| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 2 | M&L for point wiring One light point controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty casing capping on wall with accessories like elbow, tees etc fixed on wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed. |
| 3 | All as per items srl No 2 above but for fan point |
| 4 | All as per items srl No 2 above but for Bell point |
| 5 | All as per items srl No 2 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 6 | All as per items srl No 2 above but for One socket out let 5 Amps 5 pin on independent board |
| 7 | All as per item No 2 here in before but with single core multistranded cable of size 4.0 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge. |
| 8 | M&L for point wiring One light point controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed. |
| 9 | All as per items srl No 8 above but for fan point |
| 10 | All as per items srl No 8 above but for Bell point |
| 11 | All as per items srl No 8 above but for 2 way light point control by 2 way switch |
| 12 | All as per items srl No 8 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 13 | All as per items srl No 8 above but for One socket out let 5 Amps 5 pin on independent board |
| 14 | All as per item No 8 here in before but with single core multistranded cable of size 4.0 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge. |
| 15 | M&L for modular point wiring One light point controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed. all as specified and as directed. |
| 16 | All as per items srl No 15 above but for fan point |
| 17 | All as per items srl No 15 above but for Bell point |
| 18 | All as per items srl No 15 above but for 2 way light point control by 2 way switch |
| 19 | All as per items srl No 15 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 20 | All as per items srl No 15 above but for One socket out let 5 Amps 5 pin on independent board |
| 21 | All as per item No 15 here in before but with single core multistranded cable of size 4.0 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge. |
| 22 | Supply and fixing bell push flush type 5 Amps . |
| 23 | Supply and fixing switch piano flush type 5 Amps single pole one way. |
| 24 | Supply and fixing switch piano flush type 5 Amps single pole two way. |
| 25 | Supply and fixing socket out let 2 in 1 multi pin 5 Amps flush type universal |
| 26 | Supply and fixing switch piano 15 Amps one way 240 volts |
| 27 | Supply and fixing socket outlet in repair 2 in 1, 3 pin, 5 and 15 Amps socket outlet 240 volts. |
| 28 | Supply and fixing stepped type electronic fan regulator flush type on the phenolic laminated sheet etc as reqd complete all as specified and as directed |
| 29 | Supply and fixing modular bell push 6 Amps single module |
| 30 | Supply and fixing modular switch 6 Amps single module one way. |
| 31 | Supply and fixing modular switch 6 Amps single module two way. |
| 32 | Supply and fixing modular socket 6 Amps 5 pin double module. |
| 33 | Supply and fixing modular switch 16 Amps single module |
| 34 | Supply and fixing modular socket 6&16 Amps 5 pin double module. |
| 35 | Supply and fixing modular Fan step regulator 120W, two module |
| 36 | Supply and fixing Ceiling rose on PVC FRLS board size 65 X 50 mm three terminal complete all as specified and as directed |
| 37 | Supply and fixing Lamp Holder, PVC FRLS/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 38 | Supply and fixing in replacement for Elect bell AC 230 Volts single phase musical type complete all as specified and as directed. |
| 39 | Supply and fixing in replacement for bell push flush type 5 Amps . |
| 40 | Supply and fixing in replacement switch piano flush type 5 Amps single pole one way. |
| 41 | Supply and fixing in replacement switch piano flush type 5 Amps single pole two way. |
| 42 | Supply and fixing in replacement socket out let 2 in 1 multi pin 5 Amps flush type universal |
| 43 | Supply and fixing in replacement switch piano15 Amps one way 240 volts |
| 44 | Supply and fixing in replacement socket outlet in repair 2 in 1, 3 pin, 5 and 15 Amps socket outlet 240 volts. |
| 45 | Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and as directed |
| 46 | Supply and fixing in replacement Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal |
| 47 | Supply and fixing in replacement Switch socket combination 2 in 1, 5 A flush type |
| 48 | Supply and fixing in replacement modular bell push 6 Amps single module |
| 49 | Supply and fixing in replacement modular switch 6 Amps single module one way. |
| 50 | Supply and fixing in replacement modular switch 6 Amps single module two way. |
| 51 | Supply and fixing in replacement modular socket 6 Amps 5 pin double module. |
| 52 | Supply and fixing in replacement modular switch 16 Amps single module |
| 53 | Supply and fixing in replacement modular socket 6&16 Amps 5 pin double module. |
| 54 | Supply and fixing in replacement modular Fan step regulator 120W, two module |
| 55 | Supply and fixing in replacement Modular Switch socket outlet combination 3 pin 5 amp' flush type |
| 56 | Supply and fixing in replacement Modular Switch socket outlet combination 3 pin, 15 amp, flush type |
| 57 | Supply and fixing in replacement Ceiling rose on PVC FRLS board size 65 X 50 mm three terminal complete all as specified and as directed |
| 58 | Supply and fixing in replacement Lamp Holder, PVC FRLS/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 59 | Supply and fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps B curve type ,230 volts, 10 KA complete all as specified and as directed. |
| 60 | Supply and fixing in replacement of 3 pin,16 Amps plug top, 230 V AC complete all as specified and directed by Engineer in Charge. |
| 61 | Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories all as specified and directed. |
| 62 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete with all accessories all as specified and directed. |
| 63 | Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type white/WW with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 64 | Supply and fixing in replacement Bldg security LED light luminaire of 35 watt having IP 67 protection fitting of pressure die cast aluminium housing, operating voltage 140 V to 240 V with in built surge protection, touughned glass with fixing of GI bracket/pipe 40 mm bore including drilling, holding nuts & bolt 2 coat of red oxide paint on GI pipe and fixing with wall security light on building wall complete all as specified and directed by Engr-in-charge. |
| 65 | Supply and fixing in replacement of Energy efficient round recessed/surface mounted Spot/focus light not less than 5W LED warm white/red/green/blue down lighter with premium white powder coating and die cast aluminium and making necessary electric connection complete all as specified and as directed by Engineer-in-Charge. |
| 66 | S&F in replacement of old unsv LED 15 watt Environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head LED luminaire comprising of high brightness LEDs, IP54 protection complete all as specified and as directed. |
| 67 | S&F in replacement of old unsv LED Decorative wall light fixture made up of Polycarbonate, suitable for LED Bulb 09/12W(B-22 base) complete all as specified and as directed. |
| 68 | Supply and fixing in replacement of clear white/warm 12 watt LED Bulb, 240 Volt and suitable for batten fittings complete all as specified and directed by Engr-in-Charge. |
| 69 | Supply and fixing in replacement on off push 25A, two module and 25 A Socket with plate and box with fixing on existing wall or concealed in wall complete all as specified and as directed. |
| 70 | Taking down unserviceable ceiling fan/exhaust fan from its position and handing over to occupant for further disposal/ resue. |
| 71 | Hanging only repaired/new ceiling fan/exhaust fan any make and size held by occupant |
| 72 | M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC casing capping of size 25 mm (external) with wall thickness not less than 1.8 mm, ISI marked on wall including accessories like elbow, tees, etc fixed on wall or ceiling etc. complete including taking out old existing submain wiring as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC casing caping shall be measured & paid for as one length. |
| 73 | M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC casing capping of size 25 mm (external) with wall thickness not less than 1.8 mm, ISI marked on wall including accessories like elbow, tees, etc fixed on wall or ceiling etc. complete including taking out old existing sub main wiring as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC casing caping shall be measured & paid for as one length. |
| 74 | Supply, fixing, connecting & testing in replacement of sheet metal enclosures double door, Triple pole and neutral, 04 way TPN DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps, 415 Volt rating with IP-42 protection complete including taking down existing all as specified and directed. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 75 | Supply, fixing, connecting & testing in replacement of sheet metal enclosures double door, single pole and neutral, 04 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down existing all as specified and directed. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 76 | Supply, fixing, connecting & testingin replacement of sheet metal enclosures double door, single pole and neutral, 08 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down existing all as specified and directed. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 77 | Supply, fixing, connecting & testingin replacement of sheet metal enclosures double door, single pole and neutral, 12 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down existing all as specified and directed. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface |
| 78 | Supply and fixing in replacement of 415V, 10 KA 'C' curve miniature circuit breaker (MCB) of three poles and neutral current carrying capacity 40 to 63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 79 | Supply and fixing in replacement of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 80 | Supply and fixing in replacement of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 81 | Supply and fixing in replacement of 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 82 | Supply and fixing in replacement of 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral current carrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 83 | M&L for Earthing complete with GI steel earth plate eletrode 60 cm X 60 cm X 6.0 mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metres below level ground,connected to Gl iron or steel earth wire 4 mm dia (8 SWG) by means of nuts,bolts checks nuts and washers made of Gl iron or steel earth wire protected by Gl iron pipe 15 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6:) type C1, pre-cast RCC coverslab 30 cm X30 cm X 10 cm with one lifting handle made of 8 mm dia ms bar funnel wire mesh,20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges,necessary excavation and earth work in any type of soil complete all as shownin electrical plate No 3 of MES schedule part-I and testing after completion.Note - The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. Please Enable Macros to View BoQ information |