| 1 | False ceiling: Providing and Fixing in position Suspended false ceiling system using 600 x 600mm Calcium Silicate Ceiling tiles (AEROLITEceiling systems - Cosmos / Spintone / Hexa / Quadra Models) Tiles having 15mm densified edges and 100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC and approvred surface design and edge profile (TEGULAR/ SPINTONE) placed in a suspended grid of size of 600 x 600mm made of hot-dipped G.I steel sections having an exposed surface capping of pre-finished baked polyester painted coil wherein the main tee of size 24mm x 38mm x 0.33mm shall be suspended at 1200 mm centres along the length of ceiling with 4mm dia G.I wire with necessary level adjusters and cross tees of size 24 x 28 x 0.33mm x 1200 mm shall be inserted in to slots between the main tees at 600mm centres and thereafter in direction vertical to the longer tees, cross tees of size 24 x 28 x 0.33mm x 600mm shall be inserted to form a grid size of 600 x 600 mm resting on the perifery walls on wall angles of size 20mm x 20mm x 3000 mm x 0.40 mm thickness.The rate shall include providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings. The work shall be carried out as per directions of Engineer-in-charge. The main tees to be suspended from the ceiling/ soffit with the help of matal dash fastners of 6mmx50mm, soffit clits of 25mmx35xxx1.60mm and 4mm dia G.I wire with galvanised spring steel levelling clips. the entire grid system shall be designed to bear a distributed load of minimum 15 kg/Sq.m(Only calcium silicate false ceiling area will be measured for the purpose of payment). |
| 2 | False ceiling: Providing and fixing in position suspended seamless false ceiling system using 12.50 mm thick moisture resistant plain gypsumboard ( GYPROC.MR of M/s .Saint Gobain make) suspended ceiling, which includes Gypsteel ULTRA™ CRP surface ribbed perimeter channels (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending Gypsteel ULTRA™ CRP surface ribbed intermediate channels of size 45mm (with two flanges of 15mm each) from the soffit at 1220mm centres with Gypsteel ULTRA™ CRP surface ribbed ceiling angle of width 25mmx10mm fixed to soffit with GI cleat and steel expansion fasteners (Mfg by Ms Saint Gobain Gyproc)Gypsteel ULTRA™ CRP surface ribbed Ceiling section of having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the Gypsteel ULTRA™ intermediate channel with the help of connecting clip and in direction perpendicular to the Gypsteel intermediate™ channel at 457.5mm centres. Single layer of 12.5mm tapered edge Gyproc® MR (conforming to BS 1230 part 1) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc jointing compound, Gyproc joint paper tape and two coats of drywall top coat (as per recommended practices of M/s Saint- Gobain Gyproc India) |
| 3 | False flooring: Providing , supplying and fixing False Flooring of height up to 400mm height in 600 x 600 mm panels fabricated out of CRCA sheets infilled with cementitious fillers and top surface with 1.50 mm Anti Static lamination of 1.50 mm thickness from the Specilized approved manufacturers of capacity of 1350 Kgs/sqm UDL and 450 Kgs Point Load with required supports at floor and walls complete as per drawings and as directed at site .(False flooring system to be got approved by the Engineer in charge before procurement) |
| 4 | False flooring: Providing , supplying and fixing False Flooring of height up to 1000mm height in 600 x 600 mm panels fabricated out of CRCA sheets infilled with cementitious fillers and top surface with 1.50 mm Anti Static lamination of 1.50 mm thickness from the Specilized approved manufacturers of capacity of 1350 Kgs/sqm UDL and 450 Kgs Point Load with required supports at floor and walls complete as per drawings and as directed at site .(False flooring system to be got approved by the Engineer in charge before procurement) |
| 5 | Providing and fixing anodized aluminium work (Anodised Aluminium sections of Minimum anodizing thickness of 15micron) for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete asper drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (fittings glazing and panelling shall be paid for separately) |
| 6 | Providing and fixing glazing in aluminium doors, window, ventilatorshutters and partitions etc with With clear float glass panes of 5.00 mm thickness and PVC / Neoprene gasket etc.complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item) |
| 7 | Providing and fixing anodised aluminium tower bolts of size 300 X 12 mm (barrel type) ISI marked of approved make transparent or dyed to requried colour or shade with necessary screws etc.all as per specifications and as per drawings. |
| 8 | Providing and fixing 4 Lever Mortice Lock of approved make suitable for aluminium sections |
| 9 | Providing and fixing double action hydraulic floor spring of approved brand and manufacturer (conforming to relevant Indian Standard) for doors including cost of cutting floors as required, embedding in floors and cover plates with M.S pivot and single piece of M.S sheet outer box with slide plate etc. complete as per directions of Engineer-in-charge with brass cover plate |
| 10 | Providing, Supplying and fixing 120 Minutes Fire Resistance Gypsum Drywall Partition with overall thickness of approximately 95 to 102 mm thick Gypsteel Ultra stud partition which includes two layers of tapered edge 12.5 mm thick Gyproc Fireline on both sides (conforming to IS:2095 – 1996-Part-I) is screw fixed with drywall screws of 25 mm & 35 mm at 300 mm centres to either side of 70 mm Gypsteel Ultra C stud (0.5 mm thick having one flange of 34 mm and another flange of 36 mm made of GI Steel) placed at 610 mm centre to centre in 72 mm Gypsteel Ultra floor and ceiling channel (0.5 mm thick have equal flanges of 32mm made of GI steel), which is anchored to the floor & true ceiling using suitable anchor fasteners. The boards are to be fixed to the framework with joints staggered to avoid leakage through joints. A Gypsteel fixing channel of 99mm width (0.9 mm thick having two flanges of 9.5 mm each) has to be provided at the horizontal joints of the outer layer of boards screw fixed to the studs using metal to metal flat head screws.Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc Jointing compound, Gyproc Joint Paper tape and two coats of Drywall Top Coat (as per recommended practices of Saint- Gobain Gyproc India) . The junction of the partition with masonry & all penetration through the partition has to be treated with a intumescent fire sealant of equivalent fire rating. 25mm glasswool slab of density 32Kg/m3 shall be provided in the cavity. |
| 11 | Supply and Installation of Flameproof Exhaust fan 18\\" single phase fitted with FLP motor 0.33.HP 1440 RPM Single phase. Complete Fan shall be Certified by CIMFR, Dhanbad for Zone 1 & 2, 21 & 22 Gas group IIA & IIB, IIC, BIS and PESO as per IS / IEC 60079-1:2014. Cat.No.EF/140.Suggested makes: M/s Sudhir switchgear, M/s Prateek explosion proof, M/s FCG, M/s Crompton Greeves |
| 12 | Supply of Hydrogen Detector along with required interfacemodule and all required accessories.Detector shall be of conventional Gas Detector 3 Wire for detection of hydrogen gas leakage. Range shall be from 0 to 100% LEL. Sensor principle shall be of Catalytic bead and detection Method shall be Natural Diffusion. Detector standard Output1 shall be 4-20mA Current Output and Output 2 shall be Two SPDT Relays of rating ‘5A’.UNIQUE SPECIFICATION: -Detector shall be Certified by CIMFR, BIS, PESO Tested Enclosure. No third party Enclosure shall be used. Enclosure protection class shall be IP-66. Display shall be of 4-Digit 8 mm (H) 7-Segment LED Display. It shall be optimised for detection of smallest Gas leaks. Detector shall be highly resistant to poisoning & etching. Detector shall have 4 LEDs to Indicate Status of Instrument.GENERAL SPECIFICATION: -Supply Voltage: 18 To 36V DC Typically 24V DC. Necessary SMPS shall be supplied along with each detector. And wiring between nearest power point available at site to SMPS and from SMPS to detector is also in the scope of this item. Enclosure material shall be Cast Alluminium alloy LM-6 Powder coating of Marine Blue, Exd IIC T6 Gb as per IS IEC 60079-0 & IS IEC 60079-1. Sensor housing shall be SS 316. Shall be compatible for Mounting on Wall / Stand / Pipe Mounting. It shall operate between -15 to +55 °C temperature. |
