| 1 | Demolition of cement concrete, un-reinforced in ground floors and paving not exceeding 15 centimetre thickness, below or above ground level complete all as specified and as directed. |
| 2 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars etc complete all as specified and as directed. |
| 3 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation or for shafts, wells, cess pits, manholes etc not exc 10 sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil. |
| 4 | M&L for Hardcore of guage exc 63mm but not exc. 100mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rolled/ rammed to a true surface complete all as directed by Enginer in Charge. |
| 5 | M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundations filling in mass concrete all as directed by Engineer in Charge. |
| 6 | M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in floor 100 mm thick complete all as specified and directed by Engr-in-Charge. |
| 7 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed by Engineer in Charge. |
| 8 | Removing excavated material (soils) exc 250 mtr but not exc 500 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 9 | M&L for approved good earth filling in floors or pavings, laid in layers not exc. 15 cm thick, spread, levelled and rammed including watering all as directed by Engineer in Charge.Note : Earth obtained from excavation shall be used. |
| 10 | M&L for Treating the bottom and sides of excavation at the rate of 5 litres of ATT emulsion per square metre of surface area all as directed by Engineer in Charge. |
| 11 | M&L for Treating the back fill in contact with foundation at the rate of 7.5 litres of ATT emulsion per square metre of vertical surface all as directed by Engineer in Charge. |
| 12 | M&L for Treating the soil under plinth protection at the rate of 5 litres of ATT emulsion per square metre of surface area all as directed by Engineer in Charge. |
| 13 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of ATT emulsion per metre of the perimeter wall all as directed by Engineer in Charge. |
| 14 | M&L for brick work with old size bricks,straight or curve on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 15 | M&L for brick work with old size bricks,straight or curve on plan to any radius in half brick thick wall built in cement mortar 1:6 complete all as specified and directed. |
| 16 | M&L for RCC Type B1 (1:1.5:3) (using 20 mm graded stone aggregate) as in foundation, footing & plinth beam etc complete all as specified and directed. |
| 17 | M&L for RCC type B1 (1:1.5:3) using 20mm graded stone aggregate as in roof beam & lintel band complete all as specified and directed. |
| 18 | M & L for RCC type B1 (1:1.5:3) (with 20 mm graded stone aggregate) as in roof slab complete all as specified and directed. |
| 19 | M & L for RCC type B1 (1:1.5:3) (with 20 mm graded stone aggregate) as in column complete all as specified and directed. |
| 20 | M&L for RCC type B1 (1:1.5:3) using 20mm graded stone aggregate as in chajja/ shelf complete all as specified and directed. |
| 21 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface all as specified & directed by Engineer in Charge. |
| 22 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work, not exceeding 200 mm thick (Horizontal or sloping) of flat surfaces of concrete complete all as specified and directed. |
| 23 | M&L for formwork fair finished surfaces to chajjas, troughs and similar items including edges all as specified & directed by Engineer in Charge. |
| 24 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 25 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridge, fixed with self tapping screws, complete all as specified and directed. |
| 26 | S&F 25 mm thick 2nd class hard wood boarding with nails in any situation (Except flooring and skirting) complete all as specified and directed by Engr-in-Charge |
| 27 | M&L for false ceiling with 'E' board \\"Classic\\", reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on anodised aluminium snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides including hanging arrangements complete all as specified and as directed |
| 28 | M&L for 1st quality Joint free Non-skid Ceramic tiles 7mm to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm screed bed in CM (1:6) all as specified & directed by Engineer in Charge. |
| 29 | M&L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed. |
| 30 | M&L for coloured Non-skid ceramic tiles 7mm to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. premium quality set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed or bedding layers in cement mortar (1:4) complete all as specified and directed. |
| 31 | M&L for colured Virified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed. |
| 32 | M&L for colour glazed ceramic coloured tiles 350mmx250mmx7mm/ 450x350x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc to match with and including 10mm thick screed bed or backing layers in cement mortar (1:3) complete all as specified and directed. |
| 33 | M&L for Coloured rubber moulded Chequred cement concrete tiles 300 x 300 x 25mm thick, set, jointed and pointed in grey cement mixed with pigments in floors, over 20mm screed bed in CM 1:6, complete all as specified and directed. |
| 34 | M&L for rendering 5mm thick on concrete ceiling surfaces in cement mortar 1:3 finished surfaces fair and even complete all as specified and directed. |
| 35 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM (1:6) finished even and smooth without using extra cement all as directed by Engineer in Charge. |
| 36 | M&L for rendering 15mm thick on fair faces of brick or concrete wall surfaces in cement mortar 1:4 finished surfaces fair & even using WPC (Water Proofing Compound) as per manufacturers instructions complete all as specified and directed.Note : WPC measured and paid separately. |
| 37 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 38 | M&L for preparation for new wooden untreated surfaces of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as per directed. |
| 39 | Solid PVC Wall Lining consisting of 5mm thick wood grain PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing. |
| 40 | M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 41 | M&L for preparation of newly plastered wall surfaces and applying two coats of Oil Bound Distemper over a coat of chalk whiting (preparatory to distemper) applied over 1 to 2 mm thick BIRLA/ JK (or equivalent) water-proof wall care putty complete all as specified and directed by Engineer -in-Charge. |
| 42 | Material & Labour for Preparing new plastered or unplastered surfaces and applying Two coats of 100% Premium acrylic emulsion paint (camouflage pattern) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 43 | M&L for three coats of white wash to newly plastered surface of ceiling incl preparation of surfaces complete all as specified and directed. |
| 44 | M&L for complete removal of existing treatment of old wall surface and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 2mm to 3mm thick BIRLA/JK water proof wall care putty complete all as directed by Engr-in-charge. |
| 45 | M&L for TMT steel bars 10mm dia and over to length bent to shape required, incl cranking bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed by Engineer in Charge. |
| 46 | All as per item no 45.00 here in above but 5mm dia & over upto and incl 10mm dia in stirrups, spacers and binders. |
| 47 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated), Corner striker, Secondary Strikers, Cylinder. Door transmission gear made of mild steel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated). Note: The unit rate quoted by contractor includes all other connected accessories. |
| 48 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: The unit rate quoted by contractor includes all other connected accessories. (A) Area not exceeding 2.00 sqm each |
| 49 | S&F for Anodised aluminium grill (Min thickness 5.2mm and of 2.4Kg/Sqm weight) of approved design/ pattern, with approved standrad section and fixed to existing window frame with CP brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in charge. |
| 50 | S&F of Aluminium Mortice lock, vertical type of size 75 mm, 4 lever, complete all as specified and as directed by Engineer-in-Charge. |
| 51 | Supply & fixing 5.5 thick sheet glass, ordinary quality in square exc 0.5m in each pane complete all as specified and directed. |
| 52 | S&F 1000 Litres Capacity, HDPE (Double layered ISI marked) Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, Complete all as specified and directed. |
| 53 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs concrete floor finishing complete all as specified and as directed. |
| 54 | S&F 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball (Minimum weight 455 gms), complete all as specified and directed. |
| 55 | M&L for 20 mm dia Gate valves with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed. |
| 56 | S&F CPVC 16mm bore, SDR -11 Grade for hot and cold water with all fittings fixed complete to walls and ceilings or laid in floors all as directed by Engineer in Charge. |
| 57 | S&F CPVC 20 mm bore, SDR -11 Grade for hot and cold water with all fittings fixed complete to walls and ceilings or laid in floors all as directed by Engineer in Charge. |
| 58 | M&L for vitreous china wash down water closet pan (pedestal pattern), including Plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device (excluding fixing bolts, flushing cistern and flush pipe) all as directed by Engineer in Charge. |
| 59 | S&F squatting pan vitreous china orrisa pattern of Size 580mmx440mm \\"white\\" with integral foot rest (Excluding flushing cistern and flush pipe) including provision of cement concrete bedding, connection to trap and to flushing pipe, anti-syphonage pipe etc and making good to floor complete all as specified and directed by Engr-in-Charge. |
| 60 | S&F PVC valveless, syphonic action type flushing cistern 10ltr capacity low level white with inlet ball valve float and handle including brackets, Flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern, all as specified and directed. |
| 61 | S & F for PVC Health faucet with all accessories, complete all as specified and directed. |
| 62 | S & F bip taps 15mm chromium plated cast copper alloy with crutch or butterfly handle, screw down for iron pipe or for brass ferrule all as specified & directed by Engineer in Charge |
| 63 | M & L for vitreous china wash basin of size 630 x 450mm, white, flat back, including brackets , 15mm bore pillar taps chromium plated, 32mm bore dia Waste coupling of PTMT (half or full threaded) , cutting for and pinning in ends of brackets or erecting stand, complete all as specified and directed. |
| 64 | S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed. |
| 65 | S&F in repairs in repairs Soap dish, viterous china white approximate size 160X160X90mm complete all as specified & directed |
| 66 | S&F for tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed. |
| 67 | S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified. |
| 68 | S&F 15mm dia stop valves, fancy type chromium plated, cast copper alloy, screwed down , high pressure, with crutch or butterfly handle , screwed both ends for iron pipe or for unions, complete all as specified and directed. |
| 69 | S&F PVC connections 15mm size with PTMT nuts of length 450mm , complete all as specified and directed. |
| 70 | M&L for PVC floor trap, 75 mm dia, with grating including jointing with solvent cement, complete all as specified and directed. |
| 71 | S&F 32 mm bore (LDPE) pipes of pressure rating 6 kg/sqcm, in waste pipe of WHB / Sink, fixed complete to walls, ceiling or in floors etc all as specified and directed. |
| 72 | S&F PVC 75mm (SWR ) pipe single socketed in any length with rubbering joints fixed to walls, complete all as specified and directed. |
| 73 | S&F PVC (SWR) bend 75mm bore any radius complete all as specified and directed. |
| 74 | S&F 110mm bore PVC (SWR ) pipe single socketed in any length with rubbering joints fixed to walls including removal of old damaged PVC pipe, complete all as specified and directed. |
| 75 | S&F PVC (SWR) bend 110mm bore any radius all as specified and directed. |
| 76 | M&L for cutting chases for concealed water tubing or concealed conduit wiring pipe where making good to facing required and pointing in cement mortar 1:3 etc. in Brick wall and concrete. Walls & cutting not exceeding 10 cm girth complete all as specified and directed. |
| 77 | M&L for applying water proofing treatment with the following complete all as specified & directed :-(a) First coat of hot blown bitumen with bitumen 85/25 grade @1.20 Kg/Sqm over bitumen primer @0.3 litre/Sqm.(b) Second layer of APP based polymeric membrane minimum weight 3.5 Kg/Sqm and minimum 3.0mm thick reinforced with polyster non woven fabric (wt not less than 160 gms/Sqm) laid on primed surface by torched application.(c) Third layer i.e. a coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm shall be applied over water proofing membrane. |
| 78 | M&L for rendering 10mm thick cement mortar 1:4 on concrete surfaces as in roof treatment using WPC @3% by weight even & smooth without using extra cement complete all as specified and directed. Note : WPC measured and paid separately. |
| 79 | Taking down of chowkat with shutter without taking off shutters from the frame exceeding 1.5sqm each but not exceeding 4 sqm all as specified and as directed. |
| 80 | Taking down of shutters of any description exceeding 1sqm each and not exceeding 2 Sqm each all as specified and as directed. |
| 81 | S&F factory made solid PVC door frame of size 50 mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with mild steel square tube in opening as per specification and drawing complete all as specified and directed. |
| 82 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, Paneling of plain colour PVC sheet to be fitted in the MS frame welded/ scaled to the stiles and rails with suitable PVC Sheet beading and jointed together with solvent cement as per drawings and specifications complete all as specified and directed. |
| 83 | S&F butt hinge, medium weight, cold rolled mild steel 100mm long all as specified and as directed. |
| 84 | S&F butt hinges, medium weight, cold rolled mild steel 75mm long all as specified and as directed. |
| 85 | S&F aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy 300 mm long and fixed all as specified and as directed. |
| 86 | S&F floor door stopper of aluminium alloy body double and tongue anodised with rubber shoe and fixed of size 150 mm all as specified and as directed. |
| 87 | S&F aluminium anodised barred tower bolt of extruded section 200 mm long and fixed all as specified and as directed. |
| 88 | All as per item No 87.00 here in above but 150mm long |
| 89 | S&F extruded aluminium alloy handle fabricated type anodised 150 mm long. |
| 90 | Dismantling of plain or coorugated steel sheeting any guage, thickness similar pattern in roof covering complete all as specified and directed. |
| 91 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar in 150 mm internal dia complete all as specified and as directed. |
| 92 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar in 100mm internal dia complete all as specified and as directed. |
| 93 | Dismantling of 100 mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and as directed by the Engineer-in-Charge. |
| 94 | Dismantling of 150 mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and as directed by the Engineer-in-Charge. |
| 95 | M&L for concrete bed to drain pipes of size 150 mm bore packingunder and haunching against the sides of pipes after theyare laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed. |
| 96 | M&L for PCC 1:2:4, Type B–0, using 12.5 mm graded stone aggregate as in coping including use and waste of formwork and finishing the exposed faces of concrete even and smooth without using extra cement complete all asspecified and as directed. |
| 97 | M&L for PCC 1:2:4 type B2 (using 40mm graded stone aggregateas in surface channels/benching and drains complete all as specified and directed. |
| 98 | M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded stne aggegate as in plinth protection, surface finished even and smooth complete all as secified & directed by Engineer in Charge. |
| 99 | M&L for Precast RCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, Chajjas, water troughs, Shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed. |
| 100 | M&L for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars, complete all as specified and directed. |
| 101 | M&L for cutting into existing manholes for connecting new drains of Internal dia of pipe in 150 mm , making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required. |
| 102 | Material and labour for Point wiring with 1.5 Sqmm FR PVC insulated and sheathed multi stranded (FRLSH) copper conductor cable in and incl rigid PVC conduit concealed with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness hylum laminated sheet, cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable as earth wire (green colour) to common earth dolly complete all as specified and directed by Engr-in-charge. Note: (a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed |
| 103 | All as per serial item No 102.00 here in before but for one 3 pin 5 Amp socket outlet on independent board. |
| 104 | All as per serial item No 102.00 here in before but for one 3 pin 5 Amp socket outlet on same board. Please Enable Macros to View BoQ information |
| 105 | All as per serial item No 102.00 here in before but for one 3 pin 5 Amp socket outlet on same board. Please Enable Macros to View BoQ information |