| 1 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&Pcomplete in all respect as per direction of E/I. UPPWD-2018, PS-647(Make-Bajaj,Transrail,Valmont) |
| 2 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. CAT- AAA Uppwd-1423(make- Havells, LT, Bajaj, Philips K-lite,Neri) |
| 3 | S/L of Al. conductor PVC insulated armoured served sheathed cable 1100 V grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround & protected with bricks on sides & top on surface, the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the E/I. complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. P.S. No. 501 (Grandley, Gloster, Kalinga, Havells, Nicco, Plaza Make) |
| 4 | I) 16 Sqmm x 4 Core |
| 5 | III) 50 Sqmm x 3.5 Core |
| 6 | III) 185 Sqmm x 3.5 Core |
| 7 | Supply and fixing of plain or pin type copper tin plated cable socket (lugs) to the cable leads making connections etc. complete in all respects as pe direction of E/I PS No. 504. |
| 8 | I) 16 Sqmm |
| 9 | III) 50 Sqmm |
| 10 | III) 185 Sqmm |
| 11 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS No 807(d) 15 A TPN |
| 12 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required DSR Electrical 14.16.163 mm dia (OD-63 mm & ID-51 mm nominal) |
| 13 | Analysis of Rates for laying of 90 mm dia DWC (Double Wall Corrugated) pipe across the road by Trenchless Method (Manual) |
| 14 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.PS No-725b (2018) |
| 15 | S/E of overhead line with ACSR (Painther/Dog) Conductor on pole/service bracket including binding etc. complete in all respects PS No 627 |
| 16 | S/E Testing & Commissioning of 250 KVA Copper wound outdoor type Transformer as per ISS. Complete in all respects Make : P.M./Kanohar/LD Power/Paramix as per direction of E/I (UPERC 2019) |
| 17 | Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 |
| 18 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 |
| 19 | S/F of 11 KV pin 12\\" long with insulator of Jai Shree/HBHEL on cross arm fixed on HT pole including all T/P etc UPERC P-39 Annexure-16 |
| 20 | S/F of 11 KV TPMO Relco/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects as per direction of E/I UPERC P-48 |
| 21 | Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 |
| 22 | Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 |
| 23 | Supply of MS T-off Channel 1.15 mtr as per design complete in all respects UPERC P-48 |
| 24 | Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 |
| 25 | Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 |
| 26 | Supply and Fixing of 11 kv Fuse set, 100A, Drop fuse set channel type(3 Nos)(AOR) |
| 27 | 5.5 M.R. Ground Floor MCB for Shops (M.R.) Incoming: 1 no. 150 amps, 35 kA (CS+ICU) TPN MCCB with over current and short circuit release complete with I No. Digital Voltmeter of range O-500V, Selector switch and 2 Amps, SP MCB backup, 1 No, Digital Ammeter of range O-150A, Selector switch and 3 Nos. of associated CT's of ratio 150/5A of a accuracy CL-1.0, 15VA burden, 1 set of phase indicating Temp with 2 Amps, SP MCB backup, Bus bars: Electrolytic high conductivity aluminium three phase and neutral busbars rated at 415V. 50Hz 200 amps, 35kA, insulated with heat shrinkable coloured PVC sleeves& clip on shrouds for joints, Outgoing:-14 nos 40 Amp FP MCBs of 10kA breaking capacity each comprising 3Ph dual type KWH meter, CT of reuired rating, 15 VA class 1.0 indication lamps and toggle switch etc. 2 nos 40 Amp FP MCBs fo 10 kA breaking capacity (2Spare) Ground Floor MDB for shops described as above. |
| 28 | Demolishing R.C.C. Work Manually by mechnical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of E/I. (AOR) |
| 29 | Cement Concrete with 2 cm gauge stone grit, coarse sand & cement in proportion of 4:2:1 including supply of all material, Labour , tools & plants etc. Required for proper completion of work. SOR No. 279(a) |
| 30 | Supply of 120 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV cable neutral earthed system confirming to IS 7098-Part-II(1985) with latest amendment complete in all respects as per direction of E/I. Make: Gloster/Universal/Polycab /Havells. /Dicab, AOR |
| 31 | Laying of One number XLPE Power cable of 11 KV grade of following size in the existing RCC/HUME/METAL/HDPE pipe as required (DSR elect 2018 Item No 8.3.2 /P-44) above 120 sqmm and upto 400 sqmm |
| 32 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (/duraline/EONN Plast/rex/ times make). Please Enable Macros to View BoQ information |