| 13 | SITC of 40W flameproof lights suitable for Gas group Ex.d IIA & IIB, with ingress protection IP 65. Material of construction shall be pressure die cast aluminium alloy. Temperature class shall be T6. Hardware material shall be Stainless steel. Minimum lumen output shall be 4000lm./ CCT and CRI shall be 6500 and 80% respectively. Operating voltage is 220-240V AC 50 Hz.Suggested makes: M/s Sudhir switchgear, M/s Prateek explosion proof, M/s FCG, M/s Crompton Greeves |
| 14 | SITC of Flameproof/Weatherproof IP66 Switch Socket with Termination Box in cast alluminium alloy construction suitable for Rating 16A DP with 2P+E Plug Top. It shall be Certified by CIMFR, Dhanbad for Zone 1 & 2, 21 & 22 Gas group IIA & IIB,IIC, BIS and PESO as per IS / IEC 60079-1:2014. Supply Voltage is 220-240V AC 50Hz. Number of cable entries shall be 2 Nos. of size M20 at Bottom & 1No of M20 from plug top. Suggested makes: M/s Sudhir switchgear, M/s Prateek explosion proof, M/s FCG, M/s Crompton Greeves |
| 15 | SITC of 3CX2.5 Sqmm Cu conductor XLPE insulated PVC ST2 innersheather, wire/flat armoured, PVC FLES outersheathed cable as per IS 7098.Suggested makes: M/s Polycab, M/s Gloster, M/s Gemscab, M/s APAR, M/s KEI, M/s Havells, M/s Finolex, M/s RR kabel. |
| 16 | End termination of 3CX2.5 Sqmm armoured cable with single compression brass metal gland including gland earthing, copper lugs, ferruling etc as per the direction of EIC. |
| 17 | Making cutout in brickwall of size approaximately 600mm*600mm for installation of exhaust fans and finshing with plastering and paint |
| 18 | Supply & Installation of 750mm ladder type hot dip galvanised cable tray having 86 micron galvanisation thickness. Thickness of cable tray shall be 2 mm (tolerance applicable as per IS 1852). Height of the tray shall be 50mm. Centre to Centre distance between rungs shall be 250mm. Side channel and cross rung dimensions shall be 50mmX15mm and 35mmX15mm respectively. Cable tray shall be supplied along with all accessories like Coupler plates, nuts and bolts etc as per site requirement. Suggested makes are M/s Indiana, M/s Asian Anciliary, M/s Metalemn, M/s Profab. |
| 19 | SITC of 1.5 ton 5 star Airconditioner including all equipment like compressor, condenser, expansion device, fan & motor etc. with copper coil, capacitor of metallic canister with explosion proof feature to be provided. An analog time switch with daily program to be provided in powder coated enclosure with 20A 230V 3 pin metal clad socket and plug, 20A isolator. Stabiliser of 230V 50Hz suitable for 1.5ton AC shall also be provided. Manufacutring year of AC shal be 2024/2025/2026. Refrigerant shall be R32/R410A/R-134A/R290/R600A. Power wiring between socket and indoor unit, power wiring between indoor and outdoor unit, wiring for timer to AC, plug top, cordless remote microprocessor is to be included in the scope of work. PVC trunking for covering refrigerant pipe of length as per site conditions shall be provided. Powder coated MS support for ODU shall be provided. Scope of installation including marking holes on wall for piping by core cutting, sealing, extra length of insulated refrigerant pipe without joints is also scope of this item. Functional test and effectiveness of cooling shall be ensured. Work shall be carried out as perr the directions of EIC.Suggested makes: M/s Voltas, M/s Carrier, M/s Bluestar, M/s Daikin Please Enable Macros to View BoQ information |