| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK : REPAIR TO ROOF TREATEMENT, SUNKEN TREATMENT & ALLIED WORKS TO VARIOUS BLDGS AT HQTC BANGALORE CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Demolition of unreinforced concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.Notes:- All debris and rubbish shall be removed from MoD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state and local regulations. |
| 3 | M&L Plain cement concrete 1:2:4, type B1 (20mm graded stone aggregate) as in padding over roof, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 4 | M&L 40mm thick Plain Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) complete all as specified and directed. |
| 5 | Taking down old damaged existing water proofing membrane of any thickness from roof top complete all as specified and directed. |
| 6 | M&L for Rendering 10mm thick cement plaster in cement mortar 1:3, mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces or roof surfaces, finished even and smooth without using extra cement complete all as specified and directed.Note: Liquid WPC shall be measured and paid separately. |
| 7 | M&L for Water proofing treatment on horizontal or vertical surfaces by applying bitumen primer @ 0.20 Kg/Sqm and providing 4 mm thick APP modified water proofing membrane weighing not less than 4 Kg/Sqm reinforced with non-woven polyester matt weighing not less than 160 gm/sqm including minimum 10 cm side lap and 15 cm end lap torch sealed and bonded and applying a coat of blown grade hot bitumen 90/15 over and below the membrane @ 1.20 Kg/Sqm in drying over the membrane finished with solar reflective bituminous aluminium paint/primer @ 0.1 Kg/Sqm over RCC roof slab/ projection/ parapet after cleaning the surfaces by removing dust dirt etc as manufactures instructions complete all as specified and directed. |
| 8 | M&L for applying a coat of blown industrial bitumen of grade 85/25 or 90/15 applied hot to concrete, wall surfaces @ 1.2Kg/Sqm or as required including cleaning the surfaces complete all as specified and directed. |
| 9 | M&L for digging out roots of bushes, small trees, grass of any dia & girth from inaccessible roof projection, chajjas, wall junction, parapet etc up to roof top of 1st floor and applying herbicide 2,4-Dichlorophenoxyacetic acid including necessay demolition of brick work/ stone masonary/ conrete/ RCC wall or slab etc and filling holes and levelled with cement concrete B-0, 1:2:4 (12.5mm graded stone aggregate) and necessary rendering of cement mortar 1:4 after applying damp proof epoxy based primer and matched with existing surfaces complete all as specified and directed. Note: Rates quoted are inclusive of necessary scafolding. |
| 10 | Sunken Waterproofing Surface Preparation :Taking out/ down old existing sunken slab treatment and cleaning the old RCC surfaces of sunken /lowered portion of slab surface for full depth of sunken floor by wire brush or chisel out any mortar sticking the surface all as specified and directed including cleaning and preparation of the substrate to receive Fosroc Polyurea water proofing system or equivalent product of Asian paints, M/S MC Bauchemic /CIPY/SIKA/Pidilite Dr Fixit/ Thermax/ STP shall be a sound base free from any oil, grease, rust, or deleterious material which may impair adhesion. The surface preparation shall be carried out mechanically to remove contaminants, laitance & weak concrete, to expose blow holes, and to produce a sound concrete with adequate profile and porosity. Any crack shall be treated with cementitious repair mortar of Fosroc Renderoc CS or epoxy crack filling mortar or equivalent product by proper grooving arrangement complete all as specified and directed. |
| 11 | Bore Packing (for Reinstallation) : Preparing the inside surface of core and PVC by roughening using suitable file to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Applying a coat of styrenebutadiene based polymer coating using Nitobond SBR or equivalent product of Asian paints, M/S MC Bauchemic /CIPY/SIKA/Pidilite Dr Fixit/ Thermax/ STP admixed with integral WPC or cementitious crystalline waterproofing compound to enhance adhesion between the packing material and other surfaces. Packing the gap using nonshrink cement polymer-based grout using conbextra GP2 upto the surface of the bore whilst the Nitobond SBR is in tacky state. The above analysis is based on assumption for 150mm diameter core with 110mm diameter PVC for 5”thick slab only. Typical Properties Compressive strength at 28day as per BS 1881 45N/mm2, completely as per the manufacturer’s Instruction complete all as specified and directed. |
| 12 | Coving treatment:Making coving of 50mm X 50mm at all the flat & vertical junction using Fosroc Renderoc S Single component, shrinkage compensated, fiber reinforced, thixotropic cementitious mortar, to achieve a minimum compressive strength of 20 MPa in 1day and 55 MPa in 28days when tested as per EN 12190 and capable of applying 50mm thickness in single layer of approved product finished flush with existing surface complete all as specified and directed. |
| 13 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing complete all as specified and directed. |
| 14 | M&L Brushing neat cement slurry with 3.0 kg of cement per sq m complete all as specified and directed. |
| 15 | M&L for digging out roots of bushes, small trees, grass of any dia & girth from accessible roof projection, chajjas, wall junction, parapet etc at any height and applying herbicide 2,4-Dichlorophenoxyacetic acid including necessay demolition of brick work/ stone masonary/ conrete/ RCC wall or slab etc and filling holes and levelled with cement concrete B-0, 1:2:4 (12.5mm graded stone aggregate) and necessary rendering of cement mortar 1:4 and after applying damp proof epoxy based primer and paint the surface matched with existing surfaces complete all as specified and directed. |
| 16 | M&L for digging out roots of bushes, small trees, grass of any dia & girth from inaccessible roof projection, chajjas, wall junction, parapet etc from roof top of 4th floor and above and applying herbicide 2,4-Dichlorophenoxyacetic acid including necessay demolition of brick work/ stone masonary/ conrete/ RCC wall or slab etc and filling holes and levelled with cement concrete B-0, 1:2:4 (12.5mm graded stone aggregate) and necessary rendering of cement mortar 1:4 after applying damp proof epoxy based primer and matched with existing surfaces complete all as specified and directed. Note: Rates for necessary scafolding are included. |
| 17 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. After cleaning repairing, and removing all scale dirt and wiping, drying etc complete capacity in ltr not exc1000 liter (cylindrical vertical with closed top) complete all as specified and directed. |
| 18 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. After cleaning repairing, and removing all scale dirt and wiping, drying etc complete capacity in litres exc 1000 and not exc 2000 ltr (cylindrical vertical with closed top)complete all as specified and directed. |
| 19 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 20 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming Fe 410-W (Gde E-250) quality A, complete all as specified and directed. |
| 21 | M&L Preparing new steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zinc primer, complete all as specified and directed. |
| 22 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. Including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 23 | M&L for Rendering 15mm thick on fair faces of brick works or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed. |
| 24 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 25 | M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion white or tinted through mechnical means over a coat of 1mm thick wall care putty complete all as specified and directed. |
| 26 | M&L Rendering 10mm thick cement plaster in cement mortar 1:3, on concrete sufaces as in ceiling, finished even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for preparing new plastered on wall and applying three coats of white wash complete all as specified and directed. |
| 28 | M&L for preparation of new plastered surface of ceiling and applying two coats of distemper oil emulsion white or tinted through mechnical means over a coat of 1mm thick wall care putty complete all as specified and directed. |
| 29 | M&L for rendering 15mm thick cement plaster in cement mortar 1:4 with and including water proofing compound on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 30 | M&L for preparation of new plastered surfaces and applying two coats of cement paint through mechnical means over a coat of alkali resistant priming paint complete all as specified and directed. |
| 31 | Dismantling boarding,ceiling with frame work any description, fixed in any position with nails complete all as specified and directed. |
| 32 | S&F Tee grid suspension system of size 600 mm x 600 mm type-1 made out of rolled framed hot dipped galvanised steel zinc coated of not less than 120 gm/sqm ,main runner shall be 0.3 mm thick of section 24 mmX33 mm cross runner 0.3 mm thick of section 24 mm x 25 mm,wall angle shall be 0.63 mm thick of section 24 mmx24 mm grid shall be suspended by 6 mm dia adjustable quick fit hanger rod ,system exposed portion shall be pre painted polyster coated in off white/white in colour complete with material,fixing, jointing etc all as per manufactures instructions complete all as specified and directed. |
| 33 | M&L Fibre cement coloured textured designer ceiling board 4mm thick of size 595x595 mm conforming to IS : 14862 & IS : 2380 Part-XIV fixed to timber / GI / Aluminium frame work with screws/clips complete all as specified and directed. |
| 34 | Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 35 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 36 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall or in door, fixed with self tapping screws complete all as specified and directed. |
| 37 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dresses stonework and precast concrete articles complete all as specified and directed. |
| 38 | M&L for Precast cement concrete block masonry type C1 1:3:6 (20mm graded stone aggregate) with solid blocks, exc. 10cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 39 | M&L for providing precast cement concrete solid building blocks type C1 1:3:6 (20mm graded aggregate) 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:4, complete in walls complete all as specified and directed. |
| 40 | Dismantling water tanks, capacity in litres exc 500 & n exc 1000 and removing to store complete all as specified and directed. |
| 41 | S&F Rotational moulded polyethylene water storage tanks, capacity in litres 1000 (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 42 | S&F in repair ball valves 20mm dia, high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) |
| 43 | S&F in repair for PTMT Tank nipple 20mm dai etc complete all as specified and directed. |
| 44 | S&F in repair for PTMT Tank nipple 25mm dai etc complete all as specified and directed. |
| 45 | S&F in repairs PVC (SWR) pipes 150mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors/wall complete all as specified and directed. |
| 46 | S&F in repairs PVC (SWR) bends 150 mm bore of any radius complete all as specified and directed. |
| 47 | S&F in repairs PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 48 | S&F in repairs PVC (SWR) bends 110mm bore of any radius complete all as specified and directed. |
| 49 | S&F in repairs PVC (SWR) pipes 75mm bore, single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 50 | S&F in repairs PVC (SWR) bends 75mm bore of any radius complete all as specified and directed. |
| 51 | S&F in repairs Low density polyethylene (LDPE) pipes 32mm dia, of pressure rating 6 kgf/sq. cm with all fitting complete all as specified and directed. |
| 52 | S&F in repair of CPVC pipe with outer dia 16mm SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors including elbow, Tee, and all necessary fittings etc complete al as specified including taking up or down old pipe complete all as specified and directed. |
| 53 | S&F in repair of CPVC pipe with outer dia 20mm SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors including elbow, Tee, and all necessary fittings atc completed al as specified including taking up or down old pipe complete all as specified and directed. |
| 54 | S&F in repair of CPVC pipe with outer dia 25mm SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors including elbow, Tee, and all necessary fittings atc completed al as specified including taking up or down old pipe complete all as specified and directed. |
| 55 | S&F in repair of CPVC pipe with outer dia 32mm SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors including elbow, Tee, and all necessary fittings atc completed al as specified including taking up or down old pipe complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |