| 1 | Schedule 'A' |
| 2 | Supply and fix in replacement of existing wornout unserviceable Contactor 4-pole KCL54 150 suitable for existing DG set set complete all as specified and directed.Make - L & T/Koel/Havells |
| 3 | Supply and fix in replacement of existing wornout unserviceable Contactor 4-pole MCX-32 suitable for existing DG set complete all as specified and directed.Make - L & T/Koel/Havells |
| 4 | Supply and fix in replacement of existing wornout unserviceable Contactor 4-pole MCX-22 suitable for existing DG set complete all as specified and directed.Make - L&T/Koel/Havells |
| 5 | Supply and fix in replacement of battary charger 12 V DC 10 Amp for Dg set of 15 to 160 KVA complete all as specified and as directed. |
| 6 | M&L for repair/Servicing to Alternator (Dynomo) including replacement of defective parts and overhauling the same, and refixing on engine. 160 KVA. |
| 7 | M&L for repair/Servicing to Alternator (Dynomo) including replacement of defective parts and overhauling the same, and refixing on engine. 40/62.5 KVA. |
| 8 | M&L for repair/Servicing to Alternator (Dynomo) including replacement of defective parts and overhauling the same, and refixing on engine. 30/15 KVA. |
| 9 | Supply and fixing Lug copper suitable cable size of 16 to 50 sqmm complete all as specified and directed Engineer-in-Charge. |
| 10 | Supply and fixing Lug aluminium suitable cable size of 25 to 95 sqmm complete all as specified and directed Engineer-in-Charge. |
| 11 | Supplying and laying synthetic Rubber insulated mats 3.0 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m |
| 12 | M&L for repair/Replacement of Fe 410-W (Gde E- 250) for Room/Power Room/DG Room Duct Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy racket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc |
| 13 | Supply and fix in replacement of defective automatic voltage rectifier of 160 KVA DG set complete all as directed.. |
| 14 | Supply and fix in replacement of defective automatic voltage rectifier of 15/ 30/62.5/40KVA DG set complete all as directed.. |
| 15 | M & L for Repair to Rusted/damaged canopy of DG Set capacity 15/30KVA of MS plain sheet as per match existing sheet. Repair of canopy after cut off power supply /remove all electrical connections of DG set complete all as specified and directed. |
| 16 | Supply and fix in replacement of digital display AMF controller of DG Set of capacity 160KVA for operating DG set on / off/ reset/ other rating functions & calibration complete set suitable for monitoring on DG set complete all as specified and directed. |
| 17 | Supply and fix in replacement of digital display of DG Set of capacity 62.5/40KVA for operating DG set on / off/ reset/ other rating functions complete set suitable for monitoring on DG set complete all as specified and directed. |
| 18 | Supply and fix in replacement of digital display of DG Set of capacity 30/15KVA for operating DG set on / off/ reset/ other rating functions complete set suitable for monitoring on DG set complete all as specified and directed. |
| 19 | Supply and Repair/Replacement of Onload change over switch 250 Amp four pole changeover with advance neutral ss encloser, 415 Vac, 50 Hz by connecting the electrical connection and fixing on panal with nut, bolt,clamps complete all as specified and as directed by Engr-in-Charge. Make Havells/ C&S/L&T |
| 20 | Supply and Repair/Replacement of Onload change over switch 160 Amp four pole changeover with advance neutral ss encloser, 415 Vac, 50 Hz by connecting the electrical connection and fixing on panal with nut, bolt,clamps complete all as specified and as directed by Engr-in-Charge. Make Havells/ C&S/L&T |
| 21 | Supply and Repair/Replacement of offload change over switch (side handle) with SS encousure, switch gear 100 Amp Triple Pole with Neutral Link, 415 Vac, 50 Hz connecting the electrical connection and fixing on wall or panel with clamp nut, bolt,clamps complete all as specified and as directed by Engr-in-Charge. Make Havells/ C&S/L&T |
| 22 | S & F and testing Electronic Governor Controller for capacity 160 KVA DG Set including taking down old Governor Controller. |
| 23 | S & F and testing Electronic Governor Controller for capacity 62.5 KVA DG Set including taking down old Governor Controller. |
| 24 | S & F and testing Electronic Governor Controller for capacity 30/40 KVA DG Set including taking down old Governor Controller. |
| 25 | S & F and testing Electronic Governor Controller for capacity 15 KVA DG Set including taking down old Governor Controller. |
| 26 | Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldfor for DG sets 160 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed. |
| 27 | All as per Ser item No 25.00 but of capacity 62.5 KVA |
| 28 | All as per Ser item No 25.00 but of capacity 40 KVA |
| 29 | All as per Ser item No 25.00 but of capacity 15 to 30 KVA |
| 30 | Supply & Fix in replcement of Voltmeter analog type for voltage range of (0-24V) as per matching to existing complete with all accessories and wiring. |
| 31 | Supply & Fix in replcement of Ammeter analog type for current range of (0-24Amps) as per matching to existing complete with all accessories and wiring. |
| 32 | M&L for checking the tappet clearance and adjustment of valve including replacement of tappet gasket for DG Set 15 to 30 KVA. |
| 33 | M&L for checking the tappet clearance and adjustment of valve including replacement of tappet gasket for DG Set 40 to 62.5 KVA. |
| 34 | M&L for checking the tappet clearance and adjustment of valve including replacement of tappet gasket for DG Set 160 KVA. |
| 35 | M&L for draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 15 to 30 KVA complete all as specified and directed |
| 36 | M&L for draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 40/62.5 KVA complete all as specified and directed |
| 37 | M&L for draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 160KVA complete all as specified and directed |
| 38 | Taking down the old U/S Actuator from its position and S&Fnew actuator for 160 KVA DG Set complete including taking down old actuator. |
| 39 | Taking down the old U/S Actuator from its position and S&F new actuator for 40/62.5 KVA DG Set complete including taking down old actuator. |
| 40 | Taking down the old U/S Actuator from its position and S&F new actuator for 15 to 30 KVA DG Set complete including taking down old actuator. |
| 41 | Supply and fix in replacement of turbo chargers repairs kit suitable for DG set 160 KVA. |
| 42 | Supply and fix in replacement of turbo chargers repairs kit suitable for DG set 40/62.5 KVA. |
| 43 | Supply and fix in replacement of turbo chargers repairs kit suitable for DG set 15 to 30 KVA. |
| 44 | Supply and fix in replacement of Fire Fighting Panel Supplying, Installation, Testing and Commissioning of Control Panel suitable for automatic operation of fire fighting pumps consisting(a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price. (b) Facility for more selections i.e auto or manual.(c) Protection failure and control cabling. (d) interlocking of pressure switch with pumps (e) Soft starter |
| 45 | Supply and fix in replacement of MS flanged pipe 150 mm NB heavy duty for multi storied building dully painted with 2 coats of synthetic enamel paint over a coat of zink chromate primer. Including necessary fittings, like bends, tees, elbow,flanges, reducers, expanders, gaskets, with nuts, boltsand washers confirming to lS flanged/weldied joints providing and including Raping coating for MS Pipe complete all as specified and as directed. |
| 46 | Supply and fix in replacement of Sluice Valves, , flanged of class 1.6 PN ,150 mm dia complete all as specified. |
| 47 | Supply and fix in replacement installatin,Testing & Commissioning of cast iron BUTTERFLY VALVE of size 150mm as per ISI:Marked with necesarry fittings as per specification. Details: The Butterfly Valve shall be suitable for water works and tested to minimum of 20 kg/cm2 pressure. The Valves shall fulfill the requirments of AWWA (American Watwe Works Association) C 504, API 609 and MMS- SP- 67. The body shall be of cast iron confirming to IS:210 in circular shape and high strength to take the minimum water pressure of 10 kg/cm2. The disc shall be heavy duty cast iron with anticorrosive epoxy or nickel coating complete all as specified and as directed.Make:- AUDCO/Kirloskar/Intervalve, |
| 48 | Supply and fix in replacement of fire hydrant landing valve type A (Single head outlet) of 80 mm dia conforming to IS 5290. complete all as specified and as directed. |
| 49 | Supply and fix in replacement of pressure gauge 150mm dia with ball valve of pressure 25 Kg/sqcm complete all as specified and as directed. |
| 50 | Supply and fix in replacement of hose box for keeping 2 Nos hose pipe of length 15 mrt each, branch pipe , nozzle, coupling etc of MS sheet of thickness 2.0 mm.complete all as specified and as directed. |
| 51 | Supply and Fixing in Replacement of Chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 32x6mm as per SSR Part -I complete all as specified and as directed. |
| 52 | Disconnecting and taking out damaged existing any type strip and S&F of copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed. |
| 53 | Desconnecting and taking out unserviceable any type Air termination rod and S&F of Air termination, single pointed copper rod 12mm dia and 300mm long all as specified and directed. |
| 54 | Desconnecting and taking out unserviceable Test point terminal block and supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed. |
| 55 | Supply and Repair/Replacement of poroceline insulator for laying of ligtning strip on the roof/ wall for maintain distance from suface and strip of suitable size and distance between two insulator minimum 1mtr complete all as specified and directed. |
| 56 | M&L in Replacement of earthing complete with Copper earth plate electrode of size 60cm×60cm ×3.15mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to earthing copper strip of size 20×3mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed. |
| 57 | S&F in replacement of DLP U PVC trunking system Plastic adoptable type 150x50mm with two compartment duly covered installed with suitable support joints including all accessories complete all as specified and as directed.( Make :Legrand/AKG/BEC) |
| 58 | S & F GI slotted type cable trays of the following sizes using MS angle, channels, flats etc. All MS supports used shall be given one coat of red oxide primer & 2 coats of synthetic enamel paint of approved colour of size 150 x 50 mm x 2mm complete all as specified and directed. |
| 59 | Material and Labour in replacement Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for for HT, 25x20cm size complete all as specified and directed. |
| 60 | S&F in replacement of Switching mode power supply 230 Volt AC to 24 Volt Dc converter from main existing DB to MCP and Hooter point complete all as specified and as directed. |
| 61 | Supply & Fixing in replacement of Fire Alarm sounders / Sirens electronictype horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5db 1500m range complete all as specified and directed. |
| 62 | Supply & Fixing in replacement of Addressable manual call point resettabletype complete all specified and directed. |
| 63 | Supply & Fixing in replacement of Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination with base with self built intelligence as per IS: 11360 complete all as specified and directed. |
| 64 | Supply and fix in replacement Mild Steel class 'C' diesel pump exhaust pipe 80/100mm dia of length 10mtr with one layer of 10mm thick asbestos rope insulation and including all fitting clamp/ Welding and structural steel supports complete |
| 65 | Supply & Fix inreplacement of Escape light complete all as specified and as directed. Please Enable Macros to View BoQ information |