| 1 | Supplying weather proof sealent and applying over the bolts over the roof wherever required complete as per the direction of engineer-in-charge.(Rate shall inclussive of cost of sylicon sealent, labour charges for scaffolding etc.) |
| 2 | Supplying and pasting tarfelt APP sheets of reputed manufacture one layer over A.C sheet expansion joints, ridges etc after cleaning the surface and applying roofing compound etc complete. (The rate shall include cost of tarfelt ,roofing compound labour charges scaffolding etc complete. The work is to be carried out at roof of godown at a height up to 12Mtrs from ground level after observing all safety norms) |
| 3 | Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of:Asbestos Cement sheet(item no: 15.28.2 of DSR 2023) |
| 4 | Deduct cost of salvagable materials received from the work of dismantling work on as is where is condition including removing from the site - AC sheet |
| 5 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (item no: 12.50 of DSR 2023). |
| 6 | Providing and fixing green precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating120 grams per sqm as per IS: 277, in 240 mpa microns epoxy primer on both side of the sheet and polyester topsteel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete. Profiled ridge (950 to 1000 mm) Item similar to Item no 12.51.1 of DSR 2023). |
| 7 | Cleaning masonry drains of width 25 cms to 60 cms and depth up to 60 cms, including removal of silt and rubbish, cutting and removing grass and other vegetation from the sides of drains and disposal of rubbish within a distance of 150 mts.etc.complete. |
| 8 | Taking out RCC cover slabs (50 mm thick) of drain care fully without any damage and keeping the same in position after cleaning the drain etc complete |
| 9 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar(15.9.2) |
| 10 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar.(item no: 15.7.4 of DSR 2023). |
| 11 | Providing and laying factory made pre cast solid blocks of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above plinth up to floor two level with thickness 15cm in CM 1:6 ( 1 cement : 6 coarse sand) etc complete. |
| 12 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)(Item No.5.15,DSR 2023) |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more..( item no: 5.22.6 of DSR 2023) |
| 14 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (item 13.1.1 of DSR 2023) |
| 15 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead : With cement mortar 1:4 (1 cement : 4 coarse sand) .(Item No 14.1.2 of DSR 2023) |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).(item no: 4.1.3 of DSR 2023) |
| 17 | Reparing/Servicing rolling shutters such as removal of top covers tightening/ loosening the springs adjusting the dislocation of parts if any and applying greese to the springs side guides ( 0.40 kg greese/ shutter) after cleaning and refixing the cover in position etc as directed by engineer in charge. |
| 18 | Cleaning of well/sump including removing the cover and refixing, dewatering, removing silt , clay etc from the bottom of the well, cleaning the walls of the well, removal of vegetation along sides, disposal of all debris etc. complete as directed by the Engineer-in-charge (The work is carried out after following all the safety norms) (the rate shall include all labour, hire charges of the pump equipment, scaffolding etc). |
| 19 | Cleaning of main over head tank and other P.V.C.tanks installed over the roof of depot/ staff quarters and other buildings etc. including removal of silt/rubbish from tank, disinfecting with bleaching powder @ 0.5 gm per litre capacity of tank, disposal of silt/debris outside the FCI boundary etc.. all complete as per direction of Engineer-in-charge. (The work has to be carried out at roof top level after following all the safety norms)(Analysed rate) |
| 20 | Cleaning of septic tank with cleaning machine fitted with pump having 4000 litres suction capacity including removing the cover slab, cleaning and dechocking of sewer line, taking out sediments sludge etc and disposal at safe place and cleaning the premise of tank complete as directed by the Engineer-in -charge (Analysed based on item 14.77 of DSR 2023) |
| 21 | Providing and fixing radial exhaust turbo ventillators/extractor capacity of minimum 100cuft per minute air circulated fan of 22\\" throat dia weight of 5.5kg having throat dia wind ventillator with FRP base plate, including cost of fixing turbo/wind ventillator on new 0.50mm thick pre-coated GI profile sheet roofing on godown roof lincluding the cost of transportation of all materials tools and plants, fixtures & fastenings. Labour, insurance, safety measures etc and as directed by the Engineer in charge including guarantee of turbo ventillators of minimum 03 years and performance warranty etc complete.( HQrs approved rate) |
| 22 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix).(item 15.2.2 of DSR 2023) |
| 23 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(item 2.27 of DSR 2023) |
| 24 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) Item No.4.1.8 of DSR 2023. |
| 25 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.(Item No.11.4,DSR 2023) |
| 26 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick(item no: 11.13 of DSR 2023) |
| 27 | Providing and laying Red oxide flooring including polishing etc.. all complete as per the direction of Engineer-In-Charge. (Observed data) |
| 28 | Painting standard stack plan inside the godown with approved quality Floor paint after marking the size and painting Two coat paint above primer measuring 100 mm wide around the periphery of stack etc. complete as per direction of Engineer in charge. |
| 29 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap(Item No.17.7.11,DSR 2023) |
| 30 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.(14.79) |
| 31 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap (17.7.2) |
| 32 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (10.16.1) |
| 33 | Wall painting with acrylic emulsion paint,having VOC(Volatic Oraganic Compound) content less than 50 grams / litr of approved brand and manufacture,including applying additional coats wherever required to achieve even shade and colour 13.82.2 two coats |
| 34 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. Complete(Item No.16.19,DSR 2023) |
| 35 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, and provided with horizontal lines and two diagonals interwoven with horizontal wires of barbed wire weighing 9.38 kg per 100 m(minimum), between the two posts fitted and fixed with G.I. Staples etc.. complete (Cost of posts, struts, concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire(Analysed as per item no.16.18.1 of DSR 2023) |
| 36 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium(minimum thickness of powder coating 50 micron)(Item no: 21.1.1.2 of DSR 2023) |
| 37 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately. Powder coated aluminium (minimum thickness of powder coating 50 micron (Item No.21.1.2.2 of DSR 2023) |
| 38 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (Item no:21.3.1 of DSR 2023) |
| 39 | Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) Item 14.6.1 of DSR 2023 |
| 40 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 41 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 42 | .Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames |
| 43 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (15.60) |
| 44 | Engaging hydraulic excavator and labour for collection of debris/waste, loading the waste in vehicle for disposal, clean and level the site including fuel and driver charge, etc complete as per direction of engineer in charge (excluding the rate for disposal).(Observed data) |
| 45 | Providing and installing Layout plan of depots printed on Vinyl flex board pasted on foam board of 5mm thickness of size 1.00m x 0.80m in appropriate locations in front of Depot Office.(Charges include material cost,transportation charges, labour cost for installation etc.) Please Enable Macros to View BoQ information |