| 1 | Earth work in excavation for structure as per drawing and technical specification clause 305.1 I/c setting out ,construction of shoring and bracing removal of stums and other deletarious materials and disposal upto a lead of 50 metre, dressing of sides and bottom and back filling in tranches with excavated suitable material. |
| 2 | P/L Cement concrete 1:6:12 ( one cement : six sand : twelve graded stone aggregate forty millimeter nominal size)for plain/ reinforced concrete work in open foundation complete as per drawing and technical specification Clauses 802,803,1202& 1203. |
| 3 | Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification clause 802,803,1202 & 1203. P.C.C. M-10 grade (1:3:6) ( For Sub Structure) |
| 4 | Providind concrete for plain/reinforced concrete in sub structure complete as per drawing and technical specification clause 802,804 805, 806,807,1202 & 1204. Nominal mix RCC/P.C.C. M-20 ( C.C. 1:2:4 ) |
| 5 | Providing and laying reinforced cement concrete M-20 in super structure as per drawings and technical specification clause 802,804,805,806,807,1202& 1204. |
| 6 | Providing and laying reinforced cement concrete M-30 in super structure as per drawings and technical specification clause 802,804,805,806,807,1202& 1204. |
| 7 | Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification clause 802,803,1202 & 1203. P.C.C. M-10 grade (1:3:6) ( For Sub Structure) |
| 8 | Supplying fitting and placing HYSD bar reinforcement in super structure complete as per clause 1002, 1010 & 1202. |
| 9 | Providing weepholes in brick masonry/stone masonry/plain reinforced conrete abutment,wing wall, return wall with 100 mm dia. PVC pipe extending through the full width of the structures with slope of 1(v) : 20 (H) towards drawing face complete as per drawing and technical specification clauses 614,709,1204.3.7. |
| 10 | Drainage spout complete as per drawing and technical specification clause 1209. |
| 11 | Back filling behind abutment,wing wall and return wall complete as per drawing and technical specification clause 1204.3.8 granular material. |
| 12 | Stone soling properly hand-packed filling interstices with Kharanja stone and consolidating with power road roller to the requested gradient and comber including spreading watering and rolling of binding materials moorum or earth etc. complete as per HP.PWD specification. 100 mm spread thickness (finished work including materials and labour) Please Enable Macros to View BoQ information |