| 1 | Providing and fixing of front doors in place of missing or broken door of existing pedestal of size 1200x900x350 mm. The door is to be fixed by welding hinges at site with the help of welding set. The job also includes the cost of painting of the complete pedestal to the entire satisfaction of Engineer in charge. |
| 2 | S/F DP MCB isolator: Supplying & fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens. The work shall be executed to the entire satisfaction of Engineer in charge. 63 amps |
| 3 | Supply & Erection of PVC Insulated sheathed) Copper Conductor Cable ISI marked size 2 core 6 mm2.Supply & Erection of ISI Marked PVC insulated 2 core 6 mm2 cable of Copper Conductor (Sheathed) make Finolex/ Lapp/ Polycab/ Havell's/ left bare in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size 2 core 6 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 4 | S/F’C series, SP MCBSupply and fixing 6 amps to 32 amps rating, 240 volts ‘C’ series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing and commissioning etc as required. Single pole 16 Amps “C” series Make of Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge. |
| 5 | Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable loose in trench/pipe:-Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable of make Havells/ Finolex/ Ecko/ Lapp/ Cirtina/ Sunhome/ Polycab/ KEI/ conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2018 MV CB PIP-25 Part-II (External). Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:- i) Conductor – Aluminumii) Core – 4iii) Working Voltage – 1100 Viv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6vi) Insulation Thickness – 1.0mm (Nominal)vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mmix) Nominal size of Armoured Wire/Strip – 4x0.8mmx) Approximate O.D. – 22mmMaximum d.c. Resistance at 20 Deg. C – 1.91 ohm/kmThe work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 6 | S&E of Mouled Case Circuit Breakers (MCCB) of rating 63 Amp with Breaking Cap 26 kA, 415 Volts.Supply & Erection of 3 pole, 26 kA, 63 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 7 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubiclepanel, making connections, etc. as required The TP&N should be make Havells/ ABB/ L&T/ Legrand/ Schneider. 200 A TP&N DSR 2.1.6 |
| 8 | Supply & Laying of DWC pipe 51/63mm without hand bockey:- DSR 14.16.1Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) Without Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930, complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling of digging including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. |
| 9 | Supply & Laying of DWC pipe 51/63mm with hand bockey:- DSR 14.15.1 Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930,/ IS-16205 part ii complete with fitting and cutting, jointing etc.direct in ground (depth as per the directions of Engineer in charge or upto 75cm below ground level) including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. |
| 10 | Supply & Erection of Exhaust Fan (14” sweep (300mm) 900 RPM of Panasonic (Anmol 13160) Havell’s/ Bajaj/ Crompton make complete with motor blades along with louver to be installed on existing hole in wall/ glazing with suitable arrangement. The rate includes cost of all labour, carriage to site, testing, commissioning of Exhaust fan & connection to existing light panel. The job shall be executed to the entire satisfaction of Engineer-in-charge. |
| 11 | Point wiring in PVC conduit, with modular type switch: DSR 1.10.3 Wiring for light point/fan point/exhaust fan point/ cal bell point with 1.5 sq.mm FR PVC insulted copper conductor single core cable in surface/ recessed PVC Conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. Group-C |
| 12 | S/E of Ceiling Fans 1200mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Havell's/ Bajaj/ Crompton/ Panasonic including making connection with 23/.076' flexible wire to be adjacent fan point with regulator. The work shall be executed to the entire satisfaction of Engineer in charge. |
| 13 | Full stator copper rewiding of an ceiling fan (condensor type) of 1200 mm sweep including (ball bearing if required) and cleaning and insulating the stator slots, sleeving, soldering, wrapping of cotton tape, re-assembling, varnishing and testing etc. complete in all respect. (in working condition) |
| 14 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). DSR 1.56 |
| 15 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required(.3 x 1.5 sq. mm DSR 1.17.3. |
| 16 | 3 x 2.5 sq. mm DSR 1.17.12 |
| 17 | Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR 1.12 |
| 18 | Supply & Erection of 2x18 watt retrofit LED tube rod Supply & Erection of 2x18 watt retrofit LED tube rod made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (3600 LUM) with LM 79 report from NABL. The make of the fittings should be Phillips/ GE/ Osram/ Twinkle. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 19 | Supplying and fixing brass batten/ angle holder including connection etc. as required. DSR 1.34 |
| 20 | PVCCON S/F PVC Conduit:Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. 32 mm DSR 1.21.3 |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch DSR 1.24.1 |
| 22 | 3 pin 5/6 A socket outlet DSR 1.24.4 |
| 23 | 6 pin 15/16 amp socket outlet DSR 1.24.5 |
| 24 | 15/16 Amps switch DSR 1.24. 3 |
| 25 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) DSR 1.27.4 |
| 26 | Supply & Erection of steel tubular pole 410 SP-27 conforming to IS-2713-1980, (Part-I & II) having overall length of 9 Meter and welded in 3 steps and having approximate Wt. 108 Kgs. With the following specifications:-a) The poll shall have cross-sectional length of 5.00, 2.00, 2.00 Mtrs.b) The outside dia and thickness shall be114.3x5.40mm, 88.9x4.85mm and 76.1x3.25mm.c) The pole shall be erected 1.50mtrs. Below the ground level in 8” internal ready made RCC muff.d) The gap between the pole and the muff shall be filled with the cement concrete 1:2:4.The cost includes all labour and material including carriage to the site of work. e) The bottom portion of the pole shall be painted with two coats of black paint after removing the dust/rust.The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 27 | Supply and Erection of round shape bracket made out of G.I. pipe 40mm dia as per drawing i.e. inner dia of the round bracket should be 1.5 meters. The pipe ring shall be supported with four No G.I pipe supports welded at the centre with a conopy shaped pipe of size 5” dia and 0.45 mtr long to be erected on the top of the pole for supporting the fittings. The round Bracket and conopy shall be joined together in such a way that it shall give a symmetrical look. The job includes the drilling of sufficient number of holes in the bracket to erect the fittings and all material i.e. painting, grinding, welding, fabrication, drilling, nuts and boalts etc to complete the job to the entire satisfaction of Engineer-in-charge. |
| 28 | Supply & Erection of PVC Insulated sheathed) Copper Conductor Cable ISI marked size 3 core 2.5 mm2.Supply & Erection of ISI Marked PVC insulated 3 core 2.5mm2 cable of Copper Conductor (Sheathed) make Universal/ Finolex/ Lapp/ Polycab/ Havell's/ left bare/ Sunhome in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size 3 core 2.5 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 29 | S/E of CC Collars including following:- a) The box shall be enclosed in a cement collar made from cement concrete 1:2:4 with outside dia 16”. b) The collar shall be embedded in the group upto 6” shall stand 9” above ground shall have housed 12” high SMC Box and 6” top over the box.c) The collar shall be provided with 2/3 G.I. Pipe of 40mm dia and 45cm long to facilitate entry of cables in the junction box.d) The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality.e) Providing and Fixing junction box of size 250x200x100mm inside dimensions of SMC material of robust construction with double hinge, with MS side clamp, locking arrangement. There should be a terminal Strip (Thimble type) 30 amp, one no. Kitkat, rating suitable for minimum 4x16 sq.mm aluminum cable termination.The sheath of the armoured cable should be properly thimbed with the pole for proper earthing. Curing of CC Collar must be done as per satisfaction of Engineer-in-charge. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect. |
| 30 | G.I. Earth pipe electrode with salt/ Charcoal: DSR 5.2/2022 Supply and laying of earth electrode made out of ISI marked 'B' class earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, G.I. pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom (with charcoal or coke and salt). The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge. |
| 31 | P/F 6 SWG GI earth wire in pipe: DSR 5.12/2022 Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. |
| 32 | PAINTING & NUMBERING OF POLES 7.5/9 MTR. LONG: -Painting of poles above ground level with two coats of paint of Nerolec/ Asian/ ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/ rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. DANGER shall be written on each pole on its two sides with red paint on yellow base such that it may be visible clearly from far. The job includes all type petty material require to complete the job to the entire satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information |