| 1 | Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and as directed. |
| 2 | M&L for point wiring complete with 1.5 Sqmm (nominal area) single core PVC insulated and unsheathed FRLSH multistranded copper conductor cable (maintaining colour code) 1100 volts grade drawn through and including PVC casing caping of adequate size but not less than 20mm in width and 1.2mm thick with all fittings and accossories ISI marked including modular surface box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc and complete with all fittings and accessories fixed to wall/ceiling for the following and making good the disturbed surfaces of wall / ceiling by cement mortar 1:4 including painting to existing surfaces etcwith and including provisining of 1.5 sqmm (nominal area) PVC insulated flame retardant unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor cable green in colour to common earth and connected to earth dolly for the following :- |
| 3 | One light/ Fan point controlled by one no one way switch complete all as specified and as directed. |
| 4 | One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5Sqmm size complete all as specified and as directed. |
| 5 | One 3 pin 5 Amps socket outlet 5/6 Amp on independent board with cable of 1.5 sqmm size. |
| 6 | One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed. |
| 7 | All as per item No.2 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 6 pin 6/16 Amps switch socketcombination on independent board with 2.5 Sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly. |
| 8 | M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit medium grade minimum 20 mm dia ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof and chisselling on wall complete and making good the disturbed surfaces of wall / ceiling by cement mortar 1:4 including painting to existing surfaces etc with sunken type pressed steel/welded MS terminal boxes made out of 1.25 mm MS sheet for mounting of fittings like switch, socket and fan regulator with 3mm thick hylum laminated sheet cover including cutting chases pining in for concealed conduit wiring amd making good of disturbed surface complete for the following srl items :- |
| 9 | One light/fan/ Bell point controlled by one one way switch complete all as specified and as directed. |
| 10 | One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5Sqmm size complete all as specified and as directed. |
| 11 | One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed. |
| 12 | One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed. |
| 13 | All as per item No. 4.00 above but wiring with 2.5sqmm multistranded copper conductor unsheathed and 2.5sqmm copper conductor unsheathed cable as earth continuity conductor for 6 pin 6/16 Amps switch socket combinationon independent board with 2.5 Sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly. |
| 14 | All as per item No. 4.00 above but wiring with 4 sqmm size FRLSH single core copper conductor for 6 pin 6/16 Amps switch socket combinationon independent board with 4 Sqmm FRLSH PVC insulated and unsheathed copper conductor as earth and connected to earth dolly. |
| 15 | Supply and fixing Switch piano flush type single pole one way 5 Amp, complete all as specified & as directed. |
| 16 | Supply and fixing Bell push flush type 5 Amp complete all as specified and as directed. |
| 17 | Supply and fixing switch socket outlet 3 pin, 5/6 Amps, 240 Volts flush type complete all as specified and as directed. |
| 18 | Supply and fixing Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type complete all as specified & as directed. |
| 19 | Supply and fixing Switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp complete all as specified & as directed. |
| 20 | Supply and fixing ceiling rose surface bakelite three terminal 65 x 50 mm 250/230 volts, PVC round block, 6A, pilot 2 plate, ISI marked complete all as specified and as directed. |
| 21 | Supply and fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. |
| 22 | Supply and fixing Fan regulator electronic two module size, flush type 230V complete all as specified & as directed. |
| 23 | Supply and fixing call bell, Ding dong, AC, 230 volt single pole complete all as specified and as directed. |
| 24 | Supply and fixing in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp, 240 volt, 10KA, C series complete all as specified and as directed |
| 25 | M&L for wiring with 2 runs of 1.5 sqmm. single core FRLSH PVC insulated and unsheathed cable confirming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as tees, Elbows, junction box, reducers etc as required alongwith one run of 1.5sqmm single core FRLSH PVC insulated & unsheathed copper conductor as continiuos earth wire dolly and connecting to existing main switch board/ distribution board of each building/ qtr as ordered and testing on completion including taking doiwn old wiring and type of conduit complete all as specified and as directed.NOTE: 2 runs of 1.5 sqmm cables and 1 run of 1.5 sqmm cable alongwith conduit altogether with accessories shall be measured as one unit. |
| 26 | M&L for wiring with 2 runs of 2.5 sqmm. single core FRLSH PVC insulated and unsheathed cable confirming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as tees, Elbows, junction box, reducers etc as required alongwith one run of 2.5sqmm single core FRLSH PVC insulated & unsheathed copper conductor as continiuos earth wire dolly and connecting to existing main switch board/ distribution board of each building/ qtr as ordered and testing on completion including taking doiwn old wiring and type of conduit complete all as specified and as directed.NOTE: 2 runs of 2.5 sqmm cables and 1 run of 2.5 sqmm cable alongwith conduit altogether with accessories shall be measured as one unit. |
| 27 | M&L for sub main wiring with 2 runs of 4 sqmm. single core FRLSH PVC insulated and unsheathed cable confirming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as tees, Elbows, junction box, reducers etc as required alongwith one run of 4.0 sqmm single core FRLSH PVC insulated & unsheathed copper conductor as continiuos earth wire dolly and connecting to existing main switch board/ distribution board of each building/ qtr as ordered and testing on completion including taking doiwn old sub main wiring and type of conduit complete all as specified and as directed.NOTE: 2 runs of 4.0 sqmm cables and 1 run of 4.0 sqmm cable alongwith conduit altogether with accessories shall be measured as one unit. |
| 28 | M&L for sub main wiring with 2 runs of 6 sqmm. single core FRLSH PVC insulated and unsheathed cable confirming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as tees, Elbows, junction box, reducers etc as required alongwith one run of 6.0 sqmm single core FRLSH PVC insulated & unsheathed copper conductor as continiuos earth wire dolly and connecting to existing main switch board/ distribution board of each building/ qtr as ordered and testing on completion including taking doiwn old sub main wiring and type of conduit complete all as specified and as directed.NOTE: 2 runs of 6.0 sqmm cables and 1 run of 6.0 sqmm cable alongwith conduit altogether with accessories shall be measured as one unit. |
| 29 | Supply and fixing as in repair LED tube light fitting, 1x20 watt, 220-240 volt, AC, invertor type with inbuilt rechargeable lithium battery back up for emergency operation, decorative box type complete with LED tube, electronic driver, holder, diffuser and automatic changeover during power failure with minimum of 04 hours battery backup suitable for wall/ceiling mounting including connecting up with three core flexiblwe copper conductor of suitable size from ceiling rose complete all as specified and as directed. |
| 30 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 31 | Supply and fixing in repair/replacement wall mounted decorative luminaire in design mesh suitable for 10W LED lamp B22 base including lamp of LED 10W complete all as specified and as directed. |
| 32 | Supply and fixing as in repair 10W LED Bulkhead light, pressure die cast housing LED bulkhead with IP65 Protection and IK09 Impact resistance suitable for surface/wall mounted,complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 33 | M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc including taking down old earthing complete all as specified and as directed. Note:- Rate quoted by tenderers shall be deemed to include for following provisions-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd .[v]. GI protection pipe of size 15 mm bore light grade 7.5m. |
| 34 | Taking down ceiling fan of 1200/1400 mm sweep, Exhaust fan of 280mm to 450mm, wall mounting fan of 400mm/450mm sweep from existing position, opening and reassembling after repairs/replacement of defective spare parts like bearing, bushing, capacitor, canopy, clamps, blades etc (except rewinding) including cleaning, greasing and refixing in position on same location or other location of any other location of any type/make and size carefully from fan hook and transporting from any location inside army are to MES E/M store yard and back after repairing and connecting with new flexible twin twisted copper conductor wire of size 0.75 sqmm from connector to ceiling fan and testing complete all as specified and as directed. (Note: Spare parts as required shall be measured and paid seperately under relevent items as supply only). |
| 35 | M&L for painting of ceiling fan/ exhaust fan complete with blades in situ with synthetic enamel paint by spraying including cavities with filler with one coat after cleaning all dust etc complete all as specified and as directed. |
| 36 | M&L for Rewinding of ceiling fan of 1200 mm sweep with super enamelled copper wire as per existing gauge including necccessary heating, varnishing etc complete all as specified and as directed. |
| 37 | M&L for Rewinding of ceiling fan of 1400 mm sweep with super enamelled copper wire as per existing gauge including necccessary heating, varnishing etc complete all as specified and as directed. |
| 38 | M&L for Rewinding of exhaust fan of 280 mm/300mm sweep with super enamelled copper wire as per existing gauge including necccessary heating , varnishing etc complete all as specified and as directed. |
| 39 | M&L for Rewinding of exhaust fan of 380 mm/450 mm sweep with super enamelled copper wire as per existing gauge including necccessary heating , varnishing etc complete all as specified and as directed. |
| 40 | M&L for Rewinding of wall mounted fan of 400 mm/450 mm sweep with super enamelled copper wire as per existing gauge including necccessary heating , varnishing etc complete all as specified and as directed. |
| 41 | Supply only fan capacitor 2.50 MFD, 220/240 volts complete all as specified and as directed. |
| 42 | Supply only fan capacitor 3.15 MFD, 220/240 volts complete all as specified and as directed. |
| 43 | Supply only fan capacitor 4 MFD, 220/240 volts complete all as specified and as directed. |
| 44 | Supply only Gun metal bush suitable for ceiling fan/exhaust fan/ wall mounted fan as per existing shape and size complete all as specified and as directed. |
| 45 | Supply only ball bearing NO 6201 for ceiling fan/exhaust fan/ wall mounted fan/ pedestal fan complete all as specified and as directed. |
| 46 | Supply only ball bearing NO 6202 for ceiling fan/exhaust fan/ wall mounted fan/ pedestal fan complete all as specified and as directed. |
| 47 | Supply only plastic fan canopy upper & lower of ceiling fan 1200mm/1400mm sweep fixed with suitable size of screws complete all as specified and as directed. |
| 48 | Supply only fan clamp made of mild steel flat iron (approximate length 5cm to 6cm) suitable for fixing with down rod with 2 nos nuts and bolts of appropriate size, safety pin and locking pin complete all as specified and as directed. |
| 49 | Supply only rubber real (bush) including shackle clamp, bolts, nuts, washers split pins of appropriate size as required of ceiling fan complete all as specified and as directed. |
| 50 | Supply onlydown rod made of 15mm dia GI pipe heavy duty, 45cm long including machining/ threading/ drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and as directed. |
| 51 | S&F in repair ball bearing of size suitable for exhaust fan/ wall mounted upto 400mm sweep complete all as specified and as directed. |
| 52 | Supply and fixing in repair switch piano flush type one way 5/6 Amp, 230 Volts complete all as specified and as directed. |
| 53 | Supply and fixing in repair switch flush type one way 15 Amp, 230 Volts complete all as specified and as directed. |
| 54 | Supply and fixing in repair socket outlet, 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and as directed. |
| 55 | Supply and fixing in repair Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type complete all as specified & as directed. |
| 56 | Supply and fixing in repair Switch socket combination multipurpose, 2 in 1, 3 pin, 5 & 15 Amp complete all as specified & as directed. |
| 57 | Supply and fixing in repair socket outlet, 3 pin, 15 Amp 240 volts complete all as specified & as directed. |
| 58 | Supply and fixing in repair ceiling rose surface bakelite 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and as directed. |
| 59 | Supply and fixing in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting or PVC round or square box complete all as specified and as directed. |
| 60 | Supply and fixing in repair fan regulator electronic two module size, flush type 230V complete all as specified & as directed. |
| 61 | Supply and fixing as in repair Factory made load line Distribution board in sheet steel enclosure vertical DOUBLE door with 200 Amps rated bus bar, TPN, 4 ways, 240 Volts suitable for housing MCCBs as incomer (except MCCB) including cutting chases for sinking boxes complete all as specified and as directed. |
| 62 | Supply and fixing as in repair factory made board distribution in sheet steel enclosure double door glazed with 200 Amps rated bus bar, SPN, 8 ways, 240 Volts suitable for housing MCBs complete all as specified and as directed. |
| 63 | Supply and fixing as in repair MCCB, DB, IP-43 of sheet metal enclosure, double door, VTPN, 4 way with 250 Amp rated copper bus bar, 415 volt complete all as specified and as directed. |
| 64 | Supply and fixing in repair MCB, SP, 240 volts, 'C' Curve, 6 to 32 Amps, 50Hz, 10 KA, in accordance with IS/IEC 60898-1, marked fixing in DBs (ISI marked) complete all as specified and as directed. (Note:- DBs shall be measure and paid seperately under relevant item of schedule). |
| 65 | Supply and fixing in repair MCB, SPN, 240 volts, 'C' Curve, 32 Amps, 50 Hz, 10 KA, in accordance with IS/IEC 60898-1, marked fixing in DBs (ISI marked) complete all as specified and as directed. (Note:- DBs shall be measure and paid seperately under relevant item of schedule). |
| 66 | Supply and fixing in repair MCB, TPN, 415 volts, 'C' Curve, 40 to 100 Amps, 50 Hz, 10 KA, in accordance with IS/IEC 60898-1, marked fixing in DBs (ISI marked) rupturing capacity complete all as specified and as directed. (Note:- DBs shall be measure and paid seperately under relevant item of schedule). |
| 67 | Supply & fixing as in repair, connecting, testing and commissioning of MCCB, 4 Pole, 63 Amps, 415 Volt, AC, 50Hz, ICU=100% with breaking capacity 16kA, with overload and thermal tripping feature with magnetic release imncluding certain addition or alteration if required at site complete all as specified and directed. |
| 68 | Supply & fixing as in repair, connecting, testing and commissioning of MCCB, 4 Pole, 100 Amps, 415 Volt, AC, 50Hz, ICU=100% with breaking capacity 16kA, with overload and thermal tripping feature with magnetic release imncluding certain addition or alteration if required at site complete all as specified and directed. |
| 69 | Supply and fixing modular electronic fan regulator, stepped type, 220 volt, 120 watt, 2 module complete all as specified and as directed. |
| 70 | Supply and fixing in repair modular switch one way 5/6 Amp, 1 module, 240 Volts complete all as specified and as directed. |
| 71 | Supply and fixing in repair modular switch one way modular type, 16 Amp, 1 module, 240 Volts complete all as specified and as directed. |
| 72 | Supply and fixing in repair modular switch two way modular type, 6 Amp, 1 module, 240 Volts complete all as specified and as directed. |
| 73 | Supply and fixing in repair modular socket outlet 2/3 pin plug, 6 Amps, universal socket 2 module 240 Volts complete all as specified and as directed. |
| 74 | Supply and fixing in repair modular socket 16A, 2/3 pin combined, 2 module, 240 volts complete all as specified and as directed. |
| 75 | Supply and fixing in repair modular Bell push 5/6 Amp, 1 module, 240 Volts complete all as specified and as directed |
| 76 | Supply and fix in repairs modular white cover plate with frame 1 Module complete all as specified and as directed |
| 77 | Supply and fix in repairs modular white cover plate with frame 2 Module complete all as specified and as directed |
| 78 | Supply and fix in repairs modular white cover plate with frame 3 Module complete all as specified and as directed |
| 79 | Supply and fix in repairs modular white cover plate with frame 4 Module complete all as specified and as directed |
| 80 | Supply and fix in repairs modular white cover plate with frame 6 Module complete all as specified and as directed |
| 81 | Supply and fix in repairs modular white cover plate with frame 8 Module complete all as specified and as directed |
| 82 | Supply and fix in repairs metal flush box 1/2 Module for modular switches complete all as specified and as directed |
| 83 | Supply and fix in repairs metal flush box 3 Module for modular switches complete all as specified and as directed |
| 84 | Supply and fix in repairs metal flush box 4 Module for modular switches complete all as specified and as directed |
| 85 | Supply and fix in repairs metal flush box 6 Module for modular switches complete all as specified and as directed |
| 86 | Supply and fix in repairs metal flush box 8 Module for modular switches complete all as specified and as directed |
| 87 | Supply and fixing as in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 88 | Supply and fixing as in repair LED security light fitting 35 Watt, new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP-66 roadway luminaire with high power LED source with acrylic cover complete all as specified and as directed. |
| 89 | M&L for 32mm bore light grade GI pipe fixed as bracket, on wall any type, not less than 1.5 m long and bent to shape as required complete with sutiable clamp made out of 25x4mm Flat iron duly fixed 12mm dia nuts, bolts, washers etc fixed to pole complete with two coats of aluminium paint over a coat of red oxide complete all as specified and as directed |
| 90 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, inverter light with 04 hr bachup, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 91 | Supply and fixing as in repair round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 92 | S&F in repair 18 watt LED downlight recessed/surface mounted luminaire with high brightness LED for glare-free homogenous illumination suitable for armstrong/grid ceiling and fixture size complete all as specified and as directed. |
| 93 | Supply and fixing as in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 94 | S&F in repair including testing of Antique bollard light upto 20W, 230 volts or nearest size with die cast aluminium lighting with high power LED with B22 holder as light source body, IP-65 with all necessary fixing arrangement including excvation, return filling/removal of soil, PCC work as required at site etc complete all as specified and as directed. |
| 95 | S&F in repair LED post light with B22 holder up to 20w bulb with white cover diffuser including plastic base plate of suitable size complete all as specified and as directed. |
| 96 | S&F in repair LED building security light of capacity 60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver sholud have luminaire efficiency ≥110 lumens/watt, CRI >70, PF >0.95, CCt=5700 ±300, IP 66, impact resistance, IK 07, in-built protection against lightning, over voltage, short circuit and surge / spike protection upto 10kV including connection with PVC insulated PVC sheathed, multistranded copper conductor cable of size 1.5sqmm x 3 core from light fitting to ceiling rose complete all as specified and as directed. |
| 97 | Supply and fixing GI bracket complete with not less than 2.0m long GI pipe 40mm dia medium grade with two sets clamps, nuts & bolts bend to shape all as directed for fixing of light fitting including taking down old bracket omplete all as specified & as directed. |
| 98 | Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, inverter type light with 04 hr bachup, 220 V AC, recessed type complete with high efficiency PMMA diffuser providing soft glare free light inbuilt electronic driver and integrated rechargeable lithium-ion battery for emergency operation with minimum 2 hrs back up, automatic changeover during power failure complete with holders, mounting frame & LED lamp suitable for roof false ceiling mounting including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 99 | Supply, installation, testing and commissioning of 15 watt LED self-Rechargeable emergency inverter Bulb, B22 base, cool day light, 6500K, minimum 1500 lumens with integrated Li-ion battery providing minimum 4 hrs backup, including overcharge/ deep-discharge protection and minimum 2.5 KV surge protection, confirming to IS 16102 complete all as specified and as directed. |
| 100 | Supply, installation, testing and commissioning of 12 watt LED self-Rechargeable emergency inverter Bulb, B22 base, cool day light, 6500K, minimum 1500 lumens with integrated Li-ion battery providing minimum 4 hrs backup, including overcharge/ deep-discharge protection and minimum 2.5 KV surge protection, confirming to IS 16102 complete all as specified and as directed. Please Enable Macros to View BoQ information |