Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Rates are exclusive of GST |
| 2 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 3 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 4 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 5 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 6 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 7 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (For Earth- green color ) |
| 8 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(for power & IP comp board circuit) |
| 9 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(for power & IP comp board circuit) ( Rate reference taken from Note-1) |
| 10 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 11 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 12 | Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specificationNo:WG-MA/BW(NOTE-1) |
| 13 | Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(NOTE-1) |
| 14 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(NOTE-1) |
| 15 | Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 16 | Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 17 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 18 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.. ((For POWER-7+GSR-1). |
| 19 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. (for AC-17) |
| 20 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 21 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.. (For POWER-7+AC-17+GSR-1). |
| 22 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 23 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 24 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. (TV socket). |
| 25 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(AC-17) |
| 26 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.. (For POWER-7+GSR-1) |
| 27 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..(TV=2) |
| 28 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit /casingn capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW(LIGHT -64, EXHAUST FAN-9) |
| 29 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 30 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG PW/CW |
| 31 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW |
| 32 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 33 | Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 34 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 35 | Supplying and erecting LED square / circular Max. 25 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 36 | Supplying and erecting Concealed type foot/step light Max. 5W having IP67. IK10 rated Pressure die cast housing having system lumens output of Min. 500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, SDCM<5, p.f. >0.95, operating range of 230-270V, surge protection of 2.5 kV, Life class of 25,000 Hrs. at L70B50, including driver by making necessary arrangement/recess in wall to make it flush with surface with 2 Year warranty. |
| 37 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 38 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 39 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. |
| 40 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 41 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 42 | Supplying, erecting & marking SPMCB 6A to 32A, D-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (NOTE-2) |
| 43 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 44 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 45 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MC |
| 46 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 47 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 48 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness,surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 49 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 50 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 51 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 52 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 53 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCBof 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 54 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 55 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specificationno. SW-SWR/MCCB |
| 56 | Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO |
| 57 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 58 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 59 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 60 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 61 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 62 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 63 | Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 315A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, singlephasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . |
| 64 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 65 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 66 | Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 67 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 68 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MSpipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 69 | Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard |
| 70 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB |
| 71 | Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. |
| 72 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 73 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring &connections etc. |
| 74 | Supplying, installation & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 40 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 75 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 76 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminiumconductor complete erecte d with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 77 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 78 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 79 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 80 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 81 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 82 | Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non-corrosive bond with required joints. As per specification no. EA-EP. |
| 83 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv |
| 84 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 85 | Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 86 | Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. |
| 87 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet,outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs.astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 88 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 89 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. Aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 90 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 91 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,2 core 2.5 sq. mm. COPPER conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/CU |
| 92 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 93 | Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB |
| 94 | Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/ HM (excluding luminaries) |
| 95 | Providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL. |
| 96 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 97 | Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete. |
| 98 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP |
| 99 | Supplying and erecting GI WIRE of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 100 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template,duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole). |
| 101 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 102 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm.stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 103 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). |
| 104 | Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PVSystem / Plant consisting Solar PV Poly Crystalline Panel (580-590 Wp X 86 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate,canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, signboard, two distinct earthing, lightning arrester, liaisoning charges, remotemonitoring system with maintaining card / chip for 5 years including net chargesfor RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract asper Specification no. ESD-RT-ONG. |
| 105 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 106 | Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 107 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 108 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 109 | Supplying and installation of Solar PV Module cleaning unit consisting of nozzles spray, necessary pipes, valves, post, electronic panel board concealed with weather proof cabinet, spreading water periodically for removal of dust, related motor pump, controller, timer and nozzles set suitable for covering 5 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area). |
| 110 | For item no. 4-8-8 for additional kW capacity, add Rs. 4000/- for every 5kW. |
| 111 | Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) having minimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V AC at each socket with 3.5\\"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification. |
| 112 | Supply, Installation, Testing and Commissioning 7.2 kW AC Electric Vehicle charger (suitable for 4 wheeler) having minimum IK08 & IP54 protection suitable for single phase, 230V AC, 50Hz, incoming and 1 nos. output having capacity of output current of 32A at 230V with Type two connector as perIEC 62196-2 , Interlocking arrangement & minimum 5 meter charging cable length, 3.5\\" TFT screen for human interface & LED light for status indication and metering for measurement of consumed energy having metering accuracy +/- 1%, one hour battery backup for server communication, emergency push stop button, with user interface by mobile application/QR Code/RIFD Card/Password Login and having short circuit, over & under voltage, overload, earth leakage ,Over temperature, surge protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification |
| 113 | Providing yearly subscription of payment gateway option for AC/DC EV Charger CMS (Charger management software) system for billing and payment gateway along with mobile application /android/IOS base app to facilitate charging, CMS should have ISO/IEC 27001:2003 certification. |
| 114 | Supply, Installation, Testing & Commissioning 4MP VF Bullet-1/2.7\\" 4Megapixel PS, CMOSImage Sensor, Max. 4MP(2688 × 1520)@30fps, H.265+ and H.264+triple-stream encoding,WDR(120dB), Day/Night(ICR), 3D-DNR, ROI, AWB, AGC, BLC, 2.7mm~13.5mm MotorizedLens, IR Range of 60 Mtrs, IP67, IK10, Micro SD Card, PoE, IVS: Tripwire, Intrusion, MotionDetection, Scene Change., UL, CE, FCC, RoHSImage Sensor 1/2.7\\" 4Megapixel progressive CMOS (0.9407 centimeters) Minimum Illumination 0.005 [email protected] (Color, 30IRE) 0.0005 [email protected] (B/W,30IRE) 0 Lux (IR on) Effective Pixels 2688 (H) ×1520 (V) Shutter Speed Auto/Manual, 1/3 s~1/100000s White Balance Auto/natural/street lamp/outdoor/manual/regional customLens 2.7mm~13.5mm Motorized Iris Type Fixed DORI Distance W# 64.0m (Detect) 25.6m (Observe) 12.8m (Recognize) 6.4m (Identify) T# 222.0m (Detect) 88.8m (Observe) 44.4m (Recognize) 22.2m (Identify) Video Compression H.265+/H.265/H.264+/H.264/H.264H; H.264B; MJPEG Angle of View Horizontal: 104°#27° Vertical: 55° #15° Diagonal: 124° #31° |
| 115 | Supplying ,erecting, commisioning & testing Screen (108Cm)/ 43 inch specification General of Screen size 108cm x(43inch) Screen type LED HD technology and resolution Full Hd TV 1920 x 1080 HDMI, 3 USB : 1 launch year 2018, connectivity features (static) Picture Engine Hyper real view angle 178Degree panel type A+ Digital noise video features PMI 300 clarity colour , contract, active noise reduction Dynamic colour Enhancer picture mode : 8 Modes(vivid , standar, Aps, Cinema , cricket game Expert 2 Picture :JPEG Digital Noise reduction Movies support in USB mode ,MPEGH 264 , recorder response Time 6.5ms, still image , wide colour enhancer (Plus), Film mode Cricket Audio features Number of speakers : 2 , Speaker Type : Down firing with Bass reflex . Sound technology: Dolby Digital plus Speaker Output RMS:20 W Warranty, Warranty Summary : 1 year, comprehensive and warranty Summary : 1year and 1 year additional on Panel. |
| 116 | Supplying erecting Testing & Commissioning Camera NVR 32 Channel System specification 32ch with 4K Real -time Live Preview max 320 Mbps incoming bandwidth with H 265 compression , Decoding support upto 4 x 4 k @ 30 , 8 ( 4 MP @ 200N VIF Version 2.4 conformance VCA Bearch and Smart for playback support 8 SAT AHDD upto sara 2 USB OJ 1 USB 3.0 |
| 117 | Supplying and Installation,Testing & Comissioning of surveliance internal HDD(hard Disk Drive) HDD Supply installation , testing and commissioning of Survilence internal HDD Recording capacity 4 TB. |
| 118 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 119 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification.No: WG-MA/CC. |
| 120 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG MA/CC. |
| 121 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification\ No. WG-MA/CC. |
| 122 | Supplying and installing cat-6 cable suitable for networking as per specification No: WG-COC/NC |
| 123 | Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 124 | Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG NAS/UTPC. |
| 125 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 126 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 127 | Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse andm indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK |
| 128 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 129 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/GBS |
| 130 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 131 | Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW |
| 132 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 133 | Supplying & erecting mains with 1x1.5 sq.mm H.F.F.R. copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 134 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 135 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 136 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 137 | Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 138 | Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary. |
| 139 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. (1 Bulkhaed in each lift shaft). |
| 140 | Supplying and erecting Exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specifcationno. FG-FN/EXF |
| 141 | Supplying, erecting & marking SPMCB 6A to 32A (B-series for Lighting) in provided distribution board as per specification No. SW-SWR/MCB |
| 142 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 143 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB (in each lift room 1 for 3-phase RCCB/ ELCB & 1 for 1-phase RCCB/ ELCB & 2 Nos. SP MCB) |
| 144 | Providing, erecting & commissioning RCCB of electro magnetic type with 30/100/300 mA sensitivity and having capacity of 63A. 4 pole complete as per specification No. SW-RCCB/RCCB |
| 145 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 146 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (form Generator to changeover switch) |
| 147 | Supplying and erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws in an approved manner. |
| 148 | SITC of Electric Traction Passenger Lift with 1299498· Rated capacity :- 10 Passenger/680Kg· Floors :- G+1 floor (2 Stops/2 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of mm wide x mm deep x 2250mm high· Lift shaft available having clear size of .1900mm wide x .1900mm deep,.......... mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings. |
| 149 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 150 | Providing and erecting Heat shrinkable out door termination kit for 11 kV (E) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT |
| 151 | Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 152 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 153 | Supplying & erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification No. CB-CIP |
| 154 | Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 155 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. |
| 156 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 157 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. |
| 158 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 159 | Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A, VA10 or 15, Class 0.5S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.5 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. |
| 160 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 27.8 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 290 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG |
| 161 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 140 kVA up to 180 kVAcapacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. By Redure Rates 10% Notes-1 |
| 162 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 163 | Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 100 mm diawith necessary fittings as per specification no. FF-PP |
| 164 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 165 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 166 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 167 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 168 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 169 | Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 170 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 171 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m in length,, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 172 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ |
| 173 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 174 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 175 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 176 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 177 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheetand angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\\" x 6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 178 | Providing Round bottom FIRE Bucket of 9 Litrescapacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook |
| 179 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint. |
| 180 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 181 | Supplying, installation, testing and commissioning of booster fire pump [BP]suitable for water discharge of 900 LPM at 35 m head driven by electricmotor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kWcapacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of castiron body & bronze/CI impeller with stainless steel shaft (SS410 grade),mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation on with IP 55 protection for enclosure, horizontal foot mountedtype with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required. (d)Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/BP |
| 182 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP)of cubical construction, floor mounted type, fabricated from minimum 2 mmthick CRCA sheet, compartmentalised with hinged lockable doors, with enclosureprotection class IP54, duly powder coated or painted with accessories dulypainted with two coats of synthetic enamel paint of fire red colour over a coat ofprimer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection withsuitable size solid copper busbar strip of adequate size for all power connectionshaving switchgears and accessories, mountings and internal wiring with adequatesize copper conductor cable, earth terminals, numbering etc. complete in allrespect, suitable for satisfactory operation of main fire pump and jockey(pressurisation) pumps (1working+1standby) with necessary accessories, wiring &cabling along with allied accessories with following incoming and outgoings,suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply asper specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby,alternate run per start in auto mode)comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomerand branches to motor SFU's, starters & outgoing terminals with necessaryaccessories like stainless steel nut bolts with spring washers for connections,mounted on required no of epoxy or porcelain support insulators of suitableratings etc.3. Individual pump TPN SFU having rotary handle with HRC fuses of suitablerating.Each 1823204. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP,O/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cablingrequired for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pump, jockey(pressurization) pumps in sequence with interlocking for operation of pumps asper specification with automatic/manual operation with selector switch &alternate run of standby Pumps consisting of relays, timers. sensors, annunciationwindow for fault indication, complete as per specification.8.Suitable capacity electric motor starters for all individual pumps with necessarypush buttons & indications.9. Siren of required capacity to be activated when main pump starts & alliedaccessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS.11. Spare HRC fuses minimum 2nos of each individual rating with requiredbakelite fuse holder for main & jockey fire pumps MFP=(1working), JP =(1working+1standby, alternate run per start in auto mode) complete panel, as perspecification no. FF-MFP/ECP |
| 183 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete |
| 184 | Supplying and erecting XLPEarmoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ceiling as per specification No.CB-LT/CU |
| 185 | Supplying, erecting testing and commissioning Manual Call Point with break glass, push button (Resettable Type) in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 186 | Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowingmultipl sounders to be activated wit CRCAenclosure complete as per specification no. FF-FAAS/HT |
| 187 | Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 188 | Supplying & erecting cast iron double flange butterfly valve of size 65 mm dia. complete as per specification no. FF-VL/BFV |
| 189 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 190 | Supplying and erecting 75/80 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS |
| 191 | Supplying and erecting cast iron double flange NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV |
| 192 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. APWCR/WC |
| 193 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 194 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 57 to 22 m and discharge from 120 to 900 litres. . per minute & pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 195 | Supplying, installing, testing and commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC |
| 196 | Supplying & erecting Water level controller 230/415 V, A.C. , Two way underground tank operation only. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail