| 1 | Demolition of cement concrete (unreinforced) of any description and in any position, not otherwise specifically provided for, complete all as specified and directed. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises, complete all as specified and directed. |
| 3 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water including remaval of derbis up to 5 KM etc from site, complete all as specified and directed. |
| 4 | M&L for non skid ceramic coloured tiles of 7 to 8mm thick (square / rectangular), area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid/ fixed over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 5 | M&L for non skid ceramic coloured tiles of 7 to 8mm thick (square / rectangular), area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid/ fixed over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 6 | M&L for non skid ceramic coloured tiles of 7 to 8mm thick (square / rectangular), area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in dado/ skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick plaster in CM 1:4, complete all as specified and directed. |
| 7 | M&L for non skid ceramic coloured tiles of 7 to 8mm thick (square / rectangular), area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in dado/ skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick plaster in CM 1:4, complete all as specified and directed. |
| 8 | M&L for coloured glazed ceramic tiles of each size 300x200x7mm / 350x250x7mm / 450x350x7mm as on vertical surfaces of walls, dados, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4, complete all as specified and directed. |
| 9 | M&L for 10mm thick virified light shade ceramic tiles (square / rectangular), polished, area of each tiles not exceeding 0.36 Sqm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 10 | M&L for 10mm thick virified light shade ceramic tiles (square / rectangular), polished, area of each tiles not exceeding 0.36 Sqm, as in dados/ skirtings etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, fixed over and including 10mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 11 | M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and the like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including grinding and polishing with rounding to edges of stone slabs one edg complete, laid/ fixed over and including 10mm thick screed be/ plaster CM 1:4, complete all as specified and directed. |
| 12 | M&L for 10mm thick rendering on other than fair face of brick work or concrete surfaces in cement mortar 1:6, finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 13 | M&L for 15mm thick rendering into two layers consisting of 10mm thick in CM 1:4 followed by 5mm thick in CM 1:4 with using WPC on fair faces of brick work or concrete surface including finished the surface even and fair,complete all as specified and directed.Note :- WPC shall be measured and paid separately under respective item of this BOQ. |
| 14 | M&L for 5mm thick rendering on fair face of brick work or concrete surfaces of ceiling in cement mortar 1:3, finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 15 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed. |
| 16 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer and 2-3mm thick wall care putty, complete all as specified and directed. |
| 17 | M&L for preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed. |
| 18 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 19 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 20 | M&L for brick work with sub class ‘B’, old size bricks, straight or curved on plan exc 6 mtr mean radius, built in CM 1:6, complete all as specified and directed. |
| 21 | M&L for water proofing treatment to the sunken portion area of each sunken portion with removing of exiting treatment with demolition of existing floor of any type upto depth not exc 0.60 mtr including filling of floor with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates), WC & P/S trap and cleaning with wire brush, one coat of bitumen @ 1.70 Kg per Sqm, 15mm thick plaster in CM 1:4 on all sides portion, one 450mm long 32mm dia spout, water proofing powder @ 3% mixed by weight of cement, complete all as specified and directed. |
| 22 | S&F in replacement of WC (squatt pattern) including cement concrete bedding, size 580mm x 440mm including PVC 'P or 'S' trap, front and back inlet and with internal foot rests (excluding flushing cistern) including flush pipe and connector pices of PVC and removed old CI Pipe including demolition of PCC upto 450mm depth, complete all as specified and directed. |
| 23 | S&F in replacement of wash down water closet (Pedestal pattern), complete with Pedestal pan and 'P' trap including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. including PVC seat and cover for pedestal pan and CP Jet alongwith flexible tube/pipe, complete all as specified and directed. |
| 24 | S&F in replacement of PVC low level flushing cistern of capacity 10 ltrs, white with inlet, ball valve, float and handle including breckets, flush pipe of polyethylene of low or high density or PVC 32mm dia and connection to pipe, complete all as specified and directed. |
| 25 | S&F in replacement of wash basin, vitreous china (flat back or angle back type), size 550mm x 400mm including cutting for and pinning in ends of brackets or erecting stand including CP waste coupling of 32mm dia and PVC waste pipe of 32mm dia, complete all as specified and directed. |
| 26 | S&F in replacement of vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe) but including urinal spreader with PVC connection of 15mm size with PTMT nuts of length 450mm and PVC waste pipe of 32mm bore and CP waste coupling, complete all as specified and directed. |
| 27 | S&F in replacement of PVC connection of 15mm dia with PTMT nuts of length 600mm, complete all as specified and directed. |
| 28 | S&F in replacement of health faucet, CP, brass with 8mm dia and 1 mtr long flexible tube with wall hook, complete all as specified and directed. |
| 29 | S&F in replacement of CP Jets for EWC's with required size of jet pipe (flexible) and connections etc, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 30 | S&F in replacement of CP Jets for EWC's with required size of jet pipe (flexible) and connections etc, complete all as specified and directed. Please Enable Macros to View BoQ information |