| 1 | WIRING |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 3 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 4 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 7 | Group C |
| 8 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 9 | 20 mm |
| 10 | 25 mm |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | 5/6 A switch |
| 13 | 15/16 A switch |
| 14 | 3 pin 5/6 A socket outlet |
| 15 | 6 pin 15/16 A socket outlet |
| 16 | 15/16A modular socket Three module |
| 17 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 18 | 1 or 2 Module (75mmX75mm) |
| 19 | 3 Module (100mmX75mm) |
| 20 | 4 Module (125mmX75mm) |
| 21 | 6 Module (200mmX75mm) |
| 22 | MCCB, MCB & DB'S |
| 23 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 24 | 12 way , Double door |
| 25 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Single pole |
| 27 | Double pole |
| 28 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 29 | LED LIGHT |
| 30 | LED Luminaires |
| 31 | Supply and fixing of 1x1or nearest size of 18 W recess mounting type (square type),, 1800 lm, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -LCTLRNE-18-CDL(1X1)) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site. |
| 32 | MISC. Items |
| 33 | Labelling of DB/Switch board with adhesive plastic coated printed labels (3 to 6 letters, maximum 25sq.cm. size) necessory arrangement for fixing on exixting DB/switch board etc. as required. |
| 34 | WALL FAN |
| 35 | Supply and fixing of 450 mm sweep wall mount fan with Aluminium blades, 1350RPM, minimum 100 CCM air delivery Wall mount Fan with necessory arrangement (Crompton Sstorm2 Wall mount or equivalent ) |
| 36 | Removal of Existing Electrical Fittings and Accessories |
| 37 | Removing the existing sub-main wiring including conduits, wires, clamps and all associated accessories, complete as required, and handing over the dismantled materials to the store/yard, as directed by the Engineer-in-Charge. |
| 38 | Removing the existing switchboard of any size including wires, switches (modular/piano type), switchboard plate, clamps, GI/plastic box and all associated accessories, complete as required, and handing over the dismantled materials to the store/yard, as directed by the Engineer-in-Charge. |
| 39 | Removing the existing ceiling fan along with rod, regulator from the switchboard, complete as required, and handing over the dismantled items to the EMU store safely including proper stacking of fan blades, as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |