| 1 | Dismantling of Asbestos cement (corrugated, semicorrugated and Transulent sheet etc) sheets/ mangalore tiles in roof covering incl ridges complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 3 | S&F Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridges fixed with self tapping screws complete all as specified and directed. |
| 5 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Grade Fe 410 -W (Gde E- 250) quality A complete all as specified and directed. |
| 6 | M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 7 | Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof padding etc and removing of debris from outside MD land complete all as specified and as directed. |
| 8 | M&L for 10 mm thick Plaster on RCC roof slab and sunken portion with CM ( 1:3 ) mixed with water proofing compound @ 3% by weight of cement used or as per manufacturer's instruction.complete all as specified and as directed.(Note : WPC shall be measured and paid separately under relevant item) |
| 9 | M&L for PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate as in roof padding / sunken floors and similar work using WPC @ 3% by wt of cement used or as per manufacturer's instruction.complete all as specified and directed.(Note : WPC shall be measured and paid separately under relevant item) |
| 10 | Supply only Integral Water proofing Compound complete all as specified and as directed. |
| 11 | M&L for Water Proofing Treatment with APP based Standard Membrane over PCC padding in approachable roof with the following courses of treatment :(a) Apply bituminous primer ( IS 3384 ) @ 0.30 Kg per Sqm of the surface area including cleaning the surface complete all as specified .(b) Apply APP plastomeric bitumen based water proofing membrane polyester reinforced (3.50kg /Sqm ) with 10 cm overlaps and torch bonded at joints including surface preperation before and after application of treatment as per manufacturers instruction complete all as specified and directed. |
| 12 | M&L for applying a coat of reflective bitumenous aluminium paint @ 0.15 Kg / sqm over Bitumen surface complete all as specified and as directed. |
| 13 | Demolition of Precast cement concrete block walling built in CM or Cement lime Mortar complete all as specified and as directed. |
| 14 | M&L for precast cement concrete block masonry exc. 10 cm width with solid block C1 (1:3:6) (using 20 mm graded crushed stone aggregate) and setting in cement mortar (1:6) complete all as specified and directed. |
| 15 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan- necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories). complete all as specified and directed. |
| 16 | S&F in repair 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent including taking down complete all as specified and directed. |
| 17 | S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 18 | S&F 110mm dia PVC (SWR) bends with acess door any radius complete all as specified and directed. |
| 19 | S&F 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent complete all as specified and directed. |
| 20 | S&F 75 mm dia PVC (SWR) grade bends of any radius complete all as specified and directed. |
| 21 | S&F 75 mm dia PVC (SWR) grade bends with acess door of any radius complete all as specified and directed. |
| 22 | S& F in repairs for 20mm bore CPVC pipe outer dia of pressure ratings 11 SDR-II including all fittings fixed complete to walls, ceiling or in floor etc complete all as specified and directed. |
| 23 | S& F in repairs for 25mm bore CPVC pipe outer dia of pressure ratings 11 SDR-II including all fittings fixed complete to walls, ceiling or in floor etc complete all as specified and directed. |
| 24 | S&F in repairs 25mm dia CPVC gate valves screwed both ends for iron pipes complete all as specified and directed. |
| 25 | S&F rotational moulded Polyethylene [HDPE] water tanks, Triple layered, ISI Marked Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including taking down old tanks complete all as specified and as directed. |
| 26 | S&F rotational moulded Polyethylene [HDPE] water tanks, Triple layered, ISI Marked Cylindrical & Vertical Type 500 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including taking down old tanks complete all as specified and as directed. |
| 27 | Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc. 500 liters and not exc. 1000 liters complete all as specified and as directed(Note: Each tank will be shifted as twice) |
| 28 | Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc.250 liters and not exc. 500 liters complete all as specified and as directed(Note: Each tank will be shifted as twice) |
| 29 | Seven stage Cleaning and sterilization of inside the RCC/PVC water storage tank of capacity exceeding 250 Ltr and not exceeding 2000Ltr of any description and in any position comprising following cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/Inchlor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 and ULTRA VOILET RAY. Make: Rays Cleanthch/ Inus watertech/ satya enterpriseSeven Stages are as under plants:-(a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/Inox-60/B-69 laboratory tested branded chemical of the company and scrubbing the walls of the tanks .(c) Third stage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified branded halogen compound orEni Capproved Equivalent product (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner.(f). Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria.(g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor ofthe water tank by using laboratory certified, branded strong oxidizing agent TERBAC-65/Inoxi-60/NB-69 or E-in-C approved equivalent Product. Please Enable Macros to View BoQ information |
| 30 | Seven stage Cleaning and sterilization of inside the RCC/PVC water storage tank of capacity exceeding 250 Ltr and not exceeding 2000Ltr of any description and in any position comprising following cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/Inchlor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 and ULTRA VOILET RAY. Make: Rays Cleanthch/ Inus watertech/ satya enterpriseSeven Stages are as under plants:-(a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/Inox-60/B-69 laboratory tested branded chemical of the company and scrubbing the walls of the tanks .(c) Third stage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified branded halogen compound orEni Capproved Equivalent product (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner.(f). Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria.(g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor ofthe water tank by using laboratory certified, branded strong oxidizing agent TERBAC-65/Inoxi-60/NB-69 or E-in-C approved equivalent Product. Please Enable Macros to View BoQ information |