| 1 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed |
| 2 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 sqm but n.exc 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 3 | Vitrified coloured double / ultra charge tiles 8-10mm thick (square / rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 4 | All as per serial item No 03 herein before but on vertical surfaces as skirting and dado over 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 5 | Vitrified coloured double / ultra charge tiles 8-10mm thick (square / rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 6 | All as per serial item No 04 herein before but on vertical surfaces as skirting and dado over 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 7 | Glazed coloured ceramic tiles in vertical surface 3000mm x 450mm x 7mm thick , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 8 | 16-18mm thick Granite work (of any type table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in, set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling of existing stone slab compelte all as specified and directed. |
| 9 | Rounding of / moulding to edges of stone of any description including rubbing and polishing (Granite finish) complete all as specified and directed. |
| 10 | Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed. |
| 11 | Taking down chowkats or frame n.exc. 1.5 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 12 | Taking down chowkats or frame exc. 1.5 sqm and n exc 4 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 13 | 35mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides all as specified & directed by Engineer-in-charge. |
| 14 | Butt hinges, cold rolled stainless steel medium weight 100mm long complete all as specified & directed. |
| 15 | 200mm aluminum anodized barrel tower bolts (ISI Marked) of extruded section, complete all as specified and directed. |
| 16 | Aluminum alloy, anodized, sliding door bolt (ISI Marked),250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed, as in repair complete all as specified and directed. |
| 17 | 150 mm aluminium handles cast type anodized complete all as specified and directed. |
| 18 | Door closer hydraulically regulated of aluminium extruded section, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, fixed as in repair complete all as specified and directed. |
| 19 | Hacking out old broken glass ( any thickness) size quality etc from metal frames fixed with pin, beading or oil putty complete all as specified and directed. |
| 20 | 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty ( or beading ) in square n.exc 0.5 Sqm in each panes complete all as specified and directed. |
| 21 | 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 22 | Providing wooden laminated flooring with bruce locking system having surface abrasion class AC-3 and density 920 Kg per Cum, of size 1215mm x 194mm x 8mm thick having fire rating class B1, fixed as in repair complete all as specified and directed. MAKE : ARMSTRONG /VISTA/PERGO |
| 23 | False ceiling ,with powder coated exposed Gl grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exc 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmx600mm. Grid of modular size 600mm x600 mm shall be supported by 4mm dia Gl wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fibre cement designer ceiling board (Density>1200 Kg/Cum) of size 595mmx 595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per IS 1530 part 3 & BS-476 Part-4, 5, 6,7 & 8, fixed as in repair complete all as per manufacturer's instruction. |
| 24 | 4mm thick high pressure steam cured non asbestos fibre cement designer ceiling board (Density>1200 Kg/Cum) of size 595mmx 595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per IS 1530 part 3 & BS-476 Part-4, 5, 6,7 & 8, fixed as in repair complete all as per manufacturer's instruction. |
| 25 | Double action floor spring heavy load of size 300mm x 200mm hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. |
| 26 | Cleaning of 04 Nos windows (set of 4 Nos) complete glass window of size 2.75x2.10 m of each window) at a height of 35 to 40 mtr from outside the bldg including all necessary chain pulley or scaffolding to the external faceand safety arrangements ,manually or mechanically with washing chemicals etc compete all as specied and directed |
| 27 | Powder coated aluminium door frame of hollow section 65x40mm and including aluminium glazed shutters stiles 95x45mm & having grooves for bush beading and top rail of hollow section 80x45mm . Lock rail of hallow section 115x45mm and bottom rail of hollow section 125x45mm with aluminium butt hinges of size 125mm, aluminium anodised handle 200mm long and aluminium floor door stopper, hydraulic door closer mortise lock 65mm,4 leivers and aluminium and glazing with selected quality tinted glass 5 mm thick and rubber beading and aluminium beading and PVC bush beading complete all as directed(Note- Thickness of aluminium section not less than 1.58mm).” complete all as specified and directed. |
| 28 | Fabrication powder coated aluminium air tight sliding type window with AI box frame 65 x35x2 mm shutter with bottom and top rails of section 45x45x2 with 5mm thick selected quality tinted glass pan including rebated fixing builder hard ware and fitting springs, glazing clips rubber packing for air locking, anodised AI snap beading screw etc for fixing glass pane in frame shutters cover selected quality glass 5mm thick rubber packing including aluminium grill of size 75x75 mm cast type with aluminium beading, gasket etc complete and stailess steel wire mesh complete all as specified and directed. |
| 29 | Providing and fixing factory made uPVC coloured sliding window Three track, area not excedding 2 sqm each made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2mm, 0.2mm thick galvanised steel Frame of size (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. |
| 30 | Solid 14mm thick wood polymer composite louvers wall paneling (size 192mm x 2900mm x 14mm) fixed to walls with necessary clip, screw / adhesive complete all as specified and directed.NOTE : The wall paneling has to be in conformity with the existing wall paneling at site. Bidders are requestd to visit the site before quoting their bid. |
| 31 | 2mm thik PVC sheet fillet/ angle / beading of width 35mm for making frame for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing , complete all as specified and directed at site. |
| 32 | Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete, all as specified and directed. |
| 33 | 15mm thick rendering in Cement and Sand mortar 1:4 mixed with WPC over roof slab and parapets, walls etc finished even and fair without using extra cement all as specified and directed.Note : WPC will be measured and paid separately. |
| 34 | Rendering 15mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 35 | Supply only integral water proofing compound complete all as specified & directed. |
| 36 | Demolition of reinforced cement concrete of any description, in any position not specifically provided for, complete all as specified and directed. |
| 37 | Reinforced cement concrete, type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, balconies, roofs, canopies shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 38 | Form work to soffits of suspended slabs such as roof slabs rough finished surface of concrete flat not exc 200mm thick complete all as specified and directed. |
| 39 | Mild steel TMT bars 10mm dia and over ,cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed. |
| 40 | Demolition of brickwork built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed |
| 41 | Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 42 | Preparation of old decorated wall surfaces by removing spoiled paint/scale dirt with wire brush or mechanical means/grinder including washing rubbing and Applying wall care putty interior grade in two coats smoothening the surfaces with sand papers and applying coat of wall primer and two coats of plastic emulsion on wall surfaces complete all as specified. |
| 43 | Preparation of old decorated wall surfaces by removing spoiled paint/scale dirt with wire brush or mechanical means/grinder including washing rubbing the surfaces and applying two coats of exterior emulsion paint as per manufacturer instruction complete all as specified and directed. |
| 44 | Preparing old decorated wall surfaces and applying One coat of exterior emulsion paint complete all as specified and directed. |
| 45 | Preparation of new plastered surface of wall sand applying two coats of exterior emulsion paint over and including one coat of exterior primer as per manufacturer instruction complete all as specified and directed. |
| 46 | Preparation of old plastered wall / ceiling surfaces and applying One coat of plastic emulsion using hand roller complete all as specified. |
| 47 | Preparation of old plastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and directed. |
| 48 | Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over and including a coat of primer complete all as specified and directed. |
| 49 | One coat of oil bound on old decorated ceiling surfaces including preparation of old surfaces complete all as specified and directed |
| 50 | One coat of oil bound on old decorated wall surfaces including preparation of old surfaces complete all as specified and directed |
| 51 | Preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 52 | Preparation of old steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 53 | Preparation of old decorated concrete /stone surfaces of any desciption and applying one coat of synthetic enameled paint complete all as specified & directed. |
| 54 | PVC (SWR) pipe, 160mm bore, single socketed in any length with rubber ring joints, fixed to walls or laid in floor, trenches etc, fixed as in repair complete all as specified and directed. |
| 55 | 160mm bore PVC (SWR) bends of any radius, fixed as in repair complete all as specified and directed. |
| 56 | 10mm thick toughened glass as in hinged doors, partitions ,automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and directed. |
| 57 | Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O, including dismantling all as specified and directed. |
| 58 | Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified & directed. |
| 59 | Precast factory made RCC manhole and drain covers/slab of size 1200 mm x 600 mm x 100 mm with plain faces, MS frame of not les than 1mm thickness, set in position complete all as specified and directed. Please Enable Macros to View BoQ information |