| 1 | Dismantling of Asbestos cement (corrugated, semicorrugated and Transulent sheet etc) sheets/ mangalore tiles in roof covering incl ridges complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 3 | M&L for Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridges fixed with self tapping screws complete all as specified and directed. |
| 5 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Grade Fe 410 -W (Gde E- 250) quality A.complete all as specified and directed. |
| 6 | M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 7 | Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof padding etc and removing of debris from outside MD land complete all as specified and as directed. |
| 8 | M&L for 10 mm thick Plaster on RCC roof slab and sunken portion with CM ( 1:3 ) mixed with water proofing compound @ 3% by weight of cement or as per manufacturer's instruction shall be carried out.complete all as specified and directed.(Note : WPC shall be measured and paid separately under relevant item) |
| 9 | M&L for PCC (1:2:4) type B-0, using 12.5 mm graded crushed stone aggregate as in roof padding / sunken floors and similar work mixed with WPC @ 3% by wt of cement or as per manufacturer's instruction.complete all as specified and directed.(Note : WPC shall be measured and paid separately under relevant item) |
| 10 | Supply only Integral Water proofing Compound complete all as specified and as directed. |
| 11 | Material and labour for Water Proofing Treatment with APP based Standard Membrane over PCC padding in approachable roof with the following courses of treatment :(a) Apply bituminous primer ( IS 3384 ) @ 0.30 Kg per Sqm of the surface area including cleaning the surfacecomplete all as specified and directed.(b) Apply APP plastomeric bitumen based water proofing membrane polyester reinforced (3.50kg /Sqm ) with 10 cm overlaps and torch bonded at joints including surface preperation before and after application of treatment as per manufacturers instruction. |
| 12 | M&L for applying a coat of reflective bitumenous aluminium paint @ 0.15 Kg / sqm over Bitumen surface complete all as specified and as directed. |
| 13 | Demolition of Precast cement concrete block walling built in CM.complete all as specified and as directed. |
| 14 | M&L for precast cement concrete block masonry exc. 10 cm width with solid block C1 (1:3:6) (using 20 mm graded crushed stone aggregate) and setting in cement mortar (1:6) complete all as specified and directed. |
| 15 | S& F in repairs for 20mm bore CPVC pipe outer dia of pressure ratings 11 SDR-II including all fittings fixed complete to walls, ceiling or in floor etc.complete all as specified and directed. |
| 16 | S& F in repairs for 25mm bore CPVC pipe outer dia of pressure ratings 11 SDR-II including all fittings fixed complete to walls, ceiling or in floor etc.complete all as specified and directed. |
| 17 | S&F in repairs for providing 25mm dia CPVC gate valves screwed both ends for iron pipes.complete all as specified and directed. |
| 18 | S&F rotational moulded Polyethylene [HDPE] water tanks, Triple layered, ISI Marked Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including taking down old tanks complete all as specified and as directed. |
| 19 | S&F rotational moulded Polyethylene [HDPE] water tanks, Triple layered, ISI Marked Cylindrical & Vertical Type 500 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including taking down old tanks complete all as specified and as directed. |
| 20 | Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc. 500 liters and not exc. 1000 liters complete all as specified and as directed.(Note: Each tank will be shifted as twice) |
| 21 | Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc.250 liters and not exc. 500 liters complete all as specified and as directed.(Note: Each tank will be shifted as twice) |
| 22 | Cleaning of RCC/PVC water tanks with bleaching powder removing all scale and dirt etc from tank and from tanks and from mouths of circulating pipes, etc including writing with paint out side tanks \\"tanks cleaned on with month and year capacity of tanks exc 250 & n. exc 1000 ltrs and recconecting air lock complete all as specified and as directed. |
| 23 | S&F in repairs 20mm PTMT dia Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 24 | Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets.complete all as specified and directed. |
| 25 | S&F for anodoised aluminium powder coated snap grid frame work for ceiling 605mm x 605mm using aluminium anodoised sections specified in SSR part-I 1991 including cutting, drilling jointing ect complrtr including 4mm dia of GI hangers wire suspenders fixed with adjustable connectors and providing 6mm thick E-boards (Classic) 605mm x 605mm size.complete all as specified and directed. Please Enable Macros to View BoQ information |