| 1 | M&L for preparation of old surfaces of walls and applying one coat of white wash including filling of cracks with approved crack filler complete all as specified and directed. Note : white wash shall be done by roller only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 2 | M&L for preparation of old surfaces of walls and applying one coat of colour wash, including filling of cracks with approved crack filler complete all as specified and directed . Note : colour wash shall be done by roller only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 3 | M&L for preparation of old surfaces of ceilings and applying one coat of white wash, including filling of cracks with approved crack filler complete all as specified and directed .Note : white wash shall be done by roller only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 4 | M&L for Preparation of old plastered or unplastered or distempered surfaces of walls including filling of cracks with approved crack filler and applying one coat of oil bound distemper white or coloured complete all as specified and directed.Note : Oil bound distemper shall be done by roller/spray only, after complete removal of old loose flakes.Complete all as specified and directed. |
| 5 | M&L for Preparation of plastered or unplastered old surfaces of ceiling and applying one coat of oil bound distemper including filling of cracks with approved crack fillercomplete all as specified and directed.Note: Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 6 | M&L for complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over one coat of 1 mm thick wall care putty complete all as specified and directed. Note : Oil bound distemper shall be done by roller only, after complete removal of old loose flakes and Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.complete all as specified and directed. |
| 7 | M&L for preparation of old surfaces of walls and applying one coat of cement based paint including external scaffolding work including filling of cracks with approved crack fillercomplete all as specified and directed. Note : cement based paint shall be done by roller only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 8 | M&L for complete removal of existing treatment and preparation of surfaces of walls and applying two coats of cement based paint over a coat of cement primer complete all as specified and directed. Note : cement based paint shall be done by roller only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 9 | M&L for preparation of old painted steel surfaces exc. 10cm in width and girth and applying one coat of synthetic enamel paint,complete all as specified and directed. Note: Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 10 | M&L for Preparation of old painted wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 11 | M&L for preparation of old treated surfaces of wall exc 10cm width or girth applying one coat of exterior emulsion paint (weather proof) Note:-Exterior emulusion paint shall be done by roller only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 12 | M&L for complete removal of existing treatment, preparation of surfaces exc 10cm width or girth and applying two coat of exterior emulsion weather proof paint over a coat of cement primer complete all as specified and directed.Note : exterior emulsion paint shall be done by spray only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided.Complete all as specified and directed. |
| 13 | M&L for preparation of old wooden surfaces exc. 10cm in width and girth and applying one coat of filler coat with thin varnish or lacquer or shellar varnish and finishing coat with synthetic varnish complete all as specified and directed. |
| 14 | Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets. Complete all as specified and directed. |
| 15 | S&F for providing false ceiling with anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605mm with aluminium main tee, cross tee size 25x25x1.6 mm and aluminium wall angle size 25x25x1.8 mm fixed to wall hanging from soffits\trusses\bracking using adjustable supporting hanger compressing of GI wire 4mm thick with locking clip including Providing and fixing Non asbestos designer E-Board 4mm thick in ceiling fixed to snap grid as per manufacturers instructions complete all as sepcified and directed. |
| 16 | M&L for uprooting of wild trees such as grass/bushes etc from the roof / wall surfaces / AC sheets / soil pipes surrounding including its penetated roots with suitable cleaning chemical and making good to the damaged plaster by providing CM 1:3 and finish the surfaces to match with the existing surface complete all as specified and as direceted. |
| 17 | Taking down cement plaster on walls any description including raking out joints, hacking for key and scrubbing down with water etc, complete all as specified and directed. |
| 18 | M&L for rendering 15mm thick in CM (1:6) on internal surfaces of walls on brick/stone masonry/ concrete surface including finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for rendering 15mm thick in CM (1:4) mixed with water proofing compound @3% of total weight of cement used or as per manufacturer's instruction on external surfaces of walls on stone masonry/concrete surface or brick walls including finished the surface fair and even complete all as specified and directed. Note : WPC shall be measured & paid seperately under relavant item. |
| 20 | Supply only integral water proofing compound.Complete all as specified and directed. |
| 21 | M&L for rendering 5 mm thick in CM (1:3) on ceiling surfaces of including finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for preparation of newly plastered surfaces of walls exc 10 cm width or grirth and applying two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 23 | M&Lr for preparation of newly plastered surfaces of walls exc 10 cm width or grirth and applying two coat of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed. |
| 24 | M&Lr for preparation of newly plastered surfaces of walls exc 10 cm width or grirth applying three coats of white wash on wall complete all as specified and directed |
| 25 | M&L for Hacking out old broken glass (any thickness, size quality or description) from wooden frames or steel frames of stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified. |
| 26 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square panels or with wooden/steel beads not exceeding 0.5sqm each pane Complete all as specified and directed. |
| 27 | S&F for figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane and fixed complete all as specified and directed. |
| 28 | S & F in repairs galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with galvanised wire staples/screw in wooden/ steel frame of doors and windows.Complete all as specified and directed. |
| 29 | S & F in repairs Stainless steel Curtain rods 25mm dia with side Brackets complete all as specified and as directed. |
| 30 | S&F in repair 25 mm bore CPVC pipes SDR 11 pipes & Plain CPVC SDR 11 fittings and fixed complete to walls and ceiling or laid in floors including taking down existing GI/CPVC complete all as specified and as directed |
| 31 | S&F in repairs of CPVC pipes 20 mm dya SDR 11 & plian CPVC SDR 11 fittings in wall /ceiling or laying in floors taking down existing GI /CPVC pipes complete all as specified and directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and directed. |
| 33 | S&F for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering layer in cement mortar 1:4 complete all as specified and directed. |
| 34 | S&F Non skid ceramic tiles 7 to 8mm thick (square/rectangluar) area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4.Complete all as specified and directed. |
| 35 | M&L for Vitrified ceramic tiles 15mm thick (square/rectangular) dark Shade Shade/Double charged/ultra charged area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified & directed. |
| 36 | M&L for Vitrified ceramic tiles 10mm thick (square/rectangular) dark Shade Shade/Double charged/ultra charged area of each tile not exceeding 0.36 sqm in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick renderering in CM 1:4 complete all as specified & directed. |
| 37 | M&L for Granite(of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platorms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite including 15mm thick screed bed and incl its dismantling old existing granite complete all as specified and as directed. |
| 38 | Demolition of un reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (below & above ground level) complete all as specified and as directed. |
| 39 | M & L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) finished fair and even as in sub base flooring complete all as specifiead and as directed. |
| 40 | Demolition of brick work or stone/boulders masonry built in Cement Mortar.Complete all as specified and directed. |
| 41 | M & L for brick work in CM (1:6) using old size sub class 'B' bricks straight or curved on plan.Complete all as specified and directed. |
| 42 | M & L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4.Complete all as specified and directed. |
| 43 | S & F in repairs 15mm bore bib taps, brass chromium plated, screwed down, screwed for iron pipe complete all as specified and directed. |
| 44 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm long Complete all as specified and directed. |
| 45 | S & F in repair 15mm bore pillar taps brass chromium plated, screwed down, high pressure with or wihtout lettered hot or cold with long screwed shanks and fly nuts, screwed to iron pipe, fixed in repairs complete all as specified and directed. |
| 46 | S & F in repair 15mm bore chromium plated fancy type angle cocks/stop valves brass, (Concealed) screwed down high pressure with crutch or butterfly handle complete all as specified and directed. |
| 47 | S & F in repairs chromium plated 125mm shower rose with or without swivel joints any size including fixing to steel pipe or union Complete all as specified and directed. |
| 48 | S&Fin repair WHB vitreous china (flat back or angle back type ) any size ,including cutting for pinning in ends size 550x400 mm including brackets ,out let pipe ,coupling ,connection pipe 450mm and CP taps complete all as specified and directed. |
| 49 | S&F in repairs vitreous china wash down water closet (pedestal pattern) any colour with plastic seat and cover including PVC low level flushing cistern 10 ltrs capacity,flush pipe of polythylene of low or high density or PVC 32 mm dia , PVC connection 15mm size with PTMT nuts of length 450mm and Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including complete all as specified and directed. |
| 50 | S & F in repairs PVC low level flushing cistern 10 litres capacity, syphonic action type, white, as approved including ball valve float valve and handle, flush pipe as in repair complete all as specified and directed. |
| 51 | S & F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including waste coupling and waste pipe Complete all as specified and directed. |
| 52 | S&F in repairs 15mm bore wall Mixer Brass CP mixer for mixing hot & cold water screwed down for iron pipe Complete all as specified and directed. |
| 53 | S&F in repairs 15mm bore Pillar Tap Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed Complete all as specified and directed. |
| 54 | S & F in repairs wash down water closet (pedestal pattern) any colour of size 69 x 36 x 64 cm whitecomplete incl all fitting & fixtures complete all as specified and directed. |
| 55 | S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position Complete all as specified and directed. |
| 56 | S & F in repair 2 Way Bib Tap with Wall Flange complete complete with and including all fixing accessories Complete all as specified and directed. |
| 57 | S & F in repair Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed. |
| 58 | S & F corner shelf of dimension 22cm x 22cmx 7cm conical shape made of toughned glass, colour: Glossy, wall mounted.Complete all as specified and directed. |
| 59 | S&F in repairs PVC cabinet with door fitted with looking mirror size 422mm x 622mm Complete all as specified and directed. |
| 60 | Supply & fixing in repair vitreous china wash basin with padestal , white flat size 550x400mm incl bracket cutting for and pining in ends of brackets or erecting stand including PVC connection pipe 15 mm bore 450 mm long , waste coupling of PTMT, PVC waste pipe complete all as specified and directed. |
| 61 | S & F in repairs Tubular Towel rail 20mm dia, D type, 60cm long between flanges of brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats complete all as specified and directed. |
| 62 | S&F in repairs Tubular Towel ring 20mm dia, Ring type, 20cm of dia with flanges of brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats complete all as specified and directed. Please Enable Macros to View BoQ information |