| 1 | Supply and fixing of Addressable fire alarm panel pre wired- wall mounting panel with MCBs, terminals, relay board, push buttons, power supply, IO modules, battery set etc and addressable fire alarm panelas mentioned below :- suitable for 1 loop with required power/communication and IO modules. Self verify function for automatic testing of detectors. Automatic addressing of detectors.Autro Field Bus. User friendly backlit display 16x40- charactor alphanumeric display and operator controls. Surface mountin+F13g on wall. Rack mounting in directives and regulations. Approved according to CEN standards EN 54-2, EN 54-4 and EN 54-13, FM regulations (Factory Mutual) and maritime regulations (IMO/SOLAS and USCG). Communication ports: 2 Ethernet ports, 2 USB host ports (max. 100mA).1 serial port for the std detection loop communication protocol, 1 RS-232, RS-422 or RS-485 serial portfor communication with third party complete all as specified and as directed by engineer-in-charge. Make: Honey well, Agni and firex, Notifier, Simplex, Siemens and Bosch as approved by GE. |
| 2 | Supply and fixing of Addressable optical smoke detector with base (IS type) and required EX barrier BZ- 500 ( Qty of Ex Barrier: 4 Nos for WSA- B Area)for in use intrinsically safe areas EX zone 1 and 2 made of white polycarbonate plastic having alarm LED, IP 44, Approval: EN54/ATEX/IECex, deckhead mounting base for termination with mounting accessories, glands etc. complete all as specified and as directed by engineer-in-charge. Make:- Honey well, Agni and firex, Notifier, Simplex, Siemens and Bosch as approved by GE. |
| 3 | Supply and fixing of Addressable Manual Call Point Break Glass type (IS type) for use in intrinsically safe areas EX zone 1 and 2 and comprises the self verify function and built in short circuit isolator made of GRP material, IP 66, Approval: EN54/ATEX/IECex, deckhead moulting base for termination with mounting accessories, glands etc. complete all as specified and as directed by engineer-in-charge. Make:- Honey well, Agni and firex, Notifier, Simplex, Siemens and Bosch as approved by GE. |
| 4 | Supply and fixing of Addressable Manual Call Point Break Glass type (WP type) for use in safe area with Input Module one no. BN-300 the self verify function and built in short circuit isolator made of GRP material, IP 66, Approval: EN54/ATEX/IECex, deckhead moulting base for termination with mounting accessories, glands etc. complete all as specified and as directed by engineer-in-charge. Make:- Honey well, Agni and firex, Notifier, Simplex, Siemens and Bosch as approved by GE. |
| 5 | Supply and fixing of Addressable Horn Cum Strobe WP type: LED Red sound Db: 100db @ 1m material: ABS IP Protection: ip42 with all required mounting acccessories i.e. Metallic mounting box, glands etc. complete all as specifed and as directed by engineer-in-charge. Make:- Honey well, Agni and firex, Notifier, Simplex, Siemens and Bosch as approved by GE. |
| 6 | Supply and fixing of Multiway Field Explosion Proof Junction Box for loop cable material: Aluminium area classification zone-1,2, IIA/IIB IP Protection IP 65 or better approval PESO with mounting accessories etc. complete all as specified and as directed by engineer-in-charge. Make: FEPL/FCG/Eq./ equivalent as appved by GE. |
| 7 | Supply and fixing of Monitoring station latest monitoring PC-HMI (All in one, intel core i5 processor, 8 GB DDR RAM, 500GB HARD Disk, LED screen (HD) 21\\" (Resolution: 1920x1080 pixel) Accessories (Keyboard, Mouse, OS Windows 10, drivers, cable etc.) with latest HMI software latest PC Configuration shall be supplied which will be compatible with HMI Software complete all as specified and as directed by engineer-in-charge. Make:HP/Dell or equivqlent as approved by GE. |
| 8 | Tool and plants required for testing and maintenance services design engineering, consisting of project management, engineering and project documentation & FAT project management including :- An assigned single point of contact, order processing, scheduling, status reporting and coordination of project execution action to meet customer requirements. Engineering includes cabinet design mechanical and electrical, device configuration, logic programming and system testing. Documentation includes document list, cabinet mechanical layout and electrical drawings, Power calculations, cause & effect diagrams, bill of materials, field equipment outline and electrical connection drawings, system interconnect drawings, disk copy of system program, standard eqipment operation & maintenance manuals and other project related documents complete all as specified and as directed by Engr-in-Charge. |
| 9 | Supply and fixing of PVC insulated PVC sheathed stranded armoured copper conductor 2 x 1.5 sq mm (1 pair) FRLS Cable on surface, including connection and steel conduit not less than 32 mm dia with clamp, etc. complete all as specified and as directed directed by engineer-in-charge.Note:one pair of 2 cables shall be measured and paid as unit length. |
| 10 | Supply & fixing test cable tray perforated of 100 mm width, 50 mm height and of 14 gauge powder coated including coupler plate, bends, angle iron 40x40x5mm size at every one meter for support with wall etc, complete all as specified and directed directed by engineer-in-charge. |
| 11 | Excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtrs in depth for poles, laying of cable or pipes (where provided for protection of cable) or for fixing poles and stay and getting out, soft/loose soil including trimming the sides and forming bottom surfaces to the required level complete all as specified and as directed directed by engineer-in-charge. |
| 12 | Removal of surplus excavated soil to a distance n. Exc. 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed directed by engineer-in-charge. |
| 13 | Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cms thick in each layer of soil complete all as specified and as directed directed by engineer-in-charge. |
| 14 | Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultrasounding technique and necessary machine with and including HDPE pipe of dia 100mm suitable for 0.4 MPA working pressure complete all as specified and directed. Note :- The hard standing/road/Path damages done during execution of item shall be made good as per the existing specification and cost of same shall be deemed to be included in the unit rate quoted by the contractor. Rate quoted by contractor is also deemed to be inclusive of providing HDPE pipe of dia 100 mm. |
| 15 | Supply and fixing of LT UG XLPE insulated 1100 Volts grade heavy duty electric cables with aluminium contuctor, cross sectional area 10 sq mm x 3 core laying the cable from exsisting panel to DB complete all as specified and as directed by Engr-in-Charge. |
| 16 | Supply and fixing of Low density polyethylene (HDPE) pipes 25 mm bore of pressure rating 6 kg/sq complete all as specified and as directed by engineer-in-charge. |
| 17 | Supply and fixing of MCB distribution box epoxy coated double door TPN 4 way horizontal type for MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and as directed by engineer-in-charge. Please Enable Macros to View BoQ information |