| 1 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction withframe of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:30 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 2 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) 300x16 mm |
| 3 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378)250x10 mm |
| 4 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378)125 mm |
| 5 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 6 | Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of:G.S. Sheet |
| 7 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 8 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 10 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 11 | Providing and fixing plain multipurpose cement board(Hight pressuresteam cured) with suitable screws for cement particle board in ceilingetc. complete (frame work to be paid seperatately).6 mm thick Cement fiber board as per IS: 14862 |
| 12 | Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick |
| 15 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 16 | Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty:Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) |
| 17 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 19 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :Two coats |
| 20 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 21 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall15 mm dia nominal bore |
| 22 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : |
| 23 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 24 | Providing and fixing 3mm G.I wire mesh 30x30mm square incuding all complete fittings as per direction of Engineer-In-Charge |
| 25 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 26 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch |
| 27 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as 3 pin 5/6 A socket outlet |
| 28 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 29 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 31 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 32 | Providing and installation of 20 watt Led tube light with all complete fittings as per direction engineer-in-charge |
| 33 | Supplying and installation of 1200mm sweep ceiling fan suitable for operation on 230 volt single phase 50HZ Ac supply incuding 300 mm rod and resistent regulator |
| 34 | Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required.(12 Module) |
| 35 | S/F of 2 core 10 Sq.mmcable(Finolex/Plaza/Crompton/KEI/ ) make or equivalent I/C connections etc as required. Please Enable Macros to View BoQ information |