| 1 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing, approved make as per directions of the Engineer-in-Charge : With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
| 2 | Providing Unskilled manpower for dismantling the exesting damaged false ceilling or other emergent work as per direction of Engineer-in-charge |
| 3 | Providing skilled manpower for dismantling the exesting damaged false ceilling or other emergent work as per direction of Engineer-in-charge |
| 4 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 5 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form: for Suspended floors, roofs, landings, balconies and access platform |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 9 | Brick work with FPS bricks of class designation 75 in Super structure up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 10 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 11 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand (Asian/Nerolac/berger or equivalent) and manufacture to give an even shade : Old work (one or more coats) |
| 12 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 13 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand (Birla/JK make or equivalent) and manufacturer, over the plastered wall surface to prepare the surface even and smooth completed) |
| 14 | Applying priming coats with primer of approved brand (Asian/Nerolac/berger or equivalent) and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 15 | Painting with synthetic enamel paint of approved brand (Asian/Nerolac/berger or equivalent) and manufacture of required colour to give an even shade one or more coat on old work. |
| 16 | Painting with aluminium paint of approved brand(Asian/Nerolac/berger or equivalent) and manufacture to give an even shade:One or more coats on old work |
| 17 | Painting of Existing old iron Chimney ( with ladder and its connected plateform) approx 20 m hight and 1.5 m dia at site, including form work(shuttering and proping etc.) , removing old paint, primer work, painting two or more coats of approved brand (Asian/Nerolac/berger or equivalent), complete(Labour T&P etc.) in all respect at site as per direction of Engineer-in-charge. |
| 18 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Steel/ wood/ Ceramic/ Gypsum work/sheets of roof by providing weather/ structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600,Upto 5 mm depth and 5 mm width |
| 19 | Supplying and fixing of 18W LED Light panel ceilling cutout 210x210mm of Havells (LHEBHEP71Z1W018) Make, and as per site requirement and directed by Engineer-in-charge. |
| 20 | Wiring for light Point /fan point /exhaust fan /call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch of ISI marked(Legrand Myirus/Havells Crabtree Athena or equivalent) , modular plate suitable G.I Box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable(Havells/Finolex/Polycab or equivalent) including ceiling rose etc as per site requirement and direction of engineer in charge: Group C |
| 21 | Wiring for circuit /sub-main wiring along with earthwire with the following size of FRLS PVC Insulated copper conductor single core cable of ISI Marked (Havells/Finolex/Polycab or equivalent) in surface/ recessed medium class steel conduit as per site requirement and direction of engineer in charge :2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire |
| 22 | Supplying and fixing of 100W Highbay LED light of Havells/ Orient/ Philips or its equivalent make at site as per direction of engineer- in-charge. Please Enable Macros to View BoQ information |