| 1 | Dismantling of asbestos cement ( plain ,corrugated, semi corrugated etc) sheets in roof coverings including ridges/ valley gutters, drip or similar work etc complete all as specified and directed |
| 2 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed |
| 3 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering or fixed to wall with self tapping screws complete all as specified and directed |
| 4 | S&F for Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering or fixed to wall with self tapping screws complete all as specified and directed. |
| 5 | S&F for 2 mm thick Fibre glass reinforced translucent corrugated / plain sheeting with twocorrugations side lap in corrugated sheet or 100 mm lap in plain sheet fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 6 | S& F in repiar for Plain,mild steel sheeting 0.63 mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed |
| 7 | S&F MS 1.25 mm thick MS plain black sheet in steel gates and similar work, cut to size, holes punched, including round headed screws and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded as required. complete all as specified and directed. |
| 8 | S&F in repair 4mm th Sheet glass, ordinary quality in square in not exc 0.5 sq.m in each pane complete all as specified and directed. |
| 9 | S&F for 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valleygutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed. |
| 10 | Excavating in post holes (or similar holes) in any type of soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed |
| 11 | Demolition of cement concrete unreinfoced in ground floor and paving n exc 15 cm thickness ( below or above ground level) and removing the unserviceable materials to a distance n exc 100m complete all as specified and as directed. |
| 12 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) Cement concrete in foundations filling, floor and mass concrete for column post etc complete all as specified as directed. |
| 13 | M&L for PCC 1:3:6 type C-0 using 12.5 mm granted crushed stone aggregate as hold fast/filling in pressed steel frame complete all as specified and directed |
| 14 | M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregates) as in roof kerbs, Chajja of window/ventilator or mud stops, rounded or chamfered on top of chajja & side edges of surfaces upto the height of 7.00 mtr etc complete all as specified and directed. { The rate is deemed to be inclusive of scaffolding/form work } |
| 15 | M&L 60mm thick rubber moulded glosy finished inter locking paver block with grey cement and pigment of any type and shape the minium compressive strenth not less then 350 Kg/ Sqcm as approved complete all as specified |
| 16 | M&L for Sand filling under floor including watering and consolidation. complete all as specified and directed. |
| 17 | M&L for Cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in flooring / plinth protection etc complete all as specified and directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete. |
| 19 | S&F for Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I S.1161-1979 grade St.-240 tubular trusses complete all as specified and directed. |
| 20 | S&F for Framed work of rolled mild steel conforming to Fe 410-W (GdeE- 250) quality A as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing complete all as specified and directed. |
| 21 | S&F in repair for 1.25mm thick Steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, but gear operated type and including bevel gear box and crank handle complete all as specified and directed. |
| 22 | S&F for Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 23 | S&F for Roof trusses(framed) of rolled mild sheel conforming Fe 410-W (GdeE- 250) quality A as a trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 24 | S& F for Rolled sections of rolled mild steel as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. and similar work conforming to Fe 410-W (Gde E- 250) qualityA complete all as spesified and directed . |
| 25 | M&L for Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete all as specified and directed. |
| 26 | Taking down (without taking of shutters from the frames) and Refixing of Steel rolling shutter of area exceeding 1.5 Sqm but not exceeding 4 Sqm, for Repair of ball bearing, spring ,top cover, anchoring rod, hasp & staple, bevel gear box,crank handle, and including oil greasing & servicing of shutter with Channel for smooth fuctioning complete all as specified and directed. |
| 27 | Taking down (without taking of shutters from the frames) and Refixing of Steel rolling shutter of area exceeding 4.0 Sqm but not exceeding 8.0 Sqm, for Repair of ball bearing, spring ,top cover, anchoring rod, hasp & staple, bevel gear box,crank handle, and including oil greasing & servicing of shutter with Channel for smooth fuctioning complete all as specified and directed. |
| 28 | Taking down and Refixing of Steel Gate shutter of area exceeding 4.0 Sqm but not exceeding 8.0 Sqm, for Repair of Roller/ ball bearing, anchoring rod, hasp & staple, bevel gear box,crank handle,and other accesories and including oil greasing & servicing of shutter with Channel for smooth fuctioning directed by Engg-in Charge complete all as specified and directed. |
| 29 | Dismantling tanks water tank exc 250 but n exc 500 ltr. complete all as specified and directed. |
| 30 | Dismantling tanks water tank exc 500 but n exc 1000 ltr. complete all as specified and directed. |
| 31 | S&F for rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed top), triple layer construction, in white colour ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with fitting etc. of 20 mm dia directed complete all as specified and as directed. |
| 32 | S&F for rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed top), triple layer construction, in white colour ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with fitting etc. of 20 mm dia directed complete all as specified and as directed. |
| 33 | Cleaning and removing all scale and dirt, etc, from tanks of capacity exc 1000 and n. exc 2000 ltr and from mouths of circulating pipes, etc. complete all as specified and directed by Engg-in-Charge. |
| 34 | S&F in repair for ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and as directed. |
| 35 | S&F in repair for Stop valves/Gate valves 20 mm dia cast copper alloy,screwed down, high pressure with crutch or butterfly handel, screwed both ends for iron pipe or for unions and fixe, complete all as specified and directed. |
| 36 | Taking up or down steel/CPVC 20 mm tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 37 | Supplying and laying of CPVC 20 mm outer diameter pipes SDR 11 & included Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 38 | S&F 20 mm mm ounter dia CPVC Brass Elbow/Tee/Male/Female Adaptor Tank Adaptor Union Etc With all fitting and fixed complete to walls, ceilings or laid in floors complete all as specified and directed. |
| 39 | S&F in repair roller blind decorated horizontal type with necessary pulling threads, including powder coated aluminium canopy box and bottom rail along with all arrangement fixed to door, window/ ventilation as per sample approval by GE completed all as specified & directed. |
| 40 | Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 41 | M&L for 18- 20mm thick granite Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white ement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding complete all as specified and directed. |
| 42 | S&F in repair 3mm thick Aiuminium composite panel for partition /cladding using aluminium composite panel sheet of 3mm thick( Platinum series of Envitect) over steel frame work,MS Tube (ACP will be fixed over MS tube welded over MS steel framed works) and filling the gaps with silicon,sealant and other material of approved quality as per sample approval by GE.complete all as specified and directed. Note :- mild steel frame work including nuts and bolts will be measured and paid seperately. |
| 43 | S&F in repair for metallic stainless steel (304 Grade) letter for emblem in logo or Devanagari/ English script, hieght of each letter should be minimum 300 mm with appropriate width i.e.(200mm -300 mm) and 25 mm thick with 40 mm depth of letter in 2 mm thick plate,fixed on vertical suraface at the side of entrance gate, complete all as specified and directed. |
| 44 | Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed. |
| 45 | Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed. |
| 46 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, including necessary aluminium fittings like aluminium butt hinges(125 mm) 03 Nos, aluminium handle(200mm) 02 Nos, aluminium tower bolts (200 mm)01 No, aluminium door stopper 01 Nos, and key lock complete all as specified and directed. Note:- filling material in door pannel glass/ ACP sheet will be measured and paid seperately in respective items. |
| 47 | S&F in repair for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket locking arrangements as per sample approval by GE. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note : (i) the rate of taking down and removing old alumnium scrap of door,/window/ ventilation/ fixed partition to be included.. |
| 48 | S&F in repair for Anodised aluminium work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket locking arrangements as per sample approval by GE. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note : (i) the rate of taking down and removing old alumnium scrap of door,/window/ ventilation/ fixed partition to be included. |
| 49 | S&F in repair for 5 mm thick glass for alumnium partiton /Door/ window/ ventilator fixed with EPDM rubber/ neoprene gasket all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 50 | S&F in repair for Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and directed. |
| 51 | S&F in repair for Door closer of aluminium ( die cast ) body hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1200 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed |
| 52 | S&F in repair for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed |
| 53 | Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, includinguding cover fillets all as specified and directed. |
| 54 | Providing & fixing ceiling with mineral fiber 12 mm thick micro tegular edged false ceiling tiles at all height ,False ceiling tiles of size 595x595 mm of approved texture design patterns having moisture content less than 2%, humidity resistance of 99%, as per IS 8225:1987, light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on inter- locking metal T-Grid of PVC coated Anodised aluminium snap grid frame work for false ceiling comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of size 600x 600mm, suspended from ceiling at approprite height from floor using galvanized mild steel wire and L- shape level adjuster of size 85x25x2mm Anodised aluminium perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. |
| 55 | S& F for corrogated PVC Wall Lining / cladding consisting of 7 -8 mm thick any colour or pattern inclusive of solvent cement and fixing at site on PVC frame with nails as per specifications and drawing completed all as specified & directed. |
| 56 | Dismentling of floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed. |
| 57 | M&L 25 mm thick type B-0 1:2:4 (using 12.5 mm graded stone aggregate) as in sub base. complete all as specified and directed. |
| 58 | M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6) complete all as specified and directed. |
| 59 | Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and forecast concrete articles, complete all as specified and directed. |
| 60 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. |
| 61 | Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed |
| 62 | M&L for 10mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement complete all as specified and directed |
| 63 | M&L for 10mm thick rendering in CM 1:4 on fair faces of brick work, finished even and fair without using extra cement complete all as specified and directed |
| 64 | M&L for rendering 5mm thick in CM 1:3 finished even and smooth with out using extra cement in ceiling complete all as specified and directed |
| 65 | M&L for preparing new plaster surfaces of ceiling and applying two coats of white wash over coat of primer of Chalk whiting, on plastered surfaces, complete all as specified and directed. |
| 66 | M&L for preparing new plaster surfaces of wall and applying two coats of oil bond distemper over and including priming coat of interior primer applied @0.90 litre/10 sqm over minimum 2 mm thick wall care putty in two coat, Each coat should have 1 mm thick complete all as specified and directed. |
| 67 | M&L for preparing new plaster surfaces of Walls and applying two coats of white wash over coat of primer of Chalk whiting, on plastered surfaces, complete all as specified and directed. |
| 68 | M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over new plaster surfaces of walls complete all as specified and directed. |
| 69 | M&L for Preparation of old decorated surface on ceiling and applying two coat of white wash complete all as specified and directed. |
| 70 | M&L for Preparation of old decorated surface on ceiling and applying one coat of white wash complete all as specified and directed. |
| 71 | M&L for Preparation of old decorated surface on wall and applying two coat of white wash complete all as specified and directed. |
| 72 | M&L for Preparation of old decorated surface on wall and applying one coat of white wash complete all as specified and directed. |
| 73 | M&L for Preparation of old distemper surface and applying one coat oil bound emulsion on wall surfaces white or tinted complete all as specified and directed. |
| 74 | M&L for complete removing existing treatment on wall surface and applying two coats of oil bond distemper over and including priming coat of interior primer applied @0.90 litre/10 sqm over minimum 2 mm thick wall care putty in two coat, each coat should have 1 mm thick complete all as specified and directed. |
| 75 | M&L for Preparation of old decorated surface on wall and applying one coat of cement base paint over plastered surfaces, complete all as specified and directed. |
| 76 | M&L for Preparation of old decorated surface on wall and applying two coat of cement base paint, on plastered surfaces, complete all as specified and directed. |
| 77 | M&L for Preparation of old decorated surface on wall and applying one coat of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over old surfaces of walls complete all as specified and directed. |
| 78 | M&L for complete removal of existing treatment and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over old surfaces of walls ( Note wall surface made smooth and application of distemper through Mechanical mean) complete all as specified and directed. |
| 79 | M & L Preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed. |
| 80 | M & L for preparation of old wooden Surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 81 | Schedule of Credit (MINUS) Rs. 2,06,025.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |