| 1 | Providing and fixing flush door shutter of solid core melamine face three layered, prelaminated wood based particle board exterior grade having shade of choice on both sides (PTX) or having shade of choice on one side and balancing lamination on the other side (PLX) as per IS 3087 (1985) type I on the edge of Novopan or equivalent bonded with BWR/BWP synthetic resin with second class teak wood, lipping of section of size 12 mm x 30 mm flange and 18 mm x 10 mm web (18 mm deep) fixed into 18 x 10 mm groves of shutter with water resistant adhesive and fully threaded G.I. screws 50 mm not more than 450 mm centre to centre including anodized aluminum butt hinges with necessary screws etc. complete. (b) Natural teak on both faces: 2) 30 mm thick |
| 2 | Providing FRP door shutters 35mm thick with frame size in clear opening of 0.75x2.10m hinges and screws complete., |
| 3 | Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size.b) 40 x 3 mm flat iron hold fast, 15 cm long |
| 4 | Providing & fixing chromium plated brass tower bolts (barrel type) with necessary screws complete. (c)150 x 10 mm |
| 5 | Providing and fixing chromium plated brass handle with necessary screws etc. complete (b) 100 mm |
| 6 | Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 7 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 8 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 9 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 10 | Painting one or more coats of acryllic exterior paint of approved brand and manufacture(Such as Dulex/ Asian Paints/ Sherwin Willians) on old work including cleaning the surface with water etc. complete. |
| 11 | Applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete. |
| 12 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for wood work of approved brand & manufacture in all shades on new work to give an even shade. |
| 13 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade |
| 14 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 15 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 16 | Providing and fixing normal gauge polythene pipes of approved quality complete with special flange compression type fitting (of approved make) including trenching ad refilling etc (external work) (high density): 25 mm nominal bore. |
| 17 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 18 | Providing and fixing Prince or equivalent make PVC SWR half round eaves gutter with bolts, nuts and flat iron brackets 40 x 3 mm size complete b) 180 mm nominal size |
| 19 | Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 20 | Add for providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth above 610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 21 | Supplying and installation of 1 HP Submersible Pump KOS 134NKIRL. |
| 22 | Desilting of the existing Gutters including removing and refixing the precast RCC drain cover slab of thickness 10cms including the required cement mortar in propose 1:4 (1cement :4 time sand )for refixing and disposal of material upto 5kms. |
| 23 | Providing & fixing rotating gate of size 0.90 x 1.00 M with 4 fins of size 0.40 x 1.00 M of G.I. pipe with 40mm dia main pipe of height 1.3m and 25mm dia pipe for fins including excavation, PCC 1:2:4 of size 0.5 x 0.5 x 1.00m, welding, priming coat with ready mixed primer of approved brand and two or more coats with superior quality ready mixed paint of approved brand & manufacture in all shades etc complete. Please Enable Macros to View BoQ information |