| 1 | M&L for 10mm thick plastering in CM 1:6 on fair faces of bricks or concrete surfaces (internal surfaces) finished even and smooth w/o using extra cement incl taking down cement plaster on brick or stone walls surfaces etc including raking out joints hacking for key scrubbing down with water and include for all necessary lowering, etc., removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plasteringcomplete all as specified and directed. |
| 2 | M&L for Preparation of new surface of wall and applying two coat of oil emulsion distemper over a coat of primer over 3mm thick wall care putty on internal walls surfaces complete all as specified and directed. |
| 3 | M&L for Preparation of new surface of wall and applying two coat of oil emulsion distemper over a coat of primer on internal walls surfaces complete all as specified and directed. |
| 4 | M&L for 15mm thick external plastering in CM (1:4) with water proofing compound on fair faces of bricks or concrete surfaces finished even and smooth w/o using extra cement taking down cement plaster on brick or stone walls surfaces etc including raking out joints hacking for key scrubbing down with water and include for all necessary lowering, etc., removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plasteringcomplete all as specified and directed. complete all as specified and directed. (Water proofing compound will measured and paid separately) |
| 5 | Supply only integral water proofing compound complete all as specified and directed. |
| 6 | M&L for preparation of new plastered surfaces of walls and applying two or more coats with 100% premium acrylic emulsion paint having VOC content less than 50 gms/litre and UV resistance as per IS 15489:2004, alkalie and fungal resistance, dirt resistance, exterior paint of required shade with silicon additives @ 1.43L/10sqm over and including priming coat of exterior primer applied at 0.9L/10sqm complete all as specified and directed by Engr-in-Charge |
| 7 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer ,as per manufacturer's specification. |
| 8 | M&L for 5mm thick plastering in CM 1:3 on fair faces of concrete surfaces (ceiling surfaces) finished even and smooth w/o using extra cement incl taking down cement plaster on brick or stone walls or ceiling surfaces etc including raking out joints hacking for key scrubbing down with water and include for all necessary lowering, etc., removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plasteringcomplete all as specified and directed. |
| 9 | M&L for Preparing of new plastered surface of ceiling surfaces and applying three coats of white wash complete all as specified and directed. |
| 10 | M&L for Preparing of new plastered surface of ceiling surfaces and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed. |
| 11 | M&L for Preparation of old decorated surafces by Washing, rubbing down and stopping of distempered and painted surfaces of wall and applying two coat of oil emulsion distemper(white/tinted/color) over 3mm thick wall care putty filling wherever required on internal walls surfaces complete all as specified and directed. |
| 12 | M&L for Preparation of old decorated surafces by Washing, rubbing down and stopping of distempered and painted surfaces of wall and applying one coat of oil emulsion distemper(white/tinted/color) over putty filling wherever required on internal walls surfaces complete all as specified and directed. |
| 13 | M & L for complete removal of existing treatment by Washing, rubbing down and stopping of distempered and painted surfaces of wall all as specified and directed, applying 3mm thick wall care putty on internal walls surfaces of complete wall and applying two coat of oil bound distemper(white/tinted/color) over a coat of primer on internal walls surfaces complete all as specified and directed. |
| 14 | M&L for Preparation of old decorated surface of wall and applying two coat of white wash on walls surfaces complete all as specified and directed. |
| 15 | M&L for preparation of old decorated plastered or unplastered surfaces,complete removal of existing treatment (washing, rubbing down and stopping of distempered and painted surfaces) with over external walls. Note : 1. Washing and Removal of existing treatment shall be carried out by mechanized means and by jet washing (90-150 bar) as required and directed by Engr-in-Charge |
| 16 | M&L for applying two or more coats on old surfaces with 100% premium acrylic emulsion paint having VOC content less than 50 gms/litre and UV resistance as per IS 15489:2004, alkalie and fungal resistance, dirt resistance, exterior paint of required shade with silicon additives @ 1.43L/10sqm over and including priming coat of exterior primer applied at 0.9L/10sqm complete all as specified and directed by Engr-in-Charge. Note:1. MOU between contractor and approved paint manufacturer shall be submitted by Contractor for Pre,during and Post work completion site inspections. |
| 17 | M&L for preparation of old decorated plastered surfaces of walls by washing, rubbingdown and stopping of distempered and painted surfaces and applying two coats of cement base paint,as per manufacturer's specification. |
| 18 | M&L for Preparing of old decorated plastered surface of ceiling surfaces and applying two coats of white wash complete all as specified and directed. |
| 19 | M&L for Preparing of old decorated plastered surface of ceiling surfaces and applying one coat of distemper oil emulsion complete all as specified and directed. |
| 20 | M&L for preparation of old painted wooden surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and directed. |
| 21 | M&L for preparation of old painted steel surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and directed. |
| 22 | M&L for writing letters and figures (Block, roman, italic or indian) not exceeding 30 cm high with synthetic enamel paint complete complete all as specified and directed. |
| 23 | Supply & laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 including fittings on walls/ceiling or laying in floors complete incl taking down or up steel tubing and connections including cleaning for refixing or removal to store 15mm bore complete all as specified and directed.(The rate quoted shall include the carting and disposing all the debris outside defence land as and when directed by the Engr-in-Charge) |
| 24 | Supply & laying of 25mm CPVC pipes SDR 11 & Plain CPVC SDR 11 including fittings on walls/ceiling or laying in floors complete incl taking down or up steel tubing and connections including cleaning for refixing or removal to store 20mm bore complete all as specified and directed. (The rate quoted shall include the carting and disposing all the debris outside defence land as and when directed by the Engr-in-Charge) |
| 25 | Supply & laying of 40mm CPVC pipes SDR 11 & Plain CPVC SDR 11 including fittings on walls/ceiling or laying in floors complete incl taking down or up steel tubing and connections including cleaning for refixing or removal to store 40mm bore complete all as specified and directed. (The rate quoted shall include the carting and disposing all the debris outside defence land as and when directed by the Engr-in-Charge) |
| 26 | S&F in repairs for in CPVC 20mm Brass Elbow (3/4 x 1/2) |
| 27 | S&F in repairs for in CPVC 20mm Brass Tee |
| 28 | S&F in repairs for in CPVC 20mm Male Brass Threaded Adaptor (MTA/ MBTA) |
| 29 | S&F in repairs for in CPVC 20mm Female Brass Threaded Adaptor (FTA/ FBTA) |
| 30 | Supply and fixed in repair Bib taps 15mm bore chromium plated cast copper alloy with crutch or butter fly handle screwed for iron pipe or for brass ferrulo and fixed complete all as specified and directed. |
| 31 | Supply and fixed in repair Angle stop cock 15mm bore with wall flange cast copper alloy complete all as specified and directed. |
| 32 | Supply and fixed in repair Stop cock fancy type chromium plated with long shank and cup (Concealed type) screwed down high pressure with crutch or butterfly handle screwed bot ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed. |
| 33 | Supply and fixed in repairs 15mm dia brass chromium plated swan neck pillar tap with single lever complete all as specified and direction |
| 34 | Supply and fixed in repair 15mm Brass CP mixer (three in one faucet) for mixing hot & cold water including three joints to steel pipes or union and plugging and screwing to wall complete all as specified and directed |
| 35 | Supply and fixed in repair Brass chromium plated shower rose 125mm with 450mm arm complete all as specified and directed. |
| 36 | Supply and fixed in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 37 | S&F in repair Corner glass shelf assembly consisting of 5.5mm thick sheet glass shelf with chromium plated bracket guard |
| 38 | Supply and fixed in repair Tubular towel rail 20mm dia(d) type 60cm long between flanges Brass chromium plated complete all as specified and directed. |
| 39 | Supply and fix 600x450mm beveled edge mirror of selected quality glass, with chromium plated brass screws or cup washers complete all as specified and directed. |
| 40 | Supply and fixed in repair Health faucet ABS Body mild steel chromium plated suitable for 15mm dia pipe with 1.25mtr long flexible tube and brass wall hook including making connections and fixed in position complete all as specified and directed. |
| 41 | Supply and fixed in repair PVC valveless, syphonic action type flush tank in repair,10 litre capacity with inlet ball valve, float & handle including brackets,flush pipes of PVC 32 mm dia for low level cistern, rubber cones complete etc complete all as specified and directed. |
| 42 | Supply and fixed in repair PVC connection 15 mm size with PTMT nut of length 600 mm, complete all as specified and directed. |
| 43 | Supply and fix for Grating CP 100mm size fixed to repair complete all as specified and directed. |
| 44 | Supply & fixed in repair vitreous china wash down water closet pan (English/Pedestal pattern), white connecting to trap and to flushing pipe front or back inlet etc complete all as specified and directed. |
| 45 | Supply and fixed in repair for Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 46 | Supply and fixed in repair wash hand basin, white flat back size 550 x 400mm including brackets, and pinning in ends of brackets for erecting stand etc complete all as specified and directed. |
| 47 | Supply and fixed in repair 32mm brass chromium plated waste fittings for WHB & Sink complete all as specified and directed. |
| 48 | Supply and fixed in repair 32mm waste pipe for WHB & sink complete all as specified and directed. |
| 49 | S&F rotational moulded polyethylene water storage tank (rectangular with closed top ) hoisted & fixed in position all as specified in SSR PT I capacity of tank 250 ltr including ball brass valves 20mm dia, high pressure, with polythene float and fly nut including dismantling of old unserviceable water tanks complete all as specified and directed. |
| 50 | S&F rotational moulded polyethylene water storage tank (rectangular with closed top ) hoisted & fixed in position all as specified in SSR PT I capacity of tank 1000 ltr including ball brass valves 20mm dia, high pressure, with polythene float and fly nut including dismantling of old unserviceable water tanks complete all as specified and directed. |
| 51 | S&F rotational moulded polyethylene water storage tank (rectangular with closed top ) hoisted & fixed in position all as specified in SSR PT I capacity of tank 500 ltr including ball brass valves 20mm dia, high pressure, with polythene float and fly nut including dismantling of old unserviceable water tanks complete all as specified and directed. |
| 52 | S&F rotational moulded polyethylene water storage tank (rectangular with closed top ) hoisted & fixed in position all as specified in SSR PT I capacity of tank 2000 ltr including Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends & ball brass valves 20mm dia, high pressure, with polythene float and fly nut including dismantling of old unserviceable water tanks complete all as specified and directed. |
| 53 | S&Fin reapir Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends complete all as specified and directed. |
| 54 | S&Fin reapir Gun-metal, globe or gate valves 40mm bore, with iron wheel head, screwed both ends complete all as specified and directed. |
| 55 | S&Fin repair Aluminium alloy wire cloth 0.45 mm nominal dia.of wire and average width of aperture 1.40 mm and and fixed with aluminium wire staples/wooden beads fixed to existing shutters of any description. |
| 56 | Supply and fixed in repair fancy type curtain rod 25mm dia with heavy duty brackets, both of SS 304 grade including stops, rollers etc complete all as specified and directed. |
| 57 | Supply and fixed in repair floor door stopper aluminium body with overall length 140mm complete all as specified and directed. |
| 58 | Supply and fixed in repair Door closer hydraulically regulated,designation No, 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed (aluminium) complete all as specified and directed. |
| 59 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exceeding 1.5 sqm each complete all as specified and directed. |
| 60 | Taking down chowkat with shutter(without taking off shutter from the frame) area exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and directed. |
| 61 | Supply and Fix for Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.Note: The complete fixing and making good of the connected walls shall be completed within 10 days from the start of taking down of existing doors/windows/ventilators.Rs 500/day shall be penalised in case of delay of work beyond 10 days. |
| 62 | Supply and Fix Powder coated aluminium window, doors and ventilator shutters fixed, openable or sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 63 | Supply and fix sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm each pane 4mm thick complete all as specified and directed. |
| 64 | Supply and fix Figured glass pin head type glazed with oil putty in square not exceeding 0.5 sqm in each pane 4mm thick complete all as specified and directed. |
| 65 | S&F aluminium grills DG-104 of Deco Grill/ Hindal 10 mm thick diamond shape with aperture 10.0cm for windows |
| 66 | Supply and Fix for Aluminium alloy wire cloth 0.45 mm nominal dia.of wire and average width of aperture 1.40 mm and and fixed with aluminium wire staples/wooden beads fixed complete all as specified and directed. |
| 67 | Material and Labour Cleaning and removing all scale and dirt, etc, from tanks of capacity from 250L (incl) to 500L (incl) and from mouths of circulating pipes, etc., incl disconnecting the tanks and reconnecting after cleaning. Date of cleaning shall also be required to be written on the cleaned tanks. |
| 68 | Material and Labour Cleaning and removing all scale and dirt, etc, from tanks of capacity from 1000L (incl) to 2000L (incl) and from mouths of circulating pipes, etc., incl disconnecting the tanks and reconnecting after cleaning. Date of cleaning shall also be required to be written on the cleaned tanks. |
| 69 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC FRLS conduit (medium grade) Concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) incl Sunken Iron Boxes / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing / plastering, applying wall putty incl 02 coats of distempering in disturbed surface with existing colour all as specified and directed complete all as specified and directed at site. |
| 70 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC casing & capping ( medium grade) not less than 25 mm width with fittings & fixtures including with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in color) incl cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing / plastering, applying wall putty incl 02 coat of distempering in disturbed surface with existing color all as specified and directed complete all as specified and directed at site. |
| 71 | All as per here and before item No-70 above but Concealed wiring in Existing Conduit . |
| 72 | All as per here and before item No-70 above but for one light point controlled by one two way switch |
| 73 | All as per item No. 70 above but for call bell point. |
| 74 | All as per item No. 70 above but one 3/5 pin socket outlet 5/6 Amps on same board. |
| 75 | All as per item No. 70 above but one 3/5 pin socket outlet 5/6 Amps but independent board with cable 1.5 Sqmm two run & 1.5 Sqmm one run of earth continuity. |
| 76 | All as per item No.70 here in before but for 5/15 Amps point on independent board with two runs of 2.5 Sqmm FRLSH grade PVC insulated unsheathed stranded Copper conductor and 2.5 Sqmm, FRLSH grade PVC insulated, unsheathed, stranded copper conductor as earth wire. |
| 77 | All as per item No. 71 above but one 3/5 pin socket outlet 5/6 Amps on same board. |
| 78 | All as per item No. 71 above but one 3/5 pin socket outlet 5/6 Amps but independent board with cable 1.5 Sqmm two run & 1.5 Sqmm one run of earth continuity. |
| 79 | All as per item No.71 here in before but for 5/15 Amps point on independent board with two runs of 2.5 Sqmm FRLSH grade PVC insulated unsheathed stranded Copper conductor and 2.5 Sqmm, FRLSH grade PVC insulated, unsheathed, stranded copper conductor as earth wire. |
| 80 | M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old sub main wiring with fittings & fixtures and all as specified. Note : Two runs of 2.5 Sqmm copper wire,one run of 2.5 Sqmm wire & one run PVC Conduit shall be measured as one unit |
| 81 | M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4.0 Sqmm and one run of 4.0 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old sub main wiring with fittings & fixtures and all as specified.Note : Two runs of 4.0 Sqmm copper wire,one run of 4.0 Sqmm wire & one run PVC Conduit shall be measured as one unit |
| 82 | M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Casing Capping of suitable size including taking down old sub main wiring with fittings & fixtures and all as specified.Note : Two runs of 2.5 Sqmm copper wire, one run of 2.5 Sqmm wire & one run PVC Casing Capping shall be measured as one unit |
| 83 | M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4 Sqmm and one run of 4 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Casing Capping of suitable size including taking down old sub main wiring with fittings & fixtures and all as specified.Note : Two runs of 4 Sqmm copper wire,one run of 4 Sqmm wire & one run PVC Casing Capping shall be measured as one unit |
| 84 | S&F Switch piano, flush type, single pole, one way 5 Amps, 240V complete all as directed by Engineer-in-Charge. |
| 85 | S&F Switch piano, flush type, single pole, one way 15 Amps, 240V complete all as directed by Engineer-in-Charge. |
| 86 | S&F Bell push Switch, flush type, single pole, one way 5 Amps, 240V complete all as directed by Engineer-in-Charge. |
| 87 | S&F Call Bell ,Ding-Dong ,single pole, AC, 230 Volts complete all as directed by Engineer-in-Charge. |
| 88 | S&F Socket outlet 2 in 1, 5 pin, 5 Amps flush type 240 Volt |
| 89 | S&F Socket outlet 2 in 1, 5 pin, 5/15 Amps flush type 240 Volt |
| 90 | S&F Ceiling rose,3 terminal PVC/poly carbonate isolated body. |
| 91 | S&F Lamp holder PVC/Polycarbonate, Angular type with back plate suitable for batten fittings. |
| 92 | Supply and fixing of Step type electronic Fan regulator socket type on the existing phenolic laminated sheet etc as required as existing type and size |
| 93 | Supply and fixing including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed. |
| 94 | Supply and fixing including connection of modular switch one way 16 Amps 1 Module complete all as specified and directed. |
| 95 | Supply and fixing modular Bell push 6A 1 Module complete all as specified and directed. |
| 96 | Supply & fixing including connection modular socket outlet 2 /3 pin 6 Amps 2 modules complete all as specified and directed. |
| 97 | Supply & fixing including connection modular socket outlet 2 /3 pin 6/16 Amps 2 modules complete all as specified and directed |
| 98 | Supply and fixing of Modular Fan regulator,120 watts |
| 99 | Supply and fixing white modular cover plate with frame 1 Module complete all as specified and directed |
| 100 | Supply and fixing white modular cover plate with frame 2 Module complete all as specified and directed. |
| 101 | Supply and fixing white modular cover plate with frame 3 Module complete all as specified and directed. |
| 102 | Supply and fixing white modular cover plate with frame 4 Module complete all as specified and directed. |
| 103 | Supply and fixing white modular cover plate with frame 6 Module complete all as specified and directed. |
| 104 | Supply and fixing white modular cover plate with frame 8 Module complete all as specified and directed. |
| 105 | Supply and fixing modular metal flush box 1/2 Module complete all as specified and directed. |
| 106 | Supply and fixing modular metal flush box 3 Module complete all as specified and directed. |
| 107 | Supply and fixing modular metal flush box 4 Module complete all as specified and directed. |
| 108 | Supply and fixing modular metal flush box 6 Module complete all as specified and directed. |
| 109 | S & F in repairs modular surface mounted plastic boxes 3/4 module for fixing of switch socket 6/16 Amps ISI marked complete all as specified and as directed |
| 110 | S & F in repairs modular surface mounted plastic boxes 6 module for fixing of switches, sockets and regulator etc ISI marked complete all as specified and as directed |
| 111 | S & F in repairs modular surface mounted plastic boxes 8 module for fixing of switches, sockets and regulator etc ISI marked complete all as specified and as directed |
| 112 | S&F MCB DB made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and din rail of SPN 4 way, 240 Volts double door fixed in wall , making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified |
| 113 | S&F MCB DB made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and din rail of SPN 8 way, 240 Volts double door fixed in wall , making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified |
| 114 | S&F MCB, SPN. 32 Amps rating 240, volt, 'C' series, 10 kA |
| 115 | S&F MCB, SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA |
| 116 | Disconnecting electrical wire from ceiling rose, taking down ceiling fan of any type/size and make, removing substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning, assembling the ceiling fan including testing hanging the ceiling fan as its own position, connection with point wiring complete all as directed by Engineer-in-Charge. |
| 117 | Taking out unserviceable geyser of any make and capacity for necessary repair/replacement including refixing the same in original position after repair including one coat of white synthetic enamel paint including preparation of old surface complete all as specified. (NOTE : spare parts shall be paid separately under supply only rate) |
| 118 | Supply and fixing 1x10 watt ( 2ft ) LED Batten indoor decorative type robust and high Translucent Serrated milky white diffuseries, with efficiency of 100 lm/W,Glare free extruded Batten suitable for Mirror LED lamps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed. |
| 119 | Supply and fixing High-quality design LED Tube light fittings with high quality PC diffuser 1x20 watt with enhances safety and reliable ,robust housing structure with efficiency of 100 lm/W ,decorative end caps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed. Please Enable Macros to View BoQ information |