Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m In all kind of soil upto 1.5m depth DSR 2.8.1 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m In all kind of soil upto 1.5m to 3.0m. depth DSR 2.26.1+2.8.1 |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m In all kind of soil upto 1.5m to 3.0m. depth DSR 2.26.1*2+2.8.2 |
| 4 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift DSR 2.25(A) |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR 2.27 |
| 6 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) DSR 13.6.1 |
| 7 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. DSR 4.13 |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. DSR 4.1.8 |
| 9 | Providing and injecting chemical emulsion for constructional antitermite treatment and creating a chemical barrier under and alround the column pits. Wall trenches basement Excavation Top surface of plinth filling Junction wall and floor along the external perimeter of binding expansion joints, surrounding of pipes and conduit etc complete (plinth area of building at ground floor only, shall be measured as per 6313 (Part II 1981) Excluding GST. Aldrine emulsifiable concen-trate any other approved material such as Heptrachlor or Chlordance will be used. The rate of application of chemical emulsion shall be as follows: (1) Treatment for Masonry 8 foundation 5 liters per sqm. (2), Back fill in immediate contact with foundation 7.50 liters per sqm. (3) Treatment of top surface of Plinth fillings 5 liters / sqm. (4).Treatment of Soil along External perimeter of Building 7.50 liters/ sqm. (5). Treatment of soil under Apron along with external perimeter 5 liters / sqm |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for (a) Suspended floors, roofs, landings, balconies and access platform DSR 5.9.3 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers DSR 5.9.5 |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for (c) Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for (d) Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 |
| 14 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 5.1.2 |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). M-20. (LINTEL) DSR 5.3 |
| 16 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone M-20.(COLUMN) DSR aggregate 20 mm nominal size derived from natural sources)5.2.2 |
| 17 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank DSR 5.33.2.2 |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in .foundation and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.1.2 |
| 20 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (Zone III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). DSR 4.1 |
| 21 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. DSR 4.13 |
| 22 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2 |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.4.1 |
| 24 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR 22.7.1 |
| 25 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DSR 9.21.1 |
| 26 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only DSR 9.22.1 |
| 27 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood |
| 28 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by welding DSR 9.48.1 |
| 29 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge Fabrication of HOLD FAST DSR 10.31 |
| 30 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) DSR 10.15.1 |
| 31 | Providing and fixing fly and Mosquito proof stainless steel grade 304 wire mesh gaugewith 0.5 mm dia wire and 1.4 mm wire aperture DSR 9.51.2 |
| 32 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides DSR10.29.2 |
| 33 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia DSR 9.46.3 |
| 34 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood DSR 9.1.1 |
| 35 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22A.6 |
| 36 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) [Plinth Plaster] DSR 13.5.1 |
| 37 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.4.2 |
| 38 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) DSR 13.5.2 |
| 39 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of ppropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge DSR 13.76 |
| 40 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate [AT APRON] DSR 11.3.1 |
| 41 | Laying trimix hardner topping with mixing compound @ 2 liter per 50 kg of cement or as per manufacture's specification. DSR MR |
| 42 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. DSR 11.6.1 |
| 43 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING] DSR 11.41.2 |
| 44 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN SKIRTING] DSR 11.47.2 |
| 45 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. [IN FLOORING] DSR 11.26.1 |
| 46 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [IN SKIRTING] DSR 11.27 |
| 47 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour and shade Area of slab upto 0.50 sqm DSR 8.2.2.2 |
| 48 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete DSR 11.37 |
| 49 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete DSR 11.37 |
| 50 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture DSR 13.48.3 |
| 51 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture DSR 13.48.2 |
| 52 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). DSR 13.47.1 |
| 53 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . DSR 13.41.1 |
| 54 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.8 |
| 55 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). DSR 10.30.1 |
| 56 | Providing & fixing stainless steel sliding door bolts ISI marked required colour or shade with nuts and screws etc complete.250x16 mm M.R. |
| 57 | P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc complete.250x10 mm M.R. |
| 58 | Providing and fixing Stainless Steel handles ISI marked to required colour or shade with necessary screws etc complete. 150mm M.R. |
| 59 | Providing and fixing stainless steel hanging floor door stopper with necessary screws etc. complete. Twin rubber stoper DSR 14.34 |
| 60 | Providing and Fixing of Door slincer including necessary screws etc complete (M.R.) |
| 61 | Supplying and stacking at site cinder filling in SUNKEN AREAetc complete as per direction of E/I MR |
| 62 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) DSR 22.3 |
| 63 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. DSR 10.3 |
| 64 | Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) DSR 10.28 |
| 65 | Chequerred precast cement concrete tiles 20 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). DSR 11.20.1 |
| 66 | Supply ,laying and fixing of polycarbonate sheet etc complete as per direction of E/i |
| 67 | Writting and Letter naming of building name including supply of material labour T&p etc complete as per direction E/I |
| 68 | Providing and laying of 80mm thick interlocking cement concrete tiles (30 Mpa) including levelling and dressing of suface to required level and slope, filling joints with local sand including the cost of labour, Material and T & P etc. required for proper complition of work as directed by Engineer-in-charge.16.91.2 |
| 69 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). [DSR-16.75] |
| 70 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. DSR- 16.46.1 Using grade 'A' sealing compound. |
| 71 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. [DSR-16.1] |
| 72 | Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. |
| 73 | Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 DSR 16.78.2 |
| 74 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors.DSR 4.1.6 |
| 75 | Providing and fixing in position pre-moulded joint filleProviding and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charger in expansion joints.DSR 16.45 |
| 76 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.DSR16.46.1 |
| 77 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Light Point) DSR 1.10.3 |
| 78 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Fan Point) DSR 1.10.3 |
| 79 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. DSR 1.10.3 |
| 80 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Plug and conduit) DSR 1.10.3 |
| 81 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Plug and conduit)1.14.1+1.31 |
| 82 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. DSR 1.14.3 |
| 83 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire DSR 1.14.4 |
| 84 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire DSR 1.14.10 |
| 85 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. DSR 1.14.2 |
| 86 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. DSR 1.14.1 |
| 87 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15 |
| 88 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. DSR 5.18 |
| 89 | Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole6 - 32 amps.Cat. A DSR 2.10.2 |
| 90 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA) DSR 2.14.2 |
| 91 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) DSR 2.14.3 |
| 92 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4 way (4 + 12), Double door DSR 2.5.1 |
| 93 | Supply and fixing of single pole MCB blanking plate DSR 2.10.1 |
| 94 | Supply, Installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class of installation B, 3 nos. blades, 30 cm long down rod, 2 nos,canoples, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/M/W) minimum 6.00, ait delivery minimum 210 Cum.min. 350 RPM ( TOERANCE AS PER is : 374-2019), THD less than 10%, remote or electric regulator unit for control and all remaining accessories including safety pin, nut bolts, washers, temperature rise -75 degree C (max), insulation resistance more than2 mega ohm, suitable for 230 v,50Hz, single phase AC, Supply earthing etc. complete as required. DSR 9.1 |
| 95 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep DSR 1.50.1 |
| 96 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 50 sqmm 3.5 core DSR 9.1.22 |
| 97 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 10 sqmm 2.0 core DSR 9.1.2 |
| 98 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 6 sqmm 2.0 core DSR 9.1.1 |
| 99 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 70 sqmm 3.5 core DSR 9.1.23 |
| 100 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 300 sqmm 3.5 core DSR 9.1.30 |
| 101 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required 2 Pair DSR 1.18.2 |
| 102 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. DSR 1.19 |
| 103 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet DSR 1.24.6 |
| 104 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet DSR 1.24.7 |
| 105 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required 75mm X 75 mm X 60mm Deep DSR 1.22.1 |
| 106 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm) DSR 1.27.1 |
| 107 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR 1.26 |
| 108 | Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes. DSR 1.51 |
| 109 | Supply and installing of following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 450mm width x 62.5mm depth x 2.0mm thickness DSR 4.1.10 |
| 110 | .Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer M.R. |
| 111 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properly etc. complete as required. M.R. |
| 112 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. DSR M.R. |
| 113 | Supply & fixing ofrecess/Surface/Pendent mounting round 12 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects..Cat. AA MR |
| 114 | Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. M.R. |
| 115 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge 50 Sq.mm MR |
| 116 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.2mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mm Phase to neutral-minimum 15mm L.T.PANEL Incoming : One (1) No 200 A 4 poleMetering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No.200 A, TPN aluminimum bus bar of suitable length.Outgoing : Phase indication lamps on each outgoing to be provided.100Amps TPN - 1No. 63Amps TPN - 3Nos OR outgoing as per site requirment |
| 117 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.2mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mm Phase to neutral-minimum 15mm SUB DISTRIBUTION BOARD 6 Way VERTICAL TPN Incoming 80 amp TPN MCB 1 No. Outgoing: 40 amp TP MCB 1 No. 32 amp SP MCB 3 No. |
| 118 | Supply & fixing of 7/9 W LED BULB complete in all respect. Make:C&S Electric or Eq DSR N.S |
| 119 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X20/22 watt LED tube light fitting complete including tube on surface complete in all respect. Make:C&S Electric or Eq DSR N.S |
| 120 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX |
| 121 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4 way (4 + 12), Double door DSR 2.5.1 |
| 122 | Supply and fixing of single pole MCB blanking plate CAT ADSR 2.10.1 |
| 123 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep DSR 1.50.1 |
| 124 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required10 sqmm 2.0 core DSR 11.1.2 |
| 125 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm Dia DSR 19.6.1 |
| 126 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.2 Pair DSR 1.18.2 |
| 127 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. DSR 1.19 |
| 128 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. D Telephone socket outlet DSR 1.24.6 |
| 129 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. D TV antenna socket outlet DSR 1.24.7 |
| 130 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required 75mm X 75 mm X 60mm Deep DSR 1.22.1 |
| 131 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm) DSR 1.27.1 |
| 132 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR 1.26 |
| 133 | Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes. DSR 1.51 |
| 134 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 150 mm Dia DSR 15.13.4 |
| 135 | Supply and installing of following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 450mm width x 62.5mm depth x 2.0mm thickness DSR 4.1.10 |
| 136 | Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. DSR M.R. |
| 137 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properly etc. complete as required. DSR M.R. |
| 138 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. DSR M.R. |
| 139 | Supply & fixing ofrecess/Surface/Pendent mounting round 12 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Cat. AA DSR |
| 140 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200mm sweep DSR (i) |
| 141 | Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. DSR M.R. |
| 142 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge 50 Sq.mm DSR |
| 143 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR 17.1.1 |
| 144 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. European type W.C. pan with white plastic seat and lid.Make- Cera,Hindware. DSR 17.1.1 |
| 145 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. DSR 17.7.4 |
| 146 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm DSR 17.10.1.3 |
| 147 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe a) 32mm dia DSR 17.28.1.1 |
| 148 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe b) 40mm dia DSR 17.28.1.2 |
| 149 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 |
| 150 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. DSR 17.73.2 |
| 151 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms DSR 17.71 |
| 152 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. DSR 17.22 A |
| 153 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredc) Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern DSR 17.4.3 |
| 154 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade DSR 8.10.2 |
| 155 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work 110 mm O.D MR |
| 156 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work 90 mm O.D MR |
| 157 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal . size). Including cost of cutting holes & making good the walls etc. a) for 100mm dia pipe. DSR 17.37.1 |
| 158 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal . size). Including cost of cutting holes & making good the walls etc. b) for 75mm dia pipe. DSR 17.37.2 |
| 159 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. S.NO 35 |
| 160 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 90 mm S. NO 37 |
| 161 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 110 mm |
| 162 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 75/90 mm S. NO 38 |
| 163 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735 Size 110 mm |
| 164 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 90x90x90 mm S.NO 39 |
| 165 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735 Size 110x110x110 mm |
| 166 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 90 mm S.NO 41 |
| 167 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 110 mm |
| 168 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 169 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.a) 110mm DSR 12.43.2 |
| 170 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(Internal work) Exposed on wallna) 25mm dia nominal bore (medium duty) DSR 18.7.3 |
| 171 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(Internal work) Exposed on wall b) 32mm dia nominal bore (medium duty) DSR 18.7.4 |
| 172 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.a) 15mm dia nominal bore DSR 18.8.1 |
| 173 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.b) 20mm dia nominal bore DSR 18.8.2 |
| 174 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.a) 15mm nominal bore DSR 18.21.2.1 |
| 175 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore DSR 18.49.1 |
| 176 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.a) 15mm nominal bore DSR 18.51.1 |
| 177 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931a) 15mm nominal bore DSR 18.53.1 |
| 178 | Providing and fixing gun metal gate valve with wheel of approved quality.a) 25mm dia nominal bore DSR 18.17.1 |
| 179 | Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore DSR 18.16.1 |
| 180 | Providing and fixing brass stop cock of approved quality. b) 20 mm nominal bore DSR 18.16.2 |
| 181 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and base support for tank.1000 litres capacity |
| 182 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. DSR 2.10.1.2 |
| 183 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work 160 mm O.D MR |
| 184 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work 200mm diameter MR |
| 185 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. a) 100mm diameter S.W. Pipe DSR 19.2.1 |
| 186 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. b) 150mm diameter S.W. Pipe DSR 19.2.2 |
| 187 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. c) 200mm diameter S.W. Pipe DSR 19.2.3 |
| 188 | Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 150 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. a) 150 x 100 mm. size P type With bricks class 150 conforming to IS : 4885 DSR 19.4.1.2 |
| 189 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 150 (i) For Sewer Line DSR 19.7.1 |
| 190 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia DSR 18.8.6 |
| 191 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 100 mm dia DSR 18.8.7 |
| 192 | Supplying Installation testing & Commissioing of Butterfly Value PN-16 slim seal standard lever operated type as per design standard IS:1395 or BS:5155 with required flanges,nut,bolts etc. Complete in all respects. 100 mm DSR 18.11.5 |
| 193 | Supplying Installation testing & Commissioing of Butterfly Value PN-16 slim seal standard lever operated type as per design standard IS:1395 or BS:5155 with required flanges,nut,bolts etc. Complete in all respects. 80 mm DSR 18.11.4 |
| 194 | Supplying Installation Commissioning of dual plate Non Return Value of following sizes PN-10 as per design standard IS:5312 or BS:1868 with companion flanges, nut, bolts etc. Complete in all respect.150 mm DSR 18.14.4 |
| 195 | Supplying Installation Commissioning of dual plate Non Return Value of following sizes PN-10 as per design standard IS:5312 or BS:1868 with companion flanges, nut, bolts etc. Complete in all respect. 100 mm DSR 18.14.5 |
| 196 | Supplying Installation testing & Commissioning of Manual Swing type Fire Hose Reel IS:444 complete with heavy duty reel, 19 mm dia 30 Mtr. Long. 2 ply polyster yarn braided rubber pressure hose, Red colored, SS jet nozzle 25 mm isolating value and all other necessary fixing accessories complete in all respect. DSR 18.17.2 |
| 197 | Supplying Installation testing & Commissioning of 25 mm Air Release valve gunmental having rubber ball and with 25 mm BSP threaded male inlet including necessary accessories and connections complete in all respect. MR |
| 198 | Supplying Installation Commissioning of 25 mm Ball valve PN-1 gunmental as per IS:778 including necessary accessories and connections. DSR 18.18.1 |
| 199 | Providing / Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted \\"FIRE\\" in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. DSR MR |
| 200 | Supplying fixing of Fire hose, RRL hose jacketed with circular woven synthetic fibre conforming to IS:636.88 63 mm dia X15 Mtr. Long with S.S. heavy duty, 63 mm, Painr of male and female instantaneous couling having IS: 903 mark and duly S.S. wire wounded. DSR 18.16.2 |
| 201 | Supplying fixing of S.S. Branch pipe, short type with 63 mm male instantaneous intel, male threaded outlet, fitted with 15 mm bore nozzle having IS:903 mark. Gun Metal DSR 18.18.1 |
| 202 | Providing / Fixing of Fire Fighting pump set suitable for automatic operation consisting of the following as per the specification. a) Horizontally mounted, centrifugal type single/multi stage fire pump having cast iron body, bronze impeller, stainless steel shaft and capable of delivering 450 LPM, 7.5 H.P against a total head of 52 mtrs. Complete with pressure gauge & gun metal cocks on delivery side including bypass arrangement. Terrace pump DSR 18.4.2 |
| 203 | Supplying Installation testing & Commissioning of vertical air vessel fabricated from 6 mm thick MS plate with dished ends 250 mm dia DN 1.2 m high common for fire and jockey pump complete with spring loaded safety valve. Test pressure 12 kv/Sq.mm) DSR 18.2 |
| 204 | Supplying Installation Commissioning of pressure Gauge ranging from 0 to 14 kg. per sq.mm ISI marked from approved manufactures complete in all respect. MR |
| 205 | Supplying fixing of Cast iron body 63 mm dia male instantaneous intel coupling with housing cabinet (500X400X400 for 2 way and 600X400 for 4 way) cap and chain for fire brigade correction conforming to IS:904 and making connection with fire fighting pipe or underground water tank completing the work in all respect as per the directions of the Engineer-in-charge. (FIRE BRIGADE CONNECTION) Four way connection (4 way) DSR 18.19.2 |
| 206 | Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprising of: a) One 63 amp. TP-NL M.C.C.B. with rotary handle of beacking capacity 35 KV. b) One Volt meter (0-500 V) with selector swich. c) One set including lamps. MR |
| 207 | Supplying and laying of Insulated PVC sheathed, Steel Aromed, Copper Aluminium Conductor, 1100V grade Powder Cable. The cable shall be laid in tray / in trenches/on wall/ floor etc. As required (Approx quantities only)2 crore x 1.5 sq.mm Cu Cable MR |
| 208 | Supplying and laying of Insulated PVC sheathed, Steel Aromed, Copper Aluminium Conductor, 1100V grade Powder Cable. The cable shall be laid in tray / in trenches/on wall/ floor etc. As required (Approx quantities only)3.5 crore X 25 sq.mm AL Cable MR |
| 209 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.150 sq. mm 3-1/2 core MR |
| 210 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.50 sq. mm 3-1/2 core MR |
| 211 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc35 sq. mm 3-1/2 core MR |
| 212 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc10 sq. mm 4 core MR |
| 213 | Supplying and fixing of Self Glow Exit signage for stairs and exists Complete in allrespects MR |
| 214 | Supply and fixing of Fire man axe etc complete as per direction of E/I MR |
| 215 | Supply and fixing of Pressure Switchetc complete as per direction of E/I DSR 18.22 |
| 216 | Supply & fixing of Single way landing/Hydrant / Yard Hydrant valve 63 mm dia.gun metal instantanuous with female coupling with chain etc. complete. DSR 18.10.1 |
| 217 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head. DSR 18.3.5 |
| 218 | Supplying Installation Commissioning Intelligent Addressable 2 loop fire alarm control panel is able to connect 250 devices (Detector or Module) per loop in any combination with 20% spare address for detector in each loop should have min. 854 char LCD multi-line QVGA LCD display complete with inbuilt additional seven customized pregrammable function switch for direct activation of any device or control along with three programmable LED's indication along with 9A power supply inbuilt min three Notification appliance circuit with sufficient power supply to drive sounder cum strobe unit along with inbuilt 50 AH UL listed battery charger along with required SMF batteries for 24 hours in normal condition. DSR17.2.1.2 |
| 219 | Supplying Installation testing & Commissioning Intelligent Addressable photoele smoke detector with base as per specification with true alarm photo0 sensing technology selectable sensitivity from 0.2% to 3.7% / Ft, obscuration support digital communication and magnetically operated functional test.DSR17.2.4 |
| 220 | Supplying Installation testing & Commissioning Intelligent Addressable type heat Dectector along with base as per specification rate of rise temperature range is at 8.3 dgree c/ 11.1 dgree c per min and fixed temperature sensing is independent of rate of rise sensing to operate at 57.2 dgree c/68 dgree c support digital communication and magnetically operated functional test.DSR17.2.9 |
| 221 | Supplying Installation testing & Commissioning of Remote red LED alarm indicator on single gauge stainless steel plate.DSR17.2.5 |
| 222 | Supplying Installation testing & Commissioning of Intelligent Addressable Manual Call points-double action Break Glass cum pull station suitable for wall/column mounting.DSR17.1.4 |
| 223 | Supplying Installation testing & Commissioning of Intelligent Addressable Hooter cum multi carriar strobe, Unit as per specifications and customization of intensity selection as 15, 30, 75 or 110 cd of strobe unit is possible by panel. Sounder sum strobe will be driven by supervised 24 V DC input and will give 70 db output at 3 m strobe unite will be synchronized 1 Hz strobe flash rate for better evacuation in complete facility.DSR17.1.7 |
| 224 | Supplying Installation testing & Commissioning Intelligent Addressable single Addressable Control Relay Module-Form \\"C\\" contact type.DSR17.2.10 |
| 225 | Supply laying testing & Commissioning of 2 corex 1.5 sr.mm single standard copper conductor, PVX insulated armoured cable.DSR17.5.1 |
| 226 | Supply and fixingof C02 type fire extinguisher4.5 kg. capacity each (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completionof work..MR |
| 227 | Supply and fixingof fire extinguisher,ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completionof work.MR |
| 228 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 19.15.1 |
| 229 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 19.19.2.2 |
| 230 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually.23.1.1.1 |
| 231 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 23.4.2 |
| 232 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 23.5 |
| 233 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 23.6 |
| 234 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. 23.7 |
| 235 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. 23.8 |
| 236 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 150mm diameter S.W. Pipe 19.1.2 |
| 237 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) all around of S.W. Pipes including bed concrete as per standard design. a) 150mm diameter S.W. Pipe 19.2.2 |
| 238 | Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.a) Inside size 60x60 cm & 90 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. 19.7.1.1 |
| 239 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. DSR 5.4 |
| 240 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. DSR 5.2 |
| 241 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required. DSR 5.15 |
| 242 | The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification.interlocking, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification.Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention as mention in BOQ. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA.INCOMING 1 Nos. 400 Amp FP MCCB 1 Nos. 125 Amp ACB BUSBARS 1 Nos. 500 Amp TPN busbars of aluminium alloy as per SLD.AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's. Load Management through PLC Contactor for Load Management System Buscoupler switching.Interlocking. OUTGOING 4 Nos. 125 Amp TP MCCB 4 Nos. 63 Amp TP MCB 3 Nos. 40Amp TP MCB INSTRUMENTS 3 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers.3 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).3 Sets auto trip indicating lamp .Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams.RELAYS AS PER SLD MR |
| 243 | Providing, erecting, testing & commissioning approved make oil immersed naturally ONAN cooled, double wound, core type outdoor copper wound 11 kV/ 433 Volts Step Down Transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed and Off Load Tap Changer continuously rated for a full temperature rise in oil not exceeding 40 deg. C at maximum ambient temp. Of 50 deg. C complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with I.S. 1180 LEVEL 2 standards OFF load tap changing range steps -10% to 5% on H.V in steps of 2.50% .and L.V. for variation should be provided The H.V. shall be connected delta & secondary with star connection. The transformer should have cable-end boxes on H.T. side & on L.T. side suitable for bus duct or cables as per requirement complete with test certificates from manufacturers. Losses As per IS 1180 LEVEL-2.1. Coservator with plain oil level gauge and oil drain plug 1nos.2. Top filter valve 1 Nos.3. Bottom filter-Cum-drain valave 1Nos..4. Rating and diagram plate 1nos.6. Thermometer pockets 1Nos.7. Lifting Lugs 2/4 Nos.8.Air release plug 2/4 Nos.9. Bi-directional rollers 4Nos.10.Jacking pads 1Nos.11.Presure relese valve 1Nos.12. Separate Bare LV neutral 433V 13. Detachable/Fixed type radiators 1Nos.14. Magnet Oil level gauge 15. Oil temperature indicator 1Nos.16. Winding temperature indicator 1Nos.17. Marshlig Box single window 1No.18. Double flot buchholz's relaywith alarm and trip contact.COPPER WOUND 200KVA 11/.433V MR |
| 244 | Supply & fixing of 1.5 mtr GI inclined wall braket Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) on wall including the cost fastner,nuts & bolts and Required T&P complete in all respect. MR |
| 245 | Supply and fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.(Ed e Plus LED Streetli ht) MR |
| 246 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. DSR 2.10.1 |
| 247 | Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 2 X 6 sq. mm MR |
| 248 | Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 4 X 10 sq. mm MR |
| 249 | Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 50 sq. mm DSR MR |
| 250 | Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 120 sq. mm MR |
| 251 | Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 150 sq. mm MR |
| 252 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering. Upto 35 sq. mm DSR 7.3.1 |
| 253 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering. Above 95 sq. mm and upto 185 sq. mm DSR 7.3.3 |
| 254 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm DSR 7.5.1 |
| 255 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm DSR 7.5.3 |
| 256 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm DSR 7.6.1 |
| 257 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm DSR 7.6.3 |
| 258 | Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) DSR 7.8.3 |
| 259 | Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) DSR 7.8.4 |
| 260 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 2 Core 6 sq.mm DSR 9.1.1 |
| 261 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 50 sq. mm DSR 9.1.22 |
| 262 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 120 sq. mm DSR 9.1.25 |
| 263 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 150 sq. mm DSR 9.1.26 |
| 264 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.(i) For Sewer Line250mm diameter |
| 265 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 250 mm. dia. RCC Pipes |
| 266 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 150(i) For Sewer Line |
| 267 | Extra for depth of man hole size 90x80 cm |
| 268 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 269 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250mm diameter |
| 270 | Provding and fixing gun metal non return valve of approved quality (screwed end)65 mm nominal borea) Horizontal18.19.5.1 |
| 271 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)65mm nominal bore.18.12.7 |
| 272 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)50mm nominal bore.DSR18.12.6 |
| 273 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)32mm nominal bore.DSR18.12.4 |
| 274 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work.65mm diameter pipe DSR18.41.7 |
| 275 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work.50 mm diameter pipe DSR18.41.6 |
| 276 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work.32 mm diameter pipe DSR18.41.4 |
| 277 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 65 mm nominal bore DSR18.17.5 |
| 278 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.50 mm nominal bore DSR18.17.4 |
| 279 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.32 mm nominal bore DSR18.17.2 |
| 280 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for stop cock, with C.I. surface box 100x100x75mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 150 DSR18.32.1 |
| 281 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm dia nominal bore DSR18.13.1 |
| 282 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm dia nominal bore DSR18.13.2 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy