole system. Then charging the refrigerent Gas and confroming no leakage . The reassembling the same deep freezer by provinding proper insulation material at the disturbed area all as per entire satisfaction of Engineer-in- Charge. |
| 133 | Supply and fixing in replacement of Fan motor with fan suitable for any make & model refrigerator 286ltr / 310 Ltr complete all directed by Engr-in-Charge |
| 134 | Description all as per srl item No 120.00 above but suitable for 165 to 195 litre Refrigerator complete all as specified and directed by Engr-in- Charge . |
| 135 | Description all as per srl item No 120.00 above but suitable for 320 litre Deep freezer complete all as specified and directed by Engr-in- Charge . |
| 136 | Taking out old unserviceable Condensing coil for 165/170 to 310 Litre Referigerator and supply and fix new condenser coil of existing make shape and size all as directed by Engr-in-Charge. |
| 137 | Supply and fix new thermostate for Refrigerator/Deep freezer of any capacity any make complete all as specified and directed by Engr –in- charge. |
| 138 | S&F in replecement new sealed compressor suitable for Deep Freezer of single phase, 230 Volt, 50 Hz of Deep Freezer of any Size in and including refrigerant gas filling up to required level complete all as specified and directed by Engr-in-Charge. |
| 139 | S&F in replecement new sealed compressor of suitable for Refrigerator of single phase, 230 Volt, 50 Hz of Refigerator of any Size in and including refrigerant gas filling up to required level complete all as specified and directed by Engr-in-Charge. |
| 140 | S&F in replacement of Cabin Display of lift , make as per sample complete all as specified and directed by Engr-in-Charge. |
| 141 | S&F in replacement of Landing circuit Unit ((LOP/LCU) of lift, make as per sample complete all as specified and directed by Engr-in-Charge. |
| 142 | Supply and fix in replacement Capacitor of capacity 50+6 mfd for window /split type AC complete all as specified and directed by Engr –in- charge. |
| 143 | Supply and fix in replacement Capacitor of capacity 45+5 mfd for window /split type AC complete all as specified and directed by Engr –in- charge. |
| 144 | Supply and fix in replacement Capacitor of capacity 80+100 mfd for water cooler complete all as specified and directed by Engr –in- charge. |
| 145 | Supply and fix in replacement Capacitor of capacity 10 mfd for water cooler complete all as specified and directed by Engr –in- charge. |
| 146 | Supply and fix in replacement diffrerent make and size shelf of refrigerator all as specified and directed by Engr –in- charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |