| 1 | Excavation work by mechanical means (hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width ir 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including excavated soil as directed, within a lead of 50m. DSR N.2.9.1 |
| 2 | 1:5:10(1cement :5coarse sand(zone-iii) derived from natural sourse: 10 graded stone aggregate 40mm nominal size derived from natural sources). DSR N.4.1.10 |
| 3 | Brick work with common burnt clay F.P.S. (non modular)bricks of class designation 7.5 in foundation and plinth in.cement mortar 1:6. DSR N.6.1.2 |
| 4 | Excavating,supplying,stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. DSR N. 2.25(a) |
| 5 | Brick work with common burnt clay F.P.S. bricks of class designation 12.5 in superstructure above plinth level upto floor level in.cement mortar 1:6. DSR N.6.3.2 |
| 6 | RCC work Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sourses). DSR N. 5.1.2 |
| 7 | RCC work Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sourses). DSR N. 5.1.2 |
| 8 | Reinforced cement concrete work in beams,lintels suspended floors, roofs having balconies, shelves, chajjas, bands, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20 mm nominal size derived from natural sources). DSR N. 5.3 |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and excluding reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR N. 5.2.2 |
| 10 | Steel reinforcement for R.C.C. work including straightening,cutting, bending,placing in position and binding all complete upto plinth level.mild steel and tensile steel bars. DSR N. 5.22.1 |
| 11 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR N. 10.2 |
| 12 | 12 mm cement plaster of mix in 1:6 (1 cement: 6 fine sand) DSR N. 13.1.2 |
| 13 | 15 mm cement plaster on the rough side of single or half brick wall of mix in 1:6 (1 cement: 6 fine sand) DSR N. 13.2.2 |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level in 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) . DSR N. 4.1.3 |
| 15 | 15 mm cement plaster on rough side of single or half brick wall of mix ( 1:4 (1 cement: 4 coarse sand). DSR N. 13.5.1 |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete DSR N. 5.9.1 |
| 17 | Suspended floors, roofs, landings, balconies and access platform . DSR N. 5.9.3 SLAB ,BEAM |
| 18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers DSR N. 5.9.5 PLINTH BEAM |
| 19 | Making grooves 15 wide and15mm deep in plaster of the wall or in celling vertically or horizontally as required. 15mm wide, 15 mm deep groove. 13.73.1 |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gram/litre, of approved manufacturer and of required shade and collour all complete to achieve even and colour, (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50gram/litre.DSR N. 13.41.1 |
| 21 | Finishing walls with water proofing cement paint of required shade ,New work (Two or more coats applied @ 3.84 kg/10 sqm).DSR N. 13.44.1 |
| 22 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters,35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.DSR N. 9.21.1 |
| 23 | Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. DSR N. 13.50.3+13.50.4 |
| 24 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. DSR N. 11.3.1 |
| 25 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. DSR N. 10.17 |
| 26 | Providing and laying vertified floor tiles in different sizes 600 x 600 mm with water absorption less than 0.08% and conforming to IS15622 of approved brand in all colour and shades laid on 20mm thick cement mortar 1:4 with greay cement [email protected]/sqm including grouting the joints with white cement and matching pigmentsetc complete . DSR 11.41.2 |
| 27 | Wiring point for light point/fan point/exhauxst fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc.as require DSR N.1.10.1 |
| 28 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, modular plate, suitable Ms box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.: Group A DSR NO.1.8.1 GROUP A |
| 29 | Supplying and fixing suitable GI box with modular plate and cover on surface,including providing and fixing 6pin 5/6A & 15/16A MODULAR socket outlet and 15/16A MODULAR switch connections etc as required |
| 30 | Supplying and fixing suitable GI box with modular plate and cover on surface,including providing and fixing 6pin 5/6A & 15/16A MODULAR socket outlet and 15/16A MODULAR switch connections etc as required |
| 31 | Supplying and fixing following rating, double pole, 240 V, 63A isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR NO.2.12.2 |
| 32 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.: single pole DSR NO.2.10.1 |
| 33 | Supplying and fixing following rating, double pole( Single phase and neutral) 240 V,40A residual current circuit breaker(RCCB) having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR NO.2.14.2 |
| 34 | Wiring for circuit/ submain wiring along with earth with the following sizes FRLS/HFFR PVC insulated copper conductor ,single core cable in surface steel conduit 2 x 4 sq mm + 1 x 4sq mm earth wire dedicated for ac ,as required. |
| 35 | Supplying and fixing single pole and neutral MCB distribution board 240 V on surface ressesd neutral bus, bar earth bar, interconnections 12 WAY double door |
| 36 | supply ,Instalation ,Testing and commissioning of 1200mm sweep, BEE 5 star rated,celing fan with Brush, suitable for 230v 50hz single phase AC min 350 RPM 1200mm service value>6.0 CM/Min/Watt, air delievery 210CM/min,regulator unit for speed control and all remaining accessories including safety pin, nuts and bolts .Supply,earthing etc.completed as required |
| 37 | Supplying, installation,testing & Commissioning of LED Recessed /surface Down lighter LED tube light with batten suitable for upto 1x22 watt on surface. Complete in all respect |
| 38 | S/F of Road sign and Informatory Board or marble stone patiya including all necessary fittings T&P required proper completion of work as directed by Engineer - in- charge. Please Enable Macros to View BoQ information |