| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift |
| 10 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work80 mm dia nominal bore |
| 11 | MS Fabricated Portable Office Container : - Providing and fixing MS Fabricated Portable Office container or cabin of size 20 ' Length x 10' Width x 8.50 ' Height with which includes all necessary fittings and 3 nos aluminium powder coated sliding window 3'x3' with safty grill canopy above the all the windows. Electric fittings : - Led Tube 3 Nos , Door light 1 no , Cabin fan 2 nos , MCB single pole 2 Nos , AC point - 1 Nos , Power point 3 nos ( Each 2 swithces and 2 Sockets ). Western Toilets Partition of Size 6'x4' : - which includes 4 mm thick ACP sheet internal wall paneling with pVC Door 1 Nos . Toilet Fitting :- WC & Helth , faucet gun 1 Nos , Water Tap SS 1 Nos , Flush tank 1 Nos , Hand wash basin 1 Nos , Wash basin tap SS 1 Nos , Overhead tank frame 1 Nos , and all necessary internal plumbing & electric fittings Electric Fittings : - Led Tube 1 Nos , Lower with Exhaust fan of 150 CFM 1 Nos . Including Loading , Transportation , Unloading & Stacking and Installation at Site Complete. Technical Specification FOR ( MS Fabricated Portable Office Container ) : - Bottom Frame : - 100 x 50 C- channel & 100 x 50 mm specially formed MS Square tubes. Top Frame :- Top frame made of 50 x 50 mm , 50x25 mm , 25x25 mm specially formed MS Squre tubes. Stiffeners Bottom : - 100 x 50 mm , 50 x 50 mm MS Square Pipes. Stiffeners Top : - 50 x 50 mm , 50 x 25 & 25 x 25 mm MS Square tubes . Side Wall Stiffeners : - Specially formed 50 x 50 , 50 x 25 mm 1.20 mm MS Square tubes.Panelling Outside :- 1.20 mm specially corrugated MS sheet of 18 G welded on MS Structure Frame. Slanted Roof Outside : - 1.20 mm thick slanted roof with specially formed rain gutters or water channel of MS sheet of 18 G welded on MS structure frame . Internal Wall Panelling : - Pre-laminated MDF Board of 8 mm & all vertical & Horizontal corners will be neatly & smoothly finished with aluminium sections for internal walls & ceiling. Insulation : - Thermal insulation of glass wool of density 48 Kg/ 50 mm inside roof & 25 mm glass wool for side walls. Bottom Flooring : - 18 mm bison board panels & 1.2 mm thick PVC Vinyl Carpet shall be fixed by means of self tapping screw shall be fixed on the floor. Aluminium Window : - Aluminium Powder coated sliding window in each container with 4 mm thick glass for all windows with safty grills & canopy above the windows. MS Door : - Door shall be external opening type made up of same material as wall with std. hardware lock & handle & canopy above the windows. MS Door : - Door shall be external opening type made up of same material as wall with std hardware lock & hanle & canopy above the door Wiring : - Wiring shall be done using PVC conduit & fire resisrance wires of ISI quality suitable for 240 V single phase AC supply , 1.50 sqmm , 2.5 sqmm thick copper cable for light & fan fittings , 6 amps switch & socket , 4 mm thick cable for main electric supply with MCB. . Electric Fittings : - LED tube light , Door light , Cabin Fan , AC point , power points , switches & socket s ( ISI Mark ) Outside Painting : - Phosphate the cabin externally and painting with coat of primer & Two coat of corrosion free paint. Hooks : - Specially formed 10' x 4 ' 16 mm thick MS hooks for easy lifting & shifting. |
| 12 | MS Fabricated Portable Office Container : - Providing and fixing MS Fabricated Portable Office container or cabin of size 20 ' Length x 10' Width x 8.50 ' Height with which includes all necessary fittings and 3 nos aluminium powder coated sliding window 3'x3' with safty grill canopy above the all the windows. Electric fittings : - Led Tube 3 Nos , Door light 1 no , Cabin fan 2 nos , MCB single pole 2 Nos , AC point - 1 Nos , Power point 3 nos ( Each 2 swithces and 2 Sockets ). Western Toilets Partition of Size 6'x4' : - which includes 4 mm thick ACP sheet internal wall paneling with pVC Door 1 Nos . Toilet Fitting :- WC & Helth , faucet gun 1 Nos , Water Tap SS 1 Nos , Flush tank 1 Nos , Hand wash basin 1 Nos , Wash basin tap SS 1 Nos , Overhead tank frame 1 Nos , and all necessary internal plumbing & electric fittings Electric Fittings : - Led Tube 1 Nos , Lower with Exhaust fan of 150 CFM 1 Nos . Including Loading , Transportation , Unloading & Stacking and Installation at Site Complete. Technical Specification FOR ( MS Fabricated Portable Office Container ) : - Bottom Frame : - 100 x 50 C- channel & 100 x 50 mm specially formed MS Square tubes. Top Frame :- Top frame made of 50 x 50 mm , 50x25 mm , 25x25 mm specially formed MS Squre tubes. Stiffeners Bottom : - 100 x 50 mm , 50 x 50 mm MS Square Pipes. Stiffeners Top : - 50 x 50 mm , 50 x 25 & 25 x 25 mm MS Square tubes . Side Wall Stiffeners : - Specially formed 50 x 50 , 50 x 25 mm 1.20 mm MS Square tubes.Panelling Outside :- 1.20 mm specially corrugated MS sheet of 18 G welded on MS Structure Frame. Slanted Roof Outside : - 1.20 mm thick slanted roof with specially formed rain gutters or water channel of MS sheet of 18 G welded on MS structure frame . Internal Wall Panelling : - Pre-laminated MDF Board of 8 mm & all vertical & Horizontal corners will be neatly & smoothly finished with aluminium sections for internal walls & ceiling. Insulation : - Thermal insulation of glass wool of density 48 Kg/ 50 mm inside roof & 25 mm glass wool for side walls. Bottom Flooring : - 18 mm bison board panels & 1.2 mm thick PVC Vinyl Carpet shall be fixed by means of self tapping screw shall be fixed on the floor. Aluminium Window : - Aluminium Powder coated sliding window in each container with 4 mm thick glass for all windows with safty grills & canopy above the windows. MS Door : - Door shall be external opening type made up of same material as wall with std. hardware lock & handle & canopy above the windows. MS Door : - Door shall be external opening type made up of same material as wall with std hardware lock & hanle & canopy above the door Wiring : - Wiring shall be done using PVC conduit & fire resisrance wires of ISI quality suitable for 240 V single phase AC supply , 1.50 sqmm , 2.5 sqmm thick copper cable for light & fan fittings , 6 amps switch & socket , 4 mm thick cable for main electric supply with MCB. . Electric Fittings : - LED tube light , Door light , Cabin Fan , AC point , power points , switches & socket s ( ISI Mark ) Outside Painting : - Phosphate the cabin externally and painting with coat of primer & Two coat of corrosion free paint. Hooks : - Specially formed 10' x 4 ' 16 mm thick MS hooks for easy lifting & shifting. |
| 13 | MS Fabricated Portable Office Container : - Providing and fixing MS Fabricated Portable Office container or cabin of size 40 ' Length x 10' Width x 8.50 ' Height with which includes all necessary fittings and 5 nos aluminium powder coated sliding window 3'x3' with safty grill canopy above the all the windows. Electric fittings : - Led Tube 5 Nos , Door light 1 no , Cabin fan 4 nos , MCB single pole 4 Nos , AC point - 2 Nos , Power point 6 nos ( Each 2 swithces and 2 Sockets ) . Western Toilets Partition of Size 6'x 4' : - Western Toilets Partition of Size 6'x4' : - which includes 4 mm thick ACP sheet internal wall paneling with pVC Door 1 Nos . Toilet Fitting :- WC & Helth , faucet gun1 Nos , Water Tap SS 1 Nos , Flush tank 1 Nos , Hand wash basin 1 Nos , Wash basintap SS 1 Nos , Overhead tank frame 1 Nos , and all necessary internal plumbing & electric fittings Electric Fittings : - Led Tube 1 Nos , Lower with Exhaust fan of 150 CFM1 Nos . Including Loading , Transportation , Unloading & Stacking and Installation at Site Complete. |
| 14 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |