| 1 | Demolishing plain cement concrete manually/ by mechanical means unto 10 mtr height including disposal of material within 50 metres lead complete all as specified and directed. |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 3 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below complete all as specified and directed. |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead For thickness of tiles upto 25 mm complete all as specified and directed. |
| 6 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 7 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead, 15 mm to 40 mm nominal bore complete all as specified and directed. |
| 8 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead complete all as specified and directed. |
| 9 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 10 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level complete all as specified and directed. |
| 11 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba complete all as specified and directed. |
| 12 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and directed. |
| 13 | Dismantling C.I. or asbestos rain water pipe 100 mm dia with fittings and clamps including stacking the material within 50 metres lead complete all as specified and directed. |
| 14 | M&L for plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top surface smooth complete all as specified and directed. |
| 15 | M&L for stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2(1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : Red sand stone complete all as specified and directed. |
| 16 | M&L for Pre-cast cement concrete block masonry type C1 (1:3:6) 20 mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in mortar CM 1:6 complete all as specified and directed. |
| 17 | M&L for Pre-cast cement concrete block masonry type C1 (1:3:6) 20 mm graded stone aggregate with solid blocks, 10 cm in width and setting in mortar CM 1:4 complete all as specified and directed. |
| 18 | M&L for reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, (excluding the cost of centering, shuttering, finishing and reinforcement) with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 19 | M&L for use and waste of centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges complete all as specified and directed. |
| 20 | M&L for steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more complete all as specified and directed. |
| 21 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed, Profile B Fixing with adjustable lugs with split end tail to each jamb complete all as specified and directed. |
| 22 | M&L for Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works complete all as specified and directed. |
| 23 | M&L Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately) complete all as specified and directed. |
| 24 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors complete Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides complete all as specified and directed. |
| 25 | Providing & fixing glass panes in doors, uPVC / Aluminium windows, including with EPDM rubber / neoprene gasket etc all complete with : 5.50 mm thick glass panes (weight not less than 10 kg/ sqm) complete all as specified and directed. |
| 26 | Providing and fixing factory made uPVC colour as approved by Engineer-in-charge casement (Openable) window area exceeding 1.00 sqm but not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm).Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of 'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass complete all as specified and directed.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 27 | S&F factory made uPVC colour as approved by Engineer-in-charge Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed. (Glass or wire mesh shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 28 | S&F factory made uPVC colour as approved by Engineer-in-charge fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed. (Glass shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 29 | Providing and fixing glazing with frosted glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) in aluminium door, window, uPVC ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete all as specified and directed. (Cost of aluminium snap beading shall be paid in basic item): |
| 30 | Providing and fixing in repairs wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood complete all as specified and directed. |
| 31 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges (100mm size, medium grade, 3 Nos) with necessary screws complete all as specified and directed. |
| 32 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, complete all as specified and directed. |
| 33 | Providing and fixing in repairs 18 mm thick Single piece gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite stone slab of colour telephonic black, Cherry/Ruby red (Area of slab upto 0.50 sqm) for kitchen platforms, Stairs, vanity counters, window sills ,facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. complete all as specified and directed. |
| 34 | Providing and fixing in repairs 18 mm thick Single piece gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite stone slab of colour telephonic black, Cherry/Ruby red (Area of slab over 0.50 sqm) for kitchen platforms, Stairs, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. complete all as specified and directed. |
| 35 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, complete all as specified and directed.. (Glazing and panelling to be paid for separately) |
| 36 | S&F Powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weight not less than 0.55 Kg/Rm including jointing cleats aluminium snap beading/screws, powder coated aluminium fittings such as peg stays 150mm long (1 Nos),hinges type B-21 100 mm long (2Nos) suitable handle (1 Nos) per leaf complete all as specified and directed. |
| 37 | Providing and fixing Powder Coated aluminium grill of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved powder coated aluminium standard section around the opening, complete as per requirement as directed.Note : Only weight of grill to be measured for payment |
| 38 | Providing and laying Non Skid Ceramic floor tiles of size 300x300 mm, 7 to 8 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete all as specified and directed. |
| 39 | Providing and laying Non Skid Ceramic floor tiles of size 400x400 mm, 7 to 8 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete all as specified and directed. |
| 40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 41 | Providing and laying in floors Double charge vitrified tile polished finish of Size of Tile 600 x 600 mm , 10 mm thick with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 42 | Providing and laying Glazed Vitrified tiles Matt/Antiskid finish Size of Tile 600 x 600 mm, 10 mm thick with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 43 | Providing and laying vitrified tiles Size of Tile 600x600 mm, 10 mm thick with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed. |
| 44 | Providing and laying Double charge vitrified tile polished finish of Size of Tile 600 x 1200 mm, 10 mm thick with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 45 | Providing and laying Glazed Vitrified tiles Matt/Antiskid finish of size of Size of Tile 600 x 1200 mm, 10 mm thick with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 46 | Providing and laying vitrified tiles Size of Tile 1000x1000 mm, 10 mm thick with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed. |
| 47 | M&L for in repairs 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) complete all as specified and directed. |
| 48 | M&L for in repairs 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) complete all as specified and directed. |
| 49 | M&L for in repairs 12 mm cement plaster on ceilings in CM 1:3 (1 cement: 3 fine sand) complete all as specified and directed. |
| 50 | M&L for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7'/9' to make the surface free from dust loose paint etc, by skilled labour complete all as specified and directed. |
| 51 | M&L for single component polymer modified repair mortar with compressive strength minimum 38 MPA at 28 days (ASTM C 109:99) and tensile strength minimum 2.5 MPA (ASTM C 307) up to 15mm in a single coat @ 34 Kg per Sqm for 15mm thickness as per manufacturer instructions complete all as specified and directed. |
| 52 | M&L for water proof cement based putty @ 1kg (undiluted) per sqm of average thickness 1mm over the plastered / old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500 sanding pad of 240 Grit or above to make the surface free from dust etc by skilled labour as per following steps:-Step 1 :- Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2 :- Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a minimum pressure 3300 PSIStep 3 :- Allow 6-8 hrs time to dry the putty surface. |
| 53 | M&L for one coat of acrylic water based interior grade primer @0.8 ltr (undiluted)/10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed. |
| 54 | M&L for applying two coats of oil bound distemper using airless spray technology with max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note:- Sanding of surface to be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by paint manufacturer. |
| 55 | M&L for two coats of smooth interior acrylic emulsion with rich matt finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 Ltrs (undiluted)/ 10 Sqm diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs dry the surface in both the coats of paints as per manufacturer instructions, complete all as specified and directed. |
| 56 | M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surfaces, complete all as specified and directed. Note:- Sanding of surface to be done by mechanical sander with 1500- 2700 rpm with internal dust extraction system for clean environment certified by paint manufacturer. |
| 57 | M&L for one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed. |
| 58 | M&L for two coat of water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & colour stay Technology, Excellent Dirt pick up resistance with low VOC less than 50 grm/ Ltr as per the LEEDS specifications anti algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over primed surface with fully automatic airless spray machine of pain application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs dry the surface in both the coats of paints as per manufacturer instructions, complete all as specified and directed.Note : (a) The work pertaining to periodical services shall be executed from authorized applicator through manufacturer of which the materials i.e. paint distemper, cement base paint putty etc is proposed to be used by the contractor and approved by Engr-in-charge Please Enable Macros to View BoQ information |
| 59 | M&L for two coat of water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & colour stay Technology, Excellent Dirt pick up resistance with low VOC less than 50 grm/ Ltr as per the LEEDS specifications anti algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over primed surface with fully automatic airless spray machine of pain application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs dry the surface in both the coats of paints as per manufacturer instructions, complete all as specified and directed.Note : (a) The work pertaining to periodical services shall be executed from authorized applicator through manufacturer of which the materials i.e. paint distemper, cement base paint putty etc is proposed to be used by the contractor and approved by Engr-in-charge Please Enable Macros to View BoQ information |