| 1 | Snack Bar Electrical Work |
| 2 | 1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 4 | 1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm |
| 5 | 1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.40 mm |
| 6 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 7 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet |
| 8 | 1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 9 | 1.28.1 : Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module |
| 10 | 1.28.2 : Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module |
| 11 | 1.28.3 : Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.4 Module |
| 12 | 2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 13 | 2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 14 | 5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 15 | 1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 16 | 1.17.2 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x1.5 sq. mm |
| 17 | 1.50.1 : Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep |
| 18 | OD273425/2025-2026 : Supply of 305 mm sweep, 1400 rpm heavy duty exhaust fan with front guard, working on 230 V AC supply, etc. as per the direction of engineer in charge as required. |
| 19 | OD273628/2025-2026 : Supply and fixing of 10W LED mirror light fittings : Supply and fixing of 10 watts LED mirror light fittings with extruded aluminum housing with opal acrylic diffuser,complete with all accessories etc. as per the direction of engineer in charge asrequired. |
| 20 | 2.10.1 : Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"C\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 21 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 22 | OD286519/2025-2026 : SITC of KSEB Meter board : Fabrication, supply, Installation, testing & commissioning one number cubicle type energy meter board made out of 2mm thickMS sheet, Powder coated, including provision for fixing KSEB single phase energy meter , providing & fixing of 2nos 63A cut out fuses, phase indication lamps and one number 63A 2P SDF with HRC and provision for locking the incoming & amp;Metering section as required. |
| 23 | Lighting System Electrical Works |
| 24 | 7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning, protectivecovering and refilling the trench etc as required.Upto 35 sq. mm |
| 25 | 9.2.30 : Supplying and making outdoor end termination with cast resin compound includingaluminium lugs and other jointing materials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm |
| 26 | 2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 27 | 2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 28 | 5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 29 | OD276762/2025-2026 : Supply and installation of garden light poles of GI with polyster powder coated base plate 200x200x10 mm thk including 9watt LED light as directed by engineer incharge |
| 30 | OD276802/2025-2026 : Supply of A1 XLPE armoured power cable supply of following size heavy duty XLPE insulated and PVC sheathed armoured power cable, conductors of bestconductivity aluminium, 1.1KV grade, conforming to IS 7098 (PART-1) etc as required. |
| 31 | OD286845/2025-2026 : SITC of KSEB Meter board : Fabrication, supply, Installation, testing & amp ;commissioning one number cubicle type energy meter board made out of 2mm thickMS sheet, Powder coated, including provision for fixing KSEB single phase energymeter , providing & fixing of 2nos 63A cut out fuses, phase indication lamps andone number 63A 2P SDF with HRC and provision for locking the incoming &Metering section as required. |
| 32 | OD287678/2025-2026 : Lightning strike counter is used for recording times of lightning strike of various kinds of lightning eliminators and lightning rod It is kind of electromechanical counter with digit display facility, lightning strikes provides valuable information for the maintenance and safety of all structures and its occupants |
| 33 | Toilet Block Electrical Works |
| 34 | 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 35 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 36 | 1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm |
| 37 | 1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.40 mm |
| 38 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 39 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired. 15/16 amp switch |
| 40 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet |
| 41 | 1.26 : Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required. |
| 42 | 1.28.5 : Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.8 Module |
| 43 | 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). |
| 44 | 1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 6 pin 5/6 & 15/16 ampsmodular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 45 | 2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 46 | 2.17 : Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 47 | 2.3.1: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door |
| 48 | 2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door |
| 49 | 2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 50 | 5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 51 | OD287037/2025-2026 : Erection pump set 1HP installed with proper switch board and wiring as per it rules and KSEB standards |
| 52 | OD287038/2025-2026 : SITC of KSEB Meter board : Fabrication, supply, Installation, testing &commissioning one number cubicle type energy meter board made out of 2mm thickMS sheet, Powder coated, including provision for fixing KSEB single phase energymeter , providing & fixing of 2nos 63A cut out fuses, phase indication lamps andone number 63A 2P SDF with HRC and provision for locking the incoming &Metering section as required. |
| 53 | OD287040/2025-2026 : Supply and fixing of 10W LED mirror light fittings : Supply and fixing of 10 watts LED mirror light fittings with extruded aluminum housing with opal acrylic diffuser, complete with all accessories etc. as per the direction of engineer in charge asrequired. |
| 54 | OD287068/2025-2026 : Supply of 305 mm sweep, 1400 rpm heavy duty exhaust fan with front guard, working on 230 V AC supply, etc. as per the direction of engineer in charge asrequired |
| 55 | OD288032/2025-2026SMPS Based Power Supplies |
| 56 | OD288054/2025-2026 : 4 Channel Digital Video Surveillance System, record rate 100 FPS – record and viewing shall be 25 FPS per Camera, with built in Multiplexer, Video motion detection, smart search with TCP – IP connectivity, recording on real time , high quality (24 hours, 30 days), HDD suitable for 24 hours and 30 days recording, Windows 2007 Professional OS, MPEG 4 plus and other options, Resolution – 640 x480 pixels, suitale for conneting the CCTV’s |
| 57 | OD288121/2025-2026 : Hik vision DS-2DE4425IW-DE 4-inch 4 MP 25X Powered by Dark Fighter IRNetwork Speed Dome, Outdoor HD Network Camera Please Enable Macros to View BoQ information |