| 1 | Excavation in foundation in ordinary soil (Loam,clay or sand ) including lift upto 1.50 m and lead upto 30m , including filling watering and ramming of excavated earth into the trenches and removal & disposal of surplus earth as directed by the Engineer-in-charge up to the distance of 30.00m from the foundation trench ... complete item |
| 2 | Cement Concrete with 4 cm gauge stone ballast , Coarse sand and cement in the proportion of 1:4:8 including supply of all material and labour, Tools & Plants etc. required for proper completion of the work. |
| 3 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface in plinth filling junction of wall and floor, along the external perimeter of binding expansion joints , surrounding of pipes and conduits etc. |
| 4 | M-150 Brick work in 1:6 cement Coarse sand in foundation and up to plinth …. Complete item |
| 5 | 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | 1:1:5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | 1:1:5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | R.C.C 1:1.5:3 in Slab with cement coarse sand and stone grit …. Complete item. |
| 9 | M.S (Tor steel or plain ) in plain work such as R.C.C or R.B work including cutting / bending for proper shape as necessary including supply of all steel & wastage ,bend ,hook & authorised overlapping shall be measured … complete item. |
| 10 | M-150 Brick work in 1:4 cement Coarse sand in superstructure …. Complete item |
| 11 | M.S Grills/ Stair case / railing /gates/ racks etc.- |
| 12 | Z- Section Window excluding glass panes -openable - |
| 13 | 12 mm thick Plaster in 1:4 cement sand in ceiling …complete item. |
| 14 | 12 mm thick Plaster in 1:6 cement sand …complete item. |
| 15 | 40 mm thick C.C 1:2:4 as flooring ….complete item (S.I- 605) |
| 16 | Supply and fixing of 6 to 8 mm thick ivory or light shades vitrified tiles 600 X 600 mm size in flooring and skirting with 1:3 approved cement and coarse sand mortar finished with its cement colour slurry , jointing and polished of approved quality comlete , including supply of all material , labour , tools and plants .. complete item. SI-14.26/ New Item 4 |
| 17 | Providing wall putty on new surface with approved quality of Berger/J.K/Birla or similar make in two coats. |
| 18 | Centering and shuttering complete item |
| 19 | wall painting ( two coat) with acyrlic paint of approved brand and manufacture on decorative wall surface to give an even shade including throughly brushing the surface clean all of dirt grease loose pieces and prepare smooth. |
| 20 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 |
| 22 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shane wherever required |
| 23 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 24 | GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending 12.52.1 |
| 25 | Centering and shuttring … complete item |
| 26 | Coloumn |
| 27 | Supply and fixing of Board |
| 28 | Sanitary Work |
| 29 | Electri work Please Enable Macros to View BoQ information |