| 1 | Schedule 'A' B/R |
| 2 | Surface excavation in loose/ soft soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Removing excavated soil not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point in soft soil, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Excavation in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre depth for foundation, etc., and getting out in hard soil, complete all as specified and directed by Engineer-in-Charge. |
| 5 | All as per Item no. 3 above but for each additional 1.5 Metre or part thereof in depth beyond the first 1.5 Metre, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material & Labour for Plain Cement Concrete Type D-2, 1:4:8 (using 40mm graded granite stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Material & Labour for Pre-cast cement concrete block masonry type C-1, 1:3:6 (20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard soil, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Removing Excavated soils not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point in hard soil, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Use and Waste of form work to sides of footing for fair finished surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Use and Waste of form work to sides of columns for fair finished surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Use and Waste of form work to sides of Beam for fair finished surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Use and Waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed by Engineer-in-Charge. |
| 14 | Use and waste of Form work to chajjas, troughs and chullahoods and similar items including edges for fair finished surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in Chajjas, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in Beams, cantilevers, bressummers, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in roof Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & Fixing Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material & Labour for rendering 15mm thick on fair faces of Brick work/PCC block masonry or Concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material & Labour for rendering 10mm thick on fair faces of Brick work/PCC block masonry or Concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material & Labour for rendering 5mm thick on ceiling concrete surfaces in cement mortar 1:4 and even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material & Labour for hard-core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material & Labour for 75mm thick PCC(1:3:6) type C-2, (20mm graded stone aggregate as in plinth protection laid in alternative panels, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material & Labour for granite 18 to 20mm thick (of any type) tiles, machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture or pigment to match the shade of granite stone including grinding and polishing, moulding edges as directed and making hole for gas pipe if required complete including 15mm thick rendering in Cement Mortar 1:4 as backing, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material & Labour for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5mm graded aggregate) as in levelling course in flooring, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material & Labour for Non-skid Ceramic tiles 10mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm screed bed or bedding layer in 1:4 Cement Mortar, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Material & Labour for Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in Cement Mortar 1:4 on vertical surface, complete all as specified and directed by Engineer-in-Charge. |
| 31 | Material & Labour for Vitrified Ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by Engineer-in-Charge. |
| 32 | Material & Labour for preparation of ceiling surfaces and applying two coat of oil bound distemper over a coat of primer, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Material & Labour for preparing plastered or un-plastered new wall surfaces applying two coats of Oil Bound distemper over coat of cement primer, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Material & Labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm per ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturer’s instructions, complete all as specified and directed by Engr-in-charge |
| 35 | Supply & Fixing factory made uPVC white colour fixed window/ventilator made of extruded profile with wall thickness of 2.3 mm (+-2mm). Window profile with hollow section with multi chamber .Frame (60mm x 58mm). T profile (one vertical length in between two shutters) (60mm x74mm). Glazed bead (35mm x 20mm) will be mitered cut and fusion welded at all corners. Including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick. galvanized steel frame (28mm x 21.5mm), T profile (27mm x 17mm) to be inserted in repair profile. Frame will be fixed to the wall with 8mm x 100mm long fasteners. 5mm thick glazing with selected quality glass (Note: The unit rate excludes cost of glass and includes all other connected accessories.) area n.exc. 1.00 sqm each fixed |
| 36 | Supply & Fixing for factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+-0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick galvanized steel frame (30mm x 18mm) 2 Nos, sliding sash (30mm x 18mm) 2nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100m long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate excludes cost of glass and includes all other connected accessories) area n.exc. 2.00 sqm each fixed from ground floor to any height of floors complete all as specified and as directed by Engineer-in-charge. |
| 37 | Material & Labour for in repair powder coated aluminium Door frame made of 91x 43x1.50mm sections and shutters made of 39.4x17.7x1.50 mm thick sections with 4mm thick tinted glass / ACP panel including hinges, sliding door bolts, locking arrangement, tower bolts, handle and door closer complete all as required, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply & Fixing 10-12mm thick toughened frosted glass including rounding to edges for partition or door along with all accessories including top pivot, bottom pivot, top patch, floor springs, H type handle, and patch lock etc., complete all as specified and directed by Engineer-in-Charge. |
| 39 | Material & Labour for powder coated aluminium Deco grill/chequered mesh of size 75mm x 75mm including 'U' channel etc; fixed, complete all as specified and directed by Engineer-in-Charge. |
| 40 | Material & Labour for 10mm thick rendering in cement mortar 1:4 mixed with water proofing compound including brushing with neat cement slurry @ 3kg per Sqm as in roofs (water proofing compound shall be measured separately), complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply only integral water proofing compound, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply and laying HYPERPLAS-STANDARD 3kg/sqm polymeric water proofing membrane incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sqm, followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/Sqm each at the top and bottom and applying of one coat of aluminium paint on the membrane complete including sealing all joints by themo fusion with minimum 10cm overlap all as per manufacturer’s instructions, complete all as specified and directed by Engineer-in-Charge. |
| 43 | Material & Labour for 25mm thick PCC 1:2:4, B0 (using 12.5mm graded granite stone aggregate) in roof covering, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and fixing 1000 litres capacity triple layer, rotational moulded, polythene water storage tank with cover (Cylindrical vertical with closed top), colour white, hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc., and including 25mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe along with 25mm gate valve, complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply & Fixing tubular towel rail, 20mm dia., D type, 60 cm long between flanges of brass chromium plated, complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply & Fixing soap dish of chromium plated fixed to plugs with chromium plated screws, complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply & Fixing corner glass shelf assembly of 12 inch size fixed to plugs with chromium plated screws, complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply & Fixing of health faucet 1mtr length with all accessories, complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply & Fixing of PVC (SWR) pipes single socketed in any length with rubber ring joints and accessories laid in floors/wall of 110mm bore, complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply & Fixing of PVC (SWR) bends 110mm, complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material & Labour for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 52 | Material & Labour Bevelled edge mirror, 600mm x 450mm of selected quality glass, mounted on 6mm thick or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply & Fixing of Ceramic white colour EWC with seat cover and dual flush tank single body wall mounted type, complete all as specified and directed by Engineer-in-Charge. |
| 54 | Supply & Fixing of Vitreous China ware wash hand basin white, flat back, size 550x400 mm size with cutting for and pinning ends of brackets or erecting stand including CP waste coupling, 32mm dia PVC waste pipe, complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply & Fixing of 15mm dia fancy type CP tap of brass type cast copper alloy with crutch or butterfly handle, complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply & Fixing of PVC connection of 15mm dia length 600mm with PTMT nuts, complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply & Fixing of Angle cock 15mm dia, caster copper alloy, screwed down, high pressure fancy type chromium plated, complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply & Fixing of CP Grating 100mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply and fixing of 32mm outer dia CPVC pipes SDR 11 & plain CPVC SER 11 fittings including bends, elbows, unions etc., fixed on wall concealed or exposed /ceiling or laying in floors, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fixing of 25mm outer dia CPVC pipes SDR 11 & plain CPVC SER 11 fittings including bends, elbows, unions etc., fixed on wall concealed or exposed /ceiling or laying in floors, complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply & Fixing of PVC waste pipe of 32mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply & Fixing of 15mm bore pillar taps cast copper alloy fancy type chromium plated screwed down high pressure with or without lettered HOT or COLD with long screwed shank and fly nuts screwed for iron pipes, complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply & Fixing of Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in Cement Mortar 1:2 securing urinal to plug including 60mm long brass screws, pointing around urinal back in Cement Mortar, fixing automatic flushing cistern with bracket, flush pipe, grating and union for discharge pipe, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Material & Labour for preparation of 3mm thick wall care putty on wall, complete all as specified and directed by Engineer-in-Charge. |
| 65 | Material & Labour for Anti-termite treatment of soil by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Material & Labour for Anti-termite treatment of soil by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified and directed by Engineer-in-Charge. |
| 67 | Material & Labour for Anti-termite treatment of soil by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply & Fixing Harrison rails stainless steel (Curtain rod/drapery rod), 20mm dia, powder coated with and including fancy type bracket 2 Nos of each opening and side stopper fancy type powder coated of required shape and size 2 Nos of each opening, complete all as specified and directed by Engineer-in-Charge. |
| 69 | Demolition of Concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engineer-in-Charge. |
| 70 | Material & Labour for 80mm thick M-40 Grade Machine pressed precast concrete paver block of any colour any shape and size confirming to IS 15658-2006 with grey cement and pigment, complete all as specified and directed by Engineer-in-Charge. |
| 71 | Material & Labour for 50mm thick Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed by Engineer-in-Charge. |
| 72 | Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, bed blocks, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work, complete all as specified and directed by Engineer-in-Charge. |
| 73 | Material & Labour for PCC 1:3:6 type C-2 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 74 | Material & Labour for PCC 1:3:6 type C-2 as in bed to drain pipes including packing under and hunching against the sides of pipes after they are laid and tested for 150mm bore pipe, complete all as specified and directed by Engineer-in-Charge. |
| 75 | Material & Labour for PCC 1:2:4 type B-1, 20mm graded stone aggregate as in coping, surface channels, benching, etc., of manholes finished fair and even, complete all as specified and directed by Engineer-in-Charge. |
| 76 | Material & Labour for precast cement concrete 1:2:4 type B-1 as in manhole cover and set in Cement Mortar 1:4 including formwork, complete all as specified and directed by Engineer-in-Charge. |
| 77 | Material & Labour for reinforced concrete pipes 150mm bore class NP-2, laid and jointed complete with collars, laid in trenches and jointed, complete all as specified and directed by Engineer-in-Charge. |
| 78 | Cutting into existing manholes in running sewage line for connecting new drains of 100/150 / 200mm internal dia of pipe, making good to walling and rendering, cutting out branch channel, and as required, complete all as specified and directed by Engineer-in-Charge. |
| 79 | Extra for forming fair finished channel or drain 30cm girth (inner girth) in cement concrete using extra cement including forms, moulds, stopped end, etc., complete all as specified and directed by Engineer-in-Charge. |
| 80 | Material & Labour for MS work such as Bands, straps, supports or stays, rungs, handles to manholes, rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed by Engineer-in-Charge. |
| 81 | Schedule 'A' E/M & Water Supply |
| 82 | Supply and Laying 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc., complete all as specified and directed by Engineer-in-Charge. |
| 83 | 25mm bore |
| 84 | Supply and laying 3 layer (inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches /walls /ceilings or laying in floors including all fittings complete of sizes:- |
| 85 | 50mm bore |
| 86 | Supply and fixing PPR Gate Valves (Brass Insert) of 25mm bore, complete all as specified and directed by Engineer-in-Charge. |
| 87 | 25mm bore |
| 88 | 50mm bore |
| 89 | Drilling and taping di pipe for branch connections of 50mm bore, complete all as specified and directed by Engineer-in-Charge. |
| 90 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core, complete all as specified and directed by Engineer-in-Charge. |
| 91 | Supply and laying double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size 63mm outer dia with all fittings. Laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc., for cable protection, complete all as specified and directed by Engineer-in-Charge. (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini |
| 92 | Material & Labour for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 25mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 1.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc. |
| 93 | One light point or one fan point controlled by one switch with cables 1.5 sqmm size |
| 94 | One 3 pin socket outlet 5 Amps on the same board with other switches, with cables 1.5 sqmm size |
| 95 | One 5 Amp socket outlet, independent, with cables 1.5 sqmm size |
| 96 | Supply & Fixing modular type 6 Amp one-way SP switch, complete all as specified and directed by Engineer-in-Charge. Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker) |
| 97 | Supply & Fixing modular type 2/3 pin combined 6 Amp socket, complete all as specified and directed by Engineer-in-Charge. Make :- Legrand (Arteor) / Schneider (Zencelo) / Hager (Berker) |
| 98 | Material & Labour for ceiling rose, 3-Ph/ PVC /polycarbonate, isolated body, complete all as specified and directed by Engineer-in-Charge.Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker) |
| 99 | Material & Labour for Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 25mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 2.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc., complete all as specified and directed by Engineer-in-Charge. |
| 100 | One 15 Amp socket outlet, independent, with cables 2.5 sqmm size |
| 101 | Supply & Fixing modular type 16 Amp one-way SP switch, complete all as specified and directed by Engineer-in-Charge.Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker) |
| 102 | Supply & Fixing Socket 6Amp/16Amp - 2/3 pin combined 2 module, complete all as specified and directed by Engineer-in-Charge.Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker) |
| 103 | Material & Labour Sub main wiring with two runs of 2.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I including conduit accessories like bends, tees, junction boxes etc including 2.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire fixed complete all as specified and directed.Make of cable: Havells/ Finolex/ RR Kable/ KEI |
| 104 | Supply and fixing in replacement of Modular Metal Flush box of following size complete all as specified and as directed.Make: Legrand/Schneider/Hager |
| 105 | 6 Module |
| 106 | 12 Module |
| 107 | Supply and fixing of Modular cover plate with frame of following size complete all as specified and as directed.Make: Legrand/Schneider/Hager |
| 108 | 6 Module |
| 109 | 12 Module |
| 110 | Supply & Fixing MCB (DB) SPN 8 way double door 415 V made of sheet metal enclosure for MCB's as incoming and SPN/SP MCB as outgoing, complete all as specified and directed by Engineer-in-Charge. |
| 111 | Supply & Fixing MCB (DB) SPN 4 way double door 415 V made of sheet metal enclosure for MCB's as incoming and SPN/SP MCB as outgoing, complete all as specified and directed by Engineer-in-Charge. |
| 112 | Material & Labour for MCB SPN pole 240 volt C curve 10 KA,ISI marked as per IS/IEC 60898-1 2002 of 32 Amps capacity IP 20, complete all as specified and directed by Engineer-in-Charge. |
| 113 | Material & Labour for MCB SP 240 volt C curve 10 KA, ISI marked as per IS/IEC 60898-1 2002 of 5-32 Amps capacity IP 20, complete all as specified and directed by Engineer-in-Charge. |
| 114 | Supply & Fixing of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984, complete all as specified and directed by Engineer-in-Charge. |
| 115 | Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with Earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the Earthing test point all as specified and indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge. |
| 116 | Supply & Fixing 25 W surface / wall mounted LED security light, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to LED Fitting with luminaire mounting arm, complete all as specified and directed by Engineer-in-Charge.Make : Wipro ( LR02-291-XXX-57-XX)/ Philips(BRP022 LED 20 CW MR S1 PSU GR)// Osram (STRADA PLUS CW L130x50) |
| 117 | Supply & Fixing 20 W surface / wall mounted LED batten, aluminium housing, operating Voltage 140-270, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to LED batten fitting, complete all as specified and directed by Engineer-in-Charge. Make: Wipro (LL20-281-XXX-65AL1/ Philips (BN108C LED 20S PSU NW WH)/ Osram (LUXSMART LED BAT 22W 830) |
| 118 | Supply & Fixing of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. |
| 119 | Supply & Fixing fans ceiling complete with accessories 220-240V, 50Hz, 1200mm sweep, Nominal Air delivery 215CMM, BEE 5 star rated, complete all as specified and directed by Engineer-in-Charge. |
| 120 | Supply and Fixing exhaust Fan 300mm sweep, 230 V, 50 Hz, single phase, 1400 RPM, including frame, dust proof and water resistant, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |