| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floor not exceeding 15cm thickness below or above ground level including floor finishes and removing debris from the site all as specified and as directed. |
| 2 | Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified. |
| 3 | Demolition of tiles/kota stone/granite/marble/mosaic flooring /wall tiling etc, including cement mortar bedding/backing coat incl removing rubbish off the premises as directed by Engr in-Charge complete all as specified. |
| 4 | M&L for Vitrified ceramic (Coloured) tiles double charged 10mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 5 | All as per item No-04 but as skirting/dado including laid over 10 mm thick screed bed plaster in CM 1:4, complete all as specified. |
| 6 | M&L for Vitrified ceramic (Coloured) tiles double charged 10mm thick (square/ rectangular) area of each tile exceeding 0.36 sqm but not exc 0.72 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 7 | All as per item No-06 but as skirting/dado including laid over 10 mm thick screed bed plaster in CM 1:4, complete all as specified. |
| 8 | M&L for non skid ceramic (coloured) tiles of approved shade and pattern, of 300 x300x 7 to 8 mm thick,as in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 9 | M&L for Elevation wall tiles water resistant designed for vertical surfaces/ceramic (coloured) tiles of approved shade and pattern of size 300X450X7 to 8 mm thick or any other nearer size as approved by Engineer incharge in vertical surface set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles complete all as specified and as directed. |
| 10 | M&L for glazed ceramic (coloured) tiles of approved shade and pattern of size 300X450X7 to 8 mm thick or any other nearer size as approved by Engineer incharge in vertical surface set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles complete all as specified and as directed. |
| 11 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete.including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed. |
| 12 | Rounding to edges of stone slabs one edge,such as in steps, cooking platform, and other similar situations |
| 13 | M&L for machine cut kota stone slab flooring 18-20 mm (+ 2mm) thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 14 | M&L for mirror polished machine cut kota stone slab 15-16 mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 and jointed complete all as specified and as directed. |
| 15 | M&L Marble tiles 30cmx10cm x 20mm or any nearer size as in border of kota stone thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing laid over 15mm thick screed bed or bedding layer in CM 1:6 complete of Makrana white as specified by Engr-in Charge. |
| 16 | Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete. |
| 17 | M&L 25 mm thick plain cement concrete 1:2:4 type B-1, (20mm graded aggregate) as levelling course/undulation of floor etc, complete all as specified and as directed. |
| 18 | M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection, 75 mm thick, surfaces finished even and fair without using extra cement including provision of construction joints complete all as specified. |
| 19 | M&L for 75mm thick PCC 1:4:8 type D-2, (40mm graded stone aggregate) as in sub floor, sub bases, floor and paving etc; complete all as specified. |
| 20 | M&L Cement concrete type E-2 ,1:5;10 using 40 mm graded stone aggregate as sunken in foundations,filling and mass concrete complete all as specified. |
| 21 | Providing and laying 60mm thick factory made table vibratory, PU mould, chamfered edge cement concrete coloured paver block of M-35 grade with approved design & pattern as in footpath, drive ways or parking etc; over and including 50mm thick compacted bed of fine sand and proper embedding/ laying of inter locking paver blocks into the sand bedding layer, filling the joints with sand and cutting of paver blocks as required, complete all as specified and as directed. |
| 22 | Providing and laying factory made kerbs stone any size of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, embedded in position including all necessary excavation, tamping ground around blocks and removal of rubbish/ surplus soil etc; making joints with or without grooves, drainage opening wherever required complete all as specified and as directed. |
| 23 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified. |
| 24 | M&L 40mm thick cement concrete type B-1,1:2:4 (20mm graded aggregate) incl finishing cement concrete surface even and smooth without using extra cement complete all as specified. |
| 25 | S&F 38mm thick Plastic dividing strips,1.5mm thick dividing strips, 1.5mm thick, inserted in position,conform to design complete all as specified. |
| 26 | Demolition of stone/ brick work masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stone work, serviceable stone aside for reuse and removing unserviceable material in low laying area complete all as specified and as directed. |
| 27 | M&L Pre-cast cement concrete block masonry type C-1,1:3:6 (20 mm graded stone aggregate ) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and directed. |
| 28 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified. |
| 29 | M&L for rendering 15 mm thick readymix plaster on internal wall with smooth finished using Ultra Tech READIPLAST or any equivalent approved make by adding 17-19% of potable water by weight of material. For thickness above 15mm it is recommended to be applied in multiple layers.Ready-mix plaster shall complies with IS 1661-1972. IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Day-10-12 Mpa/Bulk density-1500-1600 Kg/Cum. all as specified and directed. |
| 30 | M&L for rendering 15 mm thick ready mix plaster on External wall with smooth finished using Ultra Tech READIPLAST or any equivalent approved make by adding 17-19% of potable water by weight of material. For thickness above 15mm it is recommended to be applied in multiple layers.Ready-mix plaster shall complies with IS 1661-1972. IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Day-10-12 Mpa/Bulk density-1500-1600 Kg/Cum, all as specified and directed. |
| 31 | M&L for rendering 10 mm thick readymix plaster on Ceiling with smooth finished using Ultra Tech READIPLAST or any equivalent approved make by adding 17-19% of potable water by weight of material. For thickness above 15mm it is recommended to be applied in multiple layers.Ready-mix plaster shall complies with IS 1661-1972. IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Day-10-12 Mpa/Bulk density-1500-1600 Kg/Cum , all as specified and directed. |
| 32 | S&F low carbon annealed wire in hexagonal shape 1.0mm diametre chicken wire mesh of size 25mm (distance between the faces of the hexagon), durable twisted woven mesh for mounting on curved and angled surfaces including 15cm lap at junction fixed with nails and properly stapled complete all as specified and as directed. |
| 33 | Demolition of wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified. |
| 34 | S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified. |
| 35 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 36 | S&F in repair Gypsum board 10-12 mm thick in ceilling fixed with screw as per manufacturer's instructions, plain/ colour fixed with steel snap grid (powder coated bottom side) with 'T' and 'L' (25mmx30mmx1.00mm thick) section of size 600mm x 600mm placed in ceiling 'L' section fixed to wall with PVC rawal plugs and steel screws @ 600mm centre to center, including provided 5.0 mm dia galvanised bars/ wire suspended @ 1.80 mtr centre to center both sides proper hanging arrangements and maintain levels with adjustable clips, complete all as specified and directed. (Note:- If any minor electricial fittings and fixtures disturbed their-in will be match and fixed as existing). |
| 37 | M&L for removing any type of Grass/plants/bushes (girth n.exc 15cm of trunk of any of plants 100mm) grown along the pipes or walls chajjas, parapets and roof of building and making good the surface as per existing surfaceand pouring acid not less than 100ml for each plant in the roof to avoid further growth and filling the disturbed area with cement concrete (1:1.5:3) or cement mortar (1:3) using waterproofing compound as per manufacturer's instruction and making the patch finished with painting as per surroundings complete all as specified and as directed. (Note:- Rate quoted is deemed to be included for scaffolding, saftey, measured required for working on or upto height of 20 m vertical slopes.) |
| 38 | Preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cm and applying two coats of synthetic enamel paint complete all as specified and as directed. |
| 39 | Preparing new plastered surfaces and M&L for applying Chalk whiting, on plastered surfaces, prepara-tory to distempering incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on new plastered surfaces complete all as specified and as directed. |
| 40 | Preparing new plastered surfaces and incl Priming plastered and other surfaces with alkaliresistant priming paint surfaces smooth by rubbing and / or sandpapering and M&L two coats of cement base paint on new plastered surfaces complete all as specified and as directed. |
| 41 | Preparation of new plastered surfaces of walls etc. & applying three coats of lime white wash on walls complete all as specified and as directed. |
| 42 | Preparation of new plastered surfaces of ceiling etc. & applying three coats of lime white wash on ceiling complete all as specified and as directed. |
| 43 | Taking down shutters any description exc 1.00 sqm but not exc 2.00 Sqm each and refixing the shutter in same opening after easing and adjusting, complete all as specified and as directed. |
| 44 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing from site or to store as directed by Engineer incharge. |
| 45 | S&F Powder Coating (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 46 | S&F for figured glass, pin head type ordinary quality, 4mm thick, area of each pane not exceeding 0.5Sqm and glazing with aluminium beading in aluminium frame all as specified and as directed. |
| 47 | S&F of sheet glass ordinary quality 4 mm thick and glazing with oil putty or fixed with wooden beads or fixed with rubber gasket in squares any size of pane complete all as specified & as directed. |
| 48 | S&F of factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing S&F. Make : Rajshree Doors or equivalent as approved by GE. |
| 49 | S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. Make : Rajshree Doors or equivalent as approved by GE. |
| 50 | S&F 150 mm long aluminium handles, cast type,anodised fixed with steel screws complete all as specified. |
| 51 | S&F 150 mm long aluminium anodised,barrel tower bolts of extruded section and fixed with steel screws complete all as specified. |
| 52 | S&F in repair 300 mm Mild steel sliding door bolts,plate type, stove enamelledblack, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed all as specified and directed. |
| 53 | Supply and Fixing in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 54 | Supply and fixing in repairs Mild steel window handle left/right including neccesary welding complete all as specified and directed. |
| 55 | Supply and fixing in repairs Mild Steel window peg stay for supporting window glass etc complete all as specified and directed. |
| 56 | Material and Labour for 3mm thick plain sheet glass ordinary quality including glazing with putty area n.exc 0.5 sqm in each pane including hacking out old broken glass from metal frame including punching or drilling out old glazing pins/spring clips and providing complete all as specified and directed. |
| 57 | Supply and fixing in repair Aluminium (Die cast) body Door closer hydraulically regulated designation No 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed |
| 58 | Supply and fixin in repair for aluminium section of size 38x65x1.3mm thick partition wall/wall panelling fixed to wall on aluminium frame work fixed panel with 5mm thick plain glass/12mm thick particle boards and fixed with glazing clips rubber beading including suitable section complete all as specified and directed. |
| 59 | Taking down anodised aluminium window any type n. exc 1.5 sqm refixing in same opening after repairing including necessary jointing cleats, glazing clips, rubber packing, screws etc and with existing anodised aluminium snap beading, screws anodised aluminium fittings such as hinges type B-21, 125mm long anodised section complete including overhauling of floor door spring hydaulically regulated complete all as specified and directed. |
| 60 | Taking down anodised aluminium doors any type exc 1.5 sqm but n.exc 4.00 sqm refixing in same opening after repairing including necessary jointing cleats, glazing clips, rubber packing, screws etc and with existing anodised aluminium snap beading, screws anodised aluminium fittings such as hinges type B-21, 125mm long anodised section complete including overhauling of floor door spring hydaulically regulated complete all as specified and directed. |
| 61 | S&F in repair decorative mild steel curtain rods 32mm dia (powder/ PVC coated) including fixing brackets & side cups Lattu and fency type knobs complete fixed in complete all as specified and directed |
| 62 | S&F in repair stainless steel curtain rods 25mm dia including fixing SS brackets Lattu & side cups /fency type knobs complete complete all as specified and directed |
| 63 | Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 64 | Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 65 | S&F 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 66 | S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 67 | S&F in repair vitreous china squatting pan, Orissa pattern, size 580x440mm white/ coloured with integral foot rests including flus pipe and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified. |
| 68 | M&L in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete and making good the disturbed portion etc. including 32 mm waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms and Urinal spreader of PTMT any colour forfixing with 15 mm dia pipe. (Minimum weight 60gms) all as specified and directed. |
| 69 | S&F in repair PVC 10 ltr. Cap. valveless syphonic action type, flushing cictern, low level, white/ coloured with inlet, ball valve, float and handle including brackets and connection to pipe etc. all as specified. |
| 70 | S&F in repair vitreous china wash basin, white/ coloured, flat back, size 550x400mm including PTMT waste fittings, 32mm bore size, waste pipe pvc 32mm bore and angle iron brackets of required size and length etc. and making good disturbed surfaces to match with the existing complete all as specified. |
| 71 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified. |
| 72 | S&F in repair 5mm thick bevelled edge mirror of fancy type selected quality including making 4 to 8 x Nos holes and fixing with Stainless steel spacer /SS cup washers complete all as specified and as directed . |
| 73 | S&F in repair 15mm bore chromium plated bib taps, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified. |
| 74 | S&F in repair PTMT bib Tap, screwed down high pressure, screwed for 15mm bore iron pipe or for brass ferrule complete all as specified and directed. |
| 75 | S&F in repair PTMT Angle valve screwed down high pressure, screwed for 15mm bore iron pipe or for brass ferrule complete all as specified and directed. |
| 76 | S&F in repair pillar tap, brass, 15mm dia, with capston heads, chromium plated, fancy type screwed down, high pressure, with or without lettered hot or cold, with long shank, screwed shanks and fly nuts, screwed for iron pipes or for wash hand basin all as specified and as directed. |
| 77 | S&F in repair 15mm bore angle valve chromium plated, fancy type cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe with long shank and cup complete all as specified. |
| 78 | S&F in repair chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union suitable for 15mm bore pipe etc; complete all as specified. |
| 79 | S&F in repair CP greating doom 100-125mm dia complete all as specified. |
| 80 | S&F in repair 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (minimum weight for 25mm ball valves-455gms) complete all as specified and as directed. |
| 81 | M&L for carrying out water proofing treatment for sunken portion in the following stages - (i) Taking down of existing sunken slab treatment from the sunken portion and cleaning the surfaces washing down with water and rubbish of the pemises , cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00kg/sqm and grouting 25mm thick cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate on sunken slab portion and finishing the top surfaces even and smooth without using extra cement. (ii) M&L for two coat of acrylic cementitious water proofing coating (Dr FIXITpidifin 2k manufactured by M/s Pidilite Industries Ltd or equivalent) and followed by a overlay protective screed (10mm thick cement mortar (1:4) along with liquid water proofing compound approved make as per manufacturer's instructions) on top surfaces of sunken slab after preprations as mentioned above. Method of application for acrylic cementitious water proofing coating achieved as per manufacturers instruction complete all as specified and directed. |
| 82 | Dismantling cast iron work of any description and in any position complete all as specified. |
| 83 | S&F 100mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, laid in trenches or in floor etc; complete all as specified. |
| 84 | S&F 100mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, fixed to walls etc; complete all as specified. |
| 85 | S&F 75mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, laid in trenches or in floor etc; complete all as specified. |
| 86 | S&F 75mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, fixed to walls etc; complete all as specified. |
| 87 | S&F 100mm bore pipe cast iron 'P' or 'S' trap, complete all as specified. |
| 88 | S&F 75mm bore pipe cast iron 'P' or 'S' trap, complete all as specified. |
| 89 | S&F 100mm bore pipe cast iron cowls, complete all as specified. |
| 90 | S&F 75mm bore pipe cast iron cowls, complete all as specified. |
| 91 | M&L cast iron up to 150mm bore fittings of Bends (any type, radious and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces, single branch, 'Y' junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc; complete all as specified. |
| 92 | M&L 100mm bore cast iron pipes and fittings joints or connections are filled/ sealed properly by epoxy sealant of ISI mark or M-Seal (Make:- Dr Fixit) apply as per manufacturing instructions, complete all as specified. |
| 93 | M&L 75mm bore cast iron pipes and fittings joints or connections are filled/ sealed properly by epoxy sealant of ISI mark or M-Seal (Make:- Dr Fixit) apply as per manufacturing instructions, complete all as specified. |
| 94 | S&F for 100mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc; complete all as specified. |
| 95 | S&F for 75mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc; complete all as specified. |
| 96 | S&F in repair providing precast cement concrete type B-0 1:2:4 (12.50 mm graded stone aggregate) as in louvres and jallies, 25mm thick (measured solid), including all mouldings set in CM 1:4 complete all as specified. |
| 97 | M&L for carrying out repair dammaged RCC projections,chajja facia, roof projection facia, etc in the following stages -(i) Demolition of existings dammaged RCC projection,chajja facia, roof projection facia and similar suspended work and (reinforcement cut as required to facilitate demolition).(ii) Preparation of existing demolised portion by scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC and providing non-shrink,cemrntitious MICRO CONCRETE including necessary form work and reinforced with low carbon annealed wire in hexagonal shape 1.0mm diametre chicken wire mesh of size 25mm complete.(iii) Providing and applying approved chemical rust remover with paint brush on corroded rebar and removing loose particles after 24 hours of its application and washed with sufficient quantity of water to make rebar free from corrosion.(iv) Providing & fixing new reinforcement of various diameters as required at site in the form of mild steel and /or steel confirming to IS and lapping, welding, anchoring suitable to the old reinforcement including cutting, bending with all tools & tackles etc;(v) Applying 1st coat rendering of 10mm thick in CM (1:3) over demolished concrete facia/projection surfaces and allow to dry 6-8 Hrs and cured with gunny jute bag. (vi) Applying finished coat of 10mm thick rendering in CM 1:4 using 100% coarse sand over 1st coat rendered surfaces and finished surface even and smooth with using extra cement and mixed with 3% integral water proofing compound and making drip mouldings as reqiured and cured with jute gunny bag for 7 days,complete all as directed by Engr-in-Charge.(vii) Preparation of surface and applying two coats of weather coat paint over a coat of exterior wall care putty to match existing surfaces complete all as specified and as directed.Note:- (Reinforcement shall be paid in respective item of Schedule A)The rates quoted by the bidders/Contractor shall include the following:-(a) Work carried out up to 12 Mtr in height.(b) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and all protective measures responsibilty.(c) Removal of excavated material n exc. 50m and depositing where directed by Engr-in Charge. |
| 98 | S&F brass spindle / phase for 15mm dia CP wall mixer, CP WHB mixer, CP two way bib taps,CP bib cocks/ CP pillar cocks / CP angle cocks etc complete all as specified and directed. |
| 99 | S&F Brass spindle / phase for 15mm dia CP concealed stop cocks etc complete all as specified and directed. |
| 100 | S&F in repair 32mm waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) |
| 101 | S&F in repair 40mm waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) |
| 102 | S&F in repair 32mm waste coupling of PTMT but suitable for urinals, ((half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) |
| 103 | S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes;including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm |
| 104 | S & F in repair Flush syphon Kit for any respective pattern for low level flushing cistern any description complete all as specified. |
| 105 | S&F in repair 32mm waste pipe approx 1mtr in length sutaible for Sink/Urinal/WHB |
| 106 | DB2K Specification applied as following stages-(i) Surface Preparation :- Surface preparation to be done by Mechanical means such as grinding, chasing open the construction joints , Small cracks, Corner joints , bug holes should be opened up, cleaned and filled with Powder Based Repair Mortar.(ii) Bore Packing: All the borehole gaps between concrete surface,stone masonary pointing/joints and all conduit pvc pipe of various dia upto the neck level shall be filled with dual-shrinkage compensated free flow grout - SmartCare GP Grout or approved equivalent The periphery of the PVC pipe should be sealed with SC Hybrid PU Sealant. (iii) Application of Bond coat- SBR based Repair Polymer.Waterproofing Coating: Application of two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Dampblock 2K or equivalent with a consumption of 1.5 Kg/Sqm in 2 coats. Cure the coating for another 3-4 days, Water pond taste etc as per manufacturers specifications as under-The coating shall be CFTRI Certified.Elongation >80±15% per ASTM D 2370Hydrostatic pressure resistance - Positive side 5 Bar as per EN12390-8:2019. Crack bridging upto 1±0.3 mm as per EN 1062. |
| 107 | Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including casing capping, conduit, sunken boxes etc for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed by Engineer-in-Charge |
| 108 | M&L for point wiring One ligh controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed by Engineer-in-Charge |
| 109 | All as per items srl No 108 above but for One Fan point |
| 110 | All as per items srl No 108 above but for One bell point |
| 111 | All as per items srl No 108 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 112 | All as per items srl No 108 above but for One socket out let 5 Amps 5 pin on independent board |
| 113 | All as per items srl No 108 above but for One light point controlled by two switch two way |
| 114 | All as per item No 108 here in before but with single core multistranded cable of size 4.0 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge. |
| 115 | M&L for point wiring One light point controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty casing capping on wall with accessories like elbow, tees etc fixed on wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed by Engineer-in-Charge |
| 116 | All as per items srl No 115 above but for One Fan point |
| 117 | All as per items srl No 115 above but for One bell point |
| 118 | All as per items srl No 115 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 119 | All as per items srl No 115 above but for One socket out let 5 Amps 5 pin on independent board |
| 120 | All as per items srl No 115 above but for One light point controlled by two switch two way |
| 121 | All as per item No 115 here in before but with FRLSH multistranded cable of size 4.0 Sqmm and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge for:- One socket outlet 15 Amp power point on Independent board. |
| 122 | M&L for modular point wiring One light point controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed by Engineer-in-Charge |
| 123 | All as per items srl No 122 above but for One Fan point |
| 124 | All as per items srl No 122 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 125 | All as per items srl No 122 above but for One socket out let 5 Amps 5 pin on independent board |
| 126 | All as per items srl No 122 above but for One light point controlled by two switch two way |
| 127 | All as per item No 122 here in before but with FRLSH multistranded cable of size 4.0 Sqmm and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge for:- One socket outlet 15 Amp power point on Independent board. |
| 128 | Material and labour for Elect bell AC 230 Volts single phase musical type complete all as specified and as directed. |
| 129 | Material and labour for bell push flush type 5 Amps complete all as specified and as directed. |
| 130 | Supply and fixing switch piano flush type 5 Amps single pole one way complete all as specified and as directed. |
| 131 | Supply and fixing switch piano flush type 5 Amps single pole two way complete all as specified and as directed. |
| 132 | Supply and fixing socket out let 2 in 1 multi pin 5 Amps flush type complete all as specified and as directed.universal |
| 133 | Supply and fixing switch piano15/16 Amps one way 240 volts complete all as specified and as directed. |
| 134 | Supply and fixing socket outlet in repair 2 in 1, 3 pin, 5 and 15 Amps socket outlet 240 volts complete all as specified and as directed. |
| 135 | Supply and fixing modular switch 6 Amps single module one way complete all as specified and as directed. |
| 136 | Supply and fixing modular switch 6 Amps single module two way complete all as specified and as directed. |
| 137 | Supply and fixing modular socket 6 Amps 5 pin double module complete all as specified and as directed. |
| 138 | S&F modular switch 16 Amps single module complete all as specified and as directed. |
| 139 | Supply and fixing modular socket 6&16 Amps 5 pin double module complete all as specified and as directed. |
| 140 | Supply and fixing modular Fan step regulator 120W, two module complete all as specified and as directed. |
| 141 | Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and as directed |
| 142 | Supply and fixing Ceiling rose on PVC FRLSH board size 65 X 50 mm three terminal complete all as specified and as directed |
| 143 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps B curve type ,230 volts, 10 KA complete all as specified and as directed |
| 144 | Material and labour in replacement for bell push flush type 5 Amps complete all as specified and as directed. |
| 145 | Supply and fixing in replacement switch piano flush type 5 Amps single pole one way complete all as specified and as directed. |
| 146 | Supply and fixing in replacement switch piano flush type 5 Amps single pole two way complete all as specified and as directed. |
| 147 | Supply and fixing in replacement socket out let 2 in 1 multi pin 5 Amps flush type complete all as specified and as directed.universal |
| 148 | Supply and fixing switch piano15/16 Amps one way 240 volts complete all as specified and as directed. |
| 149 | Supply and fixing in replacement socket outlet in repair 2 in 1, 3 pin, 5 and 15 Amps socket outlet 240 volts complete all as specified and as directed. |
| 150 | S&F modular bell push 6 Amps single module complete all as specified and as directed. |
| 151 | Supply and fixing in replacement modular switch 6 Amps single module one way complete all as specified and as directed. |
| 152 | Supply and fixing in replacement modular switch 6 Amps single module two way complete all as specified and as directed. |
| 153 | Supply and fixing in replacement modular socket 6 Amps 5 pin double module complete all as specified and as directed. |
| 154 | S&F in replacement modular switch 16 Amps single module complete all as specified and as directed. |
| 155 | Supply and fixing in replacement modular socket 6&16 Amps 5 pin double module complete all as specified and as directed. |
| 156 | Supply and fixing in replacement modular Fan step regulator 120W, two module complete all as specified and as directed. |
| 157 | Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and as directed |
| 158 | Supply and fixing in replacement Ceiling rose on PVC FRLSH board size 65 X 50 mm three terminal complete all as specified and as directed |
| 159 | Taking down unserviceable ceiling fan/exhaust fan from its position and handing over to occupant for further disposal/ resue. |
| 160 | Hanging only repaired/new ceiling fan/exhaust fan any make and size held by occupant |
| 161 | Supply and fixing in replacement Lamp Holder, PVC FRLSH/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 162 | S&F of old unsv LED Tube light1 X 20 watt (04 feet), decorative ultra slim type, with integral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. |
| 163 | S&F of old unsv LED Tube light1 X 10 watt (02 feet), decorative ultra slim type, with integral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed |
| 164 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 165 | Supply and fixing LED clear white Bulb of 12 watt, 240 Volt type . |
| 166 | Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 08 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down complete including taking down old existing as directed by Engineer-in-Charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 167 | Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 12 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down complete including taking down old existing as directed by Engineer-in-Charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 168 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete including taking down old existing as directed by Engineer-in-Charge. |
| 169 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning complete including taking down old existing as directed by Engineer-in-Charge. |
| 170 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral current carrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning complete including taking down old existing as directed by Engineer-in-Charge. Note - The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail