| 1 | PART -I - COMPREHENSIVE MAINTENANCE OF B/R WORKS |
| 2 | Taking up or down steel water tubings and connections of 15mm bore pipe including cleaning or re-fixing or removal to store, complete all as specified and directed. |
| 3 | Taking up or down steel water tubings and connections of 20mm bore pipe including cleaning or re-fixing or removal to store, complete all as specified and directed. |
| 4 | Cutting existing steel tubing of size 15/20mm for alterations or additions (Each cut measured) complete all as specified and directed. |
| 5 | M & L for Cutting chases for concealed water tubing of any type of wall, pinning in. making good to facings where required and pointing in CM 1:3 etc., and making good by applying wall care putty etc, cutting not exc 10 cm girth complete all as specified and directed. |
| 6 | Supply and laying of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or layuing in floors complete all as specified. |
| 7 | Supply and laying of CPVC pipes 25 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or layuing in floors complete all as specified. |
| 8 | Cutting holes into or through brick walls superficial area exc 150 sqcm but nexc 400 sqcm built in cement mortar and making good in CM 1:3 or cement concrete 1:2:4 type B-l as required |
| 9 | S&F in repairs 15mm bore Pillar taps bore cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe, complete all as specified. Make : Hindware |
| 10 | S&F in repairs 15mm bore stop valve/Angle cock, chromium plated fancy type cast copper alloy, screwed down high pressure, with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed of,complete all as specified and directed. Make : Hindware |
| 11 | S&F in repairs 15mm bore Bib taps, cast copper alloy chromium plated with crutch or butter-fly handle screwed down, screwed for iron pipe or for brass ferrules, complete all as specified and directed. Make : Hindware |
| 12 | S&F in repair 15mm bore brass CP mixer for mixing hot & cold water, screwed down for iron pipe and fixed, complete all as specified and directed. Make : Hindware |
| 13 | S&F in repairs 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 142gms) complete all as specified and directed. Make: Prayag |
| 14 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc, from tanks capacity exc 500 and n.exc 1000ltr and from mouths of circulating pipes, etc. complete all as specified and directed |
| 15 | S&F in repairs 15mm bore Bib tap standard of PTMT any colour screwed, for iron pipe (minimum wt 90gm), all as specified and directed. |
| 16 | S&F in repairs 15mm bore angle/stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, minimum weight 90 gms, complete all as specified and directed. |
| 17 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm,complete all as specified and directed. |
| 18 | S&F in repairs 125mm Chromium plated shower roses with or without swivel joints, including fixing to steel pipe or union Make: Parryware |
| 19 | S&F in repairs 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, all as specified and directed. |
| 20 | S&F in repair Lid for rotational moulded polyethylene water storage tanks (any capcity) complete all as specified and directed |
| 21 | S&F in repairs Tubular towel rail, brass chromium plated 20mm dia D type, 60cm long between flanges, complete all as specified and directed. |
| 22 | S&F in repairs only brass chromium plated Health Faucet with 1mtr Flexible tube & Hook complete all as specified and directed Make : Prayag |
| 23 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick, 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed. |
| 24 | S&F in repairs Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. Make : Parryware |
| 25 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern) white(excluding flushing cistern and flush pipe) including connection to drain or out going pipe and flush pipe anti symphonize pipe etc complete all as specified and as directed. Make : Parryware |
| 26 | S & F in repairs of 10 litre capacity of Vitreous China valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 32mm flush pipe etc complete all as specified and as directed Make : Parryware. |
| 27 | S&F in repairs Vitreous China squatting pan of 'Orissa' pattern of size 580 x 440mm, white, with integral foot rests, complete including provision of lime concrete bedding all as directed. Make : Parryware |
| 28 | S&F in repairs Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern including all joints |
| 29 | S&F in repairs Vitreous China wash Basin (flat back or angle back type) , of size 550x400mm including brackets, waste coupling PTMT, and waste pipe PVC 32mm dia including cutting for and pinning in ends of brackets or erecting stand etc, complete all as specified Make : Hindware. |
| 30 | S&F in repairs 32mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms) |
| 31 | S&Fin repairs PVC waste pipe 32mm bore all as specified |
| 32 | S&F in repairs 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, all as specified and directed. |
| 33 | S&F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms) |
| 34 | Taking down PVC (SWR) pipes 110/75mm internal dia laid in trenches or fixed to walls incl all fittings complete all as specified. |
| 35 | S&F PVC (SWR) pipe 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 36 | S&F PVC (SWR) pipe 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 37 | S&F PVC (SWR) pipe 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and directed. |
| 38 | S&F PVC (SWR) pipe 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls, complete all as specified and directed. |
| 39 | S&F 110mm bore PVC (SWR) bends any radius, complete all as specified and directed. |
| 40 | S&F 75mm bore PVC (SWR) bends any radius, complete all as specified and directed. |
| 41 | Material and labour for preparation of old surfaces including washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil emulsion distemper on wall all as specified and as directed. |
| 42 | Material and labour for preparation of old surfaces of wall including washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of Acrylic Smooth exterior paint (@1.67 ltr/10 sqm over and including primining coat of exterior primer applied @ 2.20 Kg/10 sqm) of required shade all as specified and as directed. |
| 43 | Material and labour for prepartion of old painted surfaces of wood and wooden based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. |
| 44 | Material and labour for preparation of old painted surfaces of steel and iron of any description over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. |
| 45 | Material and labour for preparation of old surfaces including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots on ceiling and applying one coat of white wash all as directed. |
| 46 | S & F in repairs for curtain rails with modular brackets, stainless steel, chromium plated with fixing brackets, stops, rollers etc all as specified and as directed |
| 47 | S&F in repair solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge mitre cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mmx15mm MS square tube inside the 19mm MS square tube and suitably screwed complete all as specified and as directed. |
| 48 | S&F in repair factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick(styles) with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on front face and 2mm plain colour PVC sheet on backface, supplying and fixing in frame at site as per specification complete all as specified and as directed. |
| 49 | S&F in repair of 75mm size, butt hinge medium weight cold rolled mild steel & fixed complete all as specified & directed. |
| 50 | S&F in repair of 100 mm length aluminum, anodised, barrel tower bolts of extruded section and fixed. |
| 51 | S&F in repair of 100mm size aluminum handles, cast type anodised complete all as specified & directed. |
| 52 | Supply and fix in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width aperture 1.40mm and fixed with stainless steel wire staples all as specified and as directed |
| 53 | S&F in repairs anodised aluminimum window shutters/Ventilators (Powder coated), fixed type without sash bar, aluminimum section 0.55 kg/m including necessary joining cleats, glazing clips, handles, hinges, screws, rubber packing, anodised aluminimum snap beading screws etc., complete all as specified and directed |
| 54 | S & F in repairs anodised aluminium frame (Powder coated) for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 55 | S & F in repairs anodised aluminium door shutters (Powder coated), aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws, locks, etc. complete all as specified & directed. |
| 56 | S & F in repair of Aluminium die cast body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified & directed. |
| 57 | S&F for 5.5mm thick sheet glass, ordinary/figured quality and glazing with oil putty in square exc 0.50 Sqm in each pane complete all as specified and as directed |
| 58 | M&L for 12mm thick prelaminated particle board exterior garade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to aluminimum frame work shutter etc.,all as specified and as directed. |
| 59 | S & F in repair of Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 60 | Taking down chowkats or frames exc 1.5Sqm and not exc. 4Sqm each with shutters (without taking off shutters from the frames), complete all as specified and directed. |
| 61 | M & L for forming Jambs etc to openings (to forgoings items) incl cutting, toothing and properly bonding into old work also facing, jointing and pointing to match existing work in CM 1:6 complete all as specified and as directed |
| 62 | S & F small articles of steel such as hold fast, etc of Gde Fe 410-0 or Fe-290 Gde E-165 complete all as specified and directed. |
| 63 | M&L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in hold fast etc completed all as specified.. |
| 64 | M & L for preparing and treating ends of posts, back of chowkats with coal tar black paint, area tarred exc. 0.10 sqm but not exc. 0.50 sqm all as specified or as directed. |
| 65 | S&F Second class hardwood wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 66 | S & F of 35mm thick 2nd class hard wood (Kail) Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete, all as specified and directed. |
| 67 | S&F 30 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc, (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, cut and mitred beads for securing glass etc size of members of shutters as spd in SSR part I, section 8 complete all as specified and as directed. |
| 68 | M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 69 | S&F in repair 100 mm long aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed. |
| 70 | S&F in repair 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 71 | S&F in repair 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified |
| 72 | S&F in repair 150mm long Aluminium handles, cast type, anodised, all as specified and directed. |
| 73 | S&F in repair of floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor |
| 74 | S&F in repair Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed |
| 75 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete as specified and directed. |
| 76 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work, complete all as specified and directed. |
| 77 | M&L Brickwork with sub class B bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed |
| 78 | M&L Rendering 10mm thick on fair faces of brick work or concrete surface, in cement mortar 1:6 finished the surface even and smooth without using extra cement , complete, all as specified |
| 79 | M&L Rendering 5mm thick in CM 1:4 with WPC compound over a coat of 10mm thick in CM 1:6 on other than fair faces of brick work surfaces, even and smooth (without using extra cement), complete all as specified. |
| 80 | M&L Rendering 5mm thick on ceiling, in cement mortar 1:3 finished the surface even and smooth without using extra cement, complete, all as specified |
| 81 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper and one coat of 3mm thick wall care putty over a coat of alkali resistant primer complete all as specified. |
| 82 | M&L for preparation of newly plastered surface of walls and applying two coats of exterior emulsion paint and one coat of wall care putty over chalk whitening primer complete all as specified. |
| 83 | M&L for preparing newly plastered of ceiling surfaces and applying three coats of white wash complete all as specified. |
| 84 | Dismantling of ceiling board of any thickness. Including frame work complete all as specified. |
| 85 | S & F in repair of aluminium snap and false ceiling of panels of size 605 x 605 mm using aliminium anodised wall angle of size 25 x 25 x 1.5 mm thick fixed to walls with rawl plug and screws n exc 1.50m centre to centre and intermidiate panels using main \\"Tee\\" and cross \\"Tee\\"aluminium anodised section of size 35 x 25 x 1.50 mm and 25 x 25 x 1.50mm thick suspended with and including 2mm dia GI wire n exc 1.2 m centre to centre including 9.5 mm thick PVC laminated Gypsum ceiling tiles complete all as specified and as directed. |
| 86 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc in hard/ dense soil all as specified and directed. |
| 87 | M&L Reinforced concrete pipes, 100mm bore class NP2, laid and jointed complete with collars laid in trenches and set and jointed in CM 1:1, including demolition and breaking of existing salt glazed ware/ AC/ Reinforced concrete pipe complete all as specified and as directed. |
| 88 | M&L Reinforced concrete pipes, 150mm bore class NP2, laid and jointed complete with collars laid in trenches and set and jointed in CM 1:1 including demolition and breaking of existing salt glazed ware/ AC/ Reinforced concrete pipe complete all as specified and as directed. |
| 89 | M&L Reinforced concrete pipes, 200mm bore class NP2, laid and jointed complete with collars laid in trenches and set and jointed in CM 1:1 including demolition and breaking of existing salt glazed ware/ AC/ Reinforced concrete pipe complete all as specified and as directed. |
| 90 | Material and labour for concrete bed to SWG/Reinforced concrete pipe line of 100mm bore with PCC (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 91 | All as per Item No 90 described herein before but for 150mm bore pipe. |
| 92 | All as per Item No 90 described herein before but for 200mm bore pipe. |
| 93 | Demolition of reinforced cement concrete concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 94 | Material and labour for mild steel deformed TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed. |
| 95 | Material and labour for precast cement concrete in (1:2:4) type B1 (using 20mm graded stone aggregate) set in cement mortar 1:6 as in landings, cover slabs chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face including necessary form work complete all as directed. |
| 96 | Material and labour for cement concrete (1:3:6), type C1 (using 20mm graded stone aggregate) as in copings, including weathering, slightly rounded or chamfered angles and throating, as directed., including necessary form work all as directed. |
| 97 | Material and labour for rendering 15mm thick in cement mortar (1:4) with WPC on other than fair faces of brick work or concrete surface as in manholes, Septic tank etc., finished fair and even complete all as specified and as directed. Note : WPC shall be measured and paid separately |
| 98 | Supply only Liquid water proofing compound all as specified and as directed. |
| 99 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm using excavated soil complete all as specified and as directed. |
| 100 | Removal of excavated surplus soil to a distance exc 50 m and not exc 250m and depositing where directed at a level n. exc 1.50m above the starting point and all as directed. |
| 101 | PART -II - COMPREHENSIVE MAINTENANCE OF E/M WORKS |
| 102 | Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed. |
| 103 | Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through in existing non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including steel box of required module for modular switches/sockets and regulators all as specified complete for (a) one light point controlled by one switch. |
| 104 | (b) One switch socket outlet 3 pin 5 Amps on independent board. |
| 105 | (c) One switch socket outlet 3 pin 5 Amps on same board along with other switches |
| 106 | All as per item No 103.00 here-in-before but for point wiring with two 2.5 sqmm single core copper conductor multistranded FRLSH cable and one 2.5 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board and industrial socket complete all as specified and as directed. |
| 107 | M&L for replacement of Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 4 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 4 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed. |
| 108 | M&L for replacement of Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed. |
| 109 | M&L for replacement of Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 10 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 10 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 110 | M&L for replacement of Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 10 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 10 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed. Please Enable Macros to View BoQ information |