| 1 | Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : Decorative veneer facings of approved manufacture |
| 2 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm |
| 3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 150x10 mm |
| 4 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). 12mm thick commercial ply conforming to IS : 1328 BWR type |
| 5 | Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. |
| 6 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 7 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 8 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 9 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 10 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase |
| 11 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 13 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 14 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 15 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 16 | Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 17 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 18 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 19 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 20 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : |
| 21 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 22 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 23 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 24 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet |
| 25 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 20 mm nominal dia Pipes |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes |
| 28 | Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 :150 mm dia pipe |
| 29 | Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 150 mm diameter pipe |
| 30 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 31 | Providing & fixing in position Phenol bonded Bamboowood flooring with planks of sizes 14mm thick, minimum 1800mm length and minimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge. |
| 32 | Modified Estimated Cost after using correction factor on DSR 2023 on account of GST@ 0.973 (vide No. 158/SE(TAS)/GST/2024/02-E-dated 08.08.2024) |
| 33 | Deduct Cost index @-0.09% |
| 34 | Providing and installing prefabricated sandwich PUF panel comprising of on two faces PPGL (galvalume ) colour coated 0.5mm TCT sheet and CFC free close cell high density figid polyurethane foam of high density (40+_2kg/m3 ) having a thermal conductivity value of 0.023 w/mk and of reuired thickness sandwich between the two galvalume sheet .the outer & inner galvalume sheet of 0.50mm TCT steel 550 Mpa shall have a coating mass of 150 g/sqm zinc aluminum alloy coating total of both sides as per AS1397 and finished with 20 microns colour coating of SMP polyster quality paint as per AS/NZS-2728:1997 (category=3) over a 5 micron primer on exposed side and a back coat of 5 microns on inner side over a 5 micron primer . the panels should be required length and required width with maximum width upto 1190mm with tongue & groove configuration the prefabricated panels shall be ficced dirctly to the girth using self drilling fasteners the metal sheet shall confirm to IS 513.AS1397&2728. The polyurethane insulation shall confirm to IS 12436. The rate of the item is inclusive of all materials erectionaccessories incidental charges coast of dash fasteners etc cost of making provision for door windows, ventilators and concealed pipe conduits and support for electrial and sanitary appliance etc and other incidental charges as per sample for payment finished puf sand witch panels shall be measured upto half centimetres for claculating area upto two places of decimal no deduction shall be made for opening upto 0.20sqm and no extra payment shall be made for wastages for roof panels 50(50/80) mm thick roofing panels having finished with 0.50mm thick TCT galvalume hi-rib sheet on outer side and 0.50mm TCT plain galvalume sheet on inner side including miscellaneous expenses of fixing accessories such as dash fasteners and making arrangement for concealed conduits etc. |
| 35 | Providing and fixing of Wood Polymer Composite Acoustic perforated tile false ceiling westo of size 595x595x12 mm square edged white colour made up of extruded WPC (Wood Polymer Composite) comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.The panels shall have a special perforation of average perforation on front & rear having minimum 8mm dia . The back of the perforated panel shall have sound absorbing non-woven acoustical fleece of fabric felt sheet of 3 mm manufactured from 100% recycle fabric of density 330 GSM, The tiles shall have true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 36 | Providing and fixing 12 mm thick HDHMR-Plain board moisture resistance type,linned with necessary screws/nuts and bolts/nails and fixed on aluminium/MS tube frame work ( frame work will be paid separtely) all complete as per direction of engineer-in-charge. |
| 37 | Providing and fixing 12.5mm thick tapered edge Gypsum plain Board for partition/wall panelling including jointing compound ,jointing tape with necessary screws/nuts & bolts/ nails, and fixed on wooden /steel frame work/GI metal framing, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). |
| 38 | Providing and fixing Glass Reinforced Concrete (G.R.C) false architraveof size 450 mm height and 300 mm base and approved size, pattern, design, shade and thickness of 50mm on frame and design element with layering technique Power Spray methodology. The false architrave should be made from '53 grade' White Portland Cement or White Quartz fine graded sieved Silica Sand, Alkali Resistant Glass Fibre, super plastisizers, polymers and UV resistant synthetic inorganic pigment etc. The fixing of false architrave should be done using 'Dry fixing' method on structural support members i/c fastener etc. complete as per direction of engineer-in-charge. |
| 39 | Providing and fixing C.P. brass bib cock with CP brass wall flange of approved make etc. all complete as per direction of Engineer-in-charge. (a) 15 mm nominal bore. (Make Jaquar (code-OPPCHR-15037PM) or equivalent in cost & specifications. |
| 40 | Providing and fixing C.P. brass angular stop cock / angle valve with wall flange of approved make etc. complete as per direction of Engineer-in-Charge. 15 mm nominal bore. (Make Jaquar (code-OPP-CHR-35053PM) or equivalent in cost & specifications. |
| 41 | Providing and fixing C.P. brass towel ring square or round shape with CP brass flange of approved make including fixing with PVC rawl plugs & screws etc. all complete as per direction of Engineer-in-charge. (Make jaquar Cat.-ACN-1121BN / 1121N or equivalent in cost & specifications.) |
| 42 | Providing and fixing C.P. brass toilet paper roll holder with flap with CP brass flange of approved make including fixing with PVC rawl plugs & screws etc. complete as per direction of Engineer-in-Charge. Make of Jaquar Cat.-ACN-1153S or equivalent in cost & specifications. |
| 43 | Providing and fixing C.P. brass Hand shower (Health Faucet) having flexible tube of required length and wall hook of approved make etc. all complete as per direction of Engineer-in-charge. (Make Jaquar Cat- or equivalent in cost & specifications |
| 44 | Providing and Fixing 32mm CP waste coupling of 130mm height for wash basin, Urinal of Jaquar make Code -ALD-CHR -727 or qquivalent in cost & specification as per approved sample shape all complete as per direction of engineer-in-charge. |
| 45 | Providing and fixing C.P. brass bottle trap, 32mm nominal bore of approved make etc. all complete as per direction of Engineer-in-charge. Make Jaquar Cat.-ALD-769L300x190 or equivalent in cost & specifications |
| 46 | Providing and fixing 450mm long braided hose/copper connections with two nos. nuts & rubber washers with or without nippleof approved make etc. complete as per direction of Engineer-in-Charge. Make Jaquar cat no.ALD-805B or equivalent in cost and specifications. |
| 47 | Providing and fixing white vitreous china Urinal With Sensor Kit, Spreader And Fixing Accessories Set, Size:360X350X710 mm having pre & post flushing with water (0.75 ltr water consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. Jaq. makecat no URS-WHT-13267 snow white or equivalent |
| 48 | Providing and fixing Rimless Wall Hung WC with UF slim soft close seat cover, Hinges, Accessories Set, Size: 360 x 500 x 330 mm (ARS-WHT-39951UFSM) 1with Single Piece Slim Concealed Cistern Body with Installations Kit & “S-Type” drain pipe connection set for Wall Hung WC and Control Plate(JCP-CHR-352415)and Cistern Full Frame (JCS-WHT-2400FS) all fittings and fixtures/ model kubix series of jaguar make with all fittings and fixtures complete including cutting and making good the walls etc complete as per direction of engineer in charge. |
| 49 | Providing and fixing Premium quality Glazed vitrified wall tiles polished finish of size 60 x 120 cm conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry+B32@ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 50 | Grouting the joints of wall Tile tiles having joints of 3 mm or above width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 51 | Providing and fixing table top wash basin(530x420x140mm) with pop up waste of standard pattern, cutting and making good the walls wherever required, complete as per direction of Engineer-in-charge.(a) Rectangle shape of make jaquar ( cat.no- JDS-WHT-25907N or equivalent in cost & specifications. |
| 52 | Providing and fixing Single Lever Basin Mixer including Exposed part kit of Jaquar make(code-KUP-CHR-35233NKPM) and Concealed Body of Jaquar make(code-ALD -CHR-233N) of Single Lever Basin Mixer Wall Mountedwith 150mm extension body fixed spout without popup waste system or equivalent in cost & specification in cost of approved make etc. complete as per direction of Engineer-in-Charge. |
| 53 | Providing and fixing 18 mm thick HDHMR-Plain board moisture resistance type,linned with necessary screws/nuts and bolts/nails and fixed on aluminium MS tube frame work ( frame work will be paid separately) all complete as per direction of engineer-in-charge. |
| 54 | Providing and fixing Urinal partition Curved 10mm of size (900x450mm) of required length and wall hook of approved make etc. all complete as per direction of Engineer-in-charge. (Make Jaquar Cat-JSE -CHR-110UC450X) or equivalent in cost & specifications |
| 55 | Providing and fixing 2nd Class teak wood design moulding of required design & pattern location where it required with necessary fixing arrangement on exposed surface etc. complete as per direction of Engineer-in-Charge. (Size 15mm). |
| 56 | Providing and fixing 2nd Class teak wood design moulding of required design & pattern location where it required with necessary fixing arrangement on exposed surface etc. complete as per direction of Engineer-in-Charge. (Size 25mm). |
| 57 | Providing and fixing 2nd Class teak wood design moulding of required design & pattern location where it required with necessary fixing arrangement on exposed surface etc. complete as per direction of Engineer-in-Charge. (Size 35mm). |
| 58 | Providing and fixing 2nd Class teak wood design moulding of required design & pattern location where it required with necessary fixing arrangement on exposed surface etc. complete as per direction of Engineer-in-Charge. (Size 75mm). |
| 59 | Providing and Fixing Quartz Stone work (polished and machine cut) of thickness 20 mm for Washbasin Counter, backing filled with pasting araldite adhesive (1.25Kg/Sqm) including pointing with white cement or matching pigment with an admixture of pigment to match the Granite shade . Quartz in any colour. Area of slab above 0.50 Sqm |
| 60 | Wall painting with Royale paint of asian or equivalent paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 61 | Providing and fixing Glass Reinforced Concrete (G.R.C) Capitol for column of approved size, pattern, design, shade and thickness of 50mm on frame and design element with layering technique Power Spray methodology. The capital should be made from '53 grade' White Portland Cement or White Quartz fine graded sieved Silica Sand, Alkali Resistant Glass Fibre, super plastisizers, polymers and UV resistant synthetic inorganic pigment etc.The fixing of Capital should be done using 'Dry fixing' method onto structural support members i.e. MS Framework. SS/MS Galvanized CLAMPS & PIN also if required. GRC Capital Installation features of the main circular/Round column capital with a diameter of 850mm ,height 290 mm.The capital is to be entire structure is secured using 5 - inch heavy duty self drilling screws and other necessarary fixing arrangnment complete as per direction of Engineer-in-Charge. |
| 62 | Providing and fixing Glass Reinforced Concrete (G.R.C) Base for column of approved size, pattern, design, shade and thickness of 50mm on frame and design element with layering technique Power Spray methodology. The Column Base should be made from '53 grade' White Portland Cement or White Quartz fine graded sieved Silica Sand, Alkali Resistant Glass Fibre, super plastisizers, polymers and UV resistant synthetic inorganic pigment etc.The fixing of Column Base should be done using 'Dry fixing' method onto structural support members i.e. MS Framework. SS/MS Galvanized CLAMPS & PIN also if required. GRC Capital Installation features of the main circular/Round column capital with a diameter of 650mm ,height 150 mm.The capital is to be entire structure is secured using 5 - inch heavy duty self drilling screws and other necessarary fixing arrangnment complete as per direction of Engineer-in-Charge. |
| 63 | Providing and fixing Glass Reinforced Concrete (G.R.C) Column of semi circular of approved size, pattern, design, shade and thickness of 50mm on frame and design element with layering technique Power Spray methodology. The column should be made from '53 grade' White Portland Cement or White Quartz fine graded sieved Silica Sand, Alkali Resistant Glass Fibre, super plastisizers, polymers and UV resistant synthetic inorganic pigment etc. The fixing of Column should be done using 'Dry fixing' method onto structural support members i.e. R.C.C. Brick work, MS Framework. SS/MS Galvanized CLAMPS & PIN also if required fasteners to be used. |
| 64 | Providing and fixing superior class bright lacker finished special quality brass handles with necessary screws etc., completed size of 300 mm complete as per approved sample in DVS drawings and as per the direction of Engineer - in-Charge. |
| 65 | Dismantling wall tile inclusive base plasterof all thickness fixed in cement mortar / tile adheshive including racking out joints and cleaning the surface including disposal of rubish to the designated location etc. complete as per direction of Engineer-in-charge. |
| 66 | P/F teak wood skirting having minimum thickness up to 40 mm and minimum width of 300 mm as per approved design and pattern fixed on exposed surface with necessary fixing arrangement complete as per direction of Engineer-in-charge. |
| 67 | Providing and fixing Action tesa wooden laminated flooring with planks of 8mm thick ,600mm length & 99mm wide 8mm of AC-4 (Heringbone)of approved colour,texture and finish quality with 2mm thick PU foams as per approved colour ,shade and design complete as per direction of Engineer-in-charge. |
| 68 | Providing and fixing beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 69 | Providing and fixing VENETIAN BLINDS of WOODEN VENETIAN SERIES FAUSTINA 50 MM ladder string of Vista make as per approved sampe and shade including all necessary fittings, rails, . all complete as per manufacturer's specifications and as per the direction of Engineer-in-Charge. |
| 70 | Providing and fixing factory made 25mm or required size as per direction of engineer in charge beading with colour matching of wall panelling board original quarter round moulded fixed with wooden adhesive of approved quality and screws/ nails as per direction of Engineer-in-charge. |
| 71 | Providing and fixing stainless steel A ISI 304Kitchen sink as per IS: 13983 with stainless steel plug 40mm including cutting and making good the wall wherever required .HANDMADE Double BOWL SINKS size 45 x 20X10 inch or required size ( Ruhe Make model CAT NO. SKU:13-0303-02-Ex ) as per direction of Engineer-in-charge. |
| 72 | Providing and fixing Single Lever Sink Mixer With Swinging Spout on Upper Side (Wall Mounted Model) With Connecting Legs & Wall Flanges of Jaquar make (Model No. FON-40165 or equivalent as per direction of engineer in charge. |
| 73 | Providing and fixing CP Brass Square Flat Cut Floor Drain with Plain Jali and Hinge (5 x 5 Inches) - LIPKA or approved make of approved quality and colour. As per engineer in charge |
| 74 | Credit for Dismantled Wooden materials |
| 75 | Credit for Dismantled C.P Fittings |
| 76 | Credit for Dismantled M.S./Reinforement bar materials Please Enable Macros to View BoQ information